Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 601–700 of 1,000
Constructing anisotropic finite element model of bone from computed tomography (CT)
Kazembakhshi, S., & Luo, Y. (2014) · Bio-Medical Materials and Engineering · doi:10.3233/bme-141078 · Cited by 18
“For example, bone density is related to CT number by linear functions [12,14].”
BackgroundCaracterización mecánica del material óseo.
Rincón, E., Arranz, F., Felip, A. R., & Alonso, R. C. (2004) · Tecnología y desarrollo · Cited by 18
Load to failure of different zirconia implant abutments with titanium components
Mascarenhas, F., Yılmaz, B., McGlumphy, E. A., Clelland, N. L., & Seidt, J. D. (2016) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2016.09.008 · Cited by 18
Faisal, T. R., & Luo, Y. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0407-y · Cited by 18
The Effects of Dietary Boron on Bone Strength in Rats
Chapin, R. E., Ku, W. W., KENNEY, M. A., McCoy, H., Gladen, B. C., Wine, R. N., WILSON, R., & Elwell, M. R. (1997) · Toxicological Sciences · doi:10.1093/toxsci/35.2.205 · Cited by 18
Application of an image-based weighted measure of skeletal bending stiffness to great ape mandibles
Bhatavadekar, N., Daegling, D. J., & Rapoff, A. J. (2006) · American Journal of Physical Anthropology · doi:10.1002/ajpa.20397 · Cited by 18
Mulder, L., van Ruijven, L. J., Koolstra, J. H., & van Eijden, T. M. G. J. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9345-3 · Cited by 18
Sheykholeslami, S. O. R., Khalil‐Allafi, J., Etminanfar, M., Khalili, V., & Parsa, A. B. (2023) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2023.129410 · Cited by 17
Phuoc, H. D., Hoang, P. N., Yang, S. Y. S., Fraser, D., & Nguyen, V. (2023) · PLoS ONE · doi:10.1371/journal.pone.0282457 · Cited by 17
“Although Young’s moduli of titanium alloys are lower than those of stainless steel or other metallic biomaterials, they are still much higher than those of human bone [7, 8].”
BackgroundResultAnalysis of cartilage loading and injury correlation in knee varus deformity
Zhang, H., Ma, J., Tian, A., lu, B., Bai, H., Dai, J., Wu, Y., Chen, J., Luo, W. P., & Ma, X. (2024) · Medicine · doi:10.1097/md.0000000000038065 · Cited by 17
Mandibular Implants: A Metamaterial‐Based Approach to Reducing Stress Shielding
Heins, J., Merema, B. B. J., Kraeima, J., Witjes, M. J. H., & Krushynska, A. O. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202500405 · Cited by 17
Functionalization of Implantable Systems for Controlled Drug Delivery and Beyond
Blanco, A. F., Crecente‐Campo, J., & Alonso, M. J. (2025) · Regenerative Engineering and Translational Medicine · doi:10.1007/s40883-025-00401-4 · Cited by 17
Bačáková, L., Filová, E., Lišková, J., Kopová, I., Vandrovcová, M., & Havlikova, J. (2016) · Elsevier eBooks · doi:10.1016/b978-0-323-42862-0.00004-3 · Cited by 17
Müller, R., Henss, A., Kampschulte, M., Rohnke, M., Langheinrich, A. C., Heiss, C., Janek, J., Voigt, A., Wilke, H., Ignatius, A. A., et al. (2019) · Journal of The Royal Society Interface · doi:10.1098/rsif.2018.0793 · Cited by 17
Hasan, L. A., Qassar, S. S. S. A., Alrawi, M. N., & Alhajar, E. H. K. (2021) · Journal of Orthodontic Science · doi:10.4103/jos.jos_39_20 · Cited by 17
“[23] The Young’s modulus and Poisson’s ratio for cortical and cancellous bone were considered according to the ultrasound study of Rho et al.[33], while teeth properties were identified according to Boccaccio et al.”
