Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 501–600 of 1,000
Tsouknidas, A., Lympoudi, E., Michalakis, K. X., Giannopoulos, D., Michailidis, N., Pissiotis, A. L., Fytanidis, D. K., & Kugiumtzis, D. (2015) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.3814 · Cited by 25
Hemodynamic effect of progressive right atrial dilatation in atriopulmonary connections
Lardo, A. C., del Nido, P. J., Webber, S. A., Friehs, I., & Cape, E. G. (1997) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70110-7 · Cited by 25
Tensile trabeculae--myth or reality?
Sverdlova, N. S. (2011) · PubMed · Cited by 24
A new multiscale micromechanical model of vertebral trabecular bones
Haj-Ali, R. M., Massarwa, E., Aboudi, J., Galbusera, F., Wolfram, U., & Wilke, H. (2016) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-016-0862-6 · Cited by 24
Study on the mechanism of ultrasonic treatment impact on the dough's fermentation capability
Zhang, Y., Wang, B., Wang, W., Wang, H., Liu, X., & Zhang, H. (2021) · Journal of Cereal Science · doi:10.1016/j.jcs.2021.103191 · Cited by 24
Ribeiro, J. P. L. D., Domingues, R. M. A., Babo, P. S., Nogueira, L. P., Reseland, J. E., Reis, R. L., Gómez‐Florit, M., & Gomes, M. E. (2022) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2022.119638 · Cited by 24
Spitznagel, F. A., Prott, L. S., Hoppe, J. S., Manitckaia, T., Blatz, M. B., Zhang, Y., Langner, R., & Gierthmuehlen, P. C. (2023) · Journal of Esthetic and Restorative Dentistry · doi:10.1111/jerd.13169 · Cited by 24
McNamara, L. M. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.10127-4 · Cited by 25
Wang, Y., Chen, X., Zhang, C., Feng, W., Zhang, P., Yang, C., Huang, J., Luo, Y., & Chen, J. (2018) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411918816114 · Cited by 24
Pereira, B. L., Beilner, G., Lepienski, C. M., Szameitat, E. S., Chee, B. S., Kuromoto, N. K., Santos, L. L., Mazzaro, I., Claro, A. P. R. A., & Nugent, M. (2019) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2019.125224 · Cited by 24
Reisinger, A., Frank, M., Thurner, P. J., & Pahr, D. H. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01329-0 · Cited by 25
Reverse shoulder arthroplasty glenoid lateralization influences scapular spine strains
Kerrigan, A., Reeves, J., Langohr, G. D. G., Johnson, J. A., & Athwal, G. S. (2020) · Shoulder & Elbow · doi:10.1177/1758573220935567 · Cited by 24
“Interestingly, this is very close to approaching the traumatic fracture yield of cortical bone reported in the literature of 120–130 MPa.35,36 Of note, the highest values for scapular spine stress in this study were reached with the arm in forward elevation, with values as high as 28.7 MPa.”
BackgroundInfluentialGaining Insight into the Deformation of Achilles Tendon Entheses in Mice
Sartori, J., Köhring, S., Bruns, S., Moosmann, J. P., & Hammel, J. U. (2021) · Advanced Engineering Materials · doi:10.1002/adem.202100085 · Cited by 24
Non-linear mechanical properties and dynamic response of silicon nitride bioceramic
Du, X., Blugan, G., Künniger, T., Lee, S. S., Vladislavova, L., & Ferguson, S. J. (2021) · Ceramics International · doi:10.1016/j.ceramint.2021.08.261 · Cited by 24
Slanted and cluttered: Solving deficiencies in SLM-manufactured lattice geometries
Kostadinov, A., Yan, L., Teo, A. Q. A., & O’Neill, G. K. (2021) · Materials & Design · doi:10.1016/j.matdes.2021.110130 · Cited by 24
Savadi, R. C., Agarwal, J., Agarwal, R. S., & Rangarajan, V. (2011) · The Journal of Indian Prosthodontic Society · doi:10.1007/s13191-011-0105-6 · Cited by 24
Klika, V., & Maršík, F. (2010) · PubMed · Cited by 23
Bioactive and fatigue-resistant Ti–Ta alloy by additive manufacturing for orthopedic applications
Liu, Q., Zhang, Y., Chen, W., He, P., Tian, Y., Liu, Y., Dou, Y., Bian, H., Yang, J., Yang, Q., et al. (2025) · Smart Materials in Manufacturing · doi:10.1016/j.smmf.2025.100086 · Cited by 23
Engelhardt, C., Ingram, D., Müllhaupt, P., Farron, A., Becce, F., Pioletti, D. P., & Terrier, A. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1075012 · Cited by 23
“The Young’s Modulus was set to 10.4 GPa and Poisson’s ratio to 0.3 (Rho et al. 1993).”
