Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 201–300 of 1,000
Guiñón-Pina, V., Amigó, V., & Muñoz, A. N. I. (2016) · Corrosion Science · doi:10.1016/j.corsci.2016.02.014 · Cited by 83
Stress-based performance evaluation of osseointegrated dental implants by finite-element simulation
Baggi, L., Cappelloni, I., Maceri, F., & Vairo, G. (2008) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2008.05.009 · Cited by 82
“[48], three values for Et are also employed: 0.”
BackgroundMethodMadeo, A., Lekszycki, T., & dell’Isola, F. (2011) · Comptes Rendus Mécanique · doi:10.1016/j.crme.2011.07.004 · Cited by 81
“in [38]).”
Jung, M., Ghamrawi, S., Du, E. Y., Gooding, J. J., & Kavallaris, M. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202200690 · Cited by 82
Advances in the Translation of Electrochemical Hydrogel‐Based Sensors
Shafique, H., de Vries, J., Strauss, J., Jahromi, A. K., Moakhar, R. S., & Mahshid, S. (2022) · Advanced Healthcare Materials · doi:10.1002/adhm.202201501 · Cited by 82
Fatigue induced changes in conical implant–abutment connections
Blum, K.-U., Wiest, W., Fella, C., Balles, A., Graetz, J., Rack, A., Maier, D., Thomann, R., Spies, B. C., Kohal, R., et al. (2015) · Dental Materials · doi:10.1016/j.dental.2015.09.004 · Cited by 81
“[34] Rho JY, Ashman RB, Turner CH.”
MethodCox, L. G. E., van Donkelaar, C. C., van Rietbergen, B., Emans, P. J., & Ito, K. (2012) · Bone · doi:10.1016/j.bone.2012.01.024 · Cited by 81
Shahin‐Shamsabadi, A., Hashemi, A., Tahriri, M., Bastami, F., Salehi, M., & Abbas, F. M. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.04.080 · Cited by 81
The estimated elastic constants for a single bone osteonal lamella
Yoon, Y. J., & Cowin, S. C. (2008) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-006-0072-8 · Cited by 80
“Even though there are many reports for the bone matrix elastic constants (Akiva et al. 1997, 1998; Bonfield and Li 1966; Crolet et al. 1993; Currey 1964; Fan et al. 2002; HellmichandUlm2002;Hellmichetal.2004;Katz1971; Piekarski 1973; Rho et al. 1993, 1997, 1999a, b,c, 2002; Sasaki et al. 1991; Swandener et al. 2001; W…”
BackgroundMethodInfluentialMicrotensile measurements of single trabeculae stiffness in human femur
Bini, F., Marinozzi, A., Marinozzi, F., & Patanè, F. G. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00182-3 · Cited by 80
Continuous fibre reinforced polymers as connective tissue replacement
Santis, R. D., Sarracino, F., Mollica, F., Netti, P. A., Ambrosio, L., & Nicolais, L. (2003) · Composites Science and Technology · doi:10.1016/j.compscitech.2003.09.008 · Cited by 80
Brennan, O., Kennedy, O. D., Lee, T. C., Rackard, S. M., & O’Brien, F. J. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2008.11.032 · Cited by 66
“Since then, numerous measurements of the elastic modulus of individual trabeculae have been reported (Kuhn et al., 1989; Mente and Lewis, 1989; Ryan and Williams, 1989; Choi et al., 1990; Rho et al., 1993; Bini et al., 2002; McNamara et al., 2006).”
BackgroundEffect of Mechanical Set Point of Bone Cells on Mechanical Control of Trabecular Bone Architecture
Mullender, M. G., van Rietbergen, B., Ruegsegger, P., & Huiskes, R. (1998) · Bone · doi:10.1016/s8756-3282(97)00251-2 · Cited by 80
Benne, N., Leboux, R., Glandrup, M., van Duijn, J., Vigario, F. L., Neustrup, M. A., Romeijn, S. G., Galli, F., Kuiper, J., Jiskoot, W., et al. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.12.003 · Cited by 79
“For comparison, the YM of most mammalian cells was measured to be between 0.02 and 400 kPa [49] and that of cortical bone was reported to be about 20 GPa [50].”
