Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 701–800 of 1,000
Zec, M. L., Thistlethwaite, P. A., Frank, C. B., & Shrive, N. G. (2009) · Journal of Biomechanical Engineering · doi:10.1115/1.4000108 · Cited by 12
Análise biomecânica da reconstrução do ligamento cruzado anterior
Completo, A., Noronha, J. C., Oliveira, C., & Fonseca, F. M. F. (2019) · Revista Brasileira de Ortopedia · doi:10.1016/j.rbo.2017.11.008 · Cited by 13
Jacobs, N., Seghi, R. R., Johnston, W. M., & Yılmaz, B. (2021) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2020.11.008 · Cited by 12
Yamane, Y., Yabutsuka, T., Takaoka, Y., Ishizaki, C., Takai, S., & Fujibayashi, S. (2021) · Materials · doi:10.3390/ma14216691 · Cited by 12
“In general, the elastic modulus of human bone is approximately 20 GPa for cortical bone and 4–10 GPa for cancellous bone, respectively [1].”
BackgroundShear wave elastography and Doppler ultrasound in kidney transplant recipients
Gonçalves, L. M., Forte, G. C., Holz, T. G., Libermann, L. L., Poli‐de‐Figueiredo, C. E., & Hochhegger, B. (2022) · Radiologia Brasileira · doi:10.1590/0100-3984.2020.0148 · Cited by 12
Heary, R. F., Parvathreddy, N. K., Qayumi, Z. S., Ali, N. S., & Agarwal, N. (2016) · Journal of Neurosurgery Spine · doi:10.3171/2016.1.spine14291 · Cited by 12
Qiu, L. G., Hughes-Brittain, N. F., Bastiaansen, C. W. M., Peijs, T., & Wang, W. (2016) · Journal of Functional Biomaterials · doi:10.3390/jfb7040033 · Cited by 12
“PMMA has proven to exhibit good biocompatibility and is in wide clinic use, such as in rigid intraocular lenses [29], bone cement [30], dental filling, dentures [31] and cosmetic surgery [32].”
BackgroundFrame, J. C., Wheel, M. A., & Riches, P. E. (2017) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2903 · Cited by 12
“3, respectively.(34-36) Two‐dimensional FE meshes were used to represent beam‐like test samples of the representative material in which the channels were orientated transverse to both the sample major and minor axes.”
MethodLocal bone quality measurements correlates with maximum screw torque at the femoral diaphysis
McAndrew, C. M., Agarwalla, A., Abraham, A. C., Feuchtbaum, E., Ricci, W. M., & Tang, S. Y. (2018) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2018.01.016 · Cited by 12
“Although there are a number of non-invasive approaches to measure bone material properties in vivo, including ultrasound microscopy and FTIR, they are currently developmental stages of clinical translation (Rho et al., 1993).”
Chillale, T. P., Kim, N. H., & Smith, L. N. (2019) · Military Medicine · doi:10.1093/milmed/usy382 · Cited by 12
Alaqeely, R., Babay, N., & Alqutub, M. N. (2019) · The Saudi Dental Journal · doi:10.1016/j.sdentj.2019.06.001 · Cited by 12
“2a and b) were used to resemble the elastic and plastic deformation that can occur in bone with the application of forces (Rho et al., 1993).”
Concurrent consideration of cortical and cancellous bone within continuum bone remodelling
Schmidt, I., Papastavrou, A., & Steinmann, P. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1880573 · Cited by 12
“With a true elastic modulus of Es ¼ 10, 000, which is similarly documented for solid trabecular material by Rho et al. (1993) and Yamada et al. (2014), and based on the quadratic relation N ¼ n ¼ 2 between stiffness and nominal density according to Gibson (2005), this results in a nominal stiffness…”
BackgroundInfluentialAndersen, P. J. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00012-x · Cited by 12
Zerwekh, J. E., Antich, P. P., Mehta, S. S., Sakhaee, K., Gottschalk, F., & Pak, C. Y. C. (1997) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1997.12.12.2068 · Cited by 12
“transmission or reflection ultrasound methodologies, are deterministically related to bone elasticity.((9,14,23,24)) Furthermore, elasticity predicts bone strength at the material level for normal bone((12)) and after NaF treatment.”
