The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Critical review of non-invasive respiratory monitoring in medical care
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Noninvasive microwave measurement of respiration
Lin, J. C. (1975) · Proceedings of the IEEE · doi:10.1109/proc.1975.9992 · Cited by 429
Changes in tidal volume, frequency, and ventilation induced by their measurement.
Gilbert, R., Auchincloss, J. H., Brodsky, J., & Boden, W. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.33.2.252 · Cited by 353
Effects of respiratory apparatus on breathing pattern
Askanazi, J., Silverberg, P. A., Foster, R. J., Hyman, A. I., Milic-Emili, J., & Kinney, J. M. (1980) · Journal of Applied Physiology · doi:10.1152/jappl.1980.48.4.577 · Cited by 291
Nakajima, K., Tamura, T., & Miike, H. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)00066-6 · Cited by 244
A Single-blind Study of Combined Pulse Oximetry and Capnography in Children
Coté, C. J., Rolf, N., Liu, L. M. P., Goudsouzian, N. G., Ryan, J. F., Zaslavsky, A., Gore, R., Todres, I. D., Vassallo, S., Polaner, D., et al. (1991) · Anesthesiology · doi:10.1097/00000542-199106000-00003 · Cited by 220
Respiratory Monitoring in the Intensive Care Unit
Tobin, M. J. (1988) · American Review of Respiratory Disease · doi:10.1164/ajrccm/138.6.1625 · Cited by 200
Separation of factors responsible for change in breathing pattern induced by instrumentation
Perez, W., & Tobin, M. J. (1985) · Journal of Applied Physiology · doi:10.1152/jappl.1985.59.5.1515 · Cited by 165
Monitoring of respiratory and heart rates using a fibre-optic sensor
Lindberg, L. G., Ugnell, H., & Öberg, P. Å. (1992) · Medical & Biological Engineering & Computing · doi:10.1007/bf02457833 · Cited by 158
Monitoring of respiratory rate in postoperative care using a new photoplethysmographic technique
Nilsson, L. M., Johansson, A., & Kálmán, S. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1011424732717 · Cited by 157
RELATIONSHIP BETWEEN HYPOXAEMIC AND CARDIAC ISCHAEMIC EVENTS IN THE PERIOPERATIVE PERIOD
Gill, N., WRIGHT, B., & Reilly, C. S. (1992) · British Journal of Anaesthesia · doi:10.1093/bja/68.5.471 · Cited by 157
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Respiration rate monitoring methods: A review
AL‐Khalidi, F. Q., Saatchi, R., Burke, D., Elphick, H., & Tan, S. (2011) · Pediatric Pulmonology · doi:10.1002/ppul.21416 · Cited by 536
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Sensitive Wearable Temperature Sensor with Seamless Monolithic Integration
Shin, J., Jeong, B., Kim, J., Nam, V. B., Yoon, Y., Jung, J., Hong, S., Lee, H., Eom, H., Yeo, J., et al. (2020) · Advanced Materials · doi:10.1002/adma.201905527 · Cited by 449
Contact-Based Methods for Measuring Respiratory Rate
Massaroni, C., Nicolò, A., Lo Presti, D., Sacchetti, M., Silvestri, S., & Schena, E. (2019) · Sensors · doi:10.3390/s19040908 · Cited by 426
Respiration rate and volume measurements using wearable strain sensors
Chu, M., Nguyen, T., Pandey, V., Zhou, Y., Pham, H. N., Bar-Yoseph, R., Radom-Aizik, S., Jain, R., Cooper, D. M., & Khine, M. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0083-3 · Cited by 403
Breath Analysis: Potential for Clinical Diagnosis and Exposure Assessment
Cao, W., & Duan, Y. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.063545 · Cited by 391
Ma, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367
Wang, Z., Yang, Z., & Dong, T. (2017) · Sensors · doi:10.3390/s17020341 · Cited by 355
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Alwis, L., Sun, T., & Grattan, K. T. V. (2013) · Measurement · doi:10.1016/j.measurement.2013.07.030 · Cited by 276
Yetisen, A. K., Butt, H., Volpatti, L. R., Pavlichenko, I., Humar, M., Kwok, S. J. J., Koo, H., Kim, K. S., Naydenova, I., Khademhosseini, A., et al. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.10.005 · Cited by 192
Chee, Y., Han, J., Youn, J., & Park, K. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/007 · Cited by 111
Non-invasive respiration rate monitoring using a single COTS TX-RX pair
Kaltiokallio, O., Yigitler, H., Jantti, R., & Patwari, N. (2014) · IPSN-14 Proceedings of the 13th International Symposium on Information Processing in Sensor Networks · doi:10.1109/ipsn.2014.6846741 · Cited by 101
Nilsson, L., Goscinski, T., Kalman, S., Lindberg, L. ‐., & Johansson, A. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01375.x · Cited by 88
Non-invasive human vital signs monitoring based on twin-core optical fiber sensors
Tan, F., Chen, S., Lyu, W., Liu, Z., Yu, C., Lu, C., & Tam, H.-Y. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005940 · Cited by 62
Age and gender do not influence the ability to detect respiration by photoplethysmography
Nilsson, L., Goscinski, T., Johansson, A., Lindberg, L.-G., & Kalman, S. (2006) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-006-9050-z · Cited by 26
Metadata
- Authors
- Folke, M., Cernerud, L., Ekström, M., & Hök, B.
- Venue
- Medical & Biological Engineering & Computing
- Published
- 2003-07
- Volume
- 41
- Issue
- 4
- Pages
- 377-383
- ISSN
- 0140-0118 (ISSN-L)
- 1741-0444
- OpenAlex
- W2088923975
- Cited by
- 430
- References
- 36
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.