Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 143

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Technological advances in electrochemical biosensors for the detection of disease biomarkers

Kim, Jae Hyun, Suh, Young Joon, Park, Dongsung, Yim, Hyoju, Kim, Hongrae, Kim, Hye Jin, Yoon, Dae Sung, Hwang, Kyo Seon · 2021 · Biomedical Engineering Letters

Abstract

With an increasing focus on health in contemporary society, interest in the diagnosis, treatment, and prevention of diseases has grown rapidly. Accordingly, the demand for biosensors for the early diagnosis of disease is increasing. However, the measurement range of existing electrochemical sensors is relatively high, which is not suitable for early disease diagnosis, requiring the detection of small amounts of biocomponents. Various attempts have been made to overcome this and amplify the signal, including binding with various labeling molecules, such as DNA, enzymes, nanoparticles, and carbon materials. Efforts are also being made to increase the sensitivity of electrochemical sensors, and the combination of nanomaterials, materials, and biotechnology offers the potential to increase sensitivity in a variety of ways. Recent studies suggest that electrochemical sensors can be a powerful tool in providing comprehensive insights into the targeting and detection of disease-associated biomarkers. Significant advances in nanomaterial and biomolecule approaches for improved sensitivity have resulted in the development of electrochemical biosensors capable of detecting multiple biomarkers in real time in clinically relevant samples. In this review, we have discussed the recent studies on electrochemical sensors for detection of diseases such as diabetes, degenerative diseases, and cancer. Further, we have highlighted new technologies to improve sensitivity using various materials, including DNA, enzymes, nanoparticles, and carbon materials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1007/s13534-021-00204-w

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Research works printed but not linked: 133

  1. Lee TM. Over-the-counter biosensors: past, present, and future. Sensors. 2008;8(9):5535–59. · DOI
  2. Marrugo-Ramírez J, Mir M, Samitier J. Blood-based cancer biomarkers in liquid biopsy: a promising non-invasive alternative to tissue biopsy. Int J Mol Sci. 2018;19(10):2877. · DOI · Paper page
  3. Ronkainen NJ, Halsall HB, Heineman WR. Electrochemical biosensors. Chem Soc Rev. 2010;39(5):1747–63. · DOI · Paper page
  4. Wang J. Electrochemical biosensors: towards point-of-care cancer diagnostics. Biosens Bioelectron. 2006;21(10):1887–92. · DOI · Paper page
  5. Shrivastav AM, Cvelbar U, Abdulhalim I. A comprehensive review on plasmonic-based biosensors used in viral diagnostics. Commun Biol. 2021;4(1):70. · DOI · Paper page
  6. Ausó E, Gómez-Vicente V, Esquiva G. Biomarkers for Alzheimer’s disease early diagnosis. J Pers Med. 2020;10(3):114. · DOI
  7. Reddy KK, Bandal H, Satyanarayana M, Goud KY, Gobi KV, Jayaramudu T, Amalraj J, Kim H. Recent trends in electrochemical sensors for vital biomedical markers using hybrid nanostructured materials. Adv Sci. 2020;7(13):1902980. · DOI
  8. Naresh V, Lee N. A review on biosensors and recent development of nanostructured materials-enabled biosensors. Sensors. 2021;21(4):1109. · DOI · Paper page
  9. Hammond JL, Formisano N, Estrela P, Carrara S, Tkac J. Electrochemical biosensors and nanobiosensors. Essays Biochem. 2016;60(1):69–80. · DOI · Paper page
  10. Chen M, Wu D, Tu S, Yang C, Chen DJ, and Xu Y. CRISPR/Cas9 cleavage triggered ESDR for circulating tumor DNA detection based on a 3D graphene/AuPtPd nanoflower biosensor. Biosens Bioelectron. 2021;173:112821. · DOI
  11. Kim JH, Hong SG, Wee Y, Hu S, Kwon Y, Ha S, Kim J. Enzyme precipitate coating of pyranose oxidase on carbon nanotubes and their electrochemical applications. Biosens Bioelectron. 2017;87:365–72. · DOI
  12. Chowdhury AD, Takemura K, Li TC, Suzuki T, Park EY. Electrical pulse-induced electrochemical biosensor for hepatitis E virus detection. Nat Commun. 2019;10(1):3737. · DOI · Paper page