MethodInfluentialRehman, M., Wang, Y., Ishfaq, K., Mushtaq, R. T., Kumar, M. S., & Yang, H. (2023) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2023.04.030 · Cited by 23
Zhang, Y., Yang, J., Wan, W., Zhao, Q., Di, M., Zhang, D., Liu, G., Chen, C., Sun, X., Zhang, W., et al. (2025) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2024.10.010 · Cited by 23
Li, T., Yang, X., Zhang, D., Zhou, H. Y., Shao, J., Ding, Y., & Kong, L. (2012) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2011.08.010 · Cited by 23
In Vitro Study of CaTiO3–Hydroxyapatite Composites for Bone Tissue Engineering
Linh, N. T. B., Mondal, D., & Lee, B. (2014) · ASAIO Journal · doi:10.1097/mat.0000000000000126 · Cited by 23
Applications of PEEK in the Dental Field
Siewert, B., Plaza-Castro, M., Sereno, N. M., & Jarman-Smith, M. L. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-812524-3.00020-x · Cited by 23
Composite biomaterials for bone repair
Santis, R. D., Guarino, V., & Ambrosio, L. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102451-5.00010-x · Cited by 23
Polyetheretherketone (PEEK) Dental Implants: A Case for Immediate Loading
Marya, K., Dua, J., Chawla, S., Sonoo, P. R., Aggarwal, A., & Singh, V. (2011) · International Journal of Oral Implantology and Clinical Research · doi:10.5005/jp-journals-10012-1043 · Cited by 23
High strain rate response of rabbit femur bones
Shunmugasamy, V. C., Gupta, N., & Coelho, P. G. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.06.034 · Cited by 23
“The average epiphyseal and diaphyseal bone densities were found to be 16227284 and 20487454 kg/m, respectively, which are in line with previously published data (Katsamanis and Raftopoulos, 1990; Rho et al., 1993).”
ResultUltrasound and the biomechanical competence of bone
Nicholson, P. (2008) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2008.830 · Cited by 23
“Rho and colleagues [23] measured the elastic modulus of cortical bone microspecimens with ultrasonic and microtensile testing and found good correlation, but differences in magnitude.”
Müller, R., Kampschulte, M., Khassawna, T. E., Schlewitz, G., Hürter, B., Böcker, W., Bobeth, M., Langheinrich, A. C., Heiß, C., Deutsch, A., et al. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1140-3 · Cited by 23
“8 gPa (ultrasonic measurements, [23]), and 17 gPa (combination of FE analysis and compression test, [17]).”
BackgroundMallmann, F., Rosa, L., Borba, M., & Bona, Á. D. (2017) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2017.01.016 · Cited by 23
“4 mm in diameter and 20-mm height) were obtained by cutting a rod of continuous glass woven fabric impregnated with epoxy resin (G10NEMA Grade G-10; Accurate Plastics, Inc) having elastic moduli of 15 GPa (crosswise) and 19 GPa (lengthwise), which are comparable to human bone moduli, which vary from 10 to 15 GPa (trab…”
BackgroundMethodCharge-induced electromechanical actuation of Mo- and W-dichalcogenide monolayers
Thanh, V. V., Hung, N. T., & Truong, D. V. (2018) · RSC Advances · doi:10.1039/c8ra08248k · Cited by 23
Pauwels, F. E. T., McClure, S. R., Amin, V. R., Sickle, D. V., & Evans, R. B. (2004) · American Journal of Veterinary Research · doi:10.2460/ajvr.2004.65.207 · Cited by 23
“25 MHz, the wavelength in cortical bone is approximately 1 mm, which satisfies that condition.(12) Ultrasonic scatter can increase the variation of measurements.”
