Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Mechanical properties and the hierarchical structure of bone
Rho, J.-Y., Kuhn-Spearing, L., & Zioupos, P. (1998) · Medical Engineering & Physics · doi:10.1016/s1350-4533(98)00007-1 · Cited by 2,588
“However, many investigators produced values for the elastic modulus of individual trabeculae, single osteons, and a thin cortical shell that were considerably less than that for whole bone [5,17,18].”
BackgroundResultSelf-citationWang, X., Xu, S., Zhou, S., Xu, W., Leary, M., Choong, P., Qian, M., Brandt, M., & Xie, Y. M. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.012 · Cited by 2,121
“The pore s in trabecular bone are filled with bone marrow, a nd the porosity varies between 50-90% [1, 36-38].”
BackgroundMethodBasic biomechanical measurements of bone: A tutorial
Turner, C. H., & Burr, D. B. (1993) · Bone · doi:10.1016/8756-3282(93)90081-k · Cited by 1,666
Self-citationThe stiffness of living tissues and its implications for tissue engineering
Guimarães, C. F., Gasperini, L., Marques, A. P., & Reis, R. L. (2020) · Nature Reviews Materials · doi:10.1038/s41578-019-0169-1 · Cited by 1,515
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
“For the other three anatomic sites, the computed tissue moduli fall within the range of values reported by ultrasound (Rho et al., 1993; Turner et al., 1999) and nanoindentation (Hengsberger et al.”
BackgroundBone Mechanical Properties in Healthy and Diseased States
Morgan, E. F., Unnikrisnan, G. U., & Hussein, A. I. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-121139 · Cited by 1,026
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
Elastic properties of human cortical and trabecular lamellar bone measured by nanoindentation
Rho, J.-Y., Tsui, T. Y., & Pharr, G. M. (1997) · Biomaterials · doi:10.1016/s0142-9612(97)00073-2 · Cited by 924
Self-citationApplications of polyetheretherketone (PEEK) in oral implantology and prosthodontics
Najeeb, S., Zafar, M. S., Khurshid, Z., & Siddiqui, F. (2016) · Journal of Prosthodontic Research · doi:10.1016/j.jpor.2015.10.001 · Cited by 897
van Rietbergen, B., Weinans, H., Huiskes, R., & Odgaard, A. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)80008-5 · Cited by 865
Relations of mechanical properties to density and CT numbers in human bone
Rho, J. Y., Hobatho, M. C., & Ashman, R. B. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)97314-f · Cited by 822
Self-citationBiomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Applications of synthetic polymers in clinical medicine
Maitz, M. F. (2015) · Biosurface and Biotribology · doi:10.1016/j.bsbt.2015.08.002 · Cited by 726
Calcium phosphate coatings on magnesium alloys for biomedical applications: A review
Shadanbaz, S., & Dias, G. J. (2012) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.10.016 · Cited by 651
“6–27 GPa, respectively [9–13].”
Supervised autonomous robotic soft tissue surgery
Shademan, A., Decker, R. S., Opfermann, J. D., Leonard, S., Krieger, A., & Kim, P. C. W. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aad9398 · Cited by 620
Turner, C. H., Rho, J., Takano, Y., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00177-8 · Cited by 547
Self-citationBiomechanics and Mechanobiology of Trabecular Bone: A Review
Oftadeh, R., Perez-Viloria, M., Villa-Camacho, J. C., Vaziri, A., & Nazarian, A. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4029176 · Cited by 547
Tan, X. P., Tan, Y. J., Chow, C. S. L., Tor, S. B., & Yeong, W. Y. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.02.094 · Cited by 514
Metallic Scaffolds for Bone Regeneration
Alvarez, K., & Nakajima, H. (2009) · Materials · doi:10.3390/ma2030790 · Cited by 505
“However, as can be seen in Table 1, some authors have found a value of elastic modulus of trabecular bone as high as those for cortical bone apparently because the test specimens were dried before the mechanical tests [12,16,18,19].”
