Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 101–200 of 1,000
Homminga, J. J., Weinans, H., Gowin, W., Felsenberg, D., & Huiskes, R. (2001) · Spine · doi:10.1097/00007632-200107150-00010 · Cited by 158
Saab, X. E., Griggs, J. A., Powers, J. M., & Engelmeier, R. L. (2007) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2006.12.002 · Cited by 160
Li, J., Cui, X., Hooper, G. J., Lim, K. S., & Woodfield, T. B. F. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.103671 · Cited by 155
Ito, M., Nishida, A., Koga, A., Ikeda, S., Shiraishi, A., Uetani, M., Hayashi, K., & Nakamura, T. (2002) · Bone · doi:10.1016/s8756-3282(02)00830-x · Cited by 155
Hellmich, C., Ulm, F., & Dormieux, L. (2004) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-004-0040-0 · Cited by 159
Shahar, R., Zaslansky, P., Barak, M. M., Friesem, A. A., Currey, J. D., & Weiner, S. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.01.021 · Cited by 158
Azuri, I., Adler‐Abramovich, L., Gazit, E., Hod, O., & Kronik, L. (2013) · Journal of the American Chemical Society · doi:10.1021/ja408713x · Cited by 152
Experimental Validation of a Finite Element Model of a Human Cadaveric Tibia
Gray, H. A., Taddei, F., Zavatsky, A. B., Cristofolini, L., & Gill, H. S. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2913335 · Cited by 151
Passive myocardial mechanical properties: meaning, measurement, models
Emig, R., Zgierski-Johnston, C. M., Timmermann, V., Taberner, A. J., Nash, M. P., Köhl, P., & Peyronnet, R. (2021) · Biophysical Reviews · doi:10.1007/s12551-021-00838-1 · Cited by 152
北村, 絵., Stegaroiu, R., NOMURA, S., & Miyakawa, O. (2005) · Journal of Oral Rehabilitation · doi:10.1111/j.1365-2842.2004.01413.x · Cited by 151
The dependence of ultrasonic properties on orientation in human vertebral bone
Nicholson, P., Haddaway, M. J., & Davie, M. W. J. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/6/007 · Cited by 150
Chmielewska, A., & Dean, D. (2023) · Acta Biomaterialia · doi:10.1016/j.actbio.2023.11.011 · Cited by 149
Trabecular bone's mechanical properties are affected by its non-uniform mineral distribution
van der Linden, J. C., Birkenhäger-Frenkel, D. H., Verhaar, J. A. N., & Weinans, H. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00146-4 · Cited by 149
“Therefore, numerous studies have quantified strength, stiffness and failure load of cortical and trabecular bone (Choi et al., 1990; Currey, 1988; Keaveny et al., 1994; Mosekilde, 1989; Rho et al., 1993).”
BackgroundFracture of bone tissue: The ‘hows’ and the ‘whys’
Gupta, H. S., & Zioupos, P. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.007 · Cited by 129
Structural and material mechanical properties of human vertebral cancellous bone
Nicholson, P., Cheng, X. G., Lowet, G., Boonen, S., Davie, M. W. J., Dequeker, J., & der Perre, G. V. (1997) · Medical Engineering & Physics · doi:10.1016/s1350-4533(97)00030-1 · Cited by 148
Park, S. H., Park, D. S., Shin, J. W., Kang, Y. G., Kim, H. K., Yoon, T. R., & Shin, J. (2012) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-012-4738-8 · Cited by 146
“0 MPa lower than that of PLGA, which has stiffness lower than that of bone [24–26].”
BackgroundDependence of the mechanical properties of sintered hydroxyapatite on the sintering temperature
Prokopiev, O., & Sevostianov, I. (2006) · Materials Science and Engineering A · doi:10.1016/j.msea.2006.05.158 · Cited by 145
Okumura, N., Stegaroiu, R., 北村, 絵., Kurokawa, K., & Nomura, S. (2010) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2009.12.004 · Cited by 144
“The elastic properties used were taken from the literature [28–32], as shown in Table 1.”