BackgroundBone Health and Physical Activity - The Complex Mechanism
Nowak, A., & Ogurkowska, M. B. (2024) · Aging and Disease · doi:10.14336/ad.2024.1316 · Cited by 23
“It should further be noted that lower stress levels, below the yield point, in the elastic part of spongy bone allow the applied stress to be elastically stored and transmitted, thereby avoiding tissue micro-damage [32, 33].”
Bizari, D., Moztarzadeh, F., Rabiee, M., Tahriri, M., Banafatizadeh, F., Ansari, A., & Khoshroo, K. (2011) · Advances in Applied Ceramics Structural Functional and Bioceramics · doi:10.1179/1743676111y.0000000052 · Cited by 22
Boosting bone regeneration using augmented melt-extruded additive-manufactured scaffolds
Cámara-Torres, M., Fucile, P., Sinha, R., Mota, C., & Moroni, L. (2023) · International Materials Reviews · doi:10.1080/09506608.2022.2153219 · Cited by 23
Biocompatible optical fiber for photomedical application
Guo, Y., Zheng, J., Wang, Z., Chen, G., Hou, K., & Zhu, M. (2023) · Giant · doi:10.1016/j.giant.2023.100195 · Cited by 22
Differences in running biomechanics between young, healthy men and women carrying external loads
Rubio, J. E., Tong, J., Sundaramurthy, A., Subramani, A. V., Kote, V. B., Baggaley, M., Edwards, W. B., & Reifman, J. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1250937 · Cited by 22
“Based on the Young’s modulus, we classified each element as either intramedullary tissue ( E 6 MPa), trabecular bone (6 MPa ≤ E 8 GPa), or cortical bone ( E ≥ 8 GPa) (Rho et al., 1993).”
Composite biomaterials for bone repair
Santis, R. D., Guarino, V., & Ambrosio, L. (2009) · Elsevier eBooks · doi:10.1533/9781845696610.2.252 · Cited by 22
Comparison of mechanical and ultrasound elastic modulus of ovine tibial cortical bone
Grant, C. A., Wilson, L. J., Langton, C. M., & Epari, D. R. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.03.012 · Cited by 22
Jomjunyong, K., Rungsiyakull, P., Rungsiyakull, C., Aunmeungtong, W., Chantaramungkorn, M., & Khongkhunthian, P. (2017) · Oral & Implantology · doi:10.11138/orl/2017.10.4.369 · Cited by 22
Solanke, S., Gaval, V. R., & Sanghavi, S. A. (2020) · Materials Today Proceedings · doi:10.1016/j.matpr.2020.10.528 · Cited by 22
Fiber Formation of Printed Carbon Fiber/Poly (Ether Ether Ketone) with Different Nozzle Shapes
Matschinski, A., Ziegler, P., Abstreiter, T., Wolf, T., & Drechsler, K. (2021) · Polymer International · doi:10.1002/pi.6196 · Cited by 22
Experimental analysis of wear and multi-shape burr loading during neurosurgical bone grinding
Babbar, A., Jain, V., Gupta, D., Agrawal, D. K., Prakash, C., Singh, S., Wu, L., Zheng, H. Y., Królczyk, G., & Bogdan-Chudy, M. (2021) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2021.02.060 · Cited by 22
A biological nanofoam: The wall of coniferous bisaccate pollen
Cojocaru, R., Mannix, O., Capron, M., Miller, C. G., Jouneau, P., Gallet, B., Falconet, D., Pacureanu, A. T. J., & Stukins, S. (2022) · Science Advances · doi:10.1126/sciadv.abd0892 · Cited by 22
Stress Distribution on Various Implant-Retained Bar Overdentures
Kümbüloğlu, Ö., Koyuncu, B., Yerlioğlu, G., Husain, N. A., & Özcan, M. (2022) · Materials · doi:10.3390/ma15093248 · Cited by 22
A new device and method for measuring the elastic modulus of single trabeculae
Lorenzetti, S., Carretta, R., Müller, R., & Stüssi, E. (2011) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.03.012 · Cited by 22
“[7] Rho JY, Ashman RB, Turner CH.”
