Near‐Infrared‐II Quantum Dots for In Vivo Imaging and Cancer Therapy
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
In vivo fluorescence imaging can perform real‐time, noninvasive, and high spatiotemporal resolution imaging to accurately obtain the dynamic biological information in vivo, which plays significant roles in the early diagnosis and treatment of cancer. However, traditional in vivo fluorescence imaging usually operates in the visible and near‐infrared (NIR)‐I windows, which are severely interfered by the strong tissue absorption, tissue scattering, and autofluorescence. The emergence of NIR‐II imaging at 1000–1700 nm significantly breaks through the imaging limitations in deep tissues, due to less tissue scattering and absorption. Benefiting from the outstanding optical properties of NIR‐II quantum dots (QDs), such as high brightness and good photostability, in vivo fluorescence imaging exhibits excellent temporal‐spatial resolution and large penetration depth, and QDs have become a kind of promising fluorescent biomarkers in the field of in vivo fluorescence imaging. Herein, the authors review NIR‐II QDs from preparation to modification, and summarize recent applications of NIR‐II QDs, including in vivo imaging and imaging‐guided therapies. Finally, they discuss the special concerns when NIR‐II QDs are shifted from in vivo imaging applications to further in‐depth applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
In Vivo Imaging of Quantum Dots Encapsulated in Phospholipid Micelles
Dubertret, B., Skourides, P., Norris, D. J., Noireaux, V., Brivanlou, A. H., & Libchaber, A. (2002) · Science · doi:10.1126/science.1077194 · Cited by 3,019
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Hu, Z., Fang, C., Li, B., Zhang, Z., Cao, C., Cai, M., Su, S., Sun, X., Shi, X., Li, C., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0494-0 · Cited by 1,126
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Hong, G., Zou, Y., Antaris, A. L., Diao, S., Wu, D., Cheng, K., Zhang, X., Chen, C., Liu, B., He, Y., et al. (2014) · Nature Communications · doi:10.1038/ncomms5206 · Cited by 563
Bright quantum dots emitting at ∼1,600 nm in the NIR-IIb window for deep tissue fluorescence imaging
Zhang, M., Yue, J., Cui, R., Ma, Z., Wan, H., Wang, F., Zhu, S., Zhou, Y., Kuang, Y., Zhong, Y., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1806153115 · Cited by 432
Self-citationQi, J., Sun, C., Zebibula, A., Zhang, H., Kwok, R. T. K., Zhao, X., Xi, W., Lam, J. W. Y., Qian, J., & Tang, B. Z. (2018) · Advanced Materials · doi:10.1002/adma.201706856 · Cited by 418
A hybrid erbium(III)–bacteriochlorin near-infrared probe for multiplexed biomedical imaging
Wang, T., Wang, S., Liu, Z., He, Z., Yu, P., Zhao, M., Zhang, H., Lu, L., Wang, Z., Wang, Z., et al. (2021) · Nature Materials · doi:10.1038/s41563-021-01063-7 · Cited by 308
Self-citationMultiplexed NIR‐II Probes for Lymph Node‐Invaded Cancer Detection and Imaging‐Guided Surgery
Tian, R., Ma, H., Zhu, S., Lau, J., Ma, R., Liu, Y., Lin, L., Chandra, S., Wang, S., Zhu, X., et al. (2020) · Advanced Materials · doi:10.1002/adma.201907365 · Cited by 269
Light-sheet microscopy in the near-infrared II window
Wang, F., Wan, H., Ma, Z., Zhong, Y., Sun, Q., Tian, Y., Qu, L., Du, H., Zhang, M., Li, L., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0398-7 · Cited by 237
Cited by
Li, Y., Zhang, P., Tang, W., McHugh, K. J., Kershaw, S. V., Jiao, M., Huang, X., Kalytchuk, S., Perkinson, C. F., Yue, S., et al. (2022) · ACS Nano · doi:10.1021/acsnano.2c01153 · Cited by 98
Second Near‐Infrared Window Fluorescence Materials for In Vivo Dynamic Multiplexed Imaging
Fan, F., Zeng, K., Zhu, Y., Zhang, Y., Chen, Y., Lv, D., Jia, D., Chai, Y., Chen, X., & Li, Q. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202422693 · Cited by 33
Molecular Imaging of Ovarian Follicles and Tumors With Near‐Infrared II Bioconjugates
Wang, Y., Lu, W., Chen, Z., Xiao, Y., Wang, Y., Gao, W., Wang, Z., Song, R., Fang, Z., Hu, W., et al. (2025) · Advanced Materials · doi:10.1002/adma.202414129 · Cited by 17
Self-citation
Metadata
- Authors
- Chen, L., Zhao, L., Wang, Z., Liu, S., & Pang, D.
- Venue
- Small
- Publisher
- Wiley
- Published
- 2021-11-26
- Volume
- 18
- Issue
- 8
- Pages
- e2104567-e2104567
- ISSN
- 1613-6810 (ISSN-L)
- 1613-6829
- OpenAlex
- W3216195326
- Cited by
- 161
- References
- 13
- FWCI
- 6.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.