Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 401–500 of 1,000
Viscoelasticity of ECM and cells—origin, measurement and correlation
Liu, Z.-Q., Ling, S. D., Liang, K., Chen, Y., Niu, Y., Sun, L., Li, J., & Du, Y. (2024) · Mechanobiology in Medicine · doi:10.1016/j.mbm.2024.100082 · Cited by 34
Li, T., Weng, X., Bian, Y., Zhou, L., Cui, F., & Qiu, Z. (2015) · PLoS ONE · doi:10.1371/journal.pone.0129018 · Cited by 34
“5–12 Rho JY[73] Trabecular 1–20 Kokubo T[42] Cancellous bone 2–12 0.”
BackgroundIn-situ and ex-situ microtensile testing of individual struts of Al foams and Ni/Al hybrid foams
Jung, A., Luksch, J., Diebels, S., Schaefer, F., & Motz, C. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.04.075 · Cited by 34
Hussein, M. A., Azeem, M. A., Kumar, A. M., Saravanan, S., Ankah, N. K., & Sorour, A. A. (2023) · Journal of Materials Research and Technology · doi:10.1016/j.jmrt.2023.03.003 · Cited by 34
Panagiotopoulou, O., Curtis, N., O’Higgins, P., & Cobb, S. N. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.12.027 · Cited by 34
“35 GPa (Ashman et al., 1989; Dalstra et al., 1993; Rho et al., 1993; Zysset et al., 1999).”
BackgroundRetractedLin, Z., Zhao, X., Chen, S., & Du, C. (2017) · Journal of Materials Chemistry B · doi:10.1039/c6tb02156e · Cited by 34
Jeon, I. S., Lee, M. H., Choi, H., Lee, S., Chon, J. W., Chung, D. J., Park, J. H., & Jho, J. Y. (2021) · Polymers · doi:10.3390/polym13121978 · Cited by 34
Fuller, H., Fuller, R., & Pereira, R. M. R. (2015) · Revista Brasileira de Reumatologia (English Edition) · doi:10.1016/j.rbre.2014.07.010 · Cited by 34
NONINVASIVE BONE MINERAL DENSITY MEASUREMENT IN THE EVALUATION OF OSTEOPOROSIS
Hagiwara, S., Yang, S.-O., Glüer, C., Bendavid, E. J., & Genant, H. K. (1994) · Rheumatic Disease Clinics of North America · doi:10.1016/s0889-857x(21)00354-9 · Cited by 34
Hampp, C., Ullmann, B., Reifenrath, J., Angrisani, N., Dziuba, D., Bormann, D., Seitz, J., & Meyer‐Lindenberg, A. (2011) · Advanced Engineering Materials · doi:10.1002/adem.201180066 · Cited by 33
Sadan, D., Raaj, G., Manimaran, P., Kumar, C. D., & Abirami, M. (2019) · Journal of Pharmacy And Bioallied Sciences · doi:10.4103/jpbs.jpbs_29_19 · Cited by 33
“[13] also reported that patients with fractured implants were diagnosed to have para-functional activities.”