BackgroundSimulations of mechanical adaptation and their relationship to stress bearing in skeletal tissue
Hirschberg, J. (2005) · UWA Profiles and Research Repository (UWA) · Cited by 12
Bone Ingrowth Simulation Within the Hexanoid, a Novel Scaffold Design
Wang, Y., Wang, L., Soro, N., Buenzli, P. R., Li, Z., Green, N., Tetsworth, K. D., & Erbulut, D. U. (2023) · 3D Printing and Additive Manufacturing · doi:10.1089/3dp.2023.0113 · Cited by 11
Hydroxyapatite scaffolds derived from deer antler: Structure dependence on processing temperature
González-Rodríguez, L., López‐Álvarez, M., Astray, S., Solla, E. L., Serra, J., & González, P. (2019) · Materials Characterization · doi:10.1016/j.matchar.2019.109805 · Cited by 11
Enhancing biomedical data validity with standardized segmentation finite element analysis
Wysocki, M. A., & Doyle, S. T. (2022) · Scientific Reports · doi:10.1038/s41598-022-13961-0 · Cited by 11
Gibbons, M. M., & Chen, D. A. (2022) · Biomimetics · doi:10.3390/biomimetics7020082 · Cited by 11
“, it has a large Young’s modulus) [13].”
BackgroundContribution of joint tissue properties to load-induced osteoarthritis
Ayobami, O. O., Goldring, S. R., Goldring, M. B., Wright, T. M., & van der Meulen, M. C. H. (2022) · Bone Reports · doi:10.1016/j.bonr.2022.101602 · Cited by 11
“3, based on values from the literature (Rho et al., 1993).”
BackgroundFinite Element Analysis of Normal and Dysplastic Hip Joints in Children
Incze-Bartha, Z., Incze-Bartha, S., Simon-Szabó, Z., Feier, A. M., Vunvulea, V., Nechifor-Boilă, I. A., Pastorello, Y., Szasz, D., & Dénes, L. (2023) · Journal of Personalized Medicine · doi:10.3390/jpm13111593 · Cited by 11
“For model validation, the mechanical properties of the adult bone were considered [17–19].”
MethodDesign and Development of Ti–Zr–Nb–Ta–Ag High Entropy Alloy for Bioimplant Applications
Hussein, M. A., Azeem, M. A., Kumar, A. M., & Ankah, N. K. (2024) · Advanced Engineering Materials · doi:10.1002/adem.202400462 · Cited by 11
Pandey, M., Mairal, A., Gupta, H., Kumar, A., & Bhattacharya, S. (2024) · Surfaces and Interfaces · doi:10.1016/j.surfin.2024.105117 · Cited by 11
Bio-Instructive Scaffolds for Musculoskeletal Interfaces
Banik, B. L., Bowers, D. T., Fattahi, P., & Brown, J. L. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-803394-4.00009-4 · Cited by 11
Tang, F., Zhou, Y., Zhang, W., Min, L., Shi, R., Luo, Y., Duan, H., & Tu, C. (2017) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-017-0555-6 · Cited by 11
Hosseinitabatabaei, S., Ashjaee, N., & Tahani, M. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-017-0267-8 · Cited by 11
Alqarni, H., AlHelal, A. A., Jekki, R., Kattadiyil, M. T., Sayed, M. E., Jain, S., Vahdati, S. A., & Dehom, S. O. (2022) · Applied Sciences · doi:10.3390/app122311896 · Cited by 11
Thermal effects of laser-osteotomy on bone: Mathematical computation using maple
Baradaran‐Ghahfarokhi, M., Gholami, A., Baradaran-Ghahfarokhi, M., & Ebrahimi, M. (2013) · Journal of Medical Signals & Sensors · doi:10.4103/2228-7477.128342 · Cited by 11
“e r p 2 4 4 ω (1) Table 1: Thermo-mechanical characteristics of the cortical bone Parameter Value Young’s modulus (E) (GPa)[14] 14.”