  13. Chen M, Wu D, Tu S, Yang C, Chen D, Xu Y. A novel biosensor for the ultrasensitive detection of the lncRNA biomarker MALAT1 in non-small cell lung cancer. Sci Rep. 2021;11(1):3666. · doi:10.1038/s41598-021-83244-7
  14. Patel S, Nanda R, Sahoo S, Mohapatra E. Biosensors in health care: the milestones achieved in their development towards lab-on-chip-analysis. Biochem Res Int. 2016;2016:3130469. · doi:10.1155/2016/3130469
  15. Teymourian H, Barfidokht A, Wang J. Electrochemical glucose sensors in diabetes management: an updated review (2010–2020). Chem Soc Rev. 2020;49(21):7671–709. · DOI · Paper page
  16. Chia HL, Sturala J, Webster RD, Pumera M. Functionalized 2D Germanene and silicene enzymatic system. Adv Funct Mater. 2021;31(16):2011125. · DOI
  17. Ojeda I, Barrejón M, Arellano LM, González-Cortés A, Yáñez-Sedeño P, Langa F, Pingarrón JM. Grafted-double walled carbon nanotubes as electrochemical platforms for immobilization of antibodies using a metallic-complex chelating polymer: application to the determination of Adiponectin Cytokine in Serum. Biosens Bioelectron. 2015;74:24–9. · DOI
  18. Lenters-Westra E, Schindhelm RK, Bilo HJ, Slingerland RJ. Haemoglobin A1c: historical overview and current concepts. Diabetes Res Clin Pract. 2012;99(2):75–84. · DOI
  19. Pundir CS, Chawla S. Determination of glycated hemoglobin with special emphasis on biosensing methods. Anal Biochem. 2014;444:47–56. · DOI
  20. Kim DM, Shim YB. Disposable amperometric glycated hemoglobin sensor for the finger prick blood test. Anal Chem. 2014;85(13):6536–43. · DOI
  21. Wang X, Su J, Zeng D, Liu G, Liu L, Xu Y, Wang C, Liu X, Wang L, Mi X. Gold nano-flowers (Au NFs) modified screen-printed carbon electrode electrochemical biosensor for label-free and quantitative detection of glycated hemoglobin. Talanta. 2019;201:119–25. · DOI
  22. Gitler AD, Dhillon P, Shorter J. Neurodegenerative disease: models, mechanisms, and a new hope. Dis Model Mech. 2017;10(5):499–502. · DOI · Paper page
  23. Cicero CE, Mostile G, Vasta R, Rapisarda V, Signorelli SS, Ferrante M, Zappia M, Nicoletti A. Metals and neurodegenerative diseases. A Syst Rev Environ Res. 2017;159:82–94. · DOI · Paper page
  24. Song Z, Zhou Y, Han X, Qin J, Tang X. Recent advances in enzymeless-based electrochemical sensors to diagnose neurodegenerative diseases. J Mater Chem B. 2021;9(5):1175–88. · DOI
  25. Duan Y, Chen J, Jin Y, Tu Q, Wang S, Xiang J. Antibody-free determinations of low-mass, soluble oligomers of Aβ 42 and Aβ 40 by planar bilayer lipid membrane-based electrochemical biosensor. Anal Chem. 2021;93(7):3611–7. · DOI
  26. Shoji M, Kanai M. Cerebrospinal fluid Aβ40 and Aβ42: natural course and clinical usefulness. J Alzheimers Dis. 2001;3(3):313–21. · DOI
  27. Yu Y, Zhang L, Li C, Sun X, Tang D, Shi G. A method for evaluating the level of soluble β-amyloid (1–40/1-42) in Alzheimer’s disease based on the binding of gelsolin to β-amyloid peptides. Angew Chem Int Ed Engl. 2014;53(47):12832–5. · DOI
  28. Qin J, Kim S, Cho M, Lee Y. Hierarchical and ultra-sensitive amyloid beta oligomer sensor for practical applications. Chem Eng J. 2020;401:126055. · DOI
  29. Verwilst P, Kim HS, Kim S, Kang C, Kim JS. Shedding light on tau protein aggregation: the progress in developing highly selective fluorophores. Chem Soc Rev. 2018;47(7):2249–65. · DOI
  30. Olsson B, Lautner R, Andreasson U, Öhrfelt A, Portelius E, Bjerke M, Hölttä M, Rosén C, Olsson C, Strobel G, Wu E, Dakin K, Petzold M, Blennow K, Zetterberg H. CSF and blood biomarkers for the diagnosis of Alzheimer’s disease: a systematic review and meta-analysis. Lancet Neurol. 2016;15(7):673–84. · DOI · Paper page
  31. Kim K, Park CB. Femtomolar sensing of Alzheimer’s tau proteins by water oxidation-coupled photoelectrochemical platform. Biosens Bioelectron. 2020;154(11):112075. · DOI
  32. Zhang C, Liu Z, Zhang L, Zhu A, Liao F, Wan J, Zhou J, Tian Y. A robust Au−C≡C functionalized surface: toward real-time mapping and accurate quantification of Fe 2 in the brains of live AD mouse models. Angew Chem Int Ed. 2020;59(16):20499–507. · DOI
  33. Ganesh HVS, Chow AM, Kerman K. Recent advances in biosensors for neurodegenerative disease detection. Trends Analyt Chem. 2016;79:363–70. · DOI
