Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 801–900 of 1,000
Hazenbiller, O., Nasr, S., Krawetz, R. J., & Duncan, N. A. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23749 · Cited by 8
“The Young’s moduli of individual bony elements were assigned based on the micro-CT gray-scale values and the material properties (Table 1) were obtained as previously described.(19,20) An axial compressive load was applied to the tibial plateau of both intact and fractured models.”
MethodReeves, J. M., Athwal, G. S., Johnson, J. A., & Langohr, G. D. G. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4042172 · Cited by 8
Shore, S. W., Unnikrishnan, G. U., Hussein, A. I., & Morgan, E. F. (2012) · CRC Press eBooks · doi:10.1201/b13733-3 · Cited by 8
Orias, E., & Andres, A. (2005) · Cited by 8
Sanada, J. T. (2007) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.25.2007.tde-19062007-133051 · Cited by 8
Analyses of trabecular bone failure
Verhulp, E. E. (2006) · TU/e Research Portal · doi:10.6100/ir608109 · Cited by 8
“ratio of 0.3 and an isotropic Young’s modulus of 15 GPa for trabecular and 22.5 GPa for cortical bone (Rho et al., 1993; Turner et al., 1999).”
BackgroundMethodInfluentialOptimized design of porous dental implant structures based on triply periodic minimal surface (TPMS)
Chen, S., Liu, X., Liao, C., Chen, X., Lai, H., & Lv, J. (2025) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2025-0159 · Cited by 7
Qiao, S., Luo, T., Pan, M., Liu, J., Yang, H., Hu, X., & Qian, Z. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102607 · Cited by 7
Shen, H., Song, C., & Yang, L. (2025) · International Journal of Mechanics and Materials in Design · doi:10.1007/s10999-025-09833-w · Cited by 7
“…parameters (unit cell size L and porosity φ) that enable the scaffold’s elastic modulus ( E ) and permeability ( K ) to simultaneously approach the target values of natural trabecular bone (elastic modulus: E 0 = 1.8 GPa; permeability: K 0 = 10 × 10 −9 m 2 ) (Nauman et al. 1999; Rho et al. 1993).”
InfluentialShah, I., Schlauch, A. M., Phan, L., Han, J., Raji, O. R., & Farrell, B. (2024) · Orthopaedics & Traumatology Surgery & Research · doi:10.1016/j.otsr.2024.103868 · Cited by 7
Kuznik, I., Kruppke, I., Pötzsch, H. F., & Cherif, C. (2024) · Journal of Applied Polymer Science · doi:10.1002/app.55457 · Cited by 7
Altorfer, F. C. S., Laux, C. J., Graf, D. N., Götschi, T., Abel, F., Farshad, M., & Spirig, J. M. (2024) · The International Journal of Spine Surgery · doi:10.14444/8610 · Cited by 7
Venkatesh, S., Teeraratkul, C., Rovito, N., Mukherjee, D., & Lynch, M. E. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109637 · Cited by 7
Physical Properties of Single Cells and Collective Behavior
Kubitschke, H., Morawetz, E. W., Käs, J. A., & Schnauß, J. (2017) · Springer eBooks · doi:10.1007/978-3-319-65924-4_5 · Cited by 7
Triply periodic minimal surface porous implants to reconstruct bone defects
Verma, R., Singh, N. K., Kumar, S., & Kumta, S. M. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-817913-0.00004-3 · Cited by 7
Latifi, F., Tabrizi, R., & Kordkheili, M. R. H. (2022) · Journal of Maxillofacial and Oral Surgery · doi:10.1007/s12663-022-01743-0 · Cited by 7
“The corresponding material properties such as modulus of elasticity and Poisons ratio (Table 1) were determined according to the previous studies [10].”