Dental implants materials and surface treatments
Najeeb, S., Mali, M., Syed, A. U. Y., Zafar, M. S., Khurshid, Z., Alwadaani, A. H., & Matinlinna, J. P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-08-102476-8.00021-9 · Cited by 33
Amr, M. M., Dykes, I., Counts, M., Kernan, J., Mallah, A. H., Mendenhall, J., Wie, B. V., Abu‐Lail, N. I., & Gozen, B. A. (2021) · Bioprinting · doi:10.1016/j.bprint.2021.e00133 · Cited by 33
Martins, E., Diogo, G. S., Pires, R. A., Reis, R. L., & Silva, T. H. (2022) · Marine Drugs · doi:10.3390/md20110718 · Cited by 33
Wang, Y., Chang, C.-M., Liu, P.-H., & Lin, C. (2023) · Additive manufacturing · doi:10.1016/j.addma.2023.103455 · Cited by 33
Application of Ultrasound Elastography for Chronic Allograft Dysfunction in Kidney Transplantation
Wang, Z., Yang, H., Suo, C., Wei, J., Tan, R., & Gu, M. (2017) · Journal of Ultrasound in Medicine · doi:10.1002/jum.14221 · Cited by 33
“It defines the relationship between stress (force per unit area) and strain (proportional deformation), constituting a ratio of the applied force to the measured intensity (force/intensity).(27,28) In this method, compression and decompression with movement of the kidney can be observed with real-time monitoring, whic…”
MethodEnhanced tendon-to-bone repair through adhesive films
Linderman, S. W., Golman, M., Gardner, T. R., Birman, V., Levine, W. N., Genin, G. M., & Thomopoulos, S. (2018) · Acta Biomaterialia · doi:10.1016/j.actbio.2018.01.032 · Cited by 33
Frank, M., Marx, D., Nedelkovski, V., Fischer, J.-T., Pahr, D. H., & Thurner, P. J. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.07.039 · Cited by 33
Sol-gel bioactive glass-ceramics Part I: Calcium phosphate silicate/wollastonite glass-ceramics
Radev, L., Hristov, V., Mihailova, I., & Samuneva, B. (2009) · Open Chemistry · doi:10.2478/s11532-009-0022-2 · Cited by 33
Soft, Flexible, and Stretchable Platforms for Tissue‐Interfaced Bioelectronics
Yamagishi, K., Lee, S., Yokota, T., & Someya, T. (2026) · Advanced Science · doi:10.1002/advs.202521521 · Cited by 33
“Tooth enamel and bone constitute the stiffest biological tissues: enamel exhibits elastic moduli reaching several tens of GPa and approaching 100 GPa (10 1 1 Pa) [ 37 ], while bone is comparatively softer, with elastic moduli of approximately 10–20 GPa (10 1 0 Pa) [ 38 ].”
Bacterial behavior on coated porous titanium substrates for biomedical applications
Domínguez-Trujillo, C., Beltrán, A. M., Garvi, D., Salazar-Moya, A., Martínez, J. L., Hickey, D. J., Rodríguez-Ortiz, J. A., Kamm, P. H., Lebrato, C., García‐Moreno, F., et al. (2018) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2018.10.098 · Cited by 32
Chen, W., Yang, Q., Huang, S., Kruzic, J. J., & Li, X. (2021) · JOM · doi:10.1007/s11837-021-04938-x · Cited by 32
Buccino, F., Zagra, L., Longo, E., D’Amico, L., Banfi, G., Berto, F., Tromba, G., & Vergani, L. M. (2023) · Materials & Design · doi:10.1016/j.matdes.2023.112087 · Cited by 32
“5), demonstrating that the degeneration in the trabecular groups effectively translates in a degradation of the mechanical characteristics, as mentioned in literature studies [46].”
Advances in conductive hydrogels for neural recording and stimulation
Dawit, H., Zhao, Y., Wang, J., & Pei, R. (2024) · Biomaterials Science · doi:10.1039/d4bm00048j · Cited by 32
Shi, C., Pu, X., Zheng, G., Feng, X., Yang, X., Zhang, B., Zhang, Y., Yin, Q., & Xia, H. (2016) · Scientific Reports · doi:10.1038/srep37418 · Cited by 32
Similar damage initiation but different failure behavior in trabecular and cortical bone tissue
Szabó, M. E., Zekonyte, J., Katsamenis, O. L., Taylor, M., & Thurner, P. J. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.05.036 · Cited by 32
van Rietbergen, B., Kabel, J., Odgaard, A., & Huiskes, R. (1997) · Springer eBooks · doi:10.1007/978-94-009-1471-1_19 · Cited by 32
Gutiérrez, M. I., Penilla, E. H., Leija, L., Vera, A., Garay, J. E., & Aguilar, G. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700214 · Cited by 31
Suzuki, A. K., Campo, K. N., da Fonseca, E. B., Araújo, L. C., Gandra, F. C. G., & Lopes, É. S. N. (2020) · Scientific Reports · doi:10.1038/s41598-020-59247-1 · Cited by 31
Advanced Ti–Nb–Ta Alloys for Bone Implants with Improved Functionality
Saß, J., Sellin, M., Kauertz, E., Johannsen, J., Weinmann, M., Stenzel, M., Frank, M., Vogel, D., Bader, R., & Jonitz‐Heincke, A. (2024) · Journal of Functional Biomaterials · doi:10.3390/jfb15020046 · Cited by 31
“Independent of the orientation in the built chamber, the BSE analysis of Ti–20Nb– 6Ta shows platelet-like features, whereas Ti–27Nb–6Ta and Ti–35Nb–6Ta do not.”