The Optimization of a Porous Ti6Al4V Bone Construct Using Additive Manufacturing
Wilk, J. T., Sanders, G., Marks, S., Paolicelli, S., DiCaprio, M. R., & Bucinell, R. (2017) · American Journal of Engineering and Applied Sciences · doi:10.3844/ajeassp.2017.13.19 · Cited by 11
“Pore density was then increased until the modulus of the implant reached that of cortical bone (10-21 GPa) (Rho et al., 1993).”
BackgroundCoulaud, J., Brumas, V., Fiallo, M. M. L., Sharrock, P., Gonneau, É., Courbon, F., & Caselles, O. (2018) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aaac68 · Cited by 11
Fabrication and characterization of nHA/titanium dental implant
Sazesh, S., Ghassemi, A., Ebrahimi‐Kahrizsangi, R., & Khodaei, M. (2019) · Materials Research Express · doi:10.1088/2053-1591/aafddc · Cited by 11
Kikuchi, S., Nakamura, Y., Nambu, K., & Akahori, T. (2019) · International Journal of Lightweight Materials and Manufacture · doi:10.1016/j.ijlmm.2019.06.001 · Cited by 11
Stimmelmayr, M., Lang, A., Beuer, F., Mansour, S., Erdelt, K. J., Krennmair, G., & Güth, J. (2019) · Clinical Oral Investigations · doi:10.1007/s00784-019-03043-3 · Cited by 11
“This simulated a peri-implant bone loss and the Young’s modulus of the material was 3450 MPa which represents type III bone density [10].”
BackgroundCollins, C. J., Kozyrev, M., Frank, M., Andriotis, O. G., Byrne, R. A., Kiener, H. P., Pretterklieber, M. L., & Thurner, P. J. (2019) · Materialia · doi:10.1016/j.mtla.2019.100573 · Cited by 11
Rai, A., Rai, P., Kumar, V., Singh, N. K., & Singh, V. K. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.04.123 · Cited by 11
B‐cell acquisition of antigen: Sensing the surface
Knight, A. M. (2015) · European Journal of Immunology · doi:10.1002/eji.201545684 · Cited by 11
Spatial patterning of bone stiffness variation in the colobine alveolar process
Daegling, D. J., Granatosky, M. C., McGraw, W. S., & Rapoff, A. J. (2010) · Archives of Oral Biology · doi:10.1016/j.archoralbio.2010.10.008 · Cited by 11
Effect of Compressive Straining on Nanoindentation Elastic Modulus of Trabecular Bone
Gan, M., Samvedi, V., Cerrone, A. R., Dubey, D. K., & Tomar, V. (2009) · Experimental Mechanics · doi:10.1007/s11340-009-9274-1 · Cited by 11
“At the nanoscale, trabecular bone tissue has been analyzed using a variety of experimental techniques, Townsend and Rose [5], Mente and Lewis [6], Katz and Meunier [7], Ashman et al. [ 8 ], Binia et al. [9], and Hengsberger et al. [10, 11].”
MethodBiocompatible functional surface of titanium-based implant materials
Masahashi, N., Mori, Y., & Inoue, H. (2025) · International Materials Reviews · doi:10.1177/09506608251345899 · Cited by 10
Srikitrungruang, T., Fard, S. A. D., Lemon, M., Lee, J., & Zhou, Y. (2025) · Advanced Science · doi:10.1002/advs.202508445 · Cited by 10
“[67, 68, 69] Figure 3 illustrates the calibration procedure employed in this study using numerical integration of the predicted relative stress under the applied loading force, where the technical details are described in Section 4.3.”
