Tapered-Tip Capillary Electrophoresis Nano-Electrospray Ionization Mass Spectrometry for Ultrasensitive Proteomics: the Mouse Cortex
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Ultrasensitive characterization of the proteome raises the potential to understand how differential gene expression orchestrates cell heterogeneity in the brain. Here, we report a microanalytical capillary electrophoresis nano-flow electrospray ionization (CE-nanoESI) interface for mass spectrometry to enable the measurement of limited amounts of proteins in the mouse cortex. Our design integrates a custom-built CE system to a tapered-tip metal emitter in a co-axial sheath-flow configuration. This interface can be constructed in <15 min using readily available components, facilitating broad adaptation. Tapered-tip CE-nanoESI generates stable electrospray by reproducibly anchoring the Taylor cone, minimizes sample dilution in the ion source, and ensures efficient ion generation by sustaining the cone-jet spraying regime. Parallel reaction monitoring provided a 260-zmol lower limit of detection for angiotensin II (156,000 copies). CE was able to resolve a complex mixture of peptides in ~330,000 theoretical plates and identify ~15 amol (~1 pg) of BSA or cytochrome c. Over 30 min of separation, 1 ng protein digest from the mouse cortex yielded 217 nonredundant proteins encompassing a ~3-log-order concentration range using a quadrupole time-of-flight mass spectrometer. Identified proteins included many products from genes that are traditionally used to mark oligodendrocytes, astrocytes, and microglia. Finally, key proteins involved in neurodegenerative disorders were detected (e.g., parkinsonism and spastic paraplegia). CE-nanoESI-HRMS delivers sufficient sensitivity to detect proteins in limited amounts of tissues and cell populations to help understand how gene expression differences maintain cell heterogeneity in the brain. Graphical Abstract ᅟ.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cox, J., Hein, M. Y., Luber, C. A., Paron, I., Nagaraj, N., & Mann, M. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.031591 · Cited by 5,180 · cited 2×
“To estimate the relative abundance of these proteins, we calculated label-free quantification (LFQ) intensities using MaxLFQ [64].”
Cell types in the mouse cortex and hippocampus revealed by single-cell RNA-seq
Zeisel, A., Muñoz-Manchado, A. B., Codeluppi, S., Lönnerberg, P., La Manno, G., Juréus, A., Marques, S., Munguba, H., He, L., Betsholtz, C., et al. (2015) · Science · doi:10.1126/science.aaa1934 · Cited by 3,124 · cited 1×
“Discovery HRMS enabled drafting of the human proteome [5] and, recently, cataloging gene expression diversity between tissues and cell types in the mouse brain [6], complementing cell heterogeneity information at the transcriptomic level [7, 8].”
BackgroundBendall, S. C., Simonds, E. F., Qiu, P., Amir, E.-A. D., Krutzik, P. O., Finck, R., Bruggner, R. V., Melamed, R., Trejo, A., Ornatsky, O. I., et al. (2011) · Science · doi:10.1126/science.1198704 · Cited by 2,279
A draft map of the human proteome
Kim, M.-S., Pinto, S. M., Getnet, D., Nirujogi, R. S., Manda, S. S., Chaerkady, R., Madugundu, A. K., Kelkar, D. S., Isserlin, R., Jain, S., et al. (2014) · Nature · doi:10.1038/nature13302 · Cited by 2,198
Adult mouse cortical cell taxonomy revealed by single cell transcriptomics
Tasic, B., Menon, V., Nguyen, T. N., Kim, T. K., Jarsky, T., Yao, Z., Levi, B., Gray, L. T., Sorensen, S. A., Dolbeare, T., et al. (2016) · Nature Neuroscience · doi:10.1038/nn.4216 · Cited by 1,714 · cited 1×
“Discovery HRMS enabled drafting of the human proteome [5] and, recently, cataloging gene expression diversity between tissues and cell types in the mouse brain [6], complementing cell heterogeneity information at the transcriptomic level [7, 8].”
BackgroundMcAlister, G. C., Nusinow, D. P., Jedrychowski, M. P., Wühr, M., Huttlin, E. L., Erickson, B. K., Rad, R., Haas, W., & Gygi, S. P. (2014) · Analytical Chemistry · doi:10.1021/ac502040v · Cited by 1,263
Cell type- and brain region-resolved mouse brain proteome
Sharma, K., Schmitt, S., Bergner, C. G., Tyanova, S., Kannaiyan, N., Manrique-Hoyos, N., Kongi, K., Cantuti, L., Hanisch, U.-K., Philips, M.-A., et al. (2015) · Nature Neuroscience · doi:10.1038/nn.4160 · Cited by 785
Hebert, A. S., Richards, A. L., Bailey, D. J., Ulbrich, A., Coughlin, E. E., Westphall, M. S., & Coon, J. J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m113.034769 · Cited by 528
Nagaraj, N., Alexander Kulak, N., Cox, J., Neuhauser, N., Mayr, K., Hoerning, O., Vorm, O., & Mann, M. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.013722 · Cited by 392
A complete mass-spectrometric map of the yeast proteome applied to quantitative trait analysis
Picotti, P., Clément-Ziza, M., Lam, H., Campbell, D. S., Schmidt, A., Deutsch, E. W., Röst, H., Sun, Z., Rinner, O., Reiter, L., et al. (2013) · Nature · doi:10.1038/nature11835 · Cited by 318
Sun, L., Zhu, G., Zhang, Z., Mou, S., & Dovichi, N. J. (2015) · Journal of Proteome Research · doi:10.1021/acs.jproteome.5b00100 · Cited by 216 · cited 2×
“Most recently, 1249 different proteins were identified from 300 ng digest from the Xenopus laevis fertilized egg [47] and 2313 phosphorylated peptides in 200 ng protein from human mammary cells [48] in discovery MS.”