BackgroundInfluentialBoonyawan, D., Waruriya, P., & Suttiat, K. (2016) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2016.05.063 · Cited by 22
Resin-free three-layered Ti/PMMA/Ti sandwich materials: Adhesion and formability study
Reggente, M., Harhash, M. M., Kriegel, S., He, W., Masson, P., Faerber, J., Pourroy, G., Palkowski, H., & Carradò, A. (2019) · Composite Structures · doi:10.1016/j.compstruct.2019.03.039 · Cited by 22
Biomechanical aspects of bone repair
Lacroix, D. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102451-5.00003-2 · Cited by 22
Image-Based Finite Element Analysis
Boyd, S. K. (2008) · Springer eBooks · doi:10.1007/978-3-540-68993-5_14 · Cited by 22
“1999), or a combination of tensile testing and acoustic microscopy (Rho et al. 1993).”
BackgroundLipowiecki, M., & Brabazon, D. (2009) · Advanced materials research · doi:10.4028/www.scientific.net/amr.83-86.914 · Cited by 22
Multiplanar variations in the structural characteristics of cancellous bone
Zhu, M., Keller, T. S., Moeljanto, E., & Spengler, D. M. (1994) · Bone · doi:10.1016/8756-3282(94)90286-0 · Cited by 22
ASHMAN, R. B., Antich, P. P., Gonzales, J., Anderson, J. A., & Rho, J. Y. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90061-2 · Cited by 22
Self-citationContact evolution of dry and hydrated fingertips at initial touch
Serhat, G., Vardar, Y., & Kuchenbecker, K. J. (2022) · PLoS ONE · doi:10.1371/journal.pone.0269722 · Cited by 21
“The elastic modulus of human bone [44] is three orders of magnitude larger than that of the fingernail, which is the stiffest of the five deformable materials in the finger cross-section.”
BackgroundDesigning Regenerative Bioadhesives for Tissue Repair and Regeneration
Li, X., Liu, Y., Liu, S., Li‐Jessen, N. Y. K., Haglund, L., Huang, B., & Li, J. (2023) · Advanced Therapeutics · doi:10.1002/adtp.202300139 · Cited by 21
Basaruddin, K. S., TAKANO, N., & Nakano, T. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.785537 · Cited by 21
“Young’s modulus of bone tissue E 0 was set as 10GPa (Rho et al. 1993) and 0.”
MethodInfluentialChen, M., Hu, Y., Hou, Y., Li, M., Chen, M., Tan, L., Mu, C., Tao, B., Luo, Z. Y., & Cai, K. (2020) · Journal of Materials Chemistry B · doi:10.1039/d0tb01412e · Cited by 21
Fabrication of hydrophobic surfaces on Titanium using Micro-EDM exhibiting antibacterial properties
Das, A., Ambastha, S., Priyadarshni, N., Samanta, S. K., & Nagahanumaiah, N. (2021) · Proceedings of the Institution of Mechanical Engineers Part B Journal of Engineering Manufacture · doi:10.1177/09544054211060981 · Cited by 21
“Mechanical properties of some biomaterials.(40)”
Novel and Simple Alternative to Create Nanofibrillar Matrices of Interest for Tissue Engineering
Sohier, J., Corre, P., Perret, C., Pilet, P., & Weiss, P. (2013) · Tissue Engineering Part C Methods · doi:10.1089/ten.tec.2013.0147 · Cited by 21
Mechanical Properties of Human Mineralized Connective Tissues
Santis, R. D., Ambrosio, L., Mollica, F., Netti, P. A., & Nicolais, L. (2007) · Birkhäuser Boston eBooks · doi:10.1007/978-0-8176-4411-6_6 · Cited by 21
Evaluation of 3D hybrid microfiber/nanofiber scaffolds for bone tissue engineering
Ostrowska, B., Jaroszewicz, J., Zaczyńska, E., Tomaszewski, W., Święszkowski, W., & Kurzydłowski, K. J. (2014) · Bulletin of the Polish Academy of Sciences Technical Sciences · doi:10.2478/bpasts-2014-0059 · Cited by 21
“However, all of the investigated structures had similar Young’s Modulus to the natural bone [22, 23].”