BackgroundInfluentialMishra, S. K., & Kannan, S. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.08.014 · Cited by 79
Effects of implant threads on the contact area and stress distribution of marginal bone
Lee, C.-C., Lin, S., Kang, M.-J., Wu, S.-W., & Fu, P.-Y. (2010) · Journal of Dental Sciences · doi:10.1016/s1991-7902(10)60023-2 · Cited by 79
The Effects of Dietary Boron on Bone Strength in Rats
Chapin, R. E., Ku, W. W., Kenney, M. A., McCoy, H., Gladen, B. C., Wine, R. N., Wilson, R. E., & Elwell, M. R. (1997) · Fundamental and Applied Toxicology · doi:10.1006/faat.1996.2275 · Cited by 79
“bone is not on a continuum with trabecular bone, affirming that they are distinctly different kinds of bone ( Rho et al., 1993 ).”
BackgroundElectroresponsive Alginate-Based Hydrogels for Controlled Release of Hydrophobic Drugs
Puiggalí‐Jou, A., Cazorla, E., Ruano, G., Babeli, I., Ginebra, M., García‐Torres, J., & Alemán, C. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01400 · Cited by 79
Hellmich, C., & Ulm, F. (2005) · Transport in Porous Media · doi:10.1007/s11242-004-6298-y · Cited by 80
On the Relation of Bone Mineral Density and the Elastic Modulus in Healthy and Pathologic Bone
Nobakhti, S., & Shefelbine, S. J. (2018) · Current Osteoporosis Reports · doi:10.1007/s11914-018-0449-5 · Cited by 78
Duan, Y., Gonzalez, J. A., Kulkarni, P. A., Nagy, W. W., & Griggs, J. A. (2018) · Dental Materials · doi:10.1016/j.dental.2018.06.002 · Cited by 78
Design, processing and characterization of titanium with radial graded porosity for bone implants
Torres, Y., Trueba, P., Pavón, J. J., Chicardi, E., Kamm, P. H., García‐Moreno, F., & Rodríguez-Ortiz, J. A. (2016) · Materials & Design · doi:10.1016/j.matdes.2016.07.135 · Cited by 77
Ultrasound Bone Densitometry of the Os Calcis in Children and Adolescents
Wünsche, K., Wünsche, B., Fähnrich, H., Mentzel, H., Vogt, S., Abendroth, K., & Kaiser, W. A. (2000) · Calcified Tissue International · doi:10.1007/s002230001143 · Cited by 77
Computational simulation of internal bone remodeling
Pettermann, H. E., Reiter, T. J., & Rammerstorfer, F. G. (1997) · Archives of Computational Methods in Engineering · doi:10.1007/bf02737117 · Cited by 77
Phenylalanine-Based Poly(ester urea): Synthesis, Characterization, and in vitro Degradation
Yu, J., Lin, F., Lin, P., Gao, Y., & Becker, M. L. (2014) · Macromolecules · doi:10.1021/ma401752b · Cited by 60
Dynamic modelling and simulation of dental implant insertion process—A finite element study
Guan, H., van Staden, R., Johnson, N. W., & Loo, Y. (2011) · Finite Elements in Analysis and Design · doi:10.1016/j.finel.2011.03.005 · Cited by 76
Canine Cranial Reconstruction Using Autologous Bone Marrow Stromal Cells
Mankani, M. H., Kuznetsov, S. A., Shannon, B., Nalla, R. K., Ritchie, R. O., Qin, Y., & Robey, P. G. (2006) · American Journal Of Pathology · doi:10.2353/ajpath.2006.050407 · Cited by 76
Boruah, S., Subit, D. L., Paskoff, G. R., Shender, B. S., Crandall, J. R., & Salzar, R. S. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.09.041 · Cited by 76
“As pointed out by Rho et al. (1993), the modulus measured using ultrasound is greater by more than 10% compared to estimates using tensile tests.”