MethodSaidin, S., Kadir, M. R. A., Sulaiman, E., & Kasim, N. H. A. (2012) · Journal of Dentistry · doi:10.1016/j.jdent.2012.02.009 · Cited by 144
Lee, C. A., & Einhorn, T. A. (2001) · Elsevier eBooks · doi:10.1016/b978-012470862-4/50002-7 · Cited by 146
Neufurth, M., Wang, X., Wang, S., Steffen, R., Ackermann, M., Haep, N. D., Schröder, H. C., & Müller, W. E. G. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2017.09.031 · Cited by 144
Fluid dynamic comparison of intra-atrial and extracardiac total cavopulmonary connections
Lardo, A. C., Webber, S. A., Friehs, I., del Nido, P. J., & Cape, E. G. (1999) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(99)70289-8 · Cited by 143
Magnesium alloys as extremely promising alternatives for temporary orthopedic implants – A review
Niranjan, C. A., Raghavendra, T., Rao, M. P., Siddaraju, C., Gupta, M. K., Jain, V. K. S., & Aishwarya, R. (2023) · Journal of Magnesium and Alloys · doi:10.1016/j.jma.2023.08.002 · Cited by 140
Cochis, A., Azzimonti, B., Valle, C. D., Giglio, E. D., Bloise, N., Visai, L., Cometa, S., Rimondini, L., & Chiesa, R. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.11.042 · Cited by 139
Huber, D., Oskooei, A., Solvas, X. C. I., deMello, A. J., & Kaigala, G. V. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00317 · Cited by 141
Comparison of micro-level and continuum-level voxel models of the proximal femur
Verhulp, E. E., van Rietbergen, B., & Huiskes, R. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.10.027 · Cited by 139
Bourne, B. C., & van der Meulen, M. C. H. (2003) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.10.002 · Cited by 138
“Rho et al. (1993) reported that such a power relationship may be extrapolated to calculate tissue modulus from tissue density.”
BackgroundFerretti, J. L. (1995) · Bone · doi:10.1016/8756-3282(95)00313-3 · Cited by 139
Two-dimensional MoS 2 electromechanical actuators
Hung, N. T., Nugraha, A. R. T., & Saito, R. (2018) · Journal of Physics D Applied Physics · doi:10.1088/1361-6463/aaa68f · Cited by 136
Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone
Lee, S. C., Coan, B. S., & Bouxsein, M. (1997) · Bone · doi:10.1016/s8756-3282(97)00076-8 · Cited by 136
Antimicrobial and Osseointegration Properties of Nanostructured Titanium Orthopaedic Implants
Jäger, M., Jennissen, H. P., Dittrich, F., Fischer, A., & Köhling, H.-L. (2017) · Materials · doi:10.3390/ma10111302 · Cited by 136
Ultrasonic scattering from cancellous bone: A review
Wear, K. A. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.818 · Cited by 135
Effects of running speed on a probabilistic stress fracture model
Edwards, W. B., Taylor, D. M., Rudolphi, T. J., Gillette, J. C., & Derrick, T. R. (2010) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2010.01.001 · Cited by 138
“4 GPa (Rho et al., 1993).”
Charrière, E., Lemaître, J., & Zysset, P. K. (2002) · Biomaterials · doi:10.1016/s0142-9612(02)00406-4 · Cited by 132
Mechanical and Architectural Bone Adaptation in Early Stage Experimental Osteoarthritis
Boyd, S. K., Müller, R., & Zernicke, R. F. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.4.687 · Cited by 134
“, testing orientation of direct contact methods may correlate with tissue anisotropy).((31,32)) Although we are not aware of any canine tissue modulus data specifically, our current results fall within this broad range.”
BackgroundSoro, N., Saintier, N., Merzeau, J., Veidt, M., & Dargusch, M. S. (2020) · Additive manufacturing · doi:10.1016/j.addma.2020.101653 · Cited by 129
PEEK surface modification by fast ambient-temperature sulfonation for bone implant applications
Wang, W., Luo, C., Huang, J., & Edirisinghe, M. J. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0955 · Cited by 125
“For example, Young’s modulus of human trabecular and cortical bone is between 10.4+ 3.5 and 20.7+1.9 GPa [1,2], whereas Young’s moduli of materials widely used for bone implant applications such as titanium, stainless steel and cobalt chromium alloys are approximately 110 GPa, 180 GPa and 210 GPa, respectively [3,4].”