BackgroundCarrera, I., Gelber, P. E., Chary, G., Gómez-Masdeu, M., Ballester, M. Á. G., Monllau, J. C., & Noailly, J. (2017) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-017-4428-7 · Cited by 21
“As for the bone tissue stiffness, elastic constants were obtained from experimental measurements on cortical bone specimens from 59- to 60-year-old healthy males [10] and on trabecular bone specimens from 50- to 70-year-old male and female donors with no apparent arthritic pathology or osteopenia [7].”
BackgroundMethodWang, M., & Salem, G. J. (2004) · Bone · doi:10.1016/j.bone.2004.01.025 · Cited by 21
“Cortical bone, for example, has a greater stiffness, elastic modulus, and hardness than trabecular bone, whereas trabecular bone is more elastic and has greater energy-storing capacity [12,30].”
BackgroundParylene-Based Strain Sensors for Bone
Yang, G. Y., Johnson, G., Tang, W. C., & Keyak, J. H. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.909923 · Cited by 21
“5 GPa) and trabecular bone tissue (18 GPa) [9], [10].”
BackgroundYuan, K., Zhang, K., Yang, Y., Lin, Y., Zhou, F., Mei, J., Li, H., Wei, J., Yu, Z., Zhao, J., et al. (2022) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2022.06.006 · Cited by 20
“In addition, the Young's modulus of porous tantalum was approximately 3–4 GPa, which was relatively similar to that of cancellous bone (approximately 10.4 GPa) [19] and could avert the stress-shielding effect of traditional metal implants [18,20].”
BackgroundInfluentialEffects of Stature and Load Carriage on the Running Biomechanics of Healthy Men
Tong, J., Subramani, A. V., Kote, V. B., Baggaley, M., Edwards, W. B., & Reifman, J. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3248504 · Cited by 20
“and the remaining elements as intramedullary tissue [33].”
BackgroundKovács, K., Váncsa, S., Agócs, G., Harnos, A., Hegyi, P., Weninger, V., Baross, K., Kovács, B. G., Soós, G., & Kocsis, G. (2023) · JBMR Plus · doi:10.1002/jbm4.10835 · Cited by 22
“The result that macrostructure had the largest impact was consistent with the observation by Rho et al., [63] who explained that the cortical and the trabecular bones did not behave mechanically in the same way.”
ResultLuo, Y., & Kim, J.-H. (2024) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2024.2304709 · Cited by 20
“In elderly individuals, the apparent Young’s modulus of bone tissue at the femoral neck typically ranges from 1.0 GPa to 25.0 GPa (Morgan et al., 2018; Wu et al., 2018; Rho et al., 1993).”
InfluentialA Review on Soft Ionic Touch Point Sensors
Lee, G., Lee, D. H., Im, G., & Lee, Y. (2024) · Energy & environment materials · doi:10.1002/eem2.12794 · Cited by 20
Nanostructure and elastic modulus of single trabecula in bovine cancellous bone
Yamada, S., TADANO, S., & Fukuda, S. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.09.009 · Cited by 20
“Tensile tests (Carretta et al., 2013b, 2013c; McNamara et al., 2006; Hernandez et al., 2005; Bini et al., 2002; Rho et al., 1993) and bending tests (Carretta et al., 2013b, 2013c; Hambli and Thurner, 2013; Lorenzetti et al., 2011; Szabó et al., 2011; Jungmann et al., 2011; Busse et al., 2009; Choi…”
BackgroundInfluentialOkumura, N., Stegaroiu, R., Nishiyama, H., Kurokawa, K., 北村, 絵., Hayashi, T., & Nomura, S. (2010) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2010.07.002 · Cited by 20
“3 Cancellous bone [29,30] 0.”