BackgroundResultAlkentar, R., Kladovasilakis, N., Tzetzis, D., & Mankovits, T. (2023) · Crystals · doi:10.3390/cryst13010113 · Cited by 75
Medical applications of the intrinsic mechanical properties of single cells
Quan, F., & Kim, K. S. (2016) · Acta Biochimica et Biophysica Sinica · doi:10.1093/abbs/gmw081 · Cited by 75
Zhang, G., Yuan, H., Chen, X., Wang, W., Chen, J., Liang, J., & Zhang, P. (2016) · International Journal of Dentistry · doi:10.1155/2016/4867402 · Cited by 74
“30 56 [23]”
Machining-induced thermal damage in cortical bone: Necrosis and micro-mechanical integrity
Robles-Linares, J. A., Axinte, D. A., Liao, Z., & Gameros, A. A. (2020) · Materials & Design · doi:10.1016/j.matdes.2020.109215 · Cited by 73
“Micro-mechanical testing of bone has been employed since the 1980s with the aim of mapping the elastic properties [25,26] of its different constituents (e.”
BackgroundFu, Q., Gabriel, M., Schmidt, F., Müller, W., & Schwitalla, A. D. (2020) · Dental Materials · doi:10.1016/j.dental.2020.09.020 · Cited by 72
Experimental Techniques for Bone Mechanics
Cowin, S. C. (2001) · CRC Press eBooks · doi:10.1201/b14263-12 · Cited by 72
Occlusal forces and mandibular bone strain: Is the primate jaw “overdesigned”?
Daegling, D. J., & Hylander, W. L. (1997) · Journal of Human Evolution · doi:10.1006/jhev.1997.0164 · Cited by 71
“This is so due to the different elastic moduli of the two tissues (Ashman & Rho, 1988; Rho et al., 1993).”
BackgroundCurrent methods and advances in bone densitometry
Guglielmi, G., Gl�er, C. C., Majumdar, S., Blunt, B. A., & Genant, H. K. (1995) · European Radiology · doi:10.1007/bf00957107 · Cited by 71
“Moreover, Young's modulus of trabecular and cortical bone can be assessed [93].”
BackgroundA comparative study on complete and implant retained denture treatments – A biomechanics perspective
Chen, J., Ahmad, R., Suenaga, H., Li, W., Swain, M. V., & Li, Q. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.11.043 · Cited by 70
Understanding the structure–property relationship in cortical bone to design a biomimetic composite
Libonati, F., & Vergani, L. M. (2015) · Composite Structures · doi:10.1016/j.compstruct.2015.12.003 · Cited by 71
“At macroscale, conventional testing [2–4,6,7,9,10,16,25–29], but also ultrasounds [12,30] have been used to characterize cortical and trabecular tissues, showing a clear anisotropy of bone; At microscale, Ascenzi and co-workers [31–35] have largely examined the anisotropic mechanical properties of single osteons by ex…”
BackgroundMultilayer porous UHMWPE scaffolds for bone defects replacement
Maksimkin, A. V., Senatov, F. S., Anisimova, N. Y., Kiselevskiy, M. V., Zalepugin, D. Y., Chernyshova, I. V., Tilkunova, N. A., & Kaloshkin, S. D. (2016) · Materials Science and Engineering C · doi:10.1016/j.msec.2016.12.104 · Cited by 70
Computational Foot Modeling: Scope and Applications
Orcajo, E. M., Bayod, J., & Casas, E. B. D. L. (2015) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-015-9146-z · Cited by 70
Elucidating the corrosion-related degradation mechanisms of a Ti-6Al-4V dental implant
Chen, X., Shah, K. C., Dong, S., Peterson, L., Plante, E. C. L., & Sant, G. (2020) · Dental Materials · doi:10.1016/j.dental.2020.01.008 · Cited by 69
Uth, N., Mueller, J., Smucker, B. J., & Yousefi, A. (2017) · Biofabrication · doi:10.1088/1758-5090/9/1/015023 · Cited by 68
“On the other hand, nHA is a ceramic with a high modulus (E=35–120 GPa for dense ceramics [25, 26]) that has been suggested to encourage osteogenesis [4].”