BackgroundTada, S., Stegaroiu, R., 北村, 絵., Miyakawa, O., & Kusakari, H. (2003) · PubMed · Cited by 444
Bioengineering strategies to accelerate stem cell therapeutics
Madl, C. M., Heilshorn, S. C., & Blau, H. M. (2018) · Nature · doi:10.1038/s41586-018-0089-z · Cited by 425
Adhesion to tooth structure: A critical review of “micro” bond strength test methods
Armstrong, S., Geraldeli, S., Maia, R., Raposo, L. H. A., Soares, C. J., & Yamagawa, J. (2010) · Dental Materials · doi:10.1016/j.dental.2009.11.155 · Cited by 422
Proposal for the regulatory mechanism of Wolff's law
Mullender, M. G., & Huiskes, R. (1995) · Journal of Orthopaedic Research · doi:10.1002/jor.1100130405 · Cited by 408
Nanotopography-guided tissue engineering and regenerative medicine
Kim, H. N., Jiao, A., Hwang, N. S., Kim, M. S., Kang, D. H., Kim, D.-H., & Suh, K.-Y. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.07.014 · Cited by 404
Emerging Biofabrication Strategies for Engineering Complex Tissue Constructs
Pedde, R. D., Mirani, B., Navaei, A., Styan, T., Wong, S., Mehrali, M., Thakur, A., Mohtaram, N. K., Bayati, A., Dolatshahi‐Pirouz, A., et al. (2017) · Advanced Materials · doi:10.1002/adma.201606061 · Cited by 388
Hengsberger, S., Kulik, A., & Zysset, P. (2002) · Bone · doi:10.1016/s8756-3282(01)00624-x · Cited by 363
Elastic properties of microstructural components of human bone tissue as measured by nanoindentation
Rho, J.-Y., Roy, M. E., Tsui, T. Y., & Pharr, G. M. (1999) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199904)45:1<48::aid-jbm7>3.0.co;2-5 · Cited by 348
Self-citationBiomechanical considerations of animal models used in tissue engineering of bone
Liebschner, M. A. K. (2004) · Biomaterials · doi:10.1016/s0142-9612(03)00515-5 · Cited by 329
“In cortical bone, a specimen at the tissue level generally incorporates several portions of interstitial regions or osteons, or maybe a single osteon [27,28].”
BackgroundSagomonyants, K. B., Jarman-Smith, M. L., Devine, J. N., Aronow, M. S., & Gronowicz, G. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2007.12.001 · Cited by 320
A 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
Synthetic bone: Design by additive manufacturing
Barba, D., Alabort, E., & Reed, R. C. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.07.049 · Cited by 316
Ciarelli, T. E., Fyhrie, D. P., Schaffler, M. B., & Goldstein, S. A. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.1.32 · Cited by 308
van Eijden, T. M. (2000) · Critical Reviews in Oral Biology & Medicine · doi:10.1177/10454411000110010101 · Cited by 304
Fundamentals of Biomechanics in Tissue Engineering of Bone
Athanasiou, K. A., Zhu, C.-F., Lanctot, D. R., Agrawal, C. M., & Wang, X. (2000) · Tissue Engineering · doi:10.1089/107632700418083 · Cited by 301
北村, 絵., Stegaroiu, R., Nomura, S., & Miyakawa, O. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01022.x · Cited by 300
Application of the finite element method in dental implant research
Van Staden, R. C., Guan, H., & Loo, Y. C. (2006) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840600837074 · Cited by 298
“This might also have led to unrealistic results (Rho et al. 1993).”
Lalwani, G., Henslee, A. M., Farshid, B., Lin, L., Kasper, F. K., Qin, Y.-X., Mikos, A. G., & Sitharaman, B. (2013) · Biomacromolecules · doi:10.1021/bm301995s · Cited by 293
Biodegradable Magnesium Alloys: A Review of Material Development and Applications
Persaud-Sharma, D., & McGoron, A. (2012) · Journal of Biomimetics, Biomaterials and Tissue Engineering · doi:10.4028/www.scientific.net/jbbte.12.25 · Cited by 287
“Magnesium alloys are especially important for orthopaedic applications as it contains a Young’s modulus with a value of 3-20 GPa, which is very similar to the Young’s modulus for bone 20 GPa [55].”