Experimental evaluation of new concepts in hip arthroplasty
Wik, T. S. (2012) · Acta Orthopaedica · doi:10.3109/17453674.2012.678804 · Cited by 20
Yu, Y., Hu, Y., Zhou, B., Wang, J., & Guo, X.-D. E. (2020) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.4338 · Cited by 20
“Compared with alternative characterization methods of bone tissue mechanics such as single-trabecula buckling, tensile or bending tests,((14,47-52)) microhardnessmeasurements fromnanoindentation testing,((53-58)) and ultrasonic measurements,((14,55,59,60))”
BackgroundMethodTarala, M., Waanders, D., Biemond, J., Hannink, G., Janssen, D. W., Buma, P., & Verdonschot, N. J. J. (2011) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-011-4419-z · Cited by 20
“Both bone and metal were modeled isotropic, with a Young’s modulus of 6.8 GPa [ 22 ] and 105 GPa (provided by the manufacturer) for the bone and the metal structure, respectively.”
MethodInfluentialThree-dimensional finite element analysis of implant-supported crown in fibula bone model
Park, Y., & Kwon, H. (2013) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2013.5.3.326 · Cited by 20
Kuroda, S., Nishii, Y., Okano, S., & Sueishi, K. (2014) · Journal of Orthodontics · doi:10.1179/1465313314y.0000000098 · Cited by 20
“Table 1 (Carter et al., 1978; Rho et al., 1993; Steinemann et al., 1996).”
Studies of crystal orientation and calcium distribution in trabecular bone
Rokita, E., Chevallier, P., Mutsaers, P. H. A., Tabor, Z., & Wróbel, A. (2005) · Nuclear Instruments and Methods in Physics Research Section B Beam Interactions with Materials and Atoms · doi:10.1016/j.nimb.2005.06.089 · Cited by 20
Baker, C., Wagner, K. K., Wagner, P., Officer, D. L., & Mawad, D. (2021) · Advances in Physics X · doi:10.1080/23746149.2021.1899850 · Cited by 19
Çakmak, G., Güven, M. E., Dönmez, M. B., Kahveci, Ç., Schimmel, M., Abou‐Ayash, S., & Yılmaz, B. (2023) · Clinical Oral Implants Research · doi:10.1111/clr.14165 · Cited by 19
Rahman, A., Husain, M. M., & Prasad, N. (2024) · Ceramics International · doi:10.1016/j.ceramint.2024.05.327 · Cited by 19
Jia, T., Guines, D., Gordin, D. M., Leotoing, L., & Gloriant, T. (2024) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2024.106640 · Cited by 19
Gong, H., Zhang, M., & Fan, Y. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004010 · Cited by 19
Fürst, D., Senck, S., Hollensteiner, M., Esterer, B., Augat, P., Eckstein, F., & Schrempf, A. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.03.158 · Cited by 19
Implant Volume Loss, Misfit, Screw Loosening, and Stress In Custom Titanium and Zirconia Abutments
Barbosa, S. A., Bacchi, A., Barão, V. A. R., Silva‐Sousa, Y. T. C., Bruniera, J. F. B., Caldas, R. A., & Consani, R. L. X. (2020) · Brazilian Dental Journal · doi:10.1590/0103-6440202003643 · Cited by 19
Zeng, W., Lewicki, K. A., Chen, Z., & Citters, D. W. V. (2021) · Medicine in Novel Technology and Devices · doi:10.1016/j.medntd.2021.100076 · Cited by 19
Mori, Y., Masahashi, N., & Aizawa, T. (2022) · Materials · doi:10.3390/ma15155116 · Cited by 19
Simpson, D. J. W., Little, J. P., Gray, H. A., Murray, D. W., & Gill, H. S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2008.12.010 · Cited by 19
Characterization of fracture in topology-optimized bioinspired networks
Nguyen, C., Peetz, D., Elbanna, A. E., & Carlson, J. M. (2019) · Physical review. E · doi:10.1103/physreve.100.042402 · Cited by 19
Barth, J. R. H., Garret, J., Geais, L., Bothorel, H., Saffarini, M., & Godenèche, A. (2019) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-019-0178-4 · Cited by 19
Schrock, P., Lüpke, M., Seifert, H., Borchers, L., & Staszyk, C. (2013) · The Veterinary Journal · doi:10.1016/j.tvjl.2013.10.009 · Cited by 19
“, 2000) and the surrounding bones (Rho et al., 1993).”