MethodEffect of crown height on the screw joint stability of zirconia screw-retained crowns
Yılmaz, B., Gouveia, D. D. N. M., Seghi, R. R., Johnston, W. M., & Lang, L. A. (2021) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2021.02.027 · Cited by 17
Savoldelli, C., Ehrmann, E., & Tillier, Y. (2021) · Scientific Reports · doi:10.1038/s41598-021-88332-2 · Cited by 17
Could we use metallic wood for bone tissue engineering applications?
Beheshtizadeh, N., Zarei, M., & Azami, M. (2022) · Results in Engineering · doi:10.1016/j.rineng.2022.100845 · Cited by 17
Rehman, M., Wang, Y., Ishfaq, K., Yang, H., Mushtaq, R. T., Kumar, M. S., & Ahmed, A. (2023) · Rapid Prototyping Journal · doi:10.1108/rpj-02-2022-0042 · Cited by 17
Angulated abutments and perimplants stress: F.E.M. analysis.
Cardelli, P., Montani, M., Gallio, M., Biancolini, M. E., Brutti, C., & Barlattani, A. (2009) · Europe PMC (PubMed Central) · Cited by 18
Poly‐ether‐ether‐ketone and implant dentistry: the future of mimicking natural dentition is now!
Nobre, M. D. A., Guedes, C. M., Almeida, R., & Silva, A. J. (2021) · Polymer International · doi:10.1002/pi.6212 · Cited by 17
SAXENA, R., KELLERS, T. S., & SULLIVAN, J. M. (1999) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255849908907993 · Cited by 17
The loss of stiffness as osteoporosis progresses
Werner, H. J., Martin, H., Behrend, D., Schmitz, K., & Schober, H. (1996) · Medical Engineering & Physics · doi:10.1016/1350-4533(96)00012-4 · Cited by 17
Woodbury, S. M., Swanson, W. B., & Mishina, Y. M. (2023) · Frontiers in Physiology · doi:10.3389/fphys.2023.1220555 · Cited by 16
In Vivo Assessment of Bone Quality Without X-rays
Surowiec, R. K., Does, M. D., & Nyman, J. S. (2024) · Current Osteoporosis Reports · doi:10.1007/s11914-023-00856-w · Cited by 16
“Several early ex vivo studies described relationships between SOS parameters and mechanical properties of bone [15, 31, 32].”
Evolution of oxide film on the internal porosity of Ti-30Nb-13Ta-2Mn alloy foam
Guerra, C., Sancy, M., Walczak, M., da Silva, D. M., Martínez, C., Tribollet, B., & Aguilar, C. E. (2018) · Electrochimica Acta · doi:10.1016/j.electacta.2018.05.010 · Cited by 16
Network models for characterization of trabecular bone
Mondal, A., Nguyen, C., Ma, X., Elbanna, A. E., & Carlson, J. M. (2019) · Physical review. E · doi:10.1103/physreve.99.042406 · Cited by 16
Structure design and biological evaluation of the mechanical-adaptive titanium-based porous implants
Wang, Z., Yao, R., Wang, D., Wang, H., & Liang, C. (2020) · Materials Technology · doi:10.1080/10667857.2020.1800306 · Cited by 16
Cardinali, M. A., Morresi, A., Fioretto, D., Vivarelli, L., Dallari, D., & Govoni, M. (2021) · Materials · doi:10.3390/ma14226869 · Cited by 16
Endplate volumetric bone mineral density biomechanically matched interbody cage
Weng, Y., Di, M., Wu, T., Ma, X., Yang, Q., & Lu, W. W. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1075574 · Cited by 16
“The elastic modulus of cortical bone is in the range of 5–20 GPa (Rho et al., 1993; Duchemin et al., 2008).”