InfluentialPeters, A. E., Akhtar, R., Comerford, E. J., & Bates, K. T. (2018) · PeerJ · doi:10.7717/peerj.4298 · Cited by 68
In vitro evaluation of electrochemically bioactivated Ti6Al4V 3D porous scaffolds
Myakinin, A., Turlybekuly, A., Pogrebnjak, A. D., Mirek, A., Bechelany, M., Liubchak, I., Oleshko, O., Husak, Y., Korniienko, V. V., Leśniak–Ziółkowska, K., et al. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.111870 · Cited by 68
3 How can we measure bone quality?
Hans, D., Fuerst, T. P., Lang, T., Majumdar, S., Lü, Y., Genant, H. K., & Glüer, C. (1997) · Baillière s Clinical Rheumatology · doi:10.1016/s0950-3579(97)80017-9 · Cited by 68
Quantitative ultrasound bone measurement
Hans, D., Fuerst, T. P., & Duboeuf, F. (1997) · European Radiology · doi:10.1007/pl00006863 · Cited by 68
Wanniarachchi, C. T., Arjunan, A., Baroutaji, A., & Singh, M. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105409 · Cited by 67
Zhang, Y., Wang, B., Zhou, C., Atungulu, G. G., Xu, K., Ma, H., Ye, X. P., & Abdualrahman, M. A. Y. (2015) · Ultrasonics Sonochemistry · doi:10.1016/j.ultsonch.2015.11.010 · Cited by 67
Bevill, G. R., Eswaran, S. K., Farahmand, F., & Keaveny, T. M. (2008) · Bone · doi:10.1016/j.bone.2008.11.015 · Cited by 67
“Many techniques have been used to directly measure trabecular tissue properties including tensile testing [8], compressive buckling [9], bending [10], and nanoindentation [11] (see [12] for a comprehensive review of these techniques).”
Poly-Ether-Ether-Ketone (PEEK) Biomaterials and Composites: Challenges, Progress, and Opportunities
Molinar‐Díaz, J., Parsons, A. J., Ahmed, I., Warrior, N. A., & Harper, L. T. (2024) · Journal of macromolecular science. Part C, Reviews in macromolecular chemistry and physics/Journal of macromolecular science. Reviews in macromolecular chemistry and physics · doi:10.1080/15583724.2024.2406965 · Cited by 66
Muiznieks, L. D., & Keeley, F. W. (2016) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00469 · Cited by 65
Lin, C., Kuo, Y.-C., & LIN, T. ‐. (2005) · Biomedical Engineering Applications Basis and Communications · doi:10.4015/s1016237205000081 · Cited by 64
“has since been accepted by clinicians and scientists as the standard criterion in evaluating patients for implant placement [2, 9-11].”
BackgroundDolgin, J., Hanumantharao, S. N., Farias, S. L., Simon, C. G., & Rao, S. (2023) · Fibers · doi:10.3390/fib11050039 · Cited by 64
“6 GPa, a stiff microenvironment will promote osteogenesis over a less stiff one with other properties held constant [175].”
BackgroundEnhancement of CRF-PEEK osseointegration by plasma-sprayed hydroxyapatite: A rabbit model
Suska, F., Omar, O., Emanuelsson, L., Taylor, M., Gruner, P. J., Kinbrum, A., Hunt, D., Hunt, T., Taylor, A., & Palmquist, A. (2014) · Journal of Biomaterials Applications · doi:10.1177/0885328214521669 · Cited by 63
“Young’s modulus for trabecular bone is 10–15GPa, while it is 19–21GPa for cortical bone.(17) Reduced bone resorption has previously been demonstrated in response to CFR-PEEK with elasticity similar to that of cortical bone.”
BackgroundVance, A., Bari, K., & Arjunan, A. (2018) · Materials & Design · doi:10.1016/j.matdes.2018.11.005 · Cited by 63
Comparison of measurements of phase velocity in human calcaneus to Biot theory
Wear, K. A., Laib, A., Stuber, A. P., & Reynolds, J. C. (2005) · The Journal of the Acoustical Society of America · doi:10.1121/1.1886388 · Cited by 63
“Rho et al. (1993) pointed out that the range of measurements of Young’s modulus for human trabecular bone material measured by bending tests is 3.2 – 7.8 GPa while that measured by buckling and ultrasound is 8.7 – 12.7 GPa.”