InfluentialHybprinting for musculoskeletal tissue engineering
Li, J., Kim, C., Pan, C., Babian, A., Lui, E., Young, J. L., Moeinzadeh, S., Kim, S., & Yang, Y. (2022) · iScience · doi:10.1016/j.isci.2022.104229 · Cited by 10
“Continued Material / Tissue Compressive modulus Tensile modulus Skin Muscle Bone Connective tissue (tendon, ligament, cartilage) Nerves Blood vessels Metals Co - Cr 2.33–197 GPa (Barazanchi et al., 2020; Han et al., 2017; Limmahakhun et al., 2017) 67–196.2 GPa (Barazanchi et al., 2020; Choi et al., 2014) (Curodeau et…”
BackgroundInfluentialA novel CKIP-1 SiRNA slow-release coating on porous titanium implants for enhanced osseointegration
Tang, R., Shao, C., Chen, L., Li, Y., Zhang, B., Tang, J., & Ma, W. (2022) · Biomaterials Advances · doi:10.1016/j.bioadv.2022.212864 · Cited by 10
The multiscale meso-mechanics model of viscoelastic cortical bone
Chen, Y., Wu, R., Yang, B., & Wang, G. (2022) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-022-01615-z · Cited by 10
Zanut, A., Li, R., Deng, R., Liu, X., Rejhon, M., Chen, W., Weck, M., de Peppo, G. M., & Riedo, E. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202201503 · Cited by 10
Finite Element Modelling Based Studies for Dental Implants: Systematic Review
Shakir, S. M., Muhsin, S. A., & Marza, R. A. (2022) · Journal of Techniques · doi:10.51173/jt.v4i33.771 · Cited by 10
Full-range stress–strain curve estimation of aluminum alloys using machine learning-aided ultrasound
Park, S., Chung, J., Yi, K., Sohn, H., & Jhang, K.-Y. (2023) · Ultrasonics · doi:10.1016/j.ultras.2023.107146 · Cited by 10
Hussein, M. A., Kumar, A. M., Azeem, M. A., & Ankah, N. K. (2023) · Materials Chemistry and Physics · doi:10.1016/j.matchemphys.2023.128413 · Cited by 10
Kosmopoulos, V., Luedke, C., & Nana, A. (2014) · Technology and Health Care · doi:10.3233/thc-140875 · Cited by 10
“Bone, plate, and screw material properties [9,16,28].”
Estado del arte en biocompatibilidad de recubrimientos
Posada, A. O. G., Aguirre, N. O., & Olaya, J. J. (2013) · Visión electrónica · doi:10.14483/22484728.4398 · Cited by 10
A micromechanical elastic property study of trabecular bone in the human mandible
Nomura, T., Katz, J. L., Powers, M. P., & Saito, C. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-2312-6 · Cited by 10
Cole, J. H., & van der Meulen, M. C. H. (2009) · Humana Press eBooks · doi:10.1007/978-1-59745-459-9_7 · Cited by 10
Influence of the Mn content on the TiNbxMn alloys with a novel fcc structure
Chicardi, E., Aguilar, C. E., Sayagués, M. J., & García-Garrido, C. (2018) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2018.02.306 · Cited by 10
Corrosion study of biodegradable magnesium based 1393 bioactive glass in simulated body fluid
Rai, P., Rai, A., Kumar, V., Chaturvedi, R. K., & Singh, V. K. (2019) · Ceramics International · doi:10.1016/j.ceramint.2019.05.234 · Cited by 10
Liu, S., Yang, H., Wang, M., Tian, J., Yuan, H., Li, Y., Genin, G. M., Lu, T. J., & Xu, F. (2021) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2021.104572 · Cited by 10
Initial fixation of a femoral knee component: an in vitro and finite element study
Burgers, T., Mason, J., & Ploeg, H. (2009) · International Journal of Experimental and Computational Biomechanics · doi:10.1504/ijecb.2009.022857 · Cited by 10
“Ultrasonic methods have been used to determine the elastic mechanical properties of bone by several other authors (Ashman et al., 1987, 1989; Rho et al., 1993; Rho, 1996; Turner and Eich, 1991; Williams and Johnson, 1989; Nicholson et al., 1997; Kim and Walsh, 1992) as well.”