MethodSatpathy, S., Babu, C. S., Shetty, S., & Raj, B. (2015) · The Journal of Indian Prosthodontic Society · doi:10.4103/0972-4052.165324 · Cited by 19
“[1] The advantages of implant retained prostheses include improved mastication, increased passive tactile sensitivity, better retention compared to the conventional ones.[15] A minimum of two implants in”
BackgroundThe effect of design variations on stresses in total ankle arthroplasty
Galik, K. (2002) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 19
Wear, K. A. (2003) · The Journal of the Acoustical Society of America · doi:10.1121/1.1554692 · Cited by 19
“…1303 1.85 Gong et al., 1964 Bovine cancellous bone 1.93 Lang et al., 1970 Bovine cortical bone 1.96 0.32 Williams, 1992 Bovine cancellous bone 3800 * Rho et al., 1993 Bovine cancellous bone 2898±85 Ashman et al., 1993 Human cancellous bone 2639–2754 1.73–1.80 - Bovine cancellous bone 2501…”
BackgroundInfluential3-D global/local analysis of composite hip prostheses – a model for multiscale structural analysis
Srinivasan, S., de Andrade, J. R., Biggers, S. B., & Latour, R. A. (1999) · Composite Structures · doi:10.1016/s0263-8223(99)00020-3 · Cited by 19
Interactions between titanium surfaces and biological components
Pegueroles, M. (2009) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-93380 · Cited by 19
Strong living scaffolds for load-bearing musculoskeletal tissue regeneration
Chen, N., Wu, M., Williams, R., Yan, J., Zhou, J., Zhu, D., & Ding, Y. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102571 · Cited by 18
“Cortical bone, the dense outer layer of long bones, demonstrates the highest stiffness, with a Young ’ s modulus of approximately 14 – 22 GPa, an ultimate tensile strength (UTS) of 80 – 150 MPa, and a low failure strain of 0.8 – 1.2 % [19 – 22].”
InfluentialA refined Gibson-Ashby model for functionally graded honeycombs with random irregularities
Beigrezaee, M. J., Jalali, S. K., Misseroni, D., & Pugno, N. M. (2026) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2026.111297 · Cited by 18
Humeral short stem varus–valgus alignment affects bone stress
Tavakoli, A., Spangenberg, G. W., Reeves, J. M., Faber, K. J., & Langohr, G. D. G. (2021) · Journal of Orthopaedic Research® · doi:10.1002/jor.25239 · Cited by 18
“3.(11,12) Trabecular bone elements were assigned material properties based on CT attenuation, that varied spatially using a density‐modulus relationship of E ρ = 8920 app 1.”
MethodAcoustic Force Elastography Microscopy
Liu, H., Gaihre, B., Kijanka, P., Lu, L., & Urban, M. W. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3203435 · Cited by 18
“For example, in the human body, brain tissue is soft with a Young’s modulus of 0.2-1 kPa, while bone tissue reaches a wide range of Young’s modulus values of 30 kPa up to 14 GPa [4] depending on the stage of development [5].”
BackgroundInfluentialLavigne, T., Mazier, A., Perney, A., Bordas, S., Hild, F., & Lengiewicz, J. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105490 · Cited by 18
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.