ResultReference velocity of a human head in bone conduction hearing: Finite element study
Lim, J., Dobrev, I., & Kim, N. (2023) · Hearing Research · doi:10.1016/j.heares.2023.108699 · Cited by 7
Latifi, F., Tabrizi, R., Kordkheili, M. R. H., Shahbazi, S., & Fernandes, G. V. O. (2024) · Journal of Maxillofacial and Oral Surgery · doi:10.1007/s12663-024-02162-z · Cited by 7
Blöß, T., & Welsch, M. (2014) · Lecture notes in applied and computational mechanics · doi:10.1007/978-3-319-10981-7_1 · Cited by 7
Deducing a mechanism of all musculoskeletal injuries
Verrall, G. M., & Dolman, B. (2016) · Muscles Ligaments and Tendons Journal · doi:10.32098/mltj.02.2016.02 · Cited by 7
NUMERICAL AND MECHANICAL ANALYSES OF A 3D-PRINTED TITANIUM TRABECULAR DENTAL IMPLANT
Řehounek, L., & Jíra, A. (2017) · Acta Polytechnica · doi:10.14311/ap.2017.57.0218 · Cited by 7
Kim, H. N., Mandal, S., Basu, B., & Kalidindi, S. R. (2019) · Integrating materials and manufacturing innovation · doi:10.1007/s40192-019-00141-8 · Cited by 7
SINTERING AND CHARACTERIZATION OF NEW FORSTERITE CERAMICS
GOREA, M., Naghiu, M., Avram, A., Petean, I., & Tomoaia-Cotişel, M. (2019) · Studia Universitatis Babeș-Bolyai Chemia · doi:10.24193/subbchem.2019.2.32 · Cited by 7
Effects of Unit Cell Size on the Mechanical Performance of Additive Manufactured Lattice Structures
Soltani-Tehrani, A., Lee, S.-J., Sereshk, M. R. V., & Shamsaei, N. (2019) · doi:10.26153/tsw/17477 · Cited by 7
Ursino, H. L., James, B. D., Ludtka, C., & Allen, J. B. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-820508-2.00018-0 · Cited by 7
Cates, N. K., Miller, J. D., Chen, S. S., Ayyagari, V. M., O’Hara, N. N., Lamm, B. M., & Wynes, J. (2021) · The Journal of Foot & Ankle Surgery · doi:10.1053/j.jfas.2021.12.021 · Cited by 7
Multiscale Modeling of Elastic Properties of Trabecular Bone
Hamed, E., Lee, Y., & Jasiuk, I. (2010) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-642-14515-5_213 · Cited by 7
Plastic behaviour of microstructural constituents of cortical bone tissue: a nanoindentation study
Abdelwahab, A. A., & Silberschmidt, V. V. (2013) · International Journal of Experimental and Computational Biomechanics · doi:10.1504/ijecb.2013.056521 · Cited by 7
“Other methods were also used to measure bone’s microscopic properties: microhardenss, microtesting, in-vivo microindentation and ultrasonic techniques (Weaver, 1966; Rho, 1993; Ko et al., 1995; Shieh et al., 1995; Diez-Perez et al., 2010).”
MethodImpact of partial-thickness tears on supraspinatus tendon strain based on a finite element analysis
Engelhardt, C., Farron, A., Becce, F., Pioletti, D. P., & Terrier, A. (2014) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2014.931514 · Cited by 7
“The humeral head was assumed isotropic and linear elastic ( E ¼ 10.4 GPa, v ¼ 0.3) (Rho et al. 1993).”
BackgroundInfluentialEffects of Condylar Elastic Properties to Temporomandibular Joint Stress
Zhang, M., Ono, T., Chen, Y., Lv, X., Wu, S., Song, H., Zhao, R., & Wang, Y. (2009) · BioMed Research International · doi:10.1155/2009/509848 · Cited by 7
“Comparatively, ultrasonic techniques offer advantages over mechanical techniques [20, 21].”
MethodSong, Y., Wang, S., Chan, M. F., Burman, C., Dhawan, A. P., & Song, Y. (2006) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2006.260160 · Cited by 7
Toyoshima, Y., & Wakabayashi, N. (2015) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.3653 · Cited by 7
Modeling the Thorax for Impact Scenarios
Yang, K. H., & Presley, B. R. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-809831-8.00014-3 · Cited by 7
Stress Analysis of an Overlay Denture and a Magnetic Attachment using Finite Element Method.
Nakamura, Y. (1998) · Nihon Hotetsu Shika Gakkai Zasshi · doi:10.2186/jjps.42.234 · Cited by 7
Quantitative Ultrasound for Assessing Bone Properties
Hans, D., Fuerst, T. P., Guglielmi, G., & Genant, H. K. (1998) · Springer eBooks · doi:10.1007/978-3-642-80440-3_19 · Cited by 7
Mechanical testing and modelling of a bone-implant construct
Grant, C. A. (2012) · Cited by 7
Payne, T. F. (2015) · Loughborough University Institutional Repository (Loughborough University) · Cited by 7
Barkaoui, A. (2012) · theses.fr (ABES) · doi:10.70675/03625c86z58daz485dz9b5dzf1da050608ab · Cited by 7
Biomedical Applications of the Fused Filament Fabrication (FFF) Technology
Buj-Corral, I., Herranz-Diez, C., Tejo‐Otero, A., & Otero, J. (2023) · Springer eBooks · doi:10.1007/978-981-99-2119-5_28 · Cited by 6
Deshmukh, S. R., Chand, A., & Ghorpade, R. R. (2024) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ad8202 · Cited by 6
Rubio, J. E., Tong, J., Sundaramurthy, A., Pant, A., Nagaraja, S., Owen, M. K., Samaan, M. A., Noehren, B. W., & Reifman, J. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1654585 · Cited by 6
Szarek, P., & Ruberti, J. W. (2026) · Sub-cellular biochemistry/Subcellular biochemistry · doi:10.1007/978-3-032-05273-5_10 · Cited by 6
Biofunctional Testing of a Degradable Implant Made by Mg-Nd and Mg-Zn Alloys Used for Bone Defects
Mănescu, V., Antoniac, A., Păltânea, G., Antoniac, I., Páll, E., Moraru, M.-C., Dreancă, A., Sevastre, B., Ștefănoiu, R., Ciocoiu, R. C., et al. (2026) · Biomimetics · doi:10.3390/biomimetics11030169 · Cited by 6
“It can be concluded that the implant samples are characterized by compressive strength values that are much closer to those of human bone (205 MPa along the longitudinal axis and 131 MPa in the transverse axis [83]), demonstrating that the proposed design is suitable for use as a bone substitute.”
InfluentialEngineering anisotropic tissues: from structured scaffolds to magnetic actuation
Demri, N., Descroix, S., & Wilhelm, C. (2026) · Materials Today Bio · doi:10.1016/j.mtbio.2026.103191 · Cited by 7
“Cortical bone is composed of a succession of compact concentric layers forming an outer protecting sheath, with an elastic modulus of about 20 GPa [109].”
Minghinelli, F. E., Márquez, Y. B., Pipolo, D. O., Recalde, R. J., Mantese, B. E., & Rugilo, C. (2023) · Surgical Neurology International · doi:10.25259/sni_211_2023 · Cited by 6
“[19] As part of the study, Young’s modulus (described by Rho et al.[17]) was also measured in bone tissue.”
MethodStrength stability over loading time of zirconia-hydroxyapatite composites
Komarek, S., Wojteczko, A., Pędzich, Z., Haberko, K., Kwaśniewski, P., & Ziąbka, M. (2023) · Materials Today Communications · doi:10.1016/j.mtcomm.2023.106963 · Cited by 6
Ha, C., Choi, I., Lee, J.-K., Oh, J., Ahn, W., & Han, S.-H. (2024) · Clinics in Orthopedic Surgery · doi:10.4055/cios23376 · Cited by 6
Wearing, S. C., Hooper, S., Langton, C. M., Keiner, M., Horstmann, T., Crevier‐Denoix, N., & Pourcelot, P. (2024) · Healthcare · doi:10.3390/healthcare12131254 · Cited by 6
Shankar, A., & Bhatt, N. K. (2024) · Journal of Applied Physics · doi:10.1063/5.0213686 · Cited by 6
Determination of elastic moduli of polymeric materials using microhardness indentation
Titus, R., Satpathy, M., Mecholsky, J. J., Jodha, K. S., Abdulhameed, N. F., & Griggs, J. A. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106713 · Cited by 6
Dunne, R. A., Dickel, D., Green, A., Kim, D. Y., Priddy, L. B., & Priddy, M. W. (2024) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.35519 · Cited by 6
Gong, H., Fan, Y., Zhang, M., & Qin, L. (2008) · Acta Mechanica Sinica · doi:10.1007/s10409-008-0198-2 · Cited by 6
Mechanical Characterization of Hydrogels and its Implications for Cellular Activities
Wilson, S. L., Ahearne, M., Haj, A. J. E., & Yang, Y. (2014) · Royal Society of Chemistry eBooks · doi:10.1039/9781782622055-00171 · Cited by 6
A new finite element with variable Young's modulus
Mazur, K., Krawczuk, M., & Dąbrowski, L. (2023) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.3712 · Cited by 6
“96).(3) Treating bone as an isotropic material allows to build simple, small FEM models where the main source of the volume of the calculation file is meshing size.”
BackgroundFinite Element Stress Analysis of Keyhole Plate System in Sagittal Split Ramus Osteotomy
Kim, J.-W., Park, K.-N., Lee, C.-H., Kim, Y.-S., Kim, Y., & Yang, B. (2018) · Scientific Reports · doi:10.1038/s41598-018-27186-7 · Cited by 6
Солдатенко, А. С., Karachevtseva, M. A., Sheremetyev, V., Kudryashova, A. A., Arkhipova, A. Y., Andreev, V. A., Дмитриевич, П. С., Braïlovski, V., Moisenovich, M. M., & Шайтан, К. В. (2019) · Moscow University Biological Sciences Bulletin · doi:10.3103/s0096392519040126 · Cited by 6
Polieter eter keton (peek) diş hekimliğinde yükselen materyal
Ozden, S., & Demir, H. (2020) · Necmettin Erbakan Universitesi Dis Hekimligi Dergisi (NEU Dent J) Necmettin Erbakan · Cited by 6
Spitznagel, F. A., Bonfante, E. A., Campos, T. M. B., Vollmer, M. A., Boldt, J., Doerken, S., & Gierthmuehlen, P. C. (2021) · Materials · doi:10.3390/ma14247539 · Cited by 6
An in silico model for woven bone adaptation to heavy loading conditions in murine tibia
Goyal, A. K., & Prasad, J. (2022) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-022-01599-w · Cited by 6
“(2) and (3), where E (= 17GPa) denotes Young’s Modulus of bone (Rho et al. 1993).”
BackgroundEskibağlar, M., Erdem, S., & Kaman, M. O. (2023) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2023.2254882 · Cited by 6
Koga, M., Kim, B., Lintz, M., Kırnaz, S., Goldberg, J. L., Hussain, I., Medary, B., Meyers, K. N., Maher, S. A., Härtl, R., et al. (2023) · JOR Spine · doi:10.1002/jsp2.1307 · Cited by 6
Allen, M. R., & Wallace, J. M. (2025) · Springer eBooks · doi:10.1007/978-3-031-90609-1_5 · Cited by 6
Hierarchically Nanostructured Biological Materials
Seto, J., Rao, A., & Cölfen, H. (2014) · Wiley eBooks · doi:10.1002/9783527664948.ch2 · Cited by 6
[Toward an anthropometric diagnosis of osteopenia and a biochemical diagnosis of osteoporoses].
Cointry, G. R., Capozza, R. F., Ferretti, J. L., & Frost, H. M. (2003) · PubMed · Cited by 6
Mustafa, A. A., Matinlinna, J. P., Saidin, S., & Kadir, M. R. A. (2014) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2014.05.011 · Cited by 6
Suzuki, N., Umeda, T., Sumi, T., Horikoshi, S., KUWAHARA, H., Toyama, T., Musha, Y., & Itatani, K. (2015) · Journal of the Ceramic Society of Japan · doi:10.2109/jcersj2.15209 · Cited by 6
A Viscoelastic Study of Poly(ε-Caprolactone) Microsphere Sintered Bone Tissue Engineering Scaffold
Shahin‐Shamsabadi, A., Hashemi, A., & Tahriri, M. (2017) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-017-0325-2 · Cited by 6
“Figure 7 compares elastic [47, 48] and viscoelastic properties of compact [49] and trabecular [50] bone”
BackgroundMechanics of osteoporotic trabecular bone
Bérot, M., Aurégan, J.-C., Imbert, L., Magoariec, H., Budyn, É., Zadegan, F., Hannouche, D., Bensidhoum, M., & Hoc, T. (2012) · Mechanics & Industry · doi:10.1051/meca/2012023 · Cited by 6
1.1 Metals for Use in Medicine
Andersen, P. J. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100691-7.00247-0 · Cited by 6
Păcurar, R., Păcurar, A., & Petrilak, A. (2017) · MATEC Web of Conferences · doi:10.1051/matecconf/201711203009 · Cited by 6
Nanowires for biomedical applications
Sun, T., & Tsang, W. M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100716-7.00004-0 · Cited by 6
Chan, H. Y., & Walker, P. S. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.05.014 · Cited by 6
Hwang, S., Lim, S. H., & Han, S. (2018) · Applied Surface Science · doi:10.1016/j.apsusc.2018.12.080 · Cited by 6
Ultra-fine grained β-type TNZT ELI alloy with high strength and low elastic modulus
Polyakov, A. V., Semenova, I. P., Ivanov, E., & Valiev, R. Z. (2018) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/461/1/012077 · Cited by 6
Zubaidi, S. H. A., Al-Sultan, M., & Hasan, L. A. (2021) · Journal of Oral Biology and Craniofacial Research · doi:10.1016/j.jobcr.2021.05.004 · Cited by 6
Kahla, R. B., & Barkaoui, A. (2021) · Elsevier eBooks · doi:10.1016/b978-0-323-88467-9.00005-9 · Cited by 6
Samelin, N., Koller, W., Ascherl, R., & Gradinger, R. (1996) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmte.1996.41.7-8.203 · Cited by 6
New method to determine the Young’s modulus of single trabeculae
Lorenzetti, S. (2006) · Repository for Publications and Research Data (ETH Zurich) · doi:10.3929/ethz-a-005339099 · Cited by 6
Development of a novel endoprosthesis for canine limb-sparing using a finite element approach
Shetye, S. S., Puttlitz, C. M., James, S. P., Santoni, B. G., & Heyliger, P. R. (2007) · Digital Collections of Colorado (Colorado State University) · doi:10.25675/3.019175 · Cited by 6
Methods for Evaluating the Performance and Human Stress-Factors of Percussive Riveting
Ahn, J. (2017) · ResearchWorks at the University of Washington (University of Washington) · Cited by 6
Experimental and computational micromechanics of mineralized tendon and bone
Spiesz, E. M. (2011) · reposiTUm (TU Wien) · Cited by 6
Fatigue Resistance of Customized Implant-Supported Restorations
Lenz, U., dos Santos, R. B., Satpathy, M., Griggs, J. A., & Bona, Á. D. (2025) · Materials · doi:10.3390/ma18143420 · Cited by 5
Magnesium-substituted zinc-calcium hydroxyfluorapatite bioceramics for bone tissue engineering
Ali, R. H., Sghaier, Z., Ageorges, H., Salem, E. B., & Hidouri, M. (2025) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2025.106933 · Cited by 5
Cuevas, A., Aguilar, C. E., Medina, A., Béjar, L., & Oseguera, J. (2019) · Materials Today Proceedings · doi:10.1016/j.matpr.2019.03.165 · Cited by 5
Evaluation of Heat Transfer on Bone Cemented Hip Replacement
Chukwuneke, J. L., Ikekwem, J. U., Okokpujie, I. P., & Ongbali, S. O. (2019) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1378/2/022035 · Cited by 5
PEEK Biomaterial Use for Chairside CAD/CAM Dental Restorations: Bridging the Gap to Future
Abdulsamee, N. (2021) · Open Access Journal of Dental Sciences · doi:10.23880/oajds-16000297 · Cited by 5
Sonlu Elemanlar Stres Analizi ve Endodontide Kullanımı
Akbaş, M., Akbulut, M. B., & Belli, S. (2021) · European Journal of Research in Dentistry · doi:10.29228/erd.15 · Cited by 5
Tensile Response Characterization and Constitutive Modeling of LPBF Ti6Al4V Thin Struts
Hosseini, E., Robmann, S., Lüthi, T., Affolter, C., & Mazza, E. (2022) · Advanced Engineering Materials · doi:10.1002/adem.202201135 · Cited by 5
Spitznagel, F. A., Hoppe, J. S., Bonfante, E. A., Campos, T. M. B., Langner, R., & Gierthmuehlen, P. C. (2022) · Materials · doi:10.3390/ma15238465 · Cited by 5
“All zirconia implants were perpendicularly embedded in epoxy resin (RenCast® CW20/ Ren® HY 49, Huntsman Advanced Materials, Salt Lake City, UT, USA) [30,31].”
MethodA Case for Material Stiffness as a Design Parameter in Encapsulated Islet Transplantation
Johnson, C. D., Aranda‐Espinoza, H., & Fisher, J. P. (2023) · Tissue Engineering Part B Reviews · doi:10.1089/ten.teb.2022.0157 · Cited by 5
“105,106 Also, organ stiffnesses relevant to macrophages and EIT including the bone marrow, 107 thymus, 108 liver, 88,89 pancreas, 109,110 kidney, 90 and subcutaneous cavity (hypodermis).”
Developing clinical grade flexible implantable electronics
Liu, Y., Balsamo, D., & Degenaar, P. A. (2023) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aca779 · Cited by 5
Kerberger, R., Brunello, G., Drescher, D., van Rietbergen, B., & Becker, K. (2023) · Bone · doi:10.1016/j.bone.2023.116912 · Cited by 5
CN− and NH2− co-decorated graphdiynes: A theoretical investigation
Yu, G., Jia, R., & Chen, W. (2023) · Diamond and Related Materials · doi:10.1016/j.diamond.2023.110409 · Cited by 5
Pre-clinical characterization of a novel flexible surface stem design for total knee replacements
Saß, J., Hembus, J., Fuhrmann, E., Vogel, D., Bauer, E., Link, H. D., & Bader, R. (2023) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/09544119231197596 · Cited by 5
“The mismatch between Young’s moduli of the bone tissue (cortical bone: 18.6 GPa, 33 cancellous bone: 0.2–4.5 GPa 34 ) and implant materials (Ti6Al4V: ; 114 GPa 35 ) is leading to decreased loading of the adjacent bone and consequently to bone resorption.”
BackgroundInfluentialLenz, U., dos Santos, R. B., Griggs, J. A., Estrela, C., Bueno, M. R., Porto, O. C. L., & Bona, Á. D. (2024) · Dental Materials · doi:10.1016/j.dental.2024.06.003 · Cited by 5
Electrochemically Active Materials for Tissue-Interfaced Soft Biochemical Sensing
Qian, X., Chen, Z., Zhang, F., & Yan, Z. (2025) · ACS Sensors · doi:10.1021/acssensors.5c00029 · Cited by 5
PERFORMANCE OF EXISTING BONE STAPLES FOR TREATMENT OFFRACTURES
Salameh, T. M. (2020) · EngagedScholarship @ Cleveland State University (Cleveland State University) · Cited by 5
Evolution of Phase Strains During Tensile Loading of Bovine Cortical Bone
Singhal, A., Fang, Y., Stock, S. R., Almer, J., Brinson, L. C., & Dunand, D. C. (2012) · Advanced Engineering Materials · doi:10.1002/adem.201200204 · Cited by 5
The Effect of Age on Material Properties
Allen, M. R., Burr, D. B., & Turner, C. H. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-374602-3.00018-3 · Cited by 5
Self-citationMicroscale Machining and Mechanical Characterization of Bone Tissue
Altman, K. J. (2009) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 5
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.