BackgroundInfluentialAssessing biocompatibility & mechanical testing of 3D-printed PEEK versus milled PEEK
Limaye, N., Veschini, L., & Coward, T. J. (2022) · Heliyon · doi:10.1016/j.heliyon.2022.e12314 · Cited by 62
Tarallo, L., Mugnai, R., Adani, R., Zambianchi, F., & Catani, F. (2014) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-014-0311-1 · Cited by 62
“Typically, metals used in orthopedic surgery have a large elastic modulus (approximately 6–20 times greater than that of the surrounding bone) [23–25], causing impaired load force transmission at the implant–tissue interface.”
Application of the multiscale FEM to the modeling of cancellous bone
Ilić, S., Hackl, K., & Gilbert, R. P. (2009) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-009-0161-6 · Cited by 62
Karre, R., Kumar, K. B., Rajendran, A., Nivedhitha, J., Pattanayak, D. K., Ameyama, K., & Dey, S. R. (2018) · Materials Science and Engineering C · doi:10.1016/j.msec.2018.10.006 · Cited by 62
On the potential of ultrasound elastography for pressure ulcer early detection
Deprez, J.-F., Brusseau, É., Fromageau, J., Cloutier, G., & Basset, O. (2011) · Medical Physics · doi:10.1118/1.3560421 · Cited by 62
Kohles, S. S., & Roberts, J. B. (2002) · Journal of Biomechanical Engineering · doi:10.1115/1.1503374 · Cited by 62
Weisgerber, D. W., Erning, K., Flanagan, C. L., Hollister, S. J., & Harley, B. A. C. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.03.032 · Cited by 61
A morphological model of vertebral trabecular bone
Kim, H. S., & Al-Hassani, S. T. S. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00053-2 · Cited by 61
“Recently, ultrasonic techniques have been used to characterise trabecular bone material (Ashman and Rho, 1988; Rho et al., 1993; Shieh et al., 1995).”
BackgroundMethodAnisotropic mechanical properties of lamellar bone using miniature cantilever bending specimens
Liu, D., Weiner, S., & Wagner, H. D. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00051-2 · Cited by 62
Evolution of implants and advancements for osseointegration: A narrative review
Walter, N., Stich, T., Docheva, D., Alt, V., & Rupp, M. (2022) · Injury · doi:10.1016/j.injury.2022.05.057 · Cited by 59
Effect of milling time on powder characteristics and mechanical performance of Ti4wt%Al alloy
Singh, P. K., Abhash, A., Yadav, B. N., Muhamed Shafeeq, M., Singh, I. B., & Mondal, D. P. (2018) · Powder Technology · doi:10.1016/j.powtec.2018.09.075 · Cited by 59
Review Micromechanical testing of bone trabeculae - potentials and limitations
Lucchinetti, E., Thomann, D., & Danuser, G. M. (2000) · Journal of Materials Science · doi:10.1023/a:1026748913553 · Cited by 59
Single-trabecula building block for large-scale finite element models of cancellous bone
Dagan, D., Be'ery, M., & Gefen, A. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02350998 · Cited by 59
“It was assumed that the tissue contained in each trabecula building block was a homogenous, isotropic and linear elastic material, with elastic modulus of 10GPa and Poisson’s ratio of 0.3 (TOWNSEND et al., 1975; RHO et al., 1993;WERNER et al., 1996).”
BackgroundInfluentialFracture resistance of zirconia-based implant abutments after artificial long-term aging
Alsahhaf, A., Spies, B. C., Vach, K., & Kohal, R. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.11.018 · Cited by 58
Grassi, L., Väänänen, S. P., Ristinmaa, M., Jurvelin, J. S., & Isaksson, H. (2016) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-016-0866-2 · Cited by 58
“2004), while the minimum modulus of elasticity for the surface elements was set to 5 GPa [assuming very thin cortex and consequently a Young’s modulus corresponding to that of the underlying trabecular bone (Rho et al. 1993)].”
BackgroundHan, S., Hyun, S.-J., Kim, K.-J., Jahng, T.-A., & Kim, H.-J. (2017) · World Neurosurgery · doi:10.1016/j.wneu.2017.04.031 · Cited by 58
Cancer invasion into musculature: Mechanics, molecules and implications
Beunk, L., Brown, K., Nagtegaal, I. D., Friedl, P., & Wolf, K. (2018) · Seminars in Cell and Developmental Biology · doi:10.1016/j.semcdb.2018.07.014 · Cited by 59
Numerical modelling of the mechanical behaviour of an osteon with microcracks
Giner, E., Arango, C., Vercher-Martínez, A., & Fuenmayor, F. J. (2014) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2014.05.006 · Cited by 56
Personalizing Biomaterials for Precision Nanomedicine Considering the Local Tissue Microenvironment
Oliva, N., Unterman, S. A., Zhang, Y., Conde, J., Song, H. S., & Artzi, N. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400778 · Cited by 57
Chen, W., Yang, J., Kong, H., Helou, M., Zhang, D., Zhao, J., Jia, W., Liu, Q., He, P., & Li, X. (2021) · Materials Science and Engineering C · doi:10.1016/j.msec.2021.112461 · Cited by 56
Damiati, L. A., Tsimbouri, M. P., Llopis-Hernández, V., Jayawarna, V., Ginty, M., Childs, P. G., Xiao, Y., Burgess, K. E., Wells, J. A., Sprott, M. R., et al. (2021) · Biomaterials · doi:10.1016/j.biomaterials.2021.121263 · Cited by 56
The Bone Organ System: Form and Function
Morgan, E. F., Barnes, G. B., & Einhorn, T. A. (2008) · Elsevier eBooks · doi:10.1016/b978-012370544-0.50003-3 · Cited by 81
Viswanath, A., Khan, K. A., & Barsoum, I. (2022) · Materials & Design · doi:10.1016/j.matdes.2022.111293 · Cited by 55
Site-Specific Quantification of Bone Quality Using Highly Nonlinear Solitary Waves
Yang, J., Sangiorgio, S. N., Borkowski, S. L., Silvestro, C., Nardo, L. D., Daraio, C., & Ebramzadeh, E. (2012) · Journal of Biomechanical Engineering · doi:10.1115/1.4007364 · Cited by 55
“heavily studied in the literature. For cortical bone, wide ranges of Young’s modulus have been reported, with values of as low as 0.69 GPa along the femoral shaft [26], to values greater than 20 GPa [27, 28, 29, 30]. Similarly, trabecular bone also shows a wide range, with Young’s modulus values from 0.49 GPa to almos…”
BackgroundInfluentialFuller, H., Fuller, R., & Pereira, R. M. R. (2014) · Revista Brasileira de Reumatologia · doi:10.1016/j.rbr.2014.07.010 · Cited by 55
Saghaian, S. E., Amerinatanzi, A., Moghaddam, N. S., Majumdar, A., Nematollahi, M., Saedi, S., Elahinia, M., & Karaca, H. E. (2018) · Biology Engineering and Medicine · doi:10.15761/bem.1000152 · Cited by 55
Yan, L., Lim, J. L., Lee, J. W., Tia, C. S. H., O’Neill, G. K., & Chong, D. Y. R. (2020) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-019-02104-9 · Cited by 55
Biomechanical background for a noninvasive assessment of bone strength and muscle-bone interactions.
Cointry, G. R., Capozza, R. F., Negri, A. L., Ej, R., & Ferretti, J. L. (2004) · PubMed · Cited by 55
Awadly, T. A. E., Radi, I. A.-E., ElKhadem, A. H., & Osman, R. B. (2017) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-17-00144 · Cited by 55
“A modulus of elasticity that is close to that of bone will optimize the biomechanical load distribution between implant and surrounding bone and maintain bone implant contact (BIC).(10) Titanium alloys have a modulus of elasticity of 110 GPa compared to 3–4 GPa for natural unfilled PEEK.”
BackgroundCarretta, R., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2013.04.014 · Cited by 54
Ultrasonic determination of the elastic modulus of human cortical bone
Hunt, K. D., O’Loughlin, V. D., Fitting, D. W., & Adler, L. (1998) · Medical & Biological Engineering & Computing · doi:10.1007/bf02522857 · Cited by 54
“To remedy these biases, a number of investigators have examined the elastic modulus in human bone using ultrasonic methods (ABENDSCHEIN and HYATT, 1970; YOON and KATZ, 1976a,b; ASHMAN et al., 1984; RHO et al., 1993).”
MethodCharles, L. F., Shaw, M. T., Olson, J. R., & Wei, M. (2010) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-010-4051-3 · Cited by 54
“For instance, the modulus of trabecular bone ranges from 1 to 14 GPa [6–13].”
Comparison of Electrochemical Methods for the Evaluation of Cast AZ91 Magnesium Alloy
Tkácz, J., Minda, J., Fintová, S., & Wasserbauer, J. (2016) · Materials · doi:10.3390/ma9110925 · Cited by 54
Boccaccio, A., Fiorentino, M., Uva, A. E., Laghetti, L. N., & Monno, G. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.09.004 · Cited by 54
Kassanos, D., Trakakis, E., Baltas, C. S., Papakonstantinou, O., Simeonidis, G., Salamalekis, G., Grammatikakis, I., Basios, G., Labos, G., Skarantavos, G., et al. (2010) · Human Reproduction · doi:10.1093/humrep/deq149 · Cited by 52
Indentation Properties of Young and Old Osteons
Huja, S. S., Beck, F. M., & Thurman, D. (2006) · Calcified Tissue International · doi:10.1007/s00223-006-0025-3 · Cited by 54
“properties of small volumes of tissue include scanning acoustic microscopy [22, 23] and microtesting of bone specimens [24].”
BackgroundBadar, M., Lünsdorf, H., Evertz, F., Rahim, M. I., Glasmacher, B., Häuser, H., & Mueller, P. P. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.03.012 · Cited by 53
“In bone repair magnesium-based implants could help to reduce bone loss due to stress shielding effects that are associated with current permanent materials [4, 8-10].”
Engineering clinically relevant volumes of vascularized bone
Roux, B. M., Cheng, M., & Brey, E. M. (2015) · Journal of Cellular and Molecular Medicine · doi:10.1111/jcmm.12569 · Cited by 53
“The elastic moduli of native trabecular and cortical bone are approximately 10–15 and 18–20 GPa, respectively [34].”
BackgroundSilk fibroin scaffolds with inverse opal structure for bone tissue engineering
Sommer, M., Vetsch, J. R., Leemann, J., Müller, R., Studart, A. R., & Hofmann, S. (2016) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33737 · Cited by 53
“Ideally, at least in an approach mimicking the physiological tissue, it should lie in the range of 10 to 20 GPa, which is the elastic modulus of bone.(32) However, cells likely probe and respond to the local pore wall stiffness rather than the scaffold modulus.”
BackgroundMorgan, E. F., Barnes, G. B., & Einhorn, T. A. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415853-5.00001-7 · Cited by 58
Jeyapalina, S., Beck, P. J., Bloebaum, R. D., & Bachus, K. N. (2013) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-013-3381-0 · Cited by 53
Frank, M., Reisinger, A., Andriotis, O. G., Pahr, D. H., & Thurner, P. J. (2024) · JBMR Plus · doi:10.1093/jbmrpl/ziae049 · Cited by 53
Electrochemical characteristics of calcium-phosphatized AZ31 magnesium alloy in 0.9 % NaCl solution
Hadzima, B., Mhaede, M., & Pastorek, F. (2014) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-014-5161-0 · Cited by 52
“6–27 GPa, respectively [8–11].”
Spies, B. C., Sauter, C., Wolkewitz, M., & Kohal, R. (2015) · Dental Materials · doi:10.1016/j.dental.2014.12.013 · Cited by 52
“The resin had a modulus of elasticity of approximately 12 GPa which approximates that of human bone (10–18 GPa) [51].”
Background
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.