BackgroundWu, Y., Wang, C., Feng, K., Chien, R. R., Mana-ay, H., Kung, S.-Y., Hou, K.-H., Tu, C., Chen, P.-Y., & Lai, P. (2023) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2023.170450 · Cited by 16
Haptic Detection of Artificial Tumors by Hand and with a Tool in a MIS Environment
Greenwald, D., Cao, C. G. L., & Bushnell, E. W. (2011) · IEEE Transactions on Haptics · doi:10.1109/toh.2011.68 · Cited by 16
Stimmelmayr, M., Groesser, J., Beuer, F., Erdelt, K. J., Krennmair, G., Sachs, C., Edelhoff, D., & Güth, J. (2017) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2016.12.011 · Cited by 16
Bucciarelli, F., Fierro, G. P. M., Zarrelli, M., & Meo, M. (2019) · Applied Composite Materials · doi:10.1007/s10443-018-9754-5 · Cited by 16
Mechanical properties of zirconia periodic open cellular structures
Fabris, D., Mesquita‐Guimarães, J., Pinto, P., Souza, J. C. M., Fredel, M. C., Silva, F. S., & Henriques, B. A. P. D. C. (2019) · Ceramics International · doi:10.1016/j.ceramint.2019.05.010 · Cited by 16
Vogel, S., Ullm, F., Müller, C. D., Pompe, W., & Hempel, U. (2020) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00856 · Cited by 16
Giner, M., Chicardi, E., Costa, A. F., Santana, L., Vázquez, M. Á., García-Garrido, C., Colmenero, M. Á., Olmo-Montes, F. J., Torres, Y., & Montoya-García, M.-J. (2021) · Metals · doi:10.3390/met11010130 · Cited by 16
“Metals 2021, 11, x FOR PEER REVIEW 9 of 15 to 1 GPa, and 40 MPa of yield strength was calculated (see Table 1).”
BackgroundInfluentialHamed, E., Novitskaya, E. E., Li, J., Jasiuk, I., & McKittrick, J. M. (2015) · Materials Science and Engineering C · doi:10.1016/j.msec.2015.02.044 · Cited by 17
Yu, J. C.-K., Dinsmore, R., Mar, P. L., & Bhatt, K. A. (2011) · Journal of Craniofacial Surgery · doi:10.1097/scs.0b013e31821c6955 · Cited by 16
“The ultimate tensile stress represents how strong a material is; it is thus known as the strength of the material.(11) Pediatric bones are less stiff than adult bones, with lower tensile modulus (0.”
BackgroundExperimental and Numerical Analysis of Titanium/HA FGM for Dental Implantation
Sazesh, S., Ghassemi, A., Ebrahimi‐Kahrizsangi, R., & Khodaei, M. (2017) · international journal of advanced design and manufacturing technology · Cited by 16
Miljojković, J., Bijelić, I., Vranić, N., Radovanović, N., & Živković, M. (2017) · Tehnicki vjesnik - Technical Gazette · doi:10.17559/tv-20170609133537 · Cited by 16
Bioresorbable bone graft substitutes
Blokhuis, T. J. (2014) · Elsevier eBooks · doi:10.1533/9780857099037.1.80 · Cited by 16
Clason, C., Hinz, A., & Schieferstein, H. (2004) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255840412331313590 · Cited by 16
“It is known that bone is an inhomogeneous, anisotropic material, and the literature reports a wide range of values for material parameters [11, 20, 24 ].”
BackgroundLow-frequency ultrasonic velocity measurements in human calcaneal trabecular bone
Strelitzki, R., Nicholson, P., & Evans, J. A. (1997) · Physiological Measurement · doi:10.1088/0967-3334/18/2/003 · Cited by 16
Seaweed Derived Polysaccharides as Sustainable Biomaterials for Tissue Engineering Applications
Ghalsasi, P., Gobinath, C., & Joddar, B. (2025) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5c01301 · Cited by 15
Burchett, A. A., Siri, S., Li, J., Lü, X., & Datta, M. (2024) · Cellular and Molecular Bioengineering · doi:10.1007/s12195-024-00824-z · Cited by 15
Morphology analysis of vertebral trabecular bone under dynamic loading based on multi-scale theory
Basaruddin, K. S., TAKANO, N., Yoshiwara, Y., & Nakano, T. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0951-3 · Cited by 15
“4 [32].”
