Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 901–1,000 of 1,000
Komine, F., Kamio, S., TAKATA, H., Yagawa, S., Taguchi, S., Taguchi, K., Hashiguchi, A., & Matsumura, H. (2017) · Dental Materials Journal · doi:10.4012/dmj.2017-057 · Cited by 5
Estimation of Object Elasticity by Capturing Fingernail Images During Haptic Palpation
Yoshimoto, S., Kuroda, Y., & Oshiro, O. (2018) · IEEE Transactions on Haptics · doi:10.1109/toh.2018.2803053 · Cited by 5
“, designing structures [1], selecting materials [2], evaluating tissues [3], and testing organ properties [4].”
BackgroundFundamental mechanisms of laser shock processing of metals and ceramics
Cui, B., Wang, F., Yan, X., Zhang, C., Deng, L., Lu, Y., & Nastasi, M. (2018) · doi:10.1117/12.2501281 · Cited by 5
“The shock wave pressure in this experiment was calculated to be around 5 GPa, which is lower than the Hugoniot elastic limit of α-Al2O3 (6.7 GPa).”
BackgroundInfluentialNikolsky, A. (2020) · Springer eBooks · doi:10.1007/978-981-15-4250-3_8 · Cited by 5
Other metallic alloys: tantalum-based materials for biomedical applications
Rodríguez‐Contreras, A., Moruno, C. M., Fernández-Fairén, M., Rupérez, E., Gil, F. J., & Manero, J. M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-818831-6.00007-0 · Cited by 5
Kamal, D., Jain, P., Biswas, J. K., & Chua, S. N. D. (2023) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062231156101 · Cited by 5
“7 14 Researchers are also trying to propose various designs, materials like polyetheretherketone (PEEK) for spinal application 15–17 to provide stability to the spinal section.”
BackgroundAlbumin removal from human fibrinogen preparations for manufacturing human fibrin-based biomaterials
Sharma, V., Patel, N., Dye, J. F., Hook, L., Mason, C., & García‐Gareta, E. (2015) · Biochimie Open · doi:10.1016/j.biopen.2015.05.002 · Cited by 5
Dahl, A. C. E., & Thompson, M. S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-088504-9.00419-0 · Cited by 6
Finite element analysis on internal hexagonal and internal conical abutment
Saidin, S., Kadir, M. R. A., Sulaiman, E., & Kassim, N. A. (2010) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes.2010.5742231 · Cited by 5
Ren, J., Du, X., Liu, T., Liu, H., Hua, M., & Liu, Q. (2017) · SAE technical papers on CD-ROM/SAE technical paper series · doi:10.4271/2017-01-0406 · Cited by 5
Yue, Y., Yang, H., Li, Y., Zhong, H., Tang, Q., Wang, J., Wang, R., He, H., Chen, W., & Chen, D. (2019) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2019.02.002 · Cited by 5
Can Syndesmosis Screws Displace the Distal Fibula?
Vance, N. G., Vance, R. C., Chandler, W. T., & Panchbhavi, V. K. (2020) · Foot & Ankle Specialist · doi:10.1177/1938640020912092 · Cited by 5
“Solid elements were given isotropic material properties as shown in Table 1.(10)”
BackgroundMethodEstudio de biocompatibilidad y osteointegración de nuevos materiales protésicos
Giner, M., Santana, L., Costa, A. F., Vázquez, M. Á., Colmenero, M. Á., Olmo, F. J., Chicardi, E., Torres, Y., & Montoya-García, M. (2020) · Revista de Osteoporosis y Metabolismo Mineral · doi:10.4321/s1889-836x2020000300004 · Cited by 5
Review on the Biocompatibility and Bioactivity of Forsterite: In Vitro and in Vivo studies
Avram, A., Mocanu, A., Tomoaia, G., & Tomoaia-Cotişel, M. (2022) · Annals of the Academy of Romanian Scientists Series on Biological Sciences · doi:10.56082/annalsarscibio.2022.1.167 · Cited by 5
Contact mechanics and wear simulations of hip resurfacing devices using computational methods
Ali, M., & Mao, K. (2014) · PubMed · doi:10.5277/abb140212 · Cited by 5
Microscopic Approach for Testing Mechanical Properties of Hard Tissues
Marrese, M., Guarino, V., & Ambrosio, L. (2015) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.02260-8 · Cited by 5