BackgroundInfluentialBe’eri, E., Maier, S. E., Landzberg, M. J., Chung, T., & Geva, T. (1998) · Circulation · doi:10.1161/01.cir.98.25.2873 · Cited by 124
Matrix Stiffness: A Regulator of Cellular Behavior and Tissue Formation
Mason, B. N., Califano, J. P., & Reinhart‐King, C. A. (2011) · Springer eBooks · doi:10.1007/978-1-4614-1080-5_2 · Cited by 126
“In the body, tissue stiffness ranges several orders of magnitude, from adipose tissue (Young’s Modulus E ~ several kPa) [106] to bone (E ~ GPa) [99].”
BackgroundHuang, B., Vyas, C., Roberts, I. V., Poutrel, Q.-A., Chiang, W., Blaker, J. J., Huang, Z., & Bártolo, P. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.12.100 · Cited by 123
Properties of growing trabecular ovine bone: PART I: MECHANICAL AND PHYSICAL PROPERTIES
Nafei, A., Danielsen, C. C., Linde, F., & Hvid, I. (2000) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.82b6.9836 · Cited by 124
The mechanics of foams: basic results
Gibson, L. J., & Ashby, M. F. (1997) · Cambridge University Press eBooks · doi:10.1017/cbo9781139878326.007 · Cited by 122
Madeo, A., George, D., Lekszycki, T., Nierenberger, M., & Rémond, Y. (2012) · Comptes Rendus Mécanique · doi:10.1016/j.crme.2012.05.003 · Cited by 121
“[69–71]), so that the considered expression for the deformation energy should be generalized to describe such more”
BackgroundMechanical Properties of a Newly Additive Manufactured Implant Material Based on Ti-42Nb
Schulze, C., Weinmann, M., Schweigel, C., Keßler, O., & Bader, R. (2018) · Materials · doi:10.3390/ma11010124 · Cited by 120
Wang, C. X., Zhou, X., & Wang, M. (2004) · Materials Characterization · doi:10.1016/j.matchar.2004.06.007 · Cited by 119
Mechanical properties of vertebrate hard tissues
Currey, J. D. (1998) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1243/0954411981534178 · Cited by 118
Murchio, S., Dallago, M., Zanini, F., Carmignato, S., Zappini, G., Berto, F., Maniglio, D., & Benedetti, M. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104495 · Cited by 116
Finite element modeling of damage accumulation in trabecular bone under cyclic loading
Guo, X.-D. E., McMahon, T. A., Keaveny, T. M., Hayes, W. C., & Gibson, L. J. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90203-8 · Cited by 115
3D In Vitro Models for Investigating the Role of Stiffness in Cancer Invasion
Micalet, A., Moeendarbary, E., & Cheema, U. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01530 · Cited by 113
Kohal, R., Wolkewitz, M., & Tsakona, A. (2011) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2010.02067.x · Cited by 113
“The resin had a modulus of elasticity of approximately 12 Gpa, which approximated that of human bone (10–18 GPa) (Rho et al. 1993).”
BackgroundIncreasing strength of a biomedical Ti-Nb-Ta-Zr alloy by alloying with Fe, Si and O
Stráský, J., Harcuba, P., Bartha∥, K., Fekete, K., Landa, M., Srba, O., & Janeček, M. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.03.026 · Cited by 112
“Typical elastic modulus of Ti and common Ti alloys is around 100 GPa, while elastic modulus of the cortical bone ranges from 20 to 30 GPa and elastic modulus of cancellous bone is even lower (7–15 GPa) (Niinomi et al., 2012, Rho et al., 1993, Zysset et al., 1999).”