Bone fracture healing within a continuum bone remodelling framework
Schmidt, I., Albert, J., Ritthaler, M., Papastavrou, A., & Steinmann, P. (2021) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2021.1998465 · Cited by 15
“It is typically set to n¼ 2 for trabecular bone with low nominal density and to n> 2 for denser bone, compare to Gibson (2005) and Rho et al. (1993).”
BackgroundElastic Modulus of Cetacean Auditory Ossicles
Tubelli, A. A., Zosuls, A., Ketten, D. R., & Mountain, D. C. (2014) · The Anatomical Record · doi:10.1002/ar.22896 · Cited by 15
Lee, K.-L., Sobieraj, M. C., Baldassarri, M., Gupta, N., Pinisetty, D., Janal, M. N., Tovar, N., & Coelho, P. G. (2013) · Materials Science and Engineering C · doi:10.1016/j.msec.2013.07.018 · Cited by 15
Russell, R. D., Huo, M. H., Rodrigues, D. C., & Kosmopoulos, V. (2016) · Technology and Health Care · doi:10.3233/thc-161235 · Cited by 15
“In both models, cortical bone was modeled as an orthotropic material characterized by nine independent technical constants ( E 1 = 12.0, E 2 = 13.4, E 3 = 20.0 GPa; G 12 = 4.53, G 23 = 6.23, G 13 = 5.61 GPa; ν 12 = 0.376; ν 23 = 0.235, ν 13 = 0.222) [14,15] with a density of 1817 kg/m 3 [16].”
InfluentialEffects of direction and shape of osteocyte lacunae on resisting impact and micro-damage of osteon
Liu, Y., Chen, B., & Yin, D. (2017) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-017-5850-6 · Cited by 15
Du, L., Li, Z., Chang, X., Rahhal, O., Qin, B., Wen, X., & Zhou, D. (2018) · Implant Dentistry · doi:10.1097/id.0000000000000812 · Cited by 15
3D Printing-Processed Polymers for Dental Applications
Cristache, C. M., & Totu, E. E. (2020) · Springer eBooks · doi:10.1007/978-3-030-50457-1_7 · Cited by 15
Biomechanical aspects of bone repair
Lacroix, D. (2009) · Elsevier eBooks · doi:10.1533/9781845696610.1.106 · Cited by 18
A Framework of Data-Enabled Science for Evaluation of Material Damage Based on Acoustic Emission
Qi, G., & Wayne, S. F. (2014) · Journal of Nondestructive Evaluation · doi:10.1007/s10921-014-0255-7 · Cited by 15
Clinical experiences with ultrasonometric measurement of fracture healing
Glinkowski, W., & Górecki, A. (2006) · Technology and Health Care · doi:10.3233/thc-2006-144-514 · Cited by 15
“Ultrasound velocity measurement in situ predicts the material properties of cortical or cancellous bone and seems to be sufficiently reliable in clinical bone research [7,9,13,21, 27,30,32,39,40,49–54,57,58,69,73,77–79,87,92,98,99].”
Du, Z., Wang, S., Yue, B., Wang, Y., & Wang, Y. (2017) · Oncotarget · doi:10.18632/oncotarget.23757 · Cited by 15
Testing Two Predictions for Fracture Load Using Computer Models of Trabecular Bone
Liebschner, M. A. K., Müller, R., Wimalawansa, S. J., Rajapakse, C. S., & Gunaratne, G. H. (2005) · Biophysical Journal · doi:10.1529/biophysj.104.057539 · Cited by 15
Análise do risco de fratura óssea por ultrasonometria e ensaio mecânico de compressão
Rodrigues, M. E. D. S. (2004) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.82.2004.tde-22042004-093459 · Cited by 15
Scaffold-Dependent Mechanical and Architectural Cues Guide Osteochondral Defect Healing in silico
Tortorici, M., Petersen, A., Ehrhart, K., Duda, G. N., & Checa, S. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.642217 · Cited by 14
“, 2012), although values up to 10–15 GPa were reported for the trabecular bone material depending on the measurement method (Rho et al., 1993)].”