Mechanical Properties of Bioresorbable Self-reinforced Posterior Cervical Rods
Savage, K. E., Sardar, Z. M., Pohjonen, T., Sidhu, G. S., Eachus, B. D., & Vaccaro, A. R. (2013) · Journal of Spinal Disorders & Techniques · doi:10.1097/bsd.0b013e318299c6d8 · Cited by 5
Gefen, A., & Neulander, R. (2007) · Journal of Applied Biomechanics · doi:10.1123/jab.23.3.230 · Cited by 5
Laser welding of shape memory alloys for medical applications
Pfeifer, R., Herzog, D., Meier, O. C., Ostendorf, A., Haferkamp, H., Goesling, T., Hurschler, C., & Müller, C. W. (2008) · International Congress on Applications of Lasers & Electro-Optics (ICALEO) · doi:10.2351/1.5061388 · Cited by 5
A finite element modelling strategy for suture anchor devices
Hughes, C. C. W. (2014) · Brunel University Research Archive (BURA) (Brunel University London) · Cited by 5
Watanabe, A., Sakurai, T., Kumasaka, S., & Kashima, I. (2004) · Oral Radiology · doi:10.1007/s11282-004-0007-y · Cited by 5
“The physical properties of bone trabeculae are examined using a micromaterial examination apparatus.(5) One study showed that the mechanical strength of bone trabeculae in osteoporosis is not always correlated with BMD.”
MethodGuo, X. E., Hu, Y., & Dinescu, A. T. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.11551-x · Cited by 5
Influence de l’hétérogénéité des propriétés mécaniques sur la résistance de l’os trabéculaire humain
Dépalle, B. (2011) · theses.fr (ABES) · doi:10.70675/bf4d472cz0dd4z4d20za7f2zd8806f663dd6 · Cited by 5
“Des valeurs similaires mais légèrement inférieures ont été mesurées pour de l’os trabéculaire humain [343, 405, 360].”
InfluentialBry, R. (2015) · theses.fr (ABES) · doi:10.70675/17b6d644z80f0z4beeza32ezafb68fe06909 · Cited by 5
Li, H., Hai, J., Shan, C., Xu, Q., Xu, Z., Lei, Y., & Jing, L. (2025) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-025-2822-8 · Cited by 4
“Rho et al. [21] suggested that the elastic modulus of human cancellous bone ranges from 6.9 to 14.8GPa, the value of permeability of human cancellous bone is 5 .”
InfluentialLy, A., Tan, Q., Li, Y., Xin, Z., Wang, F., Erbulut, D. U., Xu, C., & Zhang, M. (2025) · Materials & Design · doi:10.1016/j.matdes.2025.114429 · Cited by 4
Suitability of Mg-Nd and Mg-Zn Alloys to Obtain Biodegradable Structures for Bone Defects
Mănescu, V., Antoniac, A., Moraru, M.-C., Antoniac, I., Cotruț, C. M., Grădinaru, S., Dreancă, A., Sevastre, B., Pop, R., Tăbăran, F., et al. (2025) · Journal of Functional Biomaterials · doi:10.3390/jfb16110423 · Cited by 4
What enhancement could β-titanium bring to oral implantology?
Montet, C., Abouelleil, H., Labadi, C., Gauthier, R., Lafon, A., & Attik, N. (2025) · Dental Materials · doi:10.1016/j.dental.2025.11.005 · Cited by 4
Ganji, F., Mirzagoli, M., & Tayebi, L. (2026) · ADMET & DMPK · doi:10.5599/admet.3037 · Cited by 4
“13.0 ± 1.47 [12] Young's modulus (GPa) 10.4 ± 3.5 [13] Tensile yield stress (MPa) 0.78 ± 0.04 [14] Compressive yield strain (MPa) 0.84 ± 0.06 Poisson's ratio 0.3 [15] Storage modulus (GPa) 13.75 ± 3.21 [16] Loss modulus (GPa) 6.39 ± 1.28 [16] Extensive bone loss due to trauma, tumours, or genetic…”
Influentialdos Santos, R. B., Lenz, U., Griggs, J. A., & Bona, Á. D. (2026) · Journal of Dentistry · doi:10.1016/j.jdent.2026.106510 · Cited by 4
Hasson, F., Rodzeń, K., Ward, J., McIlhagger, A., O’Donnell, E., & Boyd, A. (2026) · Macromolecular Materials and Engineering · doi:10.1002/mame.202500436 · Cited by 4
Cavelier, S., & Hutmacher, D. W. (2026) · Cell Biomaterials · doi:10.1016/j.celbio.2026.100457 · Cited by 4
Adamović, P., Kodvanj, J., Blažević, D., & Sabalić, S. (2023) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-023-02771-9 · Cited by 4
“The elastic modulus of cancellous bone was set to 1100 MPa and the elastic modulus of cortical bone was set to 17,000 MPa [20, 21].”