Rho, J. Y., Zioupos, P., Currey, J. D., & Pharr, G. M. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00199-3 · Cited by 276
Self-citationFerretti, J. L., Capozza, R. F., & Zanchetta, J. R. (1996) · Bone · doi:10.1016/8756-3282(95)00438-6 · Cited by 264
Young’s modulus of trabecular bone at the tissue level: A review
Wu, D., Isaksson, P., Ferguson, S. J., & Persson, C. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.08.001 · Cited by 263
Heterogeneity of bone lamellar-level elastic moduli
Hoffler, C. E., Moore, K. E., Kozloff, K., Zysset, P. K., Brown, M. B., & Goldstein, S. A. (2000) · Bone · doi:10.1016/s8756-3282(00)00268-4 · Cited by 259
Trabecular Bone Tissue Strains in the Healthy and Osteoporotic Human Femur
Van Rietbergen, B., Huiskes, R., Eckstein, F., & Rüegsegger, P. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.10.1781 · Cited by 256
“5 GPa for cortical and 15 GPa for trabecular bone tissue.((9,10)) A physiological distributed load was applied normal to the femoral head surfaces.”
BackgroundBone tissue compositional differences in women with and without osteoporotic fracture
McCreadie, B. R., Morris, M. D., Chen, T.-C., Sudhaker Rao, D., Finney, W. F., Widjaja, E., & Goldstein, S. A. (2006) · Bone · doi:10.1016/j.bone.2006.06.008 · Cited by 253
“Several studies have reported wide variations in tissue mechanical properties and differences in properties between bone types, although little difference with age or between males and females has been found [5–11].”
Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures
Müller, R., & Rüegsegger, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91884-j · Cited by 240
Stimmelmayr, M., Edelhoff, D., Güth, J., Erdelt, K. J., Happe, A., & Beuer, F. (2012) · Dental Materials · doi:10.1016/j.dental.2012.08.008 · Cited by 239
Ma, S., Tang, Q., Han, X., Feng, Q., Song, J., Setchi, R., Liu, Y., Liu, Y., Goulas, A., Engstrøm, D. S., et al. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.109034 · Cited by 237
Ali, D., & Sen, S. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.07.035 · Cited by 237
PEEK with Reinforced Materials and Modifications for Dental Implant Applications
Rahmitasari, F., Ishida, Y., Kurahashi, K., Matsuda, T., Watanabe, M., & Ichikawa, T. (2017) · Dentistry Journal · doi:10.3390/dj5040035 · Cited by 233
A review of bioceramic porous scaffolds for hard tissue applications: Effects of structural features
Jodati, H., Yılmaz, B., & Evis, Z. (2020) · Ceramics International · doi:10.1016/j.ceramint.2020.03.192 · Cited by 232
3D in vitro modeling of the central nervous system
Hopkins, A. M., DeSimone, E., Chwalek, K., & Kaplan, D. L. (2015) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2014.11.003 · Cited by 228
“…and single brain cells (Lu et al., 2006) to ~90-230 kPa for spinal cord (Chang et al., 1988; Levental et al., 2007), which is similar to muscle fibers (~30-50 kPa, (Fridén and Lieber, 2003)) and skin (10-100 kPa, (Zheng and Mak, 1997)) and much softer than bone (106-107 kPa, (Rho et al., 1993)).”
Analysis of a femoral hip prosthesis designed to reduce stress shielding
Joshi, M. G., Advani, S. G., Miller, F., & Santare, M. H. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00110-x · Cited by 228
Hernandez, C. J., Tang, S. Y., Baumbach, B. M., Hwu, P. B., Sakkee, A. N., van der Ham, F., DeGroot, J., Bank, R. A., & Keaveny, T. M. (2005) · Bone · doi:10.1016/j.bone.2005.07.019 · Cited by 227
“A number of studies have biomechanically tested individual trabeculae [23–26] and uniformly shaped (micromachined) specimens derived from trabeculae [27–29] to measure either elastic modulus or fatigue properties of the trabecular bone tissue; however, they did not report on ductility or collagen intermolecular status.”
BackgroundScaffold Translation: Barriers Between Concept and Clinic
Hollister, S. J., & Murphy, W. L. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2011.0251 · Cited by 224
“31 Fixation requirements are also mechanical, specifically requiring that motion at the scaffold/native bone interface be minimized 32–36 (strain 2%– 3% 36 ) to avoid pseudarthrosis.”