MethodTrueba, P., Navarro, C., Giner, M., Rodríguez-Ortiz, J. A., Montoya-García, M.-J., Delgado-Pujol, E. J., Rodríguez-Albelo, L. M., & Torres, Y. (2022) · Materials · doi:10.3390/ma15113903 · Cited by 14
“In summary, SH 30 vol.% the chemical etching of dental implants presents the best bio-functional (in vitro osseointegration) and bio-mechanical (stiffness, yield strength and fatigue life) balance, which could guarantee the requirements of cortical bone tissue (E = 20–25 GPa, Òy = 150–180 MPa, and KIc = 3.5 MNm−3/2).”
BackgroundInfluentialDo lateral ankle ligaments contribute to syndesmotic stability: a finite element analysis study
Mercan, N., Yurteri, A., & Dere, Y. (2023) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2023.2258251 · Cited by 14
“The elasticity modules of cortical bone and cancellous bone was determined based on the studies in the literature (Rho et al. 1993; Gray et al. 2008) and these data are shown in Table 4.”
Rai, A., Rai, P., Kumar, V., Singh, N. K., & Singh, V. K. (2020) · Metals and Materials International · doi:10.1007/s12540-020-00748-z · Cited by 14
Faisal, T. R., & Luo, Y. (2016) · Bio-Medical Materials and Engineering · doi:10.3233/bme-161563 · Cited by 14
“Although bone is anisotropic [35,36], the existing empirical modulus-density relationships are for isotropic properties [37–41].”
BackgroundChan, C.-W., Carson, L., & Smith, G. C. (2018) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2018.06.015 · Cited by 14
“Interestingly, NiTi in its martensitic state possess a desirable characteristic of very low elastic modulus (between 26-48 GPa)[5] which is much lower than that in its austenitic state (about 83 GPa)[5] and much closer to that of the cortical bone (between 19 to 21 GPa)[6].”
BackgroundUltra-High Molecular Weight Polyethylene/Titanium-Hybrid Implant for Bone-Defect Replacement
Maksimkin, A. V., Senatov, F. S., Niaza, K. V., Dayyoub, T., & Kaloshkin, S. D. (2020) · Materials · doi:10.3390/ma13133010 · Cited by 14
Bacci, C., Wong, V., Barahona, V., & Merna, N. (2020) · Microcirculation · doi:10.1111/micc.12659 · Cited by 14
Micro-cantilever bending for elastic modulus measurements of a single trabecula in cancellous bone
Yamada, S., TADANO, S., & Fukasawa, K. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.10.016 · Cited by 14
“…values fall within the range reported for a single 152 trabecula under dry conditions (2–16 GPa; Yamada et al., 2014; Carretta et al., 2013b, 153 2013c; Busse et al., 2009; Bini et al., 2002; Rho et al., 1993), including different species, 154 ages, locations, size, and types of mechanical test.”
BackgroundMethodSu, A. W. Y., Chen, Y., Dong, Y., Wailes, D. H., Wong, V. W., Chen, A. C., Cai, S., Bugbee, W. D., & Sah, R. L. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.03.037 · Cited by 14
“The axial displacement of the OCG subchondral bone was considered negligible, based on the compressive modulus being 1000x higher for bone (Rho et al., 1993) than articular cartilage (Korhonen et al.”
Effect of a growth hormone treatment on bone orthotropic elasticity in dwarf rats
Kohles, S. S., Martinez, D. A., Bowers, J. R., VAILAS, A. C., & Vanderby, R. (1997) · Annals of Biomedical Engineering · doi:10.1007/bf02738540 · Cited by 14
“0 ram) cortical and trabecular specimens (4,5,26,33,40) harvested from human and large animal models.”
BackgroundKoller, W., GONÇALVES, B. A. M., Baca, A., & Kainz, H. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1140527 · Cited by 13
“The chosen values for material properties were based on literature and previously used values inmechanobiological growth studies (Linde et al., 1985; Rho et al., 1993; Carriero et al., 2011; Yadav et al., 2016; Kainz et al., 2020).”
BackgroundMethodEvaluation of osseointegration of plasma treated polyaryletherketone maxillofacial implants
Maruf, D. S. A. A., Ren, J., Cheng, K., Xin, H., Lewin, W., Pickering, E., Kruse, H. V., Leinkram, D., Parthasarathi, K., Wise, I. K., et al. (2025) · Scientific Reports · doi:10.1038/s41598-024-80335-z · Cited by 13
“Titanium has an elastic modulus (110 GPa) 7 several times higher than that of cortical (18–20 GPa) 8–10 or cancellous bone (10–14 GPa) 11 .”
Mori, Y., Tanaka, H., Kurishima, H., Kanabuchi, R., Mori, N., SASAGAWA, K., & Aizawa, T. (2025) · Applied Sciences · doi:10.3390/app15094827 · Cited by 13
ILIC, S., Hackl, K., & Gilbert, R. P. (2011) · Journal of Theoretical and Computational Acoustics · doi:10.1142/s0218396x11004407 · Cited by 13
Hieda, J., Niinomi, M., Nakai, M., Cho, K., & Nagai, S. (2013) · MATERIALS TRANSACTIONS · doi:10.2320/matertrans.mf201308 · Cited by 13
Su, A. W. Y., Chen, Y., Wailes, D. H., Wong, V. W., Cai, S., Chen, A. C., Bugbee, W. D., & Sah, R. L. (2017) · Journal of Orthopaedic Research® · doi:10.1002/jor.23645 · Cited by 13
Mielke, M., & Nyakatura, J. A. (2019) · Zoomorphology · doi:10.1007/s00435-019-00456-2 · Cited by 13
Chen, T., Brial, C., McCarthy, M. M., Warren, R. F., & Maher, S. A. (2021) · The American Journal of Sports Medicine · doi:10.1177/03635465211028566 · Cited by 13
“within the range of bone.(48) The PVA 1 pTi implant then underwent an additional 3 freeze/thaw cycles, after which the implants were frozen and shaved to a final height of 10.”
MethodA novel specimen shape for measurement of linear strain fields by means of digital image correlation
Amraish, N., Reisinger, A., & Pahr, D. H. (2021) · Scientific Reports · doi:10.1038/s41598-021-97085-x · Cited by 13
Greybe, D. G., Boland, M. R., Wu, T., & Mithraratne, K. (2016) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2790 · Cited by 13
“A Young’s modulus of 2MPa was assumed for cartilage [31–33], 600MPa for cancellous bone [34–36], and 18GPa for cortical bone [37, 38].”
BackgroundTowards deep learning based estimation of fracture risk in osteoporosis patients
Ciusdel, C. F., Vizitiu, A., Moldoveanu, F. D., Suciu, C., & Lucian Mihai, I. T. U. (2017) · International Conference on Telecommunications and Signal Processing (TSP) · doi:10.1109/tsp.2017.8076069 · Cited by 13
“3 [8]).”
Bera, S., Paul, S., Ramasamy, P., Mandal, D., Das, M., Lassnig, A., Renk, O., Calin, M., & Eckert, J. (2019) · Scripta Materialia · doi:10.2139/ssrn.3427503 · Cited by 13
A combined experimental and numerical method to estimate the elastic modulus of single trabeculae
Wu, D., Joffre, T., Öhman‐Mägi, C., Ferguson, S. J., Persson, C., & Isaksson, P. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104879 · Cited by 13
A modified Coulomb’s law for the tangential debonding of osseointegrated implants
Immel, K., Duong, T. X., Nguyen, V., Haïat, G., & Sauer, R. A. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-019-01272-9 · Cited by 13
Mechanobiology, tissue development, and tissue engineering
Li, D., & Wang, Y. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818422-6.00015-0 · Cited by 13
Kuhn, F., Clausing, R. J., Stiller, A., Ulloa, C. A. F., Fölsch, C., Rickert, M., & Jahnke, A. (2022) · Journal of Orthopaedics · doi:10.1016/j.jor.2022.07.003 · Cited by 13
Bartkowska, A., Careta, O., Turner, A. B., Blanquer, A., Ibáñez, E., Trobos, M., Nogués, C., Pellicer, E., & Sort, J. (2022) · Materials Advances · doi:10.1039/d2ma00867j · Cited by 13
Baudequin, T., Bédoui, F., Dufresne, M., Paullier, P., & Legallais, C. (2015) · Tissue Engineering Part A · doi:10.1089/ten.tea.2014.0580 · Cited by 13
“59 estimated it at 10.4 – 3.5 GPa for trabecular bone with a mechanical method.”
InfluentialEffects of knee flexion on the femoropopliteal artery: A computational study
Ghriallais, R. N., & Bruzzi, M. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.05.015 · Cited by 13
A simulation study of marrow fat effect on bone biomechanics
Ma, H. T., Ren, R., Chen, Y., Griffith, J. F., Leung, P.-C., & Zhang, P. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944508 · Cited by 13
Kuznetsova, D. S., Timashev, P. S., Dudenkova, V. V., Meleshina, A. V., Antonov, E. A., Кротова, Л. И., Popov, V. K., Bagratashvili, V. N., & Вадимовна, З. Е. (2016) · Bulletin of Experimental Biology and Medicine · doi:10.1007/s10517-016-3214-8 · Cited by 13
Mitton, D., Roux, C., & Laugier, P. (2010) · Springer eBooks · doi:10.1007/978-94-007-0017-8_1 · Cited by 14
Differential Effects of Primary Hyperparathyroidism on Ultrasound Properties of Bone
Ingle, B. M., Thomas, W. E. G., & Eastell, R. (2002) · Osteoporosis International · doi:10.1007/s001980200075 · Cited by 13
“Speed of sound (SOS) reflects bone mass and elasticity (the resistance to deformation) [1-3].”
BackgroundEffects of callus and bonding on strains in bone surrounding an implant under bending.
Huja, S. S., Qian, H., Roberts, W. E., & Katona, T. R. (1998) · PubMed · Cited by 13
Lee, H. H., Hong, H.-T., Kim, J.-K., Koh, Y., Park, K. K., & Kang, K.-T. (2025) · Bioengineering · doi:10.3390/bioengineering12020172 · Cited by 12
“In reality, bone exhibits anisotropic and heterogeneous behavior, which significantly affects the mechanical response under various loading conditions [26].”
Coquart, P., Haddad, A. E., Koutsouras, D. A., & Bolander, J. (2025) · Biosensors · doi:10.3390/bios15040253 · Cited by 12
Increased substrate stiffness disrupts nuclear-cytoskeletal mechanical coupling in senescent cells
Molina, M. S., Brauer, E., Günther, R., Diederich, S., & Petersen, A. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.102472 · Cited by 12
Blouin, S., Puchegger, S., Roschger, A., Berzlanovich, A. M., Fratzl, P., Klaushofer, K., & Roschger, P. (2014) · Microscopy and Microanalysis · doi:10.1017/s1431927614000646 · Cited by 12
“In cortical bone a higher velocity of 3,369 m/s was found compared with 2,892 m/s measured in cancellous bone of the same human tibia, using a 2.25 MHz transducer (Rho et al., 1993).”
ResultInfluentialEsmaeili, E., Malaie-Balasi, Z., Kabiri, M., Khojasteh, A., Mohamadyar‐Toupkanlou, F., Sadeghzadeh, N., Zarei‐Behjani, Z., & Hosseinzadeh, S. (2021) · ASAIO Journal · doi:10.1097/mat.0000000000001355 · Cited by 12
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.