BackgroundInfluentialShrivas, N. V., Badhyal, S., Tiwari, A. K., Mishra, A., Tripathi, D., & Patil, S. S. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107592 · Cited by 4
Biomechanical research using advanced micro-nano devices: In-Vitro cell Characterization focus
Yan, S., Lu, Y., An, C., Hu, W., Chen, Y., Li, Z., Wei, W., Chen, Z., Zeng, X., Xu, W., et al. (2024) · Journal of Advanced Research · doi:10.1016/j.jare.2024.12.024 · Cited by 5
Seifi, E., Mohseni, M., Samson, K. D. G., Cavelier, S., Ayyachi, T., & Hutmacher, D. W. (2025) · Journal of the American Ceramic Society · doi:10.1111/jace.70069 · Cited by 4
Öztürk, V., Kaya, B., Çelik, T., Çelik, M., Kural, C., & Bilgili, M. G. (2025) · International Orthopaedics · doi:10.1007/s00264-025-06604-2 · Cited by 4
Process-Driven Optimization of FDM Porous PEEK Scaffolds for Alloplastic Bone Grafts
Mifsud, M. G., Silvio, L. D., & Coward, T. J. (2025) · ACS Omega · doi:10.1021/acsomega.5c06631 · Cited by 4
NON-LINEAR 3D FINITE ELEMENT ANALYSIS OF THE FEMUR BONE
., S. V. (2013) · International Journal of Research in Engineering and Technology · doi:10.15623/ijret.2013.0203008 · Cited by 4
Jiang, X., Yao, Y., Tang, W., Han, D., Zhang, L., Zhao, K., Wang, S., & Meng, Y. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01254 · Cited by 4
Determining Young's Modulus of Elasticity of Cortical Bone from CT Scans
Vulović, A., & Filipović, N. (2021) · Wiley eBooks · doi:10.1002/9781119563983.ch4 · Cited by 4
Dahl, A. C. E., & Thompson, M. S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-444-64046-8.00285-8 · Cited by 4
Tavakoli, A., Spangenberg, G. W., Reeves, J. M., Faber, K. J., & Langohr, G. D. G. (2023) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2023.04.006 · Cited by 4
Medical Applications of Additive Manufacturing
Judkins, L., Manogharan, G. P., Gupta, R., Jia, L., Tang, M. M., Teinturier, T. D., & Hast, M. W. (2023) · ASM International eBooks · doi:10.31399/asm.hb.v24a.a0006966 · Cited by 4
Effect of morphology and cortical thickness variations on tibial strains in different movements
Long, T., Besier, T. F., Fernandez, J., & Yeung, T. (2024) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2024.112486 · Cited by 4
Non-invasive Bone Quality Assessment Using Quantitative Ultrasound Imaging and Acoustic Parameters
Qin, Y., Lin, W., Xia, Y., Mittra, E., Rubin, C., & Müller, R. (2007) · Springer eBooks · doi:10.1007/978-3-540-45456-4_7 · Cited by 4
ANÁLISIS LINEAL Y NO LINEAL DE LOS ESFUERZOS EN PILARES DE CIRCONIO PREFORMADOS. ELEMENTOS FINITOS
Valencia, F. M. R., Restrepo, J. C. E., Correa, F. L., & Ossa, J. A. V. (2014) · Dialnet (Universidad de la Rioja) · doi:10.24050/19099762.n16.2014.651 · Cited by 4
Non-Destructive Mechanical Testing of Allograft Bone-Implants by Analytic Centrifugation
Bäumler, H., Hamberger, L., Zaslansky, P., Kalus, U. J., Georgieva, R. T., & Prüß, A. (2016) · Experimental Mechanics · doi:10.1007/s11340-016-0201-y · Cited by 4
Jahadakbar, A. (2016) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 4
Devitrification and hydrogen storage capacity of the eutectic Ca72Mg28 metallic glass
Saksl, K., Ďurišin, J., Balga, D., Milkovič, O., Brestovič, T., Jasminská, N., Ďurišin, M., Girman, V., Balko, J., Katuna, Y., et al. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.07.226 · Cited by 4
Yamada, S., Fukasawa, K., Suzuki, Y., Takahashi, Y., Todoh, M., & TADANO, S. (2022) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2022.103823 · Cited by 4
Hu, X., Lu, M., Wang, Y., Wen, Y., Tan, L., Du, G., Zhou, Y., Luo, Y., Min, L., & Tu, C. (2022) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-022-05801-z · Cited by 4
Natural composites: structure–property relationships in bone, cartilage, ligament and tendons
Purbrick, M. D., Ambrosio, L., Ventre, M., & Netti, P. A. (2010) · Elsevier eBooks · doi:10.1533/9781845697372.1.3 · Cited by 4
Towards real time machine learning based estimation of fracture risk in osteoporosis patients
Ciusdel, C. F., Vizitiu, A., Moldoveanu, F. D., Suciu, C., & Itu, L.-M. (2017) · International Aegean Conference on Electrical Machines and Power Electronics & International Conference on Optimization of Electrical and Electronic Equipment (ACEMP-OPTIM) · doi:10.1109/optim.2017.7975126 · Cited by 4
An In-Silico Assessment of Stemless Shoulder Arthroplasty: from CT to Predicted Bone Response
Reeves, J. M. (2018) · Scholarship@Western (Western University) · Cited by 4
Dimensional consistency of SLM printed orthopaedic implants designed using lightweight structures
Yan, L., Zhao, L. P., & O’Neill, G. K. (2020) · Transactions on Additive Manufacturing Meets Medicine · doi:10.18416/ammm.2020.2009017 · Cited by 4
“However, the young’s modulus of SS316L is at around 200 GPa, which is significantly higher than that of the cortical bone, which is 18 - 20 GPa [2].”
BackgroundManagement of Pediatric Orbital Fractures
Wolff, A. Y., Ohayon, C., Emodi, O., Sviri, G. E., Shapira, V., & Rachmiel, A. (2020) · Journal of Craniofacial Surgery · doi:10.1097/scs.0000000000006915 · Cited by 4
“For the elastic pediatric craniofacial bones to fracture, a significant force of impact must be endured.(3) This premise is intimately related to the associated concomitant incidence of neurocranial injuries in pediatric facial fractures.”
BackgroundComposite engineered biomaterial adaptable for repair and regeneration of wounds
Wu, Y., & Wagner, W. D. (2021) · Wound Repair and Regeneration · doi:10.1111/wrr.12891 · Cited by 4
A First-Time Addition of Selenium to a Mg-Based Metal Matrix Composite for Biomedical Purposes
Pahaul, A., Johanes, M., & Gupta, M. K. (2024) · Journal of Composites Science · doi:10.3390/jcs8030081 · Cited by 4
“Considering the Young’s modulus of human cortical bone (ranging from 12.6 to 27 GPa [36–38]) magnesium-based materials such as the current one provide the best option to mitigate stress shielding when compared to steels and titanium and Co-based alloys.”
BackgroundInfluentialBiomaterials: Processing, Characterization, and Applications
Lacroix, D., & Planell, J. A. (2009) · Springer eBooks · doi:10.1007/978-0-387-84872-3_4 · Cited by 4
Problems with ultrasonic measurements of shear modules of structured media
Besdo, D., Besdo, S., Behrens, B., & Bouguecha, A. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2006.09.002 · Cited by 4
Araki, M., Kawashima, S., Matsumoto, N., Nishimura, S., & Komiyama, K. (2008) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/99191766 · Cited by 4
Stress Analysis of All-on-4 System Using a 3-Dimensional Finite Element Method
Sasaki, K., Matsushita, Y., Tsukiyama, Y., Esaki, D., & Koyano, K. (2008) · Prosthodontic Research & Practice · doi:10.2186/prp.7.147 · Cited by 4
Optimization of WSU Total Ankle Replacement Systems
Elliott, B. J. (2012) · CORE Scholar (Wright State University) · Cited by 4
Hortensius, R. A., Lin, W., & Ogle, B. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-813068-1.00001-4 · Cited by 4
Conductive Hydrogels for Bioelectronic Interfaces
Akbar, T. F., Tondera, C., & Minev, I. R. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_9 · Cited by 4
Comprehensive Analysis of Joints from Patient Clinical Data
Bajaj, C., Bernardini, F., Cutchin, S., Lin, K.-N., & Sacks, E. P. (1997) · Purdue e-Pubs (Purdue University System) · Cited by 4
Composite Scaffolds for Bone Tissue Regeneration
Navarro, M., & Planell, J. A. (2012) · Wiley eBooks · doi:10.1002/9781118097298.weoc050 · Cited by 4
Micro-computed tomography studies of biomaterials and bone
Jones, A. C. (2008) · ANU Open Research (Australian National University) · doi:10.25911/5d78dcf139dfd · Cited by 4
“Other methods such as buckling [208, 239] and micro-tensile testing [6, 198] have also been used to estimate Young’s modulus.”
BackgroundMethodVlaisavljevich, E. (2015) · Deep Blue (University of Michigan) · Cited by 4
Adams, G. J. (2017) · CERES (Cranfield University) · Cited by 4
Stipsitz, M. (2020) · reposiTUm (TU Wien) · doi:10.34726/hss.2020.36055 · Cited by 4
Swelling and mechanical characterization of a porous swelling co-polymer for orthopedic applications
McDonald, V., & Siegler, S. (2021) · iDEA - Drexel University Institutional Repository · doi:10.17918/00000592 · Cited by 4
Streppa, L. (2017) · theses.fr (ABES) · doi:10.70675/e42d405cz401az4abfz9d64ze4b2b127854d · Cited by 4
Advancing Exoskeleton Development: Validation of a Robotic Surrogate to Measure Tibial Strain
McGrath, R. L., Price, C. A., Johnson, W. B., & Childers, W. L. (2024) · Bioengineering · doi:10.3390/bioengineering11050490 · Cited by 3
Thamarai, C., Hariharan, A., Thanya, K., Baby, A. G., Saishree, A., Parameswari, D., & Narmadha, D. (2025) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/jpbs.jpbs_370_25 · Cited by 3
“[3] A newer technique was used to insert the implants into the model, ensuring complete integration with the resin.”
Fatigue behavior and estimated lifetime of implant/abutments of different diameters
dos Santos, R. B., Lenz, U., Griggs, J. A., & Bona, Á. D. (2025) · Dental Materials · doi:10.1016/j.dental.2025.09.021 · Cited by 3
Syahruddin, M. H., Ana, I. D., Belyaev, D., Irnawati, D., Wihadmadyatami, H., Beshchasna, N., & Anggraeni, R. (2025) · Biomedical Reports · doi:10.3892/br.2025.2079 · Cited by 3
Development and Characteristics of a Dual-Layered Vascular Phantom
Elmer, K. M., Caffin, C., Scott, B., Stephens, S. E., & Jensen, M. Ø. (2025) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-025-00810-0 · Cited by 3
Fereydoonpour, M., Rezaei, A., Lu, L., Ziejewski, M., & Karami, G. (2025) · Annals of Biomedical Engineering · doi:10.1007/s10439-025-03948-z · Cited by 3
“This selection was informed by the mechanical properties of cancellous bone, which typically exhibits an elastic modulus in the range of 50–500 MPa depending on density and anatomical location [29–31].”
Song, L., Wang, X., Pu, Y., Hu, X., He, J., Jin, R., & Nie, Y. (2026) · Collagen and Leather · doi:10.1186/s42825-026-00237-w · Cited by 3
Kebdani, S., Zahaf, S., Mansouri, B., & Aour, B. (2017) · Nano Biomedicine and Engineering · doi:10.5101/nbe.v9i3.p249-274 · Cited by 3
“In relation to implants, stiff metallic screws, with stiffness on the order of 100-200 GPa, carry the majority of the shared load.”
BackgroundGubicza, J., Nagy, K., Hegedues, Z., Tambe, I., Nagy, P., Hektor, J., Han, C., & Choe, H. (2025) · Materials Science and Engineering A · doi:10.1016/j.msea.2025.148673 · Cited by 3
Meyer, L. A., Collins, C. J., Klei, M. V., Correa-Belloso, A., Zojaji, M., & Ploeg, H. (2025) · Journal of Biomechanical Engineering · doi:10.1115/1.4069958 · Cited by 3
Experimental Analysis of Parameters Influencing the Bone Burring Process
Kusins, J. R. (2015) · Scholarship@Western (Western University) · Cited by 3
Preclinical biomechanics of a new intramedullary nail for femoral diaphyseal fractures
Ivanov, D. V., Barabash, A., & Barabash, Y. (2015) · Russian Open Medical Journal · doi:10.15275/rusomj.2015.0205 · Cited by 3
INFLUENCE OF THE BONE MORPHOLOGY ON MECHANICAL BEHAVIOR OF HUMAN SKULL FOR TWO STRAIN RATE CASES
Karkar, M., Maréchal, C., Delille, R., Haugou, G., BRESSON, F., Drazétic, P., & Colard, T. (2018) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s021951941850046x · Cited by 3
Bano, N., Sunil Kumar, M., Shivamurthy, P. G., Sabrish, S., & Mathew, S. (2022) · Journal of Dental Research Dental Clinics Dental Prospects · doi:10.34172/joddd.2022.017 · Cited by 3
Idealization of functionally graded porous tubes for buckling modelling of bone structures
Nokkaew, N., & Eiadtrong, S. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e11580 · Cited by 3
“[27, 30] that can be used for metaphysis, epiphysis and diaphysis, because they are of the same structures.”
BackgroundFinite element analysis of a stemmed hip prosthesis to reduce stress shielding in the proximal femur
Bliss, O., Swadener, J. G., Pierce, G., & Zidane, I. F. (2023) · JOURNAL OF MECHANICAL ENGINEERING AND SCIENCES · doi:10.15282/jmes.17.1.2023.5.0739 · Cited by 3
Ren, J., Xia, Z., Chen, B., Li, W., Liu, D., & Sun, X. (2024) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2024.05.035 · Cited by 3
Rossi, M. C., Escuder, Á. V., Panadero, R. A., Pólo, M. G., Peñalver, P., & Borrás, V. A. (2024) · IntechOpen eBooks · doi:10.5772/intechopen.1005426 · Cited by 3
Jain, J., Sethuraman, R., & Shah, S. J. (2025) · The Journal of Indian Prosthodontic Society · doi:10.4103/jips.jips_179_24 · Cited by 3
“[2,3] Further evidence‑based guidelines, the WHO and “The Mcgill Consensus” states that “a minimum of two implants in the anterior mandibular canine region, used to retrain a lower complete denture is the minimum recommended treatment for mandibular edentulism.””
Shetty, R. M., Gopalakrishna, S., Bollineni, U., & Singh, I. (2018) · World Journal of Dentistry · doi:10.5005/jp-journals-10015-1535 · Cited by 3
“World Journal of Dentistry, May-June 2018;9(3):208-214 209 WJD”
BackgroundInfluentialAnterior Cervical Corpectomy and Fusion with the C-VBR
Castro, F. P., & Majd, M. E. (2018) · eScholarship (California Digital Library) · Cited by 3
Vogel, S., Ullm, F., Müller, C. D., Pompe, W., & Hempel, U. (2021) · Biological Chemistry · doi:10.1515/hsz-2021-0212 · Cited by 3
“The stiffness of bone marrow was shown with <300 Pa (Shin et al. 2013) to be within our experimental range, well below the stiffness of mineralized bone up to 10 GPa (Rho et al. 1993).”
A scaled framework for analysis of crack propagation in teeth using equivalent inorganic materials
Khoei, M. A., Darvizeh, A., Sadeghi, H., Maghrour, A., & Darvizeh, A. (2022) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062221079502 · Cited by 3
FORSTERITE AS AN ALTERNATIVE FOR ORTHOPAEDIC IMPLANTS – SHORT REVIEW
Avram, A., Mocanu, A., Tomoaia, G., & Tomoaia-Cotişel, M. (2021) · Annals of the Academy of Romanian Scientists Series on Physics and Chemistry · doi:10.56082/annalsarsciphyschem.2021.2.32 · Cited by 3
Güven, M. E., & Üşümez, A. (2023) · Medical Science and Discovery · doi:10.36472/msd.v10i10.1093 · Cited by 3
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.