An Application of Nanoindentation Technique to Measure Bone Tissue Lamellae Properties
Hoffler, C. E., Guo, X. E., Zysset, P. K., & Goldstein, S. A. (2005) · Journal of Biomechanical Engineering · doi:10.1115/1.2073671 · Cited by 222
Finite element analysis to determine implant preload
Lang, L. A., Kang, B., Wang, R., & Lang, B. R. (2003) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2003.09.012 · Cited by 220
Powder metallurgy with space holder for porous titanium implants: A review
Rodríguez‐Contreras, A., Punset, M., Calero, J. A., Gil, F. J., Rupérez, E., & Manero, J. M. (2020) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2020.11.005 · Cited by 216
Estimating temperature exposure of burnt bone — A methodological review
Ellingham, S. T. D., Thompson, T. J. U., Islam, M., & Taylor, G. (2015) · Science & Justice · doi:10.1016/j.scijus.2014.12.002 · Cited by 209
“In the 1980s and 90s many studies were launched investigating the tensile strength of various species and bone types, as well as changes as a consequence of diagenesis by determining Young's Modulus, a measure of a material's stiffness and elasticity commonly used in material's studies [49–51].”
Background3D Printing and Electrospinning of Composite Hydrogels for Cartilage and Bone Tissue Engineering
De Mori, A., Peña Fernández, M., Blunn, G., Tozzi, G., & Roldo, M. (2018) · Polymers · doi:10.3390/polym10030285 · Cited by 206
Silk Hydrogels as Soft Substrates for Neural Tissue Engineering
Hopkins, A. M., De Laporte, L., Tortelli, F., Spedden, E., Staii, C., Atherton, T. J., Hubbell, J. A., & Kaplan, D. L. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201300435 · Cited by 205
Carbon nanotube reinforced hydroxyapatite composite for orthopedic application: A review
Lahiri, D., Ghosh, S., & Agarwal, A. (2012) · Materials Science and Engineering: C · doi:10.1016/j.msec.2012.05.010 · Cited by 205
Akhmanova, M., Osidak, E., Domogatsky, S., Rodin, S., & Domogatskaya, A. (2015) · Stem Cells International · doi:10.1155/2015/167025 · Cited by 200
“Bone (cortical bone) 10–20GPa Ultrasonic and microtensile test [35]”
BackgroundJang, I. G., & Kim, I. Y. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.05.037 · Cited by 200
“It is wellknown that the cancellous bone tissue is stiffer than the cortical bone (Rho et al., 1993; Turner et al., 1999), but most of the previous numerical studies did not take this into account.”
ResultMultiscale modeling of elastic properties of cortical bone
Hamed, E., Lee, Y., & Jasiuk, I. (2010) · Acta Mechanica · doi:10.1007/s00707-010-0326-5 · Cited by 199
Bioprinting 101: Design, Fabrication, and Evaluation of Cell-Laden 3D Bioprinted Scaffolds
Deo, K. A., Singh, K. A., Peak, C. W., Alge, D. L., & Gaharwar, A. K. (2020) · Tissue Engineering Part A · doi:10.1089/ten.tea.2019.0298 · Cited by 199
Human vertebral body apparent and hard tissue stiffness
Hou, F. J., Lang, S. M., Hoshaw, S. J., Reimann, D. A., & Fyhrie, D. P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00110-9 · Cited by 197
Hamdan, A., Guetta, V., Konen, E., Goitein, O., Segev, A., Raanani, E., Spiegelstein, D., Hay, I., Di Segni, E., Eldar, M., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.09.045 · Cited by 195
Hickey, D. J., Ercan, B., Sun, L., & Webster, T. J. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.12.004 · Cited by 193
“The tested materials fit well for cancellous bone applications (elastic modulus of 100–4500 MPa), but considerable modification would be needed to match the mechanical properties of cortical bone (elastic modulus of 17 GPa) [34].”
BackgroundThe role of an effective isotropic tissue modulus in the elastic properties of cancellous bone
Kabel, J., van Rietbergen, B., Dalstra, M., Odgaard, A., & Huiskes, R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00045-7 · Cited by 191
“, 1990) and on the testing method used (Ashman and Rho, 1988; Choi and Goldstein, 1992; Kuhn et al., 1989; Rho et al., 1993; Ryan and Williams, 1989; Townsend et al., 1975), indicating that one single value for &the tissue modulus' might not exist.”