  34. Xu Q, Cheng H, Lehr J, Patil AV, Davis JJ. Graphene oxide interfaces in serum based autoantibody quantification. Anal Chem. 2015;87(1):346–50. · DOI
  35. Ali SR, Ma Y, Parajuli RR, Balogun Y, He H. A Nonoxidative Sensor Based on a Self-Doped Polyaniline/Carbon Nanotube Composite for Sensitive and Selective Detection of the Neurotransmitter Dopamine. Anal Chem. 2007;79(6):2583–7. · DOI · Paper page
  36. Chang Y, Chen Y, Shao Y, Li B, Wu Y, Zhang W, Zhou Y, Yu Z, Lu L, Wang X, Guo G. Solid-phase microextraction integrated nanobiosensors for the serial detection of cytoplasmic dopamine in a single living cell. Biosens Bioelectron. 2021;175:112915. · DOI
  37. Aziz A, Asif M, Azeem M, Ashraf G, Wang Z, Xiao F, Liu H. Self-stacking of exfoliated charged nanosheets of LDHs and graphene as biosensor with real-time tracking of dopamine from live cells. Anal Chim Acta. 2019;1047:197–207. · DOI
  38. Bai J, Jiang X. A facile one-pot synthesis of copper sulfide-decorated reduced graphene oxide composites for enhanced detecting of H 2 O 2 in biological environments. Anal Chem. 2013;85(17):8095–101. · DOI · Paper page
  39. Wang L, Zhang Y, Cheng C, Liu X, Jiang H, Wang X. Highly sensitive electrochemical biosensor for evaluation of oxidative stress based on the nanointerface of graphene nanocomposites blended with gold, Fe3O4, and platinum nanoparticles. ACS Appl Mater Interfaces. 2015;7(33):18441–9. · DOI
  40. Dong H, Zhou Y, Hao Y, Zhao L, Sun S, Zhang Y, Ye B, Xu M. “Turn-on” ratiometric electrochemical detection of H2O2 in one drop of whole blood sample via a novel microelectrode sensor. Biosens Bioelectron. 2020;165:1102. · DOI
  41. Ottervald J, Franzén B, Nilsson K, Andersson LI, Khademi M, Eriksson B, Kjellström S, Marko-Varga G, Végvári A, Harris RA, Laurell T, Miliotis T, Matusevicius D, Salter H, Ferm M, Olsson T. Multiple sclerosis: identification and clinical evaluation of novel CSF biomarkers. J Proteomics. 2010;73(6):1117–32. · DOI
  42. Reindl M, Linington C, Brehm U, Egg R, DIlitz E, Deisenhammer F, Poewe W, Berger T, . Antibodies against the myelin oligodendrocyte glycoprotein and the myelin basic protein in multiple sclerosis and other neurological diseases: a comparative study. Brain. 1999;122(11):2047–56. · DOI · Paper page
  43. Derkus B, Emregul E, Yucesan C, Emregul KC. Myelin basic protein immunosensor for multiple sclerosis detection based upon label-free electrochemical impedance spectroscopy. Biosens Bioelectron. 2013;46:53–60. · doi:10.1016/j.bios.2013.01.060
  44. Peer D, Karp JM, Hong S, Farokhzad OC, Margalit R, Langer R. Nanocarriers as an emerging platform for cancer therapy. Nat Nanotechnol. 2007;2(12):751–60. · DOI · Paper page
  45. Wardle J, Robb K, Vernon S, Waller J. Screening for prevention and early diagnosis of cancer. Am Psychol. 2015;70(2):119–33. · DOI · Paper page
  46. Shen Q, Rahn JJ, Zhang J, Gunasekera N, Sun X, Shaw AR, Hendzel MJ, Hoffman P, Bernier A, Hugh JC. MUC1 initiates Src-CrkL-Rac1/Cdc42-mediated actin cytoskeletal protrusive motility after ligating intercellular adhesion molecule-1. Mol Cancer Res. 2008;6(4):555–67. · DOI
  47. Jezersek B, Cervek J, Rudolf Z, Novaković S. Clinical evaluation of potential usefulness of CEA, CA 15–3, and MCA in follow-up of breast cancer patients. Cancer Lett. 1996;110(1–2):137–44. · doi:10.1016/s0304-3835(96)04473-4
  48. Li T, Fan Q, Liu T, Zhu X, Zhao J, Li G. Detection of breast cancer cells specially and accurately by an electrochemical method. Biosens Bioelectron. 2010;25(12):2686–9. · doi:10.1016/j.bios.2010.05.004
  49. Colomer R, Aranda-López I, Albanell J, García-Caballero T, Ciruelos E, López-García MÁ, Cortés J, Rojo F, Martín M, Palacios-Calvo J. Biomarkers in breast cancer: a consensus statement by the Spanish Society of Medical Oncology and the Spanish Society of Pathology. Clin Transl Oncol. 2018;20(7):815–26. · DOI
  50. Rauf S, Lahcen AA, Aljedaibi A, Beduk T, de Oliveira Filho IJ, Salama KN. Gold nanostructured laser-scribed graphene: A new electrochemical biosensing platform for potential point-of-care testing of disease biomarkers. Biosens Bioelectron. 2021;180:1116. · doi:10.1016/j.bios.2021.113116
  51. Qi W, Li X, Kang J. Advances in the study of serum tumor markers of lung cancer. J Cancer Res Ther. 2014;10(Suppl):C95–101.
  52. Aydin EB, Aydin M, Sezginturk MK. Selective and ultrasensitive electrochemical immunosensing of NSE cancer biomarker in human serum using epoxy-substituted poly(pyrrole) polymer modified disposable ITO electrode. Sens Actuators B Chem. 2020;306:127613. · doi:10.1016/j.snb.2019.127613
  53. Yang G, Xiao Z, Tang C, Deng Y, Huang H, He Z. Recent advances in biosensor for detection of lung cancer biomarkers. Biosens Bioelectron. 2019;141:111416. · DOI · Paper page
  54. Wang H, Rong Q, Ma Z. Polyhydroquinone-graphene composite as new redox species for sensitive electrochemical detection of cytokeratins antigen 21–1. Sci Rep. 2016;6:30623. · doi:10.1038/srep30623
  55. Yang H, Bao J, Huo D, Zeng Y, Wang X, Samalo M, Zhao J, Zhang S, Shen C, Hou C. Au doped poly-thionine and poly-m-Cresol purple: synthesis and their application in simultaneously electrochemical detection of two lung cancer markers CEA and CYFRA21–1. Talanta. 2021;224:1216. · DOI
  56. Castle JC, Loewer M, Boegel S, de Graaf J, Bender C, Tadmor AD, Boisguerin V, Bukur T, Sorn P, Paret C, Diken M, Kreiter S, Türeci Ö, Sahin U. Immunomic, genomic and transcriptomic characterization of CT26 colorectal carcinoma. BMC Genom. 2014;15(1):190. · DOI · Paper page
  57. Hashkavayi AB, Raoof JB, Ojani R, Kavoosian S. Ultrasensitive electrochemical aptasensor based on sandwich architecture for selective label-free detection of colorectal cancer (CT26) cells. Biosens Bioelectron. 2017;92:630–7. · DOI
  58. Duan F, Hu M, Guo C, Song Y, Wang M, He L, Zhang Z, Pettinari R, Zhou L. Chromium-based Metal-organic Framework Embedded with Cobalt Phthalocyanine for the Sensitively Impedimetric Cytosensing of Colorectal Cancer (CT26) Cells and Cell Imaging. Chem Eng J. 2020;398:125452. · DOI
  59. Cheshomi H, Matin MM. Exosomes and their importance in metastasis, diagnosis, and therapy of colorectal cancer. J Cell Biochem. 2019;120:2671–86. · DOI
  60. Wang M, Pan Y, Wu S, Sun Z, Wang L, Yang J, Yin Y, Li G. Detection of colorectal cancer-derived exosomes based on covalent organic frameworks. Biosens Bioelectron. 2020;169:112638. · DOI
  61. Tirnitz-Parker JEE. Hepatocellular carcinoma. Codon Publications; 2019. · DOI
  62. Bialecki ES, Di Bisceglie AM. Diagnosis of hepatocellular carcinoma. HPB. 2005;7(1):26–34. · DOI · Paper page
  63. Ding C, Zhao F, Ren R, Lin JM. An electrochemical biosensor for alpha-fetoprotein based on carbon paste electrode constructed of room temperature ionic liquid and gold nanoparticles. Talanta. 2009;78(3):1148–54. · doi:10.1016/j.talanta.2009.01.036
  64. Cao J, Ouyang P, Yu S, Shi F, Ren C, Wang C, Shen M, Yang Z. Hedgehog-like Bi2S3 nanostructures: a novel composite soft template route to the synthesis and sensitive electrochemical immunoassay of the liver cancer biomarker. Chem Commun (Camb). 2021;57(14):1766–9. · DOI
  65. Singh S, Gill AAS, Nlooto M, Karpoormath R. Prostate cancer biomarkers detection using nanoparticles based electrochemical biosensors. Biosens Bioelectron. 2019;137:213–21. · DOI
  66. Pan LH, Kuo SH, Lin TY, Lin CW, Fang PY, Yang HW. An electrochemical biosensor to simultaneously detect VEGF and PSA for early prostate cancer diagnosis based on graphene oxide/ssDNA/PLLA nanoparticles. Biosens Bioelectron. 2017;89(1):598–605. · DOI · Paper page
  67. Gaspar MJ, Arribas I, Coca MC, Díez-Alonso M. Prognostic value of carcinoembryonic antigen, CA 19–9 and CA 72–4 in gastric carcinoma. Tumour Biol. 2001;22(5):318–22. · DOI
  68. Wu D, Guo Z, Liu Y, Guo A, Lou W, Fan D, Wei Q. Sandwich-type electrochemical immunosensor using dumbbell-like nanoparticles for the determination of gastric cancer biomarker CA72-4. Talanta. 2015;134:305–9. · doi:10.1016/j.talanta.2014.11.025
  69. Fan H, Guo Z, Gao L, Zhang Y, Fan D, Ji G, Du B, Wei Q. Ultrasensitive electrochemical immunosensor for carbohydrate antigen 72–4 based on dual signal amplification strategy of nanoporous gold and polyaniline-Au asymmetric multicomponent nanoparticles. Biosens Bioelectron. 2015;64:51–6. · doi:10.1016/j.bios.2014.08.043
  70. Mohapatra S, Patra D, Satpathy S. An ensemble classifier system for early diagnosis of acute lymphoblastic leukemia in blood microscopic images. Neural Comput Appl. 2014;24(7):1887–904. · DOI · Paper page
  71. Khoshroo A, Hosseinzadeh L, Adib K, Rahimi-Nasrabadi M, Ahmadi F. Earlier diagnoses of acute leukemia by a sandwich type of electrochemical aptasensor based on copper sulfide-graphene composite. Anal Chim Acta. 2021;1146:1–10. · doi:10.1016/j.aca.2020.12.007
  72. Hu B, Guo H, Zhou P, Shi ZL. Characteristics of SARS-CoV-2 and COVID-19. Nat Rev Microbiol. 2021;19(3):141–54. · DOI · Paper page
  73. Morales-Narváez E, Dincer C. The impact of biosensing in a pandemic outbreak: COVID-19. Biosens Bioelectron. 2020;163:112274. · DOI
  74. Yakoh A, Pimpitak U, Rengpipat S, Hirankarn N, Chailapakul O, Chaiyo S. Paper-based electrochemical biosensor for diagnosing COVID-19: Detection of SARS-CoV-2 antibodies and antigen. Biosens Bioelectron. 2021;176:112912. · DOI · Paper page
  75. Chaibun T, Puenpa J, Ngamdee T, Boonapatcharoen N, Athamanolap P, O’Mullane AP, Vongpunsawad S, Poovorawan Y, Lee SY, Lertanantawong B. Rapid electrochemical detection of coronavirus SARS-CoV-2. Nat Commun. 2021;12(1):802. · DOI · Paper page
  76. Cady NC, Tokranova N, Minor A, Nikvand N, Strle K, Lee WT, Page W, Guignon E, Pilar A, Gibson GN. Multiplexed detection and quantification of human antibody response to COVID-19 infection using a plasmon enhanced biosensor platform. Biosens Bioelectron. 2021;171:112679. · DOI
  77. Zhang C, Du X. Electrochemical sensors based on carbon nanomaterial used in diagnosing metabolic disease. Front Chem. 2020;8:651. · DOI
  78. Ansari SA, Husain Q. Potential applications of enzymes immobilized on/in nano materials: a review. Biotechnol Adv. 2012;30(3):512–23. · DOI · Paper page
  79. Luo X, Morrin A, Killard AJ, Smyth MR. Application of nanoparticles in electrochemical sensors and biosensors. Electroanalysis. 2006;18(4):319–26. · DOI · Paper page
  80. Kim JH, Hong SG, Sun HJ, Ha S, Kim J. Precipitated and chemically-crosslinked laccase over polyaniline nanofiber for high performance phenol sensing. Chemosphere. 2016;143:142–7. · doi:10.1016/j.chemosphere.2015.08.011
  81. Liu Y, Liu Y, Qiao L, Liu Y, Liu B. Advances in signal amplification strategies for electrochemical biosensing. Curr Opin Electrochem. 2018;12:5–12. · doi:10.1016/j.coelec.2018.05.001
  82. Roh S, Chung T, Lee B. Overview of the characteristics of micro- and nano-structured surface plasmon resonance sensors. Sensors. 2011;11(2):1565–88. · doi:10.3390/s110201565
  83. Diculescu VC, Chiorcea-Paquim A, Oliveira-Brett A. Applications of a DNA-electrochemical Biosensor. Trac-Trend Anal Chem (Regular Ed). 2016;79:23–36. · DOI · Paper page
  84. Majumdar S, Thakur D, Chowdhury D. DNA carbon-nanodots based electrochemical biosensor for detection of mutagenic nitrosamines. ACS Appl Bio Mater. 2020;3(3):1796–803. · DOI
  85. Forterre A, Komuro H, Aminova S, Harada M. A Comprehensive review of cancer MicroRNA therapeutic delivery strategies. Cancers. 2020;12(7):1852. · DOI · Paper page
  86. Moccia M, Caratelli V, Cinti S, Pede B, Avitabile C, Saviano M, Imbriani AL, Moscone D, Arduini F. Paper-based electrochemical peptide nucleic acid (PNA) biosensor for detection of miRNA-492: a pancreatic ductal adenocarcinoma biomarker. Biosens Bioelectron. 2020;165:112371. · DOI
  87. Masud MK, Na J, Lin TE, Malgras V, Preet A, Ibn Sina AA, Wood K, Billah M, Kim J, You J, Kani K, Whitten AE, Salomon C, Nguyen NT, Shiddiky MJA, Trau M, HossainMd SA, Yamauchi Y. Nanostructured mesoporous gold biosensor for microRNA detection at attomolar level. Biosens Bioelectron. 2020;168:1129. · DOI
  88. Chen S-C, Chen K-T, Jou AF-J. Polydopamine-gold composite-based electrochemical biosensor using dual-amplification strategy for detecting pancreatic cancer-associated microRNA. Biosens Bioelectron. 2021;173:112815. · DOI
  89. Zhou L, Wang T, Bai Y, Li Y, Qiu J, Yu W, Zhang S. Dual-amplified Strategy for Ultrasensitive Electrochemical Biosensor Based on Click Chemistry-mediated Enzyme-assisted Target Recycling and Functionalized Fullerene Nanoparticles in the Detection of MicroRNA-141. Biosens Bioelectron. 2020;150:1164. · DOI
  90. Wang G, Huang Y, Wang LL, Zhang YF, Xu J, Zhou Y, Lourenco GF, Zhang B, Wang Y, Ren RJ, Halliday GM, Chen SD. MicroRNA-146a suppresses ROCK1 allowing hyperphosphorylation of tau in Alzheimer’s disease. Sci Rep. 2016;6:26697. · DOI
  91. Khalilzadeh B, Rashidi M, Soleimanian A, Tajalli H, Kanberoglu GS, Baradaran B, Rashidi MR. Development of a reliable microRNA based electrochemical genosensor for monitoring of miR-146a, as key regulatory agent of neurodegenerative disease. Int J Biol Macromol. 2019;134:695–703. · DOI
  92. Lu J, Wang J, Hu X, Gyimah E, Yakubu S, Wang K, Wu X, Zhang Z. Electrochemical biosensor based on tetrahedral DNA nanostructures and G-Quadruplex–Hemin conformation for the ultrasensitive detection of MICRORNA-21 in Serum. Anal Chem. 2019;91(11):7353–9. · DOI
  93. Li X, Li X, Li D, Zhao M, Wu H, Shen B, Liu P, Ding S. Electrochemical biosensor for ultrasensitive exosomal MiRNA analysis by cascade primer exchange reaction and MOF@Pt@MOF nanozyme. Biosens Bioelectron. 2020;168:112554. · DOI · Paper page
  94. Wu J, Lv W, Yang Q, Li H, Li F. Label-free homogeneous electrochemical detection of microRNA based on target-induced anti-shielding against the catalytic activity of two-dimension nanozyme. Biosens Bioelectron. 2021;171:112707. · doi:10.1016/j.bios.2020.112707
  95. Keller L, Belloum Y, Wikman H, Pantel K. Clinical relevance of blood-based CtDNA analysis: mutation detection and beyond. Br J Cancer. 2020;124(2):345–58. · DOI · Paper page
  96. Chen K, Zhao H, Wang Z, Lan M. A novel signal amplification label based on AuPt alloy nanoparticles supported by high-active carbon for the electrochemical detection of circulating tumor DNA. Anal Chim Acta. 2021;1169:338628. · doi:10.1016/j.aca.2021.338628
  97. Campaña AL, Florez SL, Noguera MJ, Fuentes OP, Puentes PR, Cruz JC, Osma JF. Enzyme-based electrochemical biosensors for microfluidic platforms to detect pharmaceutical residues in wastewater. Biosensors. 2019;9(1):41. · DOI
  98. Li X, Feng Q, Lu K, Huang J, Zhang Y, Hou Y, Qiao H, Li D, Wei Q. Encapsulating enzyme into metal-organic framework during in-situ growth on cellulose acetate nanofibers as self-powered glucose biosensor. Biosens Bioelectron. 2021;171:1190. · DOI
  99. Yan Y, Qiao Z, Hai X, Song W, Bi S. Versatile electrochemical biosensor based on bi-enzyme cascade biocatalysis spatially regulated by DNA architecture. Biosens Bioelectron. 2021;174:112827. · doi:10.1016/j.bios.2020.112827
  100. Takeda K, Kusuoka R, Inukai M, Igarashi K, Ohno H, Nakamura N. An amperometric biosensor of L-fucose in urine for the first screening test of cancer. Biosens Bioelectron. 2021;174:112831. · DOI
  101. Chen L, Wu J, Yan F, Ju H. A facile strategy for quantitative sensing of glycans on cell surface using organic electrochemical transistors. Biosens Bioelectron. 2021;175:112878. · DOI
  102. Hiraka K, Tsugawa W, Asano R, Yokus MA, Ikebukuro K, Daniele MA, Sode K. Rational design of direct electron transfer type l-lactate dehydrogenase for the development of multiplexed biosensor. Biosens Bioelectron. 2021;176:112933. · DOI
  103. Xia T, Liu G, Wang J, Hou S, Hou S. MXene-based enzymatic sensor for highly sensitive and selective detection of cholesterol. Biosens Bioelectron. 2021;183:113243. · DOI
  104. Kucherenko IS, Soldatkin OO, Kucherenko DY, Soldatkina OV, Dzyadevych SV. Advances in nanomaterial application in enzymebased electrochemical biosensors: a review. Nanoscale Adv. 2019;1:4560–77. · DOI · Paper page
  105. Pingarrón JM, Yáñez-Sedeño P, González-Cortés A. Gold nanoparticle-based electrochemical biosensors. Electrochim Acta. 2008;53(19):5848–66. · DOI · Paper page
  106. Miao J, Du K, Li X, Xu X, Dong X, Fang J, Cao W, Wei Q. Ratiometric electrochemical immunosensor for the detection of procalcitonin based on the ratios of SiO2-Fc-COOH-Au and UiO-66-TB complexes. Biosens Bioelectron. 2021;171:112713. · doi:10.1016/j.bios.2020.112713
  107. Du X, Zhang Z, Zheng X, Zhang H, Dong D, Zhang Z, Liu M, Zhou J. An electrochemical biosensor for the detection of epithelial-mesenchymal transition. Nat Commun. 2020;11(1):192. · DOI
  108. Xing Y, Feng XZ, Zhang L, Hou J, Han GC, Chen Z. A sensitive and selective electrochemical biosensor for the determination of beta-amyloid oligomer by inhibiting the peptide-triggered in situ assembly of silver nanoparticles. Int J Nanomed. 2017;12:3171–9. · DOI
  109. Liu J, Siavash Moakhar R, Sudalaiyadum Perumal A, Roman HN, Mahshid S, Wachsmann-Hogiu S. An AgNP-deposited commercial electrochemistry test strip as a platform for urea detection. Sci Rep. 2020;10(1):9527. · DOI
  110. Hou L, Huang Y, Hou W, Yan Y, Liu J, Xia N. Modification-free amperometric biosensor for the detection of wild-type p53 protein based on the in-situ formation of silver nanoparticle networks for signal amplification. Int J Biol Macromol. 2020;158:580–6. · DOI
  111. Tai MJY, Perumal V, Gopinath SCB, Raja PB, Ibrahim MNM, Jantan IN, Suhaimi NSH, Liu WW. Laser-scribed graphene nanofiber decorated with oil palm lignin capped silver nanoparticles: a green biosensor. Sci Rep. 2021;11(1):5475. · doi:10.1038/s41598-021-85039-2
  112. Nguyen TNH, Nolan JK, Park H, Lam S, Fattah M, Page JC, Joe HE, Jun MBG, Lee H, Kim SJ, Shi R, Lee H. Facile fabrication of flexible glutamate biosensor using direct writing of platinum nanoparticle-based nanocomposite ink. Biosens Bioelectron. 2019;131:257–66. · DOI
  113. Wu H, Shi C, Zhu Q, Li Y, Xu Z, Wei C, Chen D, Huang X. Capillary-driven blood separation and in-situ electrochemical detection based on 3D conductive gradient hollow fiber membrane. Biosens Bioelectron. 2021;171:112722. · DOI
  114. Ji X, Wang H, Song B, Chu B, He Y. Silicon nanomaterials for biosensing and bioimaging analysis. Front Chem. 2018;6:38. · DOI
  115. Kholafazad Kordasht H, Pazhuhi M, Pashazadeh-Panahi P, Hasanzadeh M, Shadjou N. Multifunctional aptasensors based on mesoporous silica nanoparticles as an efficient platform for bioanalytical applications: recent advances. Trac-Trend Anal Chem. 2020;124:115778. · DOI
  116. Liu Y-C, Hsu W-F, Wu T-M. Electrochemical determination of dopamine using a conductive polypyrrole/carbon-coated mesoporous silica composite electrode. J Appl Electrochem. 2020;50(3):311–9. · doi:10.1007/s10800-019-01391-2
  117. Cho IH, Kim DH, Park S. Electrochemical biosensors: perspective on functional nanomaterials for on-site analysis. Biomater Res. 2020;24:6. · DOI · Paper page
  118. Lee JY, Cho D, Cho S-P, Choi J-H, Sung SJ, Hong S, Yu W-R. Semiconducting carbon nanotube fibers for electrochemical biosensor platforms. Mater Des. 2020;192:1040. · DOI
  119. Chapin AA, Rajasekaran PR, Quan DN, et al. Electrochemical measurement of serotonin by Au-CNT electrodes fabricated on microporous cell culture membranes. Microsyst Nanoeng. 2020;6:90. · DOI
  120. Ortiz E, Gallay P, Galicia L, Eguílaz M, Rivas G. Nanoarchitectures based on multi-walled carbon nanotubes non-covalently functionalized with Concanavalin A: A new building-block with supramolecular recognition properties for the development of electrochemical biosensors. Sens Actuator B-Chem. 2019;292:254–62. · doi:10.1016/j.snb.2019.04.114
  121. Verma S, Arya P, Singh A, Kaswan J, Shukla A, Kushwaha HR, Gupta S, Singh SP. ZnO-rGO nanocomposite based bioelectrode for sensitive and ultrafast detection of dopamine in human serum. Biosens Bioelectron. 2020;165:112347. · DOI
  122. Sanati A, Jalali M, Raeissi K, Karimzadeh F, Kharaziha M, Mahshid SS, Mahshid S. A review on recent advancements in electrochemical biosensing using carbonaceous nanomaterials. Mikrochim Acta. 2019;186(12):773. · DOI
  123. Mei Q, Fu R, Ding Y, Li Li, Wang A, Duan D, Ye D. Electrospinning of highly dispersed Ni/CoO carbon nanofiber and its application in glucose electrochemical sensor. J Electroanal Chem. 2019;847:1175. · DOI
  124. Yones HA, Zhu L, Shao B, Zhang S, Xie H, Li X, Sun W. Magnesium oxide/carbon nanofiber nanocomposite modified electrode for electrochemical hemoglobin sensor. Int J Electrochem Sci. 2021;16:210225. · doi:10.20964/2021.02.37
  125. Corrie SR, Coffey JW, Islam J, Markey KA, Kendall MA. Blood, sweat, and tears: developing clinically relevant protein biosensors for integrated body fluid analysis. Analyst. 2015;140(13):4350–64. · DOI · Paper page
  126. Bruen D, Delaney C, Florea L, Diamond D. Glucose Sensing for Diabetes Monitoring: Recent Developments. Sensors. 2017;17(8):1866. · DOI · Paper page
  127. Lee H, Song C, Hong YS, Kim MS, Cho HR, Kang T, Shin K, Choi SH, Hyeon T, Kim DH. Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module. Sci Adv. 2017; 3(3):e1601314. · DOI · Paper page
  128. Arakawa T, Kuroki Y, Nitta H, Chouhan P, Toma K, Sawada S, Takeuchi S, Sekita T, Akiyoshi K, Minakuchi S, Mitsubayashi K. Mouthguard biosensor with telemetry system for monitoring of saliva glucose: A novel cavitas sensor. Biosens Bioelectron. 2016;84:106–11. · DOI · Paper page
  129. Goud KY, Moonla C, Mishra RK, Yu C, Narayan R, Litvan I, Wang J. Wearable Electrochemical Microneedle Sensor for Continuous Monitoring of Levodopa: Toward Parkinson Management. ACS Sens. 2019;4(8):2196–204. · DOI · Paper page
  130. Bandodkar AJ, Gutruf P, Choi J, Lee K, Sekine Y, Reeder JT, Jeang WJ, Aranyosi AJ, Lee SP, Model JB, Ghaffari R, Su CJ, Leshock JP, Ray T, Verrillo A, Thomas K, Krishnamurthi V, Han S, Kim J, Krishnan S, Hang T, Rogers JA. Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat. Sci Adv. 2019;5(1): eaav3294. · DOI · Paper page
  131. Bian S, Zhu B, Rong G, Sawan M. Towards wearable and implantable continuous drug monitoring: A review. J Pharm Anal. 2021;11(1):1–14. · DOI
  132. Wang L, Xie S, Wang Z, Liu F, Yang Y, Tang C, Wu X, Liu P, Li Y, Saiyin H, Zheng S, Sun X, Xu F, Yu H, Peng H. Functionalized helical fibre bundles of carbon nanotubes as electrochemical sensors for long-term in vivo monitoring of multiple disease biomarkers. Nat Biomed Eng. 2020;4(2):159–71. · DOI · Paper page
  133. Liu C, Zhao Y, Cai X, Xie Y, Wang T, Cheng D, Li L, Li R, Deng Y, Ding H, Lv G, Zhao G, Liu L, Zou G, Feng M, Sun Q, Yin L, Sheng X. A Wireless, Implantable Optoelectrochemical Probe for Optogenetic Stimulation and Dopamine Detection. Microsyst Nanoeng. 2020;6:64. · DOI

Cited by

Metadata

Authors
Kim, J. H., Suh, Y. J., Park, D., Yim, H., Kim, H., Kim, H. J., Yoon, D. S., & Hwang, K. S.
Venue
Biomedical Engineering Letters
Published
2021-08-27
Volume
11
Issue
4
Pages
309-334
ISSN
  • 2093-9868
  • 2093-985X
Cited by
143
References
12
Language
en
Licence
Funders
  • National Research Foundation of Korea (2021R1A2C2004760, NRF-2020R1C1C1008641)
  • Korea Health Industry Development Institute (HU21C0053)

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Technological advances in electrochemical biosensors for the detection of disease biomarkers. https://app.cochat.ai/papers/10.1007/s13534-021-00204-w
The paper
Kim, J. H., Suh, Y. J., Park, D., Yim, H., Kim, H., Kim, H. J., Yoon, D. S., & Hwang, K. S. (2021). Technological advances in electrochemical biosensors for the detection of disease biomarkers. Biomedical Engineering Letters. https://doi.org/10.1007/s13534-021-00204-w

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.