BackgroundGíslason, M. K., Stansfield, B. W., Bransby-Zachary, M., Hems, T., & Nash, D. (2012) · Journal of Hand Surgery (European Volume) · doi:10.1177/1753193412441761 · Cited by 31
“The bones were modelled as having linear elastic mechanical properties with a Young’s modulus of 18 GPa for the cortical shell (Rho et al., 1993) and 100 MPa for the cancellous bone (Kabel et al., 1999).”
BackgroundBaghbani, F., Moztarzadeh, F., Nazari, A. G., Kamran, A. H. R., Tondnevis, F., Nezafati, N., Gholipourmalekabadi, M., & Mozafari, M. (2012) · Advanced Composites Letters · doi:10.1177/096369351202100102 · Cited by 31
Biocomposites: micromechanics of biological hard tissues
Currey, J. D. (1996) · Current Opinion in Solid State and Materials Science · doi:10.1016/s1359-0286(96)80038-6 · Cited by 31
Han, X., Sharma, N., Xu, Z., Krajewski, S., Li, P., Spintzyk, S., Lv, L., Zhou, Y., Thieringer, F. M., & Rupp, F. (2024) · Dental Materials · doi:10.1016/j.dental.2024.02.011 · Cited by 30
Effect of cyclic loading on reverse torque values of angled screw channel systems
Mulla, S. H., Seghi, R. R., Johnston, W. M., & Yılmaz, B. (2021) · Journal of Prosthetic Dentistry · doi:10.1016/j.prosdent.2020.12.020 · Cited by 30
Spitznagel, F. A., Bonfante, E. A., Vollmer, F., & Gierthmuehlen, P. C. (2021) · Journal of Prosthodontics · doi:10.1111/jopr.13369 · Cited by 30
Elastomeric Polyesters in Cardiovascular Tissue Engineering and Organs-on-a-Chip
Okhovatian, S., Shakeri, A., Huyer, L. D., & Radisic, M. (2023) · Biomacromolecules · doi:10.1021/acs.biomac.3c00387 · Cited by 30
Trueba, P., Beltrán, A. M., Bayo, J. M., Rodríguez-Ortiz, J. A., Larios, D. F., Alonso, E., Dunand, D. C., & Torres, Y. (2020) · Metals · doi:10.3390/met10020188 · Cited by 30
“One of the main disadvantages is its excessive stiffness compared to the cortical bone (100‒110 GPa vs 20‒30 GPa, respectively [7]).”
BackgroundA study on the structure and mechanical behavior of the Dasypus novemcinctus shell
Rhee, H., Horstemeyer, M. F., & Ramsay, A. (2010) · Materials Science and Engineering C · doi:10.1016/j.msec.2010.10.012 · Cited by 30
Noninvasive Analysis of Bone Mass, Structure and Strength
Ferretti, J. L., Cointry, G. R., & Capozza, R. F. (2002) · CRC Press eBooks · doi:10.1201/b14228-10 · Cited by 30
Design and Analysis of 3D Customized Models of a Human Mandible
Martorelli, M., Maietta, S., Gloria, A., Santis, R. D., Pei, E., & Lanzotti, A. (2016) · Procedia CIRP · doi:10.1016/j.procir.2015.11.016 · Cited by 29
“In addition, the mechanical anisotropy of trabecular [40-44] and cortical bone [43-46] is also often neglected.”