BackgroundMethodInfluentialGrowth of C57Bl/6 Mice and the Material and Mechanical Properties of Cortical Bone from the Tibia
Somerville, J. M., Aspden, R. M., Armour, K. E., Armour, K. J., & Reid, D. M. (2004) · Calcified Tissue International · doi:10.1007/s00223-003-0101-x · Cited by 189
“An ultrasonic method was used to determine the elastic modulus of the bone in the 2-mm slice that was cut from the end of the diaphysis [9–11].”
MethodMechanical and biological characteristics of diamond-like carbon coated poly aryl-ether-ether-ketone
Wang, H., Xu, M., Zhang, W., Kwok, D. T. K., Jiang, J., Wu, Z., & Chu, P. K.-H. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.07.054 · Cited by 189
Bahl, S., Suwas, S., & Chatterjee, K. (2021) · International Materials Reviews · doi:10.1080/09506608.2020.1735829 · Cited by 187
Exercise Early and Often: Effects of Physical Activity and Exercise on Women’s Bone Health
Troy, K. L., Mancuso, M. E., Butler, T. A., & Johnson, J. E. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15050878 · Cited by 185
Van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R. (1998) · Journal of Orthopaedic Research · doi:10.1002/jor.1100160105 · Cited by 184
Polymer Synthesis and Processing
Kariduraganavar, M. Y., Kittur, A. A., & Kamble, R. R. (2014) · Elsevier eBooks · doi:10.1016/b978-0-12-396983-5.00001-6 · Cited by 184
Nicholson, P., Müller, R., Lowet, G., Cheng, X. G., Hildebrand, T., Ruegsegger, P., der Perre, G. V., Dequeker, J., & Boonen, S. (1998) · Bone · doi:10.1016/s8756-3282(98)00128-8 · Cited by 180
Wang, H., Haeger, S. M., Kloxin, A. M., Leinwand, L. A., & Anseth, K. S. (2012) · PLoS ONE · doi:10.1371/journal.pone.0039969 · Cited by 179
“1 kPa to ,20 GPa [4,47].”
Homminga, J., McCreadie, B. R., Ciarelli, T. E., Weinans, H., Goldstein, S. A., & Huiskes, R. (2002) · Bone · doi:10.1016/s8756-3282(02)00693-2 · Cited by 177
Dental implants from functionally graded materials
Mehrali, M., Shirazi, F. S., Mehrali, M., Metselaar, H. S. C., Kadri, N. A., & Osman, N. A. A. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34588 · Cited by 176
“Therefore, HA is clinically applied to the teeth.78–80 However, the mechanical strength of HA is remarkably low TABLE I. Materials and Bone Properties Materials Young’s Modulus (GPa) Poisson’s Ratio Density (kg/m3) Reference Cortical bone 14 0.3 1700 Rho et al.44 Cancellous bone 3 0.3 270 Rho et al.44 Enamel 10.5 0.33…”
BackgroundInfluentialNanomodified Peek Dental Implants: Bioactive Composites and Surface Modification—A Review
Najeeb, S., Khurshid, Z., Matinlinna, J. P., Siddiqui, F., Nassani, M. Z., & Baroudi, K. (2015) · International Journal of Dentistry · doi:10.1155/2015/381759 · Cited by 175
“Meanwhile, Young’s modulus of carbon-reinforced PEEK (CFR-PEEK) is around 18GPa [7] which is close to that of cortical bone [20, 21].”
BackgroundLoad distribution in the healthy and osteoporotic human proximal femur during a fall to the side
Verhulp, E., van Rietbergen, B., & Huiskes, R. (2008) · Bone · doi:10.1016/j.bone.2007.08.039 · Cited by 174
“5 GPa for cortical bone [5,6], respectively.”
Vlaisavljevich, E., Maxwell, A. D., Warnez, M. T., Johnsen, E., Cain, C. A., & Xu, Z. (2014) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2014.6722618 · Cited by 174
Yang, J., & Xiang, H. (2007) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2006.11.019 · Cited by 172
Ladd, A. J. C., Kinney, J. H., Haupt, D. L., & Goldstein, S. A. (1998) · Journal of Orthopaedic Research · doi:10.1002/jor.1100160516 · Cited by 171
The Importance of Mechanical Forces for in vitro Endothelial Cell Biology
Gordon, E., Schimmel, L., & Frye, M. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.00684 · Cited by 171
Van Rietbergen, B., Müller, R., Ulrich, D., Rüegsegger, P., & Huiskes, R. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00150-x · Cited by 170
“Second, a unique Young’s modulus for all tissues was used in the model, whereas several investigators have found that the trabecular tissue properties are less than those of cortical bone (Rho et al., 1993; Choi et al., 1990; Kuhn et al., 1989).”