Nian, Y., Wan, S., Wang, X., Zhou, P., Avcar, M., & Li, M. (2022) · Engineering Structures · doi:10.1016/j.engstruct.2022.115404 · Cited by 112
Anwendung von Bone-Remodeling-Theorien zur Simulation orthodontischer Zahnbewegungen
Bourauel, C. P., Vollmer, D., & Jäger, A. (2000) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/s000560050012 · Cited by 111
Design of dental implants at materials level: An overview
Jiang, X., Yao, Y., Tang, W., Han, D., Zhang, L., Zhao, K. X., Wang, S., & Meng, Y. (2020) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.36931 · Cited by 109
Mineralization of Biomaterials for Bone Tissue Engineering
Wu, X., Walsh, K., Hoff, B. L., & Camci‐Unal, G. (2020) · Bioengineering · doi:10.3390/bioengineering7040132 · Cited by 110
Li, T., Kong, L., Wang, Y., Hu, K., Song, L., Liu, B., Li, D., Shao, J., & Ding, Y. (2009) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2009.07.001 · Cited by 109
Multi-scale modelling of elastic moduli of trabecular bone
Hamed, E., Jasiuk, I., Yoo, A. C., Lee, Y., & Liszka, T. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0814 · Cited by 111
Shim, V. P. W., Yang, L., Liu, J. F., & Lee, V. S. (2005) · International Journal of Impact Engineering · doi:10.1016/j.ijimpeng.2005.03.006 · Cited by 107
Effects of macropore size in carbonate apatite honeycomb scaffolds on bone regeneration
Hayashi, K., Munar, M. L., & Ishikawa, K. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.110848 · Cited by 106
Environmental physical cues determine the lineage specification of mesenchymal stem cells
Huang, C., Dai, J., & Zhang, X. A. (2015) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/j.bbagen.2015.02.011 · Cited by 105
“Bone has a Young’s modulus of ~10–20 Gpa [77], which results apparently from calcification after osteogenic differentiation.”
BackgroundLi, T., Hu, K., Cheng, L., Ding, Y., Ding, Y., Shao, J., & Kong, L. (2010) · Applied Mathematical Modelling · doi:10.1016/j.apm.2010.07.008 · Cited by 105
Clinical Use of Opportunistic Computed Tomography Screening for Osteoporosis
Anderson, P. A., Polly, D. W., Binkley, N., & Pickhardt, P. J. (2018) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.17.01376 · Cited by 105
Sawatari, T., Tsumura, H., Iesaka, K., Furushiro, Y., & Torisu, T. (2005) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2004.06.007 · Cited by 104
Beheshtizadeh, N., Gharibshahian, M., Pazhouhnia, Z., Rostami, M., Zangi, A. R., Maleki, R., Azar, H. K., Zalouli, V., Rajavand, H., Farzin, A., et al. (2022) · Biomedicine & Pharmacotherapy · doi:10.1016/j.biopha.2022.113431 · Cited by 105
Biomechanical Assessment of a PEEK Rod System for Semi-Rigid Fixation of Lumbar Fusion Constructs
Gornet, M. F., Chan, F. W., Coleman, J. C., Murrell, B., Nockels, R. P., Taylor, B. A., Lanman, T. H., & Ochoa, J. A. (2011) · Journal of Biomechanical Engineering · doi:10.1115/1.4004862 · Cited by 103
“However limitations to titanium include artifactual interference with postoperative imaging and elastic modulus that, while about half that of stainless steel, is up to 20 times greater than bone [18–20], which may grossly alter the physiologic distribution of load at the instrumented levels.”
BackgroundTrabecular bone adaptation with an orthotropic material model
Miller, Z., Fuchs, M. B., & Arcan, M. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00192-0 · Cited by 103
Food mechanical properties and dietary ecology
Berthaume, M. A. (2016) · American Journal of Physical Anthropology · doi:10.1002/ajpa.22903 · Cited by 103
“…heterogeneous, but some can be treated as orthotropic, transversely isotropic, isotropic and/or homogeneous (Currey and Butler, 1975; Ashman, 1988; Rho et al., 1993, 1995; Peterson and Dechow, 2002, 2003; Dumont et al., 2005, 2012; Peterson et al., 2006; Wang et al., 2006; Currey, 2006; Dechow et…”
BackgroundHaase, K., & Rouhi, G. (2013) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2013.07.032 · Cited by 102
Vairo, G., & Sannino, G. (2013) · Computational and Mathematical Methods in Medicine · doi:10.1155/2013/250929 · Cited by 104
The evaluation of new multi-material human soft tissue simulants for sports impact surrogates
Payne, T., Mitchell, S. R., Bibb, R., & Waters, M. G. J. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.09.018 · Cited by 102
“Cortical bone is significantly stiffer than trabecular bone (Rho et al., 1993) and it is believed that this constitutes a more significant part of the overall tissue response and is therefore deemed appropriate as an initial simplification; an Ogden model fit for cortical bone is similarly detailed…”
Structural and mechanical characterization of nanoclay-reinforced agarose nanocomposites
Li, X., Gao, H., Scrivens, W. A., Fei, D., Thakur, V., Sutton, M. A., Reynolds, A. P., & Myrick, M. L. (2005) · Nanotechnology · doi:10.1088/0957-4484/16/10/006 · Cited by 100
Raum, K. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.817 · Cited by 101
Theoretical and Empirical Scaling Patterns and Topological Homology in Bone Trabeculae
Swartz, S. M., Parker, A., & Huo, C. (1998) · Journal of Experimental Biology · doi:10.1242/jeb.201.4.573 · Cited by 100
Experimental Techniques for Bone Mechanics
Turner, C. H., & Burr, D. B. (2001) · CRC Press eBooks · doi:10.1201/b14263-10 · Cited by 101
Self-citationAnatomic variation in the elastic anisotropy of cortical bone tissue in the human femur
Orías, A. A. E., Deuerling, J. M., Landrigan, M. D., Renaud, J. E., & Roeder, R. K. (2008) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2008.08.005 · Cited by 100
Cell-material interactions in tendon tissue engineering
Lin, J., Zhou, W., Han, S., Bunpetch, V., Zhao, K., Liu, C., Yin, Z., & Ouyang, H. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.01.012 · Cited by 98
Reznikov, N., Boughton, O. R., Ghouse, S., Weston, A., Collinson, L., Blunn, G. W., Jeffers, J. R. T., Cobb, J. P., & Stevens, M. M. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.11.026 · Cited by 98
“Control structures were designed to match the material modulus of compact bone [33] (most stiff titanium control, TC), and to be below the modulus of trabecular bone (polyamide control, PC, with cubic symmetry, which is stable only in 3 principal loading direction and is compliant and easily deformable in all non-axia…”
BackgroundCaeiro, J. R., González, P., & Guede, D. (2013) · Revista de Osteoporosis y Metabolismo Mineral · doi:10.4321/s1889-836x2013000200007 · Cited by 99
Xu, Y., Zhang, D., Hu, S., Chen, R., Gu, Y., Xiangsen, K., Tao, J., & Jiang, Y. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.06.021 · Cited by 96
Parande, G., Manakari, V., Kopparthy, S. D. S., & Gupta, M. K. (2019) · Composites Part B Engineering · doi:10.1016/j.compositesb.2019.107650 · Cited by 96
Preparation and characterization of Ti-15Mo alloy used as biomaterial
Júnior, J. R. S. M., Nogueira, R. A., de Araújo, R. O., Donato, T. A. G., Arana-Chavez, V. E., Claro, A. P. R. A., Moraes, J. C. S., Buzalaf, M. A. R., & Grandini, C. R. (2011) · Materials Research · doi:10.1590/s1516-14392011005000013 · Cited by 95
Oppenheimer, A. J., Monson, L. A., & Buchman, S. R. (2013) · Craniomaxillofacial Trauma & Reconstruction · doi:10.1055/s-0032-1332213 · Cited by 93
Simulation of ultrasonic pulse propagation, distortion, and attenuation in the human chest wall
Mast, T. D., Hinkelman, L. M., Metlay, L. A., Orr, M. J., & Waag, R. C. (1999) · The Journal of the Acoustical Society of America · doi:10.1121/1.428209 · Cited by 93
Stretching the Function of Innate Immune Cells
Orsini, E. M., Perelas, A., Southern, B. D., Grove, L. M., Olman, M. A., & Scheraga, R. G. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.767319 · Cited by 93
Vaughan, T. J., McCarthy, C. T., & McNamara, L. M. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.03.003 · Cited by 92
“…testing (Ryan and Williams 1989; Rho et al. 1993; Samelin et al. 1996; McNamara et al. 2005; McNamara et al. 2006a), ultrasonic measurement (Rho et al. 1993) and nanoindentation (Rho et al. 1997; Rho et al. 1999; Zysset et al. 1999; Hoffler et al. 2000; Ferguson et al. 2003; Ozcivici et…”
InfluentialBone stress for a mini-implant close to the roots of adjacent teeth - 3D finite element analysis
Motoyoshi, M., Ueno, S., Okazaki, K., & Shimizu, N. (2009) · International Journal of Oral and Maxillofacial Surgery · doi:10.1016/j.ijom.2009.02.011 · Cited by 92
Analysis of mechanical properties of cancellous bone under conditions of simulated bone atrophy
Müller, R., & Ruegsegger, P. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00006-1 · Cited by 92
Novitskaya, E. E., Chen, P., Hamed, E., Jun, L., Lubarda, V. A., Jasiuk, I., & McKittrick, J. M. (2011) · Theoretical and Applied Mechanics · doi:10.2298/tam1103209n · Cited by 93
Chemical and physical properties of regenerative medicine materials controlling stem cell fate
Kaivosoja, E., Barreto, G., Levón, K., Virtanen, S., Ainola, M., & Konttinen, Y. T. (2011) · Annals of Medicine · doi:10.3109/07853890.2011.573805 · Cited by 91
“1 – 1 kPa in neural tissue (85) to 20 GPa in cortical bone (86).”