InfluentialVibration Analysis of the Human Radius of Elderly Men
Sıngın, R. H. Ö., Sezgin, Ö. C., Akn, S., & Korkusuz, F. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000200250.12006.b8 · Cited by 10
“This can be explained by the comparatively dense structure of the cortical bone compared to that of the trabecular bone.(30,31) Cortical thickness also affects the average BMD in bones.”
BackgroundHamaluik, K. D., Moussa, W. A., & Ferguson-Pell, M. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2313082 · Cited by 10
“15 and density of 297 kg/m [29]–[31].”
The mechanical effects of extracorporeal irradiation on bone
Gupta, S., Cafferky, D., Cowie, F. J., Riches, P. E., & Mahendra, A. (2015) · The Bone & Joint Journal · doi:10.1302/0301-620x.97b8.35729 · Cited by 10
Hasan, M. S. (2012) · Nottingham ePrints (University of Nottingham) · Cited by 10
Melt electrowriting of hydrophilic/hydrophobic multiblock copolymers for bone tissue regeneration
Chandrakar, A., van der Spoel, M., Beeren, I. A. O., Giacomini, F., Mondadori, C., Eischen-Loges, M. J., Truckenmüller, R. K., Moroni, L., & Wieringa, P. A. (2025) · Biomaterials Advances · doi:10.1016/j.bioadv.2024.214167 · Cited by 9
Öztürk, O. B., Kartal, Ş. E., Turna, İ., PİRİM, A. E., Kurt, Z., Güvercin, Y., & Yaylacı, M. (2025) · Applied Ocean Research · doi:10.1016/j.apor.2025.104742 · Cited by 9
Biohybrid Tendons Enhance the Power‐to‐Weight Ratio and Modularity of Muscle‐Powered Robots
Castro, N., Heisser, R. H., Bawa, M., Aymon, B. F. G., Wu, S. J., Marschner, A., Kohli, S., Bu, A., Rosado, L., Culpepper, M. L., et al. (2025) · Advanced Science · doi:10.1002/advs.202512680 · Cited by 9
Zubaidi, S. H. A., Al-Sultan, M., & Hasan, L. A. (2023) · Journal of Orthodontic Science · doi:10.4103/jos.jos_16_23 · Cited by 9
“[10,11] The material properties for cortical and cancellous bone [12] and teeth [13] were listed in Table 1.”
BackgroundGupta, A., & Hiremath, S. S. (2023) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2023.130288 · Cited by 9
Mecanobiología de los huesos maxilares: I. Conceptos generales
Cano, J., Campo, J., Palacios, B., & Bascones, A. (2007) · Avances en Odontoestomatología · doi:10.4321/s0213-12852007000600002 · Cited by 9
2D-Finite element analysis of inlay-, onlay bridges with using various materials
Śmielak, B., Świniarski, J., Wołowiec‐Korecka, E., & Klimek, L. (2016) · Archives of Materials Science and Engineering · doi:10.5604/18972764.1229427 · Cited by 9
“On the other hand, although many studies have focused on the problem of studying the physical properties of the compact and cancellous bone, the reported values for these tissues vary significantly [37-39].”
BackgroundComposition Design and Nanoindentation Studies on Mg-Ca-Zn Metallic Glass
Prabhu, Y., Vincent, S., Nair, A., Kim, W., Park, E. S., & Bhatt, J. (2022) · Metallurgical and Materials Transactions A · doi:10.1007/s11661-022-06602-8 · Cited by 9
dos Santos, R. B., Lenz, U., Griggs, J. A., Estrela, C., Bueno, M. R., Porto, O. C. L., & Bona, Á. D. (2024) · Dental Materials · doi:10.1016/j.dental.2023.12.014 · Cited by 9
Durdu, S., Aktaş, S., Sarcan, F., Akagündüz, E., Gultekin, B., Erol, A., & Usta, M. (2024) · Journal of the Australian Ceramic Society · doi:10.1007/s41779-024-01030-w · Cited by 9
Micro‐CT based modelling for characterising injection‐moulded porous titanium implants
Chen, J., Chen, L., Chang, C., Zhang, Z., Li, W., Swain, M. V., & Li, Q. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2779 · Cited by 9
Patra, S., Mohanta, K. L., & Parida, C. (2019) · International Journal of Modern Physics B · doi:10.1142/s0217979219503053 · Cited by 9
Length scale parameter of single trabecula in cancellous bone
Khorshidi, M. A. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01316-5 · Cited by 9
Schulte, A. K., Alhusaini, Q. F. M., & Schönherr, H. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00153 · Cited by 9
Lee, S., Jeon, I. S., & Jho, J. Y. (2022) · Macromolecular Research · doi:10.1007/s13233-022-0028-6 · Cited by 9
Minimum solid area models applied to the prediction of Young's modulus for cancellous bone
O'Kelly, K. U., Carr, A., & McCormack, B. A. O. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1022944318435 · Cited by 9
Microtensile device for stress: Elongation tests on nonstandard specimens
Branca, F. P., & Marinozzi, F. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150644 · Cited by 9
Teo, J. C. M., Teo, E. Y., Shim, V. P. W., & Teoh, S. H. (2006) · Experimental Mechanics · doi:10.1007/s11340-006-8444-7 · Cited by 9
“84.5) [ 8 ]; average values for human and bovine femur are about 2,704 m/s (S.D.”
BackgroundMethodInfluentialHard Tissues, Mechanical Properties of
Rho, J. Y. (2001) · Elsevier eBooks · doi:10.1016/b0-08-043152-6/00664-1 · Cited by 9
Self-citationRho, J. Y., Roy, M. E., & Pharr, G. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00228-6 · Cited by 9
Self-citationWorlikar, T., Loudon, N., Khaykin, V. M., Zhang, M., Cho, C. S., Hall, T. J., Vlaisavljevich, E., Fowlkes, J. B., Parikh, N. D., Xu, Z., et al. (2025) · Radiology Imaging Cancer · doi:10.1148/rycan.240403 · Cited by 8
Singh, G., Singh, R., Singh, A. P., Husain, M., & Kumar, V. (2025) · Journal of Materials Engineering and Performance · doi:10.1007/s11665-025-11756-8 · Cited by 8
“The material with low stiffness is often preferred for implant applications as it promotes better load distribution and reduces stress shielding, improving bone integration and long-term stability (Ref 42-44).”
Vemparala, B., Ji, M., Mageswaran, P., Knapik, G. G., Dibs, K. N., Blakaj, D. M., Bourekas, E. C., Mendel, E., Marras, W. S., & Soghrati, S. (2025) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.70097 · Cited by 8
“The elastic modulus of the trabecular bone (in GPa ) can be evaluated as [53] where 𝜌 is in g ∕ mm 3 .”
Mao, S., Liu, Y., Wang, F., He, P., Wu, X., Ma, X., & Luo, Y. (2023) · International Journal of Bioprinting · doi:10.18063/ijb.735 · Cited by 8
“The material property of the patient’s tibia, according to previous reports[31,32], was assigned as cortical bone with an elastic modulus of 20,000 MPa and Poisson’s ratio of 0.”
Cisneros, T., Sevostianov, I., & Drach, B. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.105992 · Cited by 8
Advances in Structural Integrity and Failure
Bahrami, A., & Eshiet, K. (2023) · Civil engineering. · doi:10.5772/intechopen.1000457 · Cited by 8
González-Sánchez, M., Zamora‐Ledezma, C., Elango, J., & Morales‐Flórez, V. (2024) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2024.02.001 · Cited by 8
Incze-Bartha, Z., Incze-Bartha, S., Simon-Szabó, Z., Feier, A. M., Vunvulea, V., Nechifor-Boila, A. I., Pastorello, Y., & Dénes, L. (2024) · Journal of Personalized Medicine · doi:10.3390/jpm14020189 · Cited by 8
“For the model validation, we utilized adult bone material properties, which were For the model validation, we utilized adult bone material properties, which were also adopted from the literature [18–21]. also adopted from the literature [18–21].”