MethodDesign of Injectable Materials to Improve Stem Cell Transplantation
Marquardt, L. M., & Heilshorn, S. C. (2016) · Current Stem Cell Reports · doi:10.1007/s40778-016-0058-0 · Cited by 169
Razfar, N., Reeves, J. M., Langohr, G. D. G., Willing, R. T., Athwal, G. S., & Johnson, J. A. (2016) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2015.11.011 · Cited by 167
Patterning Methods for Polymers in Cell and Tissue Engineering
Kim, H. N., Kang, D.-H., Kim, M. S., Jiao, A., Kim, D.-H., & Suh, K.-Y. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0510-y · Cited by 165
Vertebral Osteoporosis and Trabecular Bone Quality
Donnell, P. M., McHugh, P. E., & Mahoney, D. O. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-006-9239-9 · Cited by 165
Mechanical characterization of brushite and hydroxyapatite cements
Charrière, E., Terrazzoni, S., Pittet, C., Mordasini, P., Dutoit, M., Lemaı̂tre, J., & Zysset, P. (2001) · Biomaterials · doi:10.1016/s0142-9612(01)00041-2 · Cited by 163
Hazelwood, S. J., Martin, R. B., Rashid, M. M., & Rodrigo, J. J. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00221-9 · Cited by 163
“For our study, a relationship between modulus and porosity was obtained by fitting a polynomial to the results of Currey (1988) and Rho et al. (1993), whose data were modified by Turner et al. (1997).”
Mechanical performance of highly permeable laser melted Ti6Al4V bone scaffolds
Arjunan, A., Demetriou, M. D., Baroutaji, A., & Wang, C. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103517 · Cited by 162
Use of porous membranes in tissue barrier and co-culture models
Chung, H. H., Mireles, M., Kwarta, B. J., & Gaborski, T. R. (2018) · Lab on a Chip · doi:10.1039/c7lc01248a · Cited by 161
Materials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 161
Simulation of orthodontic tooth movements: A comparison of numerical models
Bourauel, C. P., Freudenreich, D., Vollmer, D., Kobe, D., Drescher, D., & Jäger, A. (1999) · Journal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie · doi:10.1007/bf01298963 · Cited by 161
Engineering Hydrogel Microenvironments to Recapitulate the Stem Cell Niche
Madl, C. M., & Heilshorn, S. C. (2018) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-062117-120954 · Cited by 160
“Young’s moduli for mammalian tissues range from hundreds of pascals for nervous tissue (11) to tens of gigapascals for calcified bone (12).”
BackgroundTungsten disulfide nanotubes reinforced biodegradable polymers for bone tissue engineering
Lalwani, G., Henslee, A. M., Farshid, B., Parmar, P., Lin, L., Qin, Y., Kasper, F. K., Mikos, A. G., & Sitharaman, B. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.05.018 · Cited by 160
“However, the values of the WSNT nanocomposites are significantly lower than cortical bone (Young’s modulus 12,000–20,000 MPa, compressive yield strength 170– 190 MPa, flexural modulus 5000–23,000 MPa, flexural yield strength 130–295 MPa) [30–33].”
Turner, C. H., Anne, V., & Pidaparti, R. M. V. (1997) · Journal of Biomechanics · doi:10.1016/s0021-9290(97)84505-8 · Cited by 159
Self-citationSurmeneva, M. A., Анатольевич, С. Р., Chudinova, E., Koptioug, A., Tkachev, M. S., Gorodzha, S. N., & Rännar, L. (2017) · Materials & Design · doi:10.1016/j.matdes.2017.07.059 · Cited by 159
Distler, T., Fournier, N., Grünewald, A., Polley, C., Seitz, H., Detsch, R., & Boccaccini, A. R. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00552 · Cited by 158
“5% (wt) BG showed mechanical properties similar to the range of cancellous bone of human proximal tibias (Hvid et al., 1983; Rho et al., 1993).”
Background
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.