Young's modulus of trabecular and cortical bone material: Ultrasonic and microtensile measurements
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
An ultrasonic technique and microtensile testing were used to determine the Young's modulus of individual trabeculae and micro-specimens of cortical bone cut to similar size as individual trabeculae. The average trabecular Young's modulus measured ultrasonically and mechanically was 14.8 GPa (S.D. 1.4) and 10.4 (S.D. 3.5) and the average Young's modulus of microspecimens of cortical bone measured ultrasonically and mechanically was 20.7 GPa (S.D. 1.9) and 18.6 GPa (S.D. 3.5). With either testing technique the mean trabecular Young's modulus was found to be significantly less than that of cortical bone (p < 0.0001). However, the specimens were dried before microtensile testing so Young's modulus values may have been greater than those of trabeculae in vivo. Using Young's modulus measurements obtained from 450 cubes of cancellous bone and 256 cubes of cortical bone, Wolff's hypothesis that cortical bone is simply dense cancellous bone was tested. A multiple regression analysis that controlled for group membership showed that Young's modulus of cortical bone cannot be extrapolated from the Young's modulus vs density relationship for cancellous bone, yet the Young's modulus of trabeculae can be predicted by extrapolation from the relationship between Young's modulus vs density of the cancellous bone. These results suggest that when considered mechanically, cortical and trabecular bone are not the same material.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Tensile tests (136), ultrasonic measurements (137), nanoindentation (138), and scanning acoustic microscopy (139) techniques indicate that the elastic modulus of trabecular tissue is around 10–20 GPa.”
From Bone Mechanical Properties in Healthy and Diseased States (2018) · cites this paper as [137]
Citations
Cites
(2005) · Technometrics · doi:10.1198/tech.2005.s303 · Cited by 17,923
The compressive behavior of bone as a two-phase porous structure
Carter, D., & Hayes, W. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759070-00021 · Cited by 2,001 · cited 2×
“Carter and Hayes (1977) suggested”
BackgroundMarks' standard handbook for mechanical engineers
(2000) · Choice Reviews Online · doi:10.5860/choice.37-6297 · Cited by 919
On the dependence of the elasticity and strength of cancellous bone on apparent density
Rice, J. C., Cowin, S. C., & Bowman, J. A. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90008-5 · Cited by 734
A continuous wave technique for the measurement of the elastic properties of cortical bone
Ashman, R. B., Cowin, S. C., Van Buskirk, W. C., & Rice, J. C. (1984) · Journal of Biomechanics · doi:10.1016/0021-9290(84)90029-0 · Cited by 733
Self-citationBone Compressive Strength: The Influence of Density and Strain Rate
Carter, D. R., & Hayes, W. C. (1976) · Science · doi:10.1126/science.996549 · Cited by 709
Choi, K., Kuhn, J. L., Ciarelli, M. J., & Goldstein, S. A. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90003-l · Cited by 532
Reilly, D. T., Burstein, A. H., & Frankel, V. H. (1974) · Journal of Biomechanics · doi:10.1016/0021-9290(74)90018-9 · Cited by 504
Properties and an Anisotropic Model of Cancellous Bone From the Proximal Tibial Epiphysis
Williams, J. L., & Lewis, J. L. (1982) · Journal of Biomechanical Engineering · doi:10.1115/1.3138303 · Cited by 415
Elastic modulus of trabecular bone material
Ashman, R. B., & Rho, J. Y. (1988) · Journal of Biomechanics · doi:10.1016/0021-9290(88)90167-4 · Cited by 392
Self-citation
Research works printed but not linked: 5
- Choi, 1989, The elastic modulus of trabecular, subchondral, and cortical bone tissue, Trans 35th orthop. Res. Soc., 14, 102
- Choi, 1991, The fatigue properties of bone tissues on a microstructural level, Trans. 37th orthop. Res. Soc., 16, 485
- Ku, 1987, The mechanical properties of single trabeculae, Trans. 33th orthop. Res. Soc., 12, 48
- Mente, 1987, Young's modulus of trabecular bone tissue, Trans. 33th Orthop. Res. Soc., 12, 49
- Runkle, 1975, The micro-mechanics of cancellous bone, Bull. Hosp. J. Dis, 36, 2
Cited by
Items 301–400 of 1,000
Trad, Z., Barkaoui, A., Chafra, M., & Tavares, J. M. R. S. (2018) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411918770706 · Cited by 53
Superelasticity and compression behavior of porous TiNi alloys produced using Mg spacers
AYDOĞMUŞ, T., & Bor, Ş. (2012) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2012.05.018 · Cited by 51
“Al2O3), calcium hydroxyapatite (Ca10(PO4)6(OH)2) or tricalcium phosphate (Ca3(PO4)2) in biomedical industry have higher elastic modulus values ranging from 110 GPa to 210 GPa compared to elastic modulus of the bone which is smaller than 20 GPa (Suchanek and Yoshimura, 1998).”
BackgroundCorrosion of magnesium and magnesium–calcium alloy in biologically-simulated environment
Harrison, R. P., Maradze, D., Lyons, S., Zheng, Y., & Liu, Y. (2014) · Progress in Natural Science Materials International · doi:10.1016/j.pnsc.2014.08.010 · Cited by 51
Thorpe, A. A., Creasey, S., Sammon, C., & Maitre, C. L. L. (2016) · European Cells and Materials · doi:10.22203/ecm.v032a01 · Cited by 51
“The mechanical properties of HAPna loaded hydrogels displayed here still fall short of those of native bone, which have been reported to display elastic moduli of 14-20 GPa (cortical bone) (Reilly et al. , 1974; Rho et al. , 1993; Rho et al. , 1997).”
Wear, K. A., & Laib, A. (2003) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2003.1226542 · Cited by 51
Raoofi, S., Khademi, M., Amid, R., Kadkhodazadeh, M., & Movahhedi, M. R. (2013) · PubMed Central · doi:10.5681/joddd.2013.021 · Cited by 50
Yang, P., Zhang, Y., Liu, J., Xiao, J., Ma, L., & Zhu, C. R. (2015) · Acta Orthopaedica et Traumatologica Turcica · doi:10.3944/aott.2015.14.0204 · Cited by 50
“[26] The locking plate system was made from titanium alloy (E=110GPa, v=0.”
MethodThe Clinical History and Basic Science Origins of Transcutaneous Osseointegration for Amputees
Hoellwarth, J. S., Tetsworth, K. D., Akhtar, M. A., & Muderis, M. A. (2022) · Advances in Orthopedics · doi:10.1155/2022/7960559 · Cited by 50
“Human cortical bone has a Young’s elastic modulus between 3 and 20 GPa [49, 50], varying significantly with health, age, and direction of force (bone is anisotropic, whereas metal is effectