The DOI matches its Crossref record; 71 of the 71 references it cites were found in a registry or an index.
Novel Methods for Pulse Wave Velocity Measurement
Open accessAbstract
The great incidence of cardiovascular (CV) diseases in the world spurs the search for new solutions to enable an early detection of pathological processes and provides more precise diagnosis based in multi-parameters assessment. The pulse wave velocity (PWV) is considered one of the most important clinical parameters for evaluate the CV risk, vascular adaptation, and therapeutic efficacy. Several studies were dedicated to find the relationship between PWV measurement and pathological status in different diseases, and proved the relevance of this parameter. The commercial devices dedicate to PWV estimation make a regional assessment (measured between two vessels), however a local measurement is more precise evaluation of artery condition, taking into account the differences in the structure of arteries. Moreover, the current devices present some limitations due to the contact nature. Emerging trends in CV monitoring are moving away from more invasive technologies to non-invasive and non-contact solutions. The great challenge is to explore the new instrumental solutions that allow the PWV assessment with fewer approximations for an accurately evaluation and relatively inexpensive techniques in order to be used in the clinical routine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2013) · European Heart Journal · doi:10.1093/eurheartj/eht151 · Cited by 13,655
Zhang, Q., Wang, C., Zheng, M., Li, Y., Li, J., Zhang, L., Shang, X., & Yan, C. (2015) · Cerebrovascular Diseases · doi:10.1159/000369778 · Cited by 11,533
Projections of Global Mortality and Burden of Disease from 2002 to 2030
Mathers, C. D., & Loncar, D. (2006) · PLoS Medicine · doi:10.1371/journal.pmed.0030442 · Cited by 11,386
Global status report on noncommunicable diseases 2010.
Alwan, A. (2011) · Cited by 8,494
European Guidelines on cardiovascular disease prevention in clinical practice (version 2012)
Authors/Task Force Members:, Perk, J., De Backer, G., Gohlke, H., Graham, I., Reiner, Ž., Verschuren, M., Albus, C., Benlian, P., Boysen, G., et al. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehs092 · Cited by 8,490
Expert consensus document on arterial stiffness: methodological issues and clinical applications
Laurent, S., Cockcroft, J., Van Bortel, L., Boutouyrie, P., Giannattasio, C., Hayoz, D., Pannier, B., Vlachopoulos, C., Wilkinson, I., Struijker-Boudier, H., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl254 · Cited by 6,077
Laurent, S., Boutouyrie, P., Asmar, R., Gautier, I., Laloux, B., Guize, L., Ducimetiere, P., & Benetos, A. (2001) · Hypertension · doi:10.1161/01.hyp.37.5.1236 · Cited by 3,856
Authors/Task Force Members, Graham, I., Atar, D., Borch-Johnsen, K., Boysen, G., Burell, G., Cifkova, R., Dallongeville, J., De Backer, G., Ebrahim, S., et al. (2007) · European Heart Journal · doi:10.1093/eurheartj/ehm316 · Cited by 3,753
McDonald's blood flow in arteries; theoretical, experimental and clinical principles
(1992) · General Pharmacology: The Vascular System · doi:10.1016/0306-3623(92)90079-y · Cited by 2,388
The Reference Values for Arterial Stiffness' Collaboration (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq165 · Cited by 2,087
Boutouyrie, P., Tropeano, A. I., Asmar, R., Gautier, I., Benetos, A., Lacolley, P., & Laurent, S. (2002) · Hypertension · doi:10.1161/hy0102.099031 · Cited by 1,745
Willum Hansen, T., Staessen, J. A., Torp-Pedersen, C., Rasmussen, S., Thijs, L., Ibsen, H., & Jeppesen, J. (2006) · Circulation · doi:10.1161/circulationaha.105.579342 · Cited by 1,515 · cited 2×
“[41]”
BackgroundAortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493 · cited 1×
“population, that showed the correlation of PWV with atherosclerosis alterations and constitutes a predictor of CV risk in hypertensive patients [36].”
BackgroundAsmar, R., Benetos, A., Topouchian, J., Laurent, P., Pannier, B., Brisac, A.-M., Target, R., & Levy, B. I. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.485 · Cited by 1,376
Clinical applications of arterial stiffness; definitions and reference values
O'Rourke, M. F., Staessen, J. A., Vlachopoulos, C., Duprez, D., & Plante, G. E. E. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(01)02319-6 · Cited by 1,100
Global status report on noncommunicable diseases
Chan, M. (2010) · Cited by 1,065
Aortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
Toward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935 · cited 1×
“However, major progress on the algorithms to determine the BP using the PWV measurement is still required, like the calibration of pulse transit time (PTT, in units of ms) to BP (in units of mmHg) [21].”
BackgroundAortic Pulse Wave Velocity Predicts Cardiovascular Mortality in Subjects >70 Years of Age
Meaume, S., Benetos, A., Henry, O. F., Rudnichi, A., & Safar, M. E. (2001) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/hq1201.100226 · Cited by 734
European Guidelines on cardiovascular disease prevention in clinical practice (version 2012)
Perk, J., De Backer, G., Gohlke, H., Graham, I., Reiner, Ž., Verschuren, W. M. M., Albus, C., Benlian, P., Boysen, G., Cifkova, R., et al. (2012) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2012.05.007 · Cited by 691
Gesche, H., Grosskurth, D., Küchler, G., & Patzak, A. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-011-1983-3 · Cited by 470
Latham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454
Horváth, I. G., Németh, Á., Lenkey, Z., Alessandri, N., Tufano, F., Kis, P., Gaszner, B., & Cziráki, A. (2010) · Journal of Hypertension · doi:10.1097/hjh.0b013e32833c8a1a · Cited by 374
McDonald's Blood Flow in Arteries : Theoretic, Experimental and Clinical Principles
Nicholas, W. W., O’Rourke, M. F., & McDonald, D. A. (1990) · Medical Entomology and Zoology · Cited by 354
Baulmann, J., Schillings, U., Rickert, S., Uen, S., Düsing, R., Illyes, M., Cziraki, A., Nickenig, G., & Mengden, T. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e3282f314f7 · Cited by 319
Rajzer, M. W., Wojciechowska, W., Klocek, M., Palka, I., Brzozowska-Kiszka, M., & Kawecka-Jaszcz, K. (2008) · Journal of Hypertension · doi:10.1097/hjh.0b013e32830a4a25 · Cited by 308
Salvi, P., Lio, G., Labat, C., Ricci, E., Pannier, B., & Benetos, A. (2004) · Journal of Hypertension · doi:10.1097/00004872-200412000-00010 · Cited by 295
Assessing the Role of Circulating, Genetic, and Imaging Biomarkers in Cardiovascular Risk Prediction
Wang, T. J. (2011) · Circulation · doi:10.1161/circulationaha.109.912568 · Cited by 294
Isnard, R. N., Pannier, B. M., Laurent, S., London, G. M., Diebold, B., & Safar, M. E. (1989) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(89)90518-4 · Cited by 235
Vascular Stiffness and Increased Pulse Pressure in the Aging Cardiovascular System
Steppan, J., Barodka, V., Berkowitz, D. E., & Nyhan, D. (2011) · Cardiology Research and Practice · doi:10.4061/2011/263585 · Cited by 231
An ultrasound-based method for determining pulse wave velocity in superficial arteries
Rabben, S. I., Stergiopulos, N., Hellevik, L. R., Smiseth, O. A., Slørdahl, S. A., Urheim, S., & Angelsen, B. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.12.031 · Cited by 176
The Pulse Wave Velocity as an Early Indicator of Atherosclerosis in Diabetic Subjects
WOOLAM, G. L., SCHNUR, P. L., VALLBONA, C., & HOFF, H. E. (1962) · Circulation · doi:10.1161/01.cir.25.3.533 · Cited by 171
Arterial Stiffness and Cardiovascular Therapy
Janić, M., Lunder, M., & Šabović, M. (2014) · BioMed Research International · doi:10.1155/2014/621437 · Cited by 168
Cattivelli, F. S., & Garudadri, H. (2009) · 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn.2009.35 · Cited by 166
Assessment of pulse wave velocity
Boutouyrie, P., Briet, M. B., Collin, C., Vermeersch, S. J., & Pannier, B. (2008) · Artery Research · doi:10.1016/j.artres.2008.11.002 · Cited by 165
Plasma Homocysteine, Aortic Stiffness, and Renal Function in Hypertensive Patients
Bortolotto, L. A., Safar, M. E., Billaud, E. M., Lacroix, C., Asmar, R. G., London, G. M., & Blacher, J. (1999) · Hypertension · doi:10.1161/01.hyp.34.4.837 · Cited by 165
The Framingham Heart Study's Impact on Global Risk Assessment
Bitton, A., & Gaziano, T. (2010) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2010.04.001 · Cited by 158
Ong, M. E. H., Ng, C. H. L., Goh, K. J., Liu, N., Koh, Z. X., Shahidah, N., Zhang, T. T., Fook-Chong, S. M. C., & Lin, Z. (2012) · Critical Care · doi:10.1186/cc11396 · Cited by 156
Doppler ultrasound in the measurement of pulse wave velocity: agreement with the Complior method
Martínez, J. C., Torguet, P., García-Gil, M., Garcia, I., Martín, N., Guasch, B., Faur, D., & Vallés, M. (2011) · Cardiovascular Ultrasound · doi:10.1186/1476-7120-9-13 · Cited by 147
Aortic Distensibility in Normotensive, Untreated and Treated Hypertensive Patients
Asmar, R. G., Bénétos, A., London, G. M., Hugue, C., Weiss, Y. A., Topouchian, J. A., Laloux, B., & Safar, M. E. (1995) · Blood Pressure · doi:10.3109/08037059509077567 · Cited by 140
Ibrahim, E. H., Johnson, K. R., Miller, A. B., Shaffer, J. M., & White, R. D. (2010) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/1532-429x-12-26 · Cited by 110
Segers, P., Kips, J. G., Trachet, B., Swillens, A., Vermeersch, S. J., Mahieu, D., Rietzschel, E. R., Buyzere, M. D., & Bortel, L. M. V. (2009) · Artery Research · doi:10.1016/j.artres.2009.02.006 · Cited by 109
Joly, L., Perret‐Guillaume, C., Kearney‐Schwartz, A., Salvi, P., Mandry, D., Marie, P., Karcher, G., Rossignol, P., Zannad, F. M., & Bénétos, A. (2009) · Hypertension · doi:10.1161/hypertensionaha.109.133645 · Cited by 109
Non-contact cardiac monitoring from carotid artery using optical vibrocardiography
Scalise, L., & Morbiducci, U. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.008 · Cited by 95
O’Rourke, M. F., & Seward, J. B. (2006) · Mayo Clinic Proceedings · doi:10.4065/81.8.1057 · Cited by 90
van der Meer, R. W., Diamant, M., Westenberg, J. J. M., Doornbos, J., Bax, J. J., Roos, A., & Lamb, H. J. (2007) · Journal of Cardiovascular Magnetic Resonance · doi:10.1080/10976640601093703 · Cited by 89
Clinical Assessment of Central Blood Pressure
Miyashita, H. (2012) · Current Hypertension Reviews · doi:10.2174/157340212800840708 · Cited by 86
Assessment of Cardiovascular Disease Risk in South Asian Populations
Hussain, S. M., Oldenburg, B. F., Wang, Y., Zoungas, S., & Tonkin, A. M. (2013) · International Journal of Vascular Medicine · doi:10.1155/2013/786801 · Cited by 79
Maldonado, J. M. P., Pereira, T. S., Polónia, J. J., Silva, J. A., Morais, J., & Marques, M. C. (2011) · Journal of Hypertension · doi:10.1097/hjh.0b013e3283432063 · Cited by 78
Self-citationArterial stiffness and novel biomarkers in patients with abdominal aortic aneurysms
Kadoglou, N. P. E., Papadakis, I., Moulakakis, K. G., Ikonomidis, I., Alepaki, M., Moustardas, P., Lampropoulos, S., Karakitsos, P., Lekakis, J. P., & Liapis, C. D. (2012) · Regulatory Peptides · doi:10.1016/j.regpep.2012.08.014 · Cited by 76
Continuous blood pressure monitoring during exercise using pulse wave transit time measurement
Lass, J., Meigas, I. C., Karai, D., Kattai, R., Kaik, J., & Rossmann, M. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1403652 · Cited by 73
Blood pressure estimation from pulse wave velocity measured on the chest
Puke, S., Suzuki, T., Kanako, N., Tanaka, H., & Minami, S. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6610946 · Cited by 63
Metabolomic study of carotid–femoral pulse-wave velocity in women
Menni, C., Mangino, M., Cecelja, M., Psatha, M., Brosnan, M. J., Trimmer, J. K., Mohney, R. P., Chowienczyk, P., Padmanabhan, S., Spector, T. D., et al. (2014) · Journal of Hypertension · doi:10.1097/hjh.0000000000000467 · Cited by 63
A Blood Pressure Monitoring Method for Stroke Management
Ma, H. T. (2014) · BioMed Research International · doi:10.1155/2014/571623 · Cited by 58
A Noncontact Approach for the Evaluation of Large Artery Stiffness: A Preliminary Study
Melis, M. D., Morbiducci, U., Scalise, L., Tomasini, E. P., Delbeke, D., Baets, R., Bortel, L. M. V., & Segers, P. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.280 · Cited by 55
Aortic Pulse Wave Velocity and Carotid-Femoral Pulse Wave Velocity: Similarities and Discrepancies
Podolec, P. S., Kopeć, G., Podolec, J., WILKOLEK, P., Krochin, M., Rubiś, P., Cwynar, M., Grodzicki, T. K., Zmudka, K. F., & TRACZ, W. (2007) · Hypertension Research · doi:10.1291/hypres.30.1151 · Cited by 53
On-chip laser Doppler vibrometer for arterial pulse wave velocity measurement
Li, Y., Segers, P., Dirckx, J., & Baets, R. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001229 · Cited by 49
Arza, A., Lázaro, J. M., Gil, E., Laguna, P., Aguiló, J., & Bailón, R. (2013) · Computing in cardiology · Cited by 47
Christodoulides, N. J., Floriano, P. N., Sanchez, X., Li, L., Hocquard, K., Patton, A. M., Muldoon, R., Miller, C. S., Ebersole, J. L., Redding, S. W., et al. (2012) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-8-1-6 · Cited by 45
Vappou, J., Luo, J., Okajima, K., Tullio, M. R. D., & Konofagou, E. E. (2011) · Artery Research · doi:10.1016/j.artres.2011.03.002 · Cited by 44
Arterial Stiffness: A Simplified Overview in Vascular Medicine
Safar, M. E. (2006) · KARGER eBooks · doi:10.1159/000096699 · Cited by 40
Pulse wave velocity in the carotid artery
Sørensen, G. L., Jensen, J. B., Udesen, J., Holfort, I. K., & Jensen, J. A. (2008) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.2008.0336 · Cited by 39
Continuous blood pressure monitoring using pulse wave delay
Meigas, K., Kattai, R., & Lass, J. (2005) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2001.1019495 · Cited by 38
Non-invasive technique for assessment of vascular wall stiffness using laser Doppler vibrometry
Campo, A., Segers, P., Heuten, H., Goovaerts, I., Ennekens, G., Vrints, C. J., Baets, R., & Dirckx, J. (2014) · Measurement Science and Technology · doi:10.1088/0957-0233/25/6/065701 · Cited by 18
Pulse Wave Velocity in Continuous Blood Pressure Measurements
Meigas, K., Lass, J., Karai, D., Kattai, R., & Kaik, J. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_144 · Cited by 16
Characterization of Optical System for Hemodynamic Multi-Parameter Assessment
Pereira, T., Santos, I., de Oliveira, T., Vaz, P. G., Correia, T., Pereira, T., Santos, H., Pereira, H., Almeida, V., Cardoso, J., et al. (2013) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-013-0125-y · Cited by 14
Self-citationLocal Pulse Wave Velocity Estimation in the Carotids Using Dynamic MR Sequences
Darwich, M. A., Langevin, F., & Darwich, K. M. A. (2015) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2015.84022 · Cited by 14
Pulse pressure waveform estimation using distension profiling with contactless optical probe
Pereira, T., Santos, I. P., Oliveira, T., Vaz, P. G., Pereira, T. S., Santos, H., Pereira, H. C., Correia, C. M. B. A., & Cardoso, J. M. R. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.07.014 · Cited by 11
Self-citationEmpirical mode decomposition for self-mixing Doppler signals of hemodynamic optical probes
Pereira, T., Vaz, P. G., Oliveira, T., Santos, I. P., Pereira, H. C., Almeida, V., Correia, C. M. B. A., & Cardoso, J. M. R. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/3/377 · Cited by 7
Self-citationComparison of Low-Cost and Noninvasive Optical Sensors for Cardiovascular Monitoring
Pereira, T., Oliveira, T., Cabeleira, M. T., Pereira, H. C., Almeida, V., Cardoso, J. M. R., & Correia, C. M. B. A. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2236549 · Cited by 6
Self-citationCorrelation study between blood pressure and pulse transit time
Pereira, T., Sanches, R., Reis, P., Pêgo, J. M., & Simões, R. (2015) · IEEE Portuguese Meeting on Bioengineering · doi:10.1109/enbeng.2015.7088864 · Cited by 5
Self-citation
Cited by
Photoplethysmography based atrial fibrillation detection: a review
Pereira, T., Tran, N., Gadhoumi, K., Pelter, M. M., Do, D. H., Lee, R. J., Colorado, R., Meisel, K., & Hu, X. (2020) · npj Digital Medicine · doi:10.1038/s41746-019-0207-9 · Cited by 300
Self-citationThin, soft, wearable system for continuous wireless monitoring of artery blood pressure
Li, J., Jia, H., Zhou, J., Huang, X., Xu, L., Jia, S., Gao, Z., Yao, K., Li, D., Zhang, B., et al. (2023) · Nature Communications · doi:10.1038/s41467-023-40763-3 · Cited by 293
Cuffless Blood Pressure Monitoring: Promises and Challenges
Pandit, J. A., Lores, E., & Batlle, D. (2020) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03680320 · Cited by 101
Nabeel, P. M., Karthik, S., Joseph, J., & Sivaprakasam, M. (2018) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2800539 · Cited by 72
Experimental validation of dual PPG local pulse wave velocity probe
Nabeel, P. M., Karthik, S., Joseph, J., & Sivaprakasam, M. (2017) · 2017 IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea.2017.7985911 · Cited by 20
“Working principle and design form factor of the existing PWV measurement devices limit their use in local PWV assessment [8].”
Background
Metadata
- Authors
- Pereira, T., Correia, C., & Cardoso, J.
- Venue
- Journal of Medical and Biological Engineering
- Published
- 2015-10
- Volume
- 35
- Issue
- 5
- Pages
- 555-565
- ISSN
- 1609-0985 (ISSN-L)
- 2199-4757
- OpenAlex
- W2190147660
- Cited by
- 284
- References
- 71
- FWCI
- 14.28
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.