BackgroundStakleff, K. S., Lin, F., Callahan, L. A. S., Wade, M. B., Esterle, A. R., Miller, J. K., Graham, M., & Becker, M. L. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2012.08.035 · Cited by 89
“Resorbable polymers that are stable at physiological temperatures (Tg > 40 C) and possess high elastic moduli (>3.5 GPa) are needed for many medical and pharmaceutical applications [29,47–51].”
BackgroundInfluentialUnune, D. R., Brown, G. R., & Reilly, G. C. (2022) · Vacuum · doi:10.1016/j.vacuum.2022.111298 · Cited by 89
4D Printing: Enabling Technology for Microrobotics Applications
Adam, G., Benouhiba, A., Rabenorosoa, K., Clévy, C., & Cappelleri, D. J. (2021) · Advanced Intelligent Systems · doi:10.1002/aisy.202000216 · Cited by 88
Comparison of stress on knee cartilage during kneeling and standing using finite element models
Wang, Y., Fan, Y., & Zhang, M. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.01.004 · Cited by 88
Gíslason, M. K., Stansfield, B. W., & Nash, D. (2010) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2010.02.015 · Cited by 87
Architected implant designs for long bones: Advantages of minimal surface-based topologies
Hsieh, M.-T., Begley, M. R., & Valdevit, L. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.109838 · Cited by 87
“tibia 18 [77], 8–23 [79], 17 [80], 15 [81], 18[82]”
Additive manufacturing for biomedical bone implants: Shaping the future of bones
Razzaq, M. H., Zaheer, M. U., Asghar, H., Aktas, O. C., Aycan, M. F., & Mishra, Y. K. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.100931 · Cited by 88
Kang, K., Koh, Y., Son, J., Yeom, J. S., Park, J.-H., & Kim, H. (2017) · Composites Part B Engineering · doi:10.1016/j.compositesb.2017.07.052 · Cited by 87
PEEK-Halo effect in interbody fusion
Phan, K. H., Hogan, J. A., Assem, Y., & Mobbs, R. J. (2015) · Journal of Clinical Neuroscience · doi:10.1016/j.jocn.2015.07.017 · Cited by 86
“6 GPa versus 110 GPa) [7]; and (3) minimisation of stress shielding compared to solid titanium implants [3].”
BackgroundInfluentialMcNamara, L. M., EDERVEEN, A. G. H., Lyons, C. G., Price, C., Schaffler, M. B., Weinans, H., & Prendergast, P. J. (2006) · Bone · doi:10.1016/j.bone.2006.02.070 · Cited by 83
“Test methods applied have included 3/4-point bending [28,29], buckling [30,31], cantilever beam tests [32], microtensile testing [33–35] and ultrasonic measurement [ 34 ].”
MethodHydroxyapatite Reinforced Chitosan and Polyester Blends for Biomedical Applications
Correlo, V. M., Boesel, L. F., Bhattacharya, M., Mano, J. F., Neves, N. M., & Reis, R. L. (2005) · Macromolecular Materials and Engineering · doi:10.1002/mame.200500163 · Cited by 74
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.