The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Open accessAbstract
White blood cells are isolated from whole blood in silicon-glass 4.5-microliter microchips containing a series of 3.5-micron feature-sized 'weir-type' filters, formed by an etched silicon dam spanning the flow chamber. Genomic DNA targets, e.g., dystrophin gene, can be directly amplified using the polymerase chain reaction (PCR) from the white cells isolated on the filters. This dual function microchip provides a means to simplify nucleic acid analyses by integrating in a single device two key steps in the analytical procedure, namely, cell isolation and PCR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical Guide to Laboratory Tests.
(1991) · Annals of Internal Medicine · doi:10.7326/0003-4819-114-9-821-7 · Cited by 2,139
Use of a cDNA microarray to analyse gene expression patterns in human cancer
(1996) · Nature Genetics · doi:10.1038/ng1296-457 · Cited by 1,951
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Clinical diagnosis and management by laboratory methods
Henry, J. B. (1979) · Medical Entomology and Zoology · Cited by 1,691
Accessing Genetic Information with High-Density DNA Arrays
Chee, M., Yang, R., Hubbell, E., Berno, A., Huang, X. C., Stern, D., Winkler, J., Lockhart, D. J., Morris, M. S., & Fodor, S. P. A. (1996) · Science · doi:10.1126/science.274.5287.610 · Cited by 1,489
Geigy, J. R. (1981) · Medical Entomology and Zoology · Cited by 1,221
Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Shoemaker, D. D., Lashkari, D. A., Morris, D., Mittmann, M., & Davis, R. W. (1996) · Nature Genetics · doi:10.1038/ng1296-450 · Cited by 569
Ultra-High-Speed DNA Sequencing Using Capillary Electrophoresis Chips
Woolley, A. T., & Mathies, R. A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a010 · Cited by 564
Kozal, M. J., Shah, N., Shen, N., Yang, R., Fucini, R., Merigan, T. C., Richman, D. D., Morris, D., Hubbell, E., Chee, M., et al. (1996) · Nature Medicine · doi:10.1038/nm0796-753 · Cited by 527
Cited by
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,800
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Microfluidic devices for cellomics: a review
Andersson, H., & van den Berg, A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(03)00266-1 · Cited by 661
PCR microfluidic devices for DNA amplification
Zhang, C., Xu, J., Ma, W., & Zheng, W. (2006) · Biotechnology Advances · doi:10.1016/j.biotechadv.2005.10.002 · Cited by 634
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
Temperature Measurement in Microfluidic Systems Using a Temperature-Dependent Fluorescent Dye
Ross, D., Gaitan, M., & Locascio, L. E. (2001) · Analytical Chemistry · doi:10.1021/ac010370l · Cited by 631
Toner, M., & Irimia, D. (2005) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.7.011205.135108 · Cited by 623
Lab-on-a-chip for drug development
Weigl, B. H., Bardell, R. L., & Cabrera, C. R. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00223-5 · Cited by 481
A novel 3D mammalian cell perfusion-culture system in microfluidic channels
Toh, Y.-C., Zhang, C., Zhang, J., Khong, Y. M., Chang, S., Samper, V. D., van Noort, D., Hutmacher, D. W., & Yu, H. (2007) · Lab on a Chip · doi:10.1039/b614872g · Cited by 414
Microfluidics for flow cytometric analysis of cells and particles
Huh, D., Gu, W., Kamotani, Y., Grotberg, J. B., & Takayama, S. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/3/r02 · Cited by 396
Planar chip device for PCR and hybridization with surface acoustic wave pump
Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A. (2005) · Lab Chip · doi:10.1039/b412712a · Cited by 349
Cheng, J., Sheldon, E. L., Wu, L., Uribe, A., Gerrue, L. O., Carrino, J., Heller, M. J., & O'Connell, J. P. (1998) · Nature Biotechnology · doi:10.1038/nbt0698-541 · Cited by 347
Self-citationCell Culture Models in Microfluidic Systems
Meyvantsson, I., & Beebe, D. J. (2008) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.113042 · Cited by 345
PDMS-based micro PCR chip with Parylene coating
Shin, Y. S., Cho, K., Lim, S. H., Chung, S., Park, S.-J., Chung, C., Han, D.-C., & Chang, J. K. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/13/5/332 · Cited by 330
Yang, J., Huang, Y., Wang, X.-B., Becker, F. F., & Gascoyne, P. R. C. (1999) · Analytical Chemistry · doi:10.1021/ac981250p · Cited by 310
Recent advances in capillary electrophoresis/electrospray/mass spectrometry
Banks, J. F. (1997) · ELECTROPHORESIS · doi:10.1002/elps.1150181216 · Cited by 308
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
Lagally, E. T., Emrich, C. A., & Mathies, R. A. (2001) · Lab on a Chip · doi:10.1039/b109031n · Cited by 284
Isolation of plasma from whole blood using planar microfilters for lab-on-a-chip applications
Crowley, T. A., & Pizziconi, V. (2005) · Lab on a Chip · doi:10.1039/b502930a · Cited by 280
Dalili, A., Samiei, E., & Hoorfar, M. (2019) · The Analyst · doi:10.1039/c8an01061g · Cited by 280
Silicon-based microfilters for whole blood cell separation
Ji, H. M., Samper, V., Chen, Y., Heng, C. K., Lim, T. M., & Yobas, L. (2008) · Biomedical Microdevices · doi:10.1007/s10544-007-9131-x · Cited by 272
Metadata
- Authors
- Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P.
- Venue
- Analytical Biochemistry
- Publisher
- Elsevier BV
- Published
- 1998-03
- Volume
- 257
- Issue
- 2
- Pages
- 95-100
- ISSN
- 0003-2697 (ISSN-L)
- OpenAlex
- W2043591822
- Cited by
- 276
- References
- 19
- FWCI
- 15.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.