BackgroundFrank, M., Reisinger, A., Pahr, D. H., & Thurner, P. J. (2021) · JBMR Plus · doi:10.1002/jbm4.10503 · Cited by 29
“74.((13,26,27,42,43)) Reliability of the determined material properties, obtained with the rheological model, has already been found previously for healthy human trabeculae.”
BackgroundAlipour, M., Ghorbani, M., Khatoonabad, M. J., & Aghazadeh, M. (2023) · Scientific Reports · doi:10.1038/s41598-022-23708-6 · Cited by 29
Hatt, L. P., Wirth, S., Ristaniemi, A., Ciric, D., Thompson, K., Eglin, D., Stoddart, M. J., & Armiento, A. R. (2023) · Regenerative Biomaterials · doi:10.1093/rb/rbad084 · Cited by 29
“Natural bone on the other hand has a much higher stiffness compared to the presented scaffolds: trabecular: 10GPa and cortical: 19GPa when tested mechanically [58].”
BackgroundPioneering bone regeneration: A review of cutting-edge scaffolds in tissue engineering
Alex, Y., Vincent, S., Divakaran, N. C., Uthappa, U. T., Srinivasan, P., Mubarak, S., Al-Harthi, M. A., & Dhamodharan, D. (2024) · Bioprinting · doi:10.1016/j.bprint.2024.e00364 · Cited by 30
Kohal, R., Kilian, J., Stampf, S., & Spies, B. C. (2015) · Materials · doi:10.3390/ma8041577 · Cited by 29
“The resin had a modulus of elasticity of approximately 12 GPa which approximates that of human bone (10–18 GPa) [30].”
Hu, E., & Wang, W. (2016) · Mathematical Problems in Engineering · doi:10.1155/2016/6762076 · Cited by 29
“(λ + G)∇θ + G∇ 2 U = ρ ∂ 2 U ∂t(2) , (1)”
BackgroundRETRACTED: Material and regenerative properties of an osteon-mimetic cortical bone-like scaffold
Barati, D., Karaman, O., Moeinzadeh, S., Kader, S. I., & Jabbari, E. (2019) · Regenerative Biomaterials · doi:10.1093/rb/rbz008 · Cited by 29
“Compressive modulus of the scaffold with 240 wt% CaP was close to the reported modulus of natural human cortical bone at 5GPa [39].”
BackgroundRetractedGarimella, A., Awale, G., Parai, R., Ghosh, S. B., & Bandyopadhyay‐Ghosh, S. (2019) · Materials Technology · doi:10.1080/10667857.2019.1639004 · Cited by 29
“based biomaterials have shown promising potential to qualify [14].”
BackgroundThe effect of short-stem humeral component sizing on humeral bone stress
Langohr, G. D. G., Reeves, J. M., Roche, C. P., Faber, K. J., & Johnson, J. A. (2019) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2019.08.018 · Cited by 29
Fabrication and characterization of superficially modified porous dental implants
Trueba, P., Navarro, C., Rodríguez-Ortiz, J. A., Beltrán, A. M., García-García, F. J., & Torres, Y. (2021) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2020.126796 · Cited by 29
Optimal placement of fixation system for scaffold-based mandibular reconstruction
Ferguson, B. M., Entezari, A., Fang, J., & Li, Q. (2021) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2021.104855 · Cited by 29
Aiyangar, A. K., Vivanco, J. F., Au, A. G., Anderson, P. A., Smith, E. L., & Ploeg, H. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027663 · Cited by 29
Microstructure-based finite element modelling and characterisation of bovine trabecular bone
Akhtar, R., Eichhorn, S. J., & Mummery, P. (2006) · Journal of Bionic Engineering · doi:10.1016/s1672-6529(06)60001-2 · Cited by 29
Koolen, M. K. E., Yavari, S. A., Lietaert, K., Wauthlé, R., ZADPOOR, A. A., & Weinans, H. (2020) · Materials · doi:10.3390/ma13081992 · Cited by 28
Malijauskaite, S., Connolly, S. A., Newport, D. T., & McGourty, K. (2021) · Cytokine & Growth Factor Reviews · doi:10.1016/j.cytogfr.2021.03.002 · Cited by 29
A Computational Analysis of the Deformation of the Femoropopliteal Artery With Stenting
Ghriallais, R. N., & Bruzzi, M. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4027329 · Cited by 28
“2 [12].”
Three-dimensional finite element analysis of platform switched implant
Moon, S.-Y., Lim, Y., Kim, M., & Kwon, H. (2017) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2017.9.1.31 · Cited by 28
Flipper bone distribution reveals flexible trailing edge in underwater flying marine tetrapods
DeBlois, M. C., & Motani, R. (2019) · Journal of Morphology · doi:10.1002/jmor.20992 · Cited by 28
“As the presence of bone is stiffer than cartilage, ligaments, or other connective tissue (Mente & Lewis, 1994; Mitton et al., 2014; Pal, 2014; Rho et al., 1993), the sharp decline in propulsive flipper-hydrofoils indicates a relatively more flexible trailing edge.”
BackgroundFailure analysis of composite femoral components for hip arthroplasty
Li, C., Granger, C., Schutte, H. D., Biggers, S. B., Kennedy, J. M., & Latour, R. A. (2003) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2003.03.0133 · Cited by 28
“The maximum and minimum Young’s moduli for each of these regions were then computed from the following equation relating Young’s moduli (E) of cancellous bone to apparent densities (ρ) [24,36,37]:”
MethodKennedy, J., Feerick, E. M., McGarry, P., FitzPatrick, D. P., & Mullett, H. (2013) · Journal of orthopaedic surgery · doi:10.1177/230949901302100210 · Cited by 28
Montgomery, M., Huyer, L. D., Bannerman, D., Mohammadi, M. H., Conant, G., & Radisic, M. (2018) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.7b01017 · Cited by 28
Quantitative ultrasound: Use in the detection of fractures and in the assessment of bone composition
Glüer, C., & Barkmann, R. (2003) · Current Osteoporosis Reports · doi:10.1007/bf02686913 · Cited by 28
van Lenthe, H., van den Bergh, J. P., Hermus, A. R. M. M., & Huiskes, R. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.3.550 · Cited by 28
“(18,19) Using clinical ultrasound scanners, good correlations were found between SOS and the combination of stiffness and apparent density, (12,13) stiffness and the combination of SOS and bone mineral density (BMD),((20)) or SOS and the combination of stiffness and BMD.”
MethodHasegawa, A., Shinya, A., Nakasone, Y., Lassila, L. V. J., Vallittu, P. K., & Shinya, A. (2010) · International Journal of Biomaterials · doi:10.1155/2010/659802 · Cited by 27
“A total of 460 images were obtained, and the image data were saved as files in DICOM (medical imaging standard) format.”
MethodGarcia-Brand, A. J., Morales, M. A., Hozman-Manrique, A. S., Ramirez, A. C., Cruz, L. J., Marañón, A., Muñoz-Camargo, C., Cruz, J. C., & Porras, A. (2021) · Polymers · doi:10.3390/polym13213707 · Cited by 27
“PLA/CBS composites behavior seems to exhibit mechanical properties that resemble those of human trabecular bone [73], which are also comparable with those of commonly used PLA composite biomaterials, such as PLA/Chitosan [74] and PLA/Hydroxyapatite [75].”
ResultNovel bioactive Ti-Zn alloys with high strength and low modulus for biomedical applications
Qi, M. H., Xu, J. L., Lai, T., Huang, J., Ma, Y. C., Luo, J., & Zheng, Y. (2022) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2022.167555 · Cited by 27
Xiang, T., Chen, J., Bao, W., Zhong, S., Du, P., & Xie, G. (2023) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2023.05.039 · Cited by 27
Shadanbaz, S., Walker, J., Staiger, M. P., Dias, G. J., & Pietak, A. M. (2012) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.32830 · Cited by 27
Structure and micro-computed tomography-based finite element modeling of Toucan beak
Seki, Y., Mackey, M. R., & Meyers, M. A. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.08.003 · Cited by 27
“(Borah et al., 2001; Ulrich et al., 1998; Rietbergen et al., 1995; Nagaraja et al., 2004) to microscopically analyze the human trabecular bone through FEA.”
BackgroundDevelopment of a novel TiNbTa material potentially suitable for bone replacement implants
Chicardi, E., Gutiérrez-González, C. F., Sayagués, M. J., & García-Garrido, C. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.02.042 · Cited by 27
Improved response of osteoprogenitor cells to titanium plasma-sprayed PEEK surfaces
Hickey, D. J., Lorman, B., & Fedder, I. L. (2018) · Colloids and Surfaces B Biointerfaces · doi:10.1016/j.colsurfb.2018.12.037 · Cited by 27
Azzouz, I., Fauré, J., Khlifi, K., Larbi, A. B. C., & Benhayoune, H. (2020) · Coatings · doi:10.3390/coatings10121192 · Cited by 27
Luz, A. R., de Lima, G. G., Santos, E., Pereira, B. L., Sato, H. H., Lepienski, C. M., de Lima, D. B., Laurindo, C. A. H., Grandini, C. R., & Kuromoto, N. K. (2018) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2018.11.192 · Cited by 27
Finite element analysis in vertebrate palaeontology
Fastnacht, M., Hess, N., Frey, E. D., & Weiser, H.-P. (2002) · Senckenbergiana lethaea · doi:10.1007/bf03043784 · Cited by 27
Exploiting Matrix Stiffness to Overcome Drug Resistance
Aydın, H. B., Özçelikkale, A., & Acar, A. (2024) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.4c00445 · Cited by 27
“125 The stiffness of a TME is an emerging research area since much recent literature shows that the stiffness of a micro-environment is directly related to the hallmarks of cancer.”
BackgroundSenatov, F. S., Chubrik, A., Maksimkin, A. V., Kolesnikov, E. A., & Salimon, A. I. (2018) · Materials Letters · doi:10.1016/j.matlet.2018.12.055 · Cited by 26
Rational engineering and applications of functional bioadhesives in biomedical engineering
Park, J., Kim, Y., Chun, B., & Seo, J. (2021) · Biotechnology Journal · doi:10.1002/biot.202100231 · Cited by 26
“[18] Furthermore, elastic modulus of more than 104 Pa is required for cartilage and muscle tissues, whereas approximately 109 Pa of elastic modulus is required for bone tissues.[19] Cohesive force modulating methods depend on the type of bioadhesive.”
BackgroundCurrent Methods in the Study of Nanomaterials for Bone Regeneration
Tanaka, M., Izumiya, M., Haniu, H., Ueda, K., Ma, C., Ueshiba, K., Ideta, H., Sobajima, A., Uchiyama, S., Takahashi, J. A., et al. (2022) · Nanomaterials · doi:10.3390/nano12071195 · Cited by 26
“Bone has a high Young’s modulus (E = 18.6 GPa [24]) and is one of the hardest load-bearing tissues in the human body.”
BackgroundInfluentialPredicting fracture in the proximal humerus using phase field models
Hug, L., Dahan, G., Kollmannsberger, S., Rank, E., & Yosibash, Z. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105415 · Cited by 26
“The base values are set to G c 0 = 7 N/mm [48] and E 0 = 20000 MPa based on different studies on the Young’s modulus of human cortical bone [22, 36, 55].”
MethodFärber, E., Orlov, A. V., Borisov, E. V., Repnin, A., Kuzin, S. A., Golubkov, N., & Popovich, A. (2022) · Metals · doi:10.3390/met12091476 · Cited by 26
Qin, W., Xing, T., Tang, B. H., & Chen, W. (2023) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2023.106222 · Cited by 26
The effect of heterobifunctional crosslinkers on HEMA hydrogel modulus and toughness
Boazak, E. M., Greene, V. K., & Auguste, D. T. (2019) · PLoS ONE · doi:10.1371/journal.pone.0215895 · Cited by 26
Wang, L., Shi, Q., Cai, Y., Chen, Q., Guo, X., & Li, Z. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01339-y · Cited by 26
Finite element analysis of a micromechanical model of bone and a new 3D approach to validation
Evans, S. P., Parr, W. C. H., Clausen, P. D., Jones, A. S., & Wroe, S. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.08.003 · Cited by 26
IN VITROACOUSTIC WAVE PROPAGATION IN HUMAN AND BOVINE CANCELLOUS BONE AS PREDICTED BY BIOT'S THEORY
Cardoso, L., MEUNIER, A., & Oddou, C. (2008) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519408002565 · Cited by 26
Srinivasan, S. S., de Andrade, J. R., Biggers, S. B., & Latour, R. A. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00053-3 · Cited by 26
“30 [20].”
Bone material ultrasound velocity is predictive of whole bone strength
Mehta, S. S., Antich, P. P., Daphtary, M. M., Bronson, D. G., & Richer, E. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00385-4 · Cited by 26
Effect of initial preform porosity on solid-state foaming of titanium
Murray, N. G. D., & Dunand, D. C. (2006) · Journal of materials research/Pratt's guide to venture capital sources · doi:10.1557/jmr.2006.0140 · Cited by 26
Collins, C. J., Andriotis, O. G., Nedelkovski, V., Frank, M., Katsamenis, O. L., & Thurner, P. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99937-9 · Cited by 26
Tooth Cementum Annulation: A Literature Review
Perrone, V., Gocha, T. P., Randolph-Quinney, P. S., & Procopio, N. (2022) · Forensic Sciences · doi:10.3390/forensicsci2030038 · Cited by 25
The Modified Maquet Procedure (MMP) in Dogs: Technical Development and Initial Clinical Experience
Ness, M. G. (2016) · Journal of the American Animal Hospital Association · doi:10.5326/jaaha-ms-6304 · Cited by 25
Katz, A. M. J. L., Misra, A., Marangos, O., Ye, Q., & Spencer, P. (2014) · CRC Press eBooks · doi:10.1201/b15482-13 · Cited by 25
Chen, Y.-N., Chang, C.-W., Lin, C.-W., Wang, C., Peng, Y.-T., Chang, C., & Li, C. (2017) · International Orthopaedics · doi:10.1007/s00264-017-3401-x · Cited by 25
“Bone quality (normal and poor) was defined according to the literature [35, 36] and is shown in Table 1.”
MethodCustomizable cap implants for neurophysiological experimentation
Blonde, J. D., Roussy, M. P., Luna, R., Mahmoudian, B., Gulli, R. A., Barker, K. C., Lau, J. C., & Martínez-Trujillo, J. (2018) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2018.04.016 · Cited by 25
Troy, K. L., Davis, I. S., & Tenforde, A. S. (2021) · PM&R · doi:10.1002/pmrj.12518 · Cited by 25
Indentation Modulus of the Alveolar Process in Dogs
Huja, S. S., Fernandez, S. A., Hill, K. J., & Gulati, P. (2007) · Journal of Dental Research · doi:10.1177/154405910708600308 · Cited by 25
“Other methods to estimate the material properties of small volumes of tissue include scanning acoustic microscopy (Bumrerraj and Katz, 2001) and micro-testing of bone specimens (Rho et al., 1993).”
MethodArchitecture of the sperm whale forehead facilitates ramming combat
Panagiotopoulou, O., Spyridis, P., Abraha, H. M., Carrier, D. R., & Pataky, T. C. (2016) · PeerJ · doi:10.7717/peerj.1895 · Cited by 25
Han, T., Chang, B., Ding, X., Yue, G.-N., Song, W., Tang, H., Liang, J., Zhao, L., & Zhang, Y. (2016) · RSC Advances · doi:10.1039/c5ra20370h · Cited by 25
Chicardi, E., García-Garrido, C., Sayagués, M. J., Torres, Y., Amigó, V., & Aguilar, C. (2017) · Materials Characterization · doi:10.1016/j.matchar.2017.11.021 · Cited by 25
“The excessive difference between the Young’s modulus (E) of Ti and the first generation Ti alloys (110-140 GPa) in comparison with the human bones (21–18 GPa for cortical and 15–10 GPa for trabecular bones [9, 10]) results in bone resorption and eventual loosening of the implants [11], known this problem as stress-shi…”
Background
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.