BackgroundLombard‐Banek, C., Moody, S. A., & Nemes, P. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201510411 · Cited by 214 · cited 7×
“This sensitivity is ~70-fold higher compared with our previous blunt-tip CE-μESI design [55, 56].”
BackgroundMethodResultSelf-citationUltrasensitive and Fast Bottom‐up Analysis of Femtogram Amounts of Complex Proteome Digests
Sun, L., Zhu, G., Zhao, Y., Yan, X., Mou, S., & Dovichi, N. J. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201308139 · Cited by 212 · cited 3×
“coli [45] in a bottom-up and 30 proteins from P.”
BackgroundWang, Y., Fonslow, B. R., Wong, C. C. L., Nakorchevsky, A., & Yates, J. R. (2012) · Analytical Chemistry · doi:10.1021/ac301091m · Cited by 144 · cited 1×
“These peptides were separated within a relatively short (~20-min) time window (see bottom panel), agreeing with similarly compact separation also noted in other bottom-up proteomic studies by CE [36, 45, 48, 56].”
BackgroundOptimizing capillary electrophoresis for top‐down proteomics of 30–80 kDa proteins
Li, Y., Compton, P. D., Tran, J. C., Ntai, I., & Kelleher, N. L. (2014) · PROTEOMICS · doi:10.1002/pmic.201300381 · Cited by 95
Bush, D. R., Zang, L., Belov, A. M., Ivanov, A. R., & Karger, B. L. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b03218 · Cited by 92
Han, X., Wang, Y., Aslanian, A., Bern, M., Lavallée-Adam, M., & Yates, J. R. (2014) · Analytical Chemistry · doi:10.1021/ac503439n · Cited by 77
Quantitative Proteomics Using Ultralow Flow Capillary Electrophoresis–Mass Spectrometry
Faserl, K., Kremser, L., Müller, M., Teis, D., & Lindner, H. H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00312 · Cited by 57 · cited 1×
“, by on-column immobilized microreactors [67], fractionation [68], and focused acoustics-assisted sample preparation [23]) can help extend the detectable coverage of the encoded proteome to single cells.”
BackgroundLudwig, K. R., Sun, L., Zhu, G., Dovichi, N. J., & Hummon, A. B. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02457 · Cited by 56 · cited 2×
“These peptides were separated within a relatively short (~20-min) time window (see bottom panel), agreeing with similarly compact separation also noted in other bottom-up proteomic studies by CE [36, 45, 48, 56].”
BackgroundZhao, Y., Riley, N. M., Sun, L., Hebert, A. S., Yan, X., Westphall, M. S., Rush, M. J. P., Zhu, G., Champion, M. M., Medie, F. M., et al. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00883 · Cited by 55
Guo, X., Fillmore, T. L., Gao, Y., & Tang, K. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.5b04912 · Cited by 54 · cited 1×
“Most recently, 5-amol detection was accomplished for targeted peptides by directly hyphenating a CE capillary to an ESI emitter [37].”
MethodWang, C., Lee, C. S., Smith, R. D., & Tang, K. (2013) · Analytical Chemistry · doi:10.1021/ac401202c · Cited by 46 · cited 1×
“The porous-junction interface [33] enhanced robustness and sensitivity to 30 amol lower limit of detection for peptides and protein standards [34, 35], detecting 385 proteins from 5 ng digest of the extremophile P.”
Background
Cited by
Stolz, A., Jooß, K., Höcker, O., Römer, J., Schlecht, J., & Neusüß, C. (2019) · ELECTROPHORESIS · doi:10.1002/elps.201800331 · Cited by 214
Capillary zone electrophoresis-mass spectrometry for bottom-up proteomics
Zhang, Z., Qu, Y., & Dovichi, N. J. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2018.08.008 · Cited by 61
Höcker, O., Montealegre, C., & Neusüß, C. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1179-3 · Cited by 55
Recent advances of capillary electrophoresis-mass spectrometry instrumentation and methodology
Jiang, Y., He, M.-Y., Zhang, W.-J., Luo, P., Guo, D., Fang, X., & Xu, W. (2017) · Chinese Chemical Letters · doi:10.1016/j.cclet.2017.05.008 · Cited by 30
Metadata
- Authors
- Choi, S. B., Zamarbide, M., Manzini, M. C., & Nemes, P.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-11-16
- Volume
- 28
- Issue
- 4
- Pages
- 597-607
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2553300693
- Cited by
- 59
- References
- 22
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.