MethodLi, Z., Rehman, I. U., Shepherd, R., & Douglas, T. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15030055 · Cited by 8
“But, when considering the Young’s modulus of human trabecular bone tissues, which was previously reported to be in the range from 0.9 GPa to 2.0 GPa, the test results reveal that the chitosan-based porous scaffolds might not be ideal compared with other hard tissue engineering scaffolds [44,45].”
ResultInfluentialRehman, M., Wang, Y., Ishfaq, K., Mushtaq, R. T., & Alkahtani, M. S. (2024) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2024.09.209 · Cited by 8
EMG-Based Variable Impedance Control for Enhanced Haptic Feedback in Real-Time Material Recognition
Iovene, E., Monaco, R., Fu, J., Costa, F., Ferrigno, G., & Momi, E. D. (2025) · IEEE Transactions on Haptics · doi:10.1109/toh.2024.3524023 · Cited by 8
Extraction of a Bent Tibial Nail After Refracture: A Case Report
McChesney, G. R., Gurbani, B. N., & Hagedorn, J. C. (2019) · JBJS Case Connector · doi:10.2106/jbjs.cc.18.00385 · Cited by 8
Understanding the driving force for cell migration plasticity
Chen, J., Yan, D., & Chen, Y. (2023) · Biophysical Journal · doi:10.1016/j.bpj.2023.04.008 · Cited by 8
Study of Biomechanics of Porous Coated Root Form Implant Using Overdenture Attachment: A 3D FEA
Savadi, R. C., & Goyal, C. (2010) · The Journal of Indian Prosthodontic Society · doi:10.1007/s13191-010-0035-8 · Cited by 8
“The corresponding elastic properties such as Young’s Modulus (C=) and Poisson’s ratio (d) of cortical bone, cancellous bone and implant were determined (according to literature survey [11, 37, 38] as shown in Table 1).”
MethodMechanical behavior of human bones with different saturation levels
Cammarata, M., Nicoletti, F., Paola, M. D., Valenza, A., & Zummo, G. (2016) · International Electronic Conference on Materials (IOCMA) · doi:10.3390/ecm-2-b003 · Cited by 8
Verma, R., Singh, N., Rai, S., & Kumta, S. M. (2019) · Lecture notes on multidisciplinary industrial engineering · doi:10.1007/978-981-32-9072-3_80 · Cited by 8
Numerical and analytical simulation of multilayer cellular scaffolds
Khanaki, H. R., Rahmati, S., Nikkhoo, M., Haghpanahi, M., & Akbari, J. (2020) · Journal of the Brazilian Society of Mechanical Sciences and Engineering · doi:10.1007/s40430-020-02335-0 · Cited by 8
Salerno, M. (2012) · Measurement · doi:10.1016/j.measurement.2012.05.011 · Cited by 8
“[24,26] 0.”
Effect of ACL reconstruction tunnels on stress in the distal femur
Smolinski, P. J., O’Farrell, M., Bell, K. M., Gilbertson, L. G., & Fu, F. H. (2012) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-012-2003-9 · Cited by 8
Tensile Properties of Veins of Damselfly Wing
Talucdher, R., & Shivakumar, K. N. (2013) · Journal of Biomaterials and Nanobiotechnology · doi:10.4236/jbnb.2013.43031 · Cited by 8
“[15].”
The turnover of mineralized growth plate cartilage into bone may be regulated by osteocytes
Cox, L. G. E., van Rietbergen, B., van Donkelaar, C. C., & Ito, K. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.04.011 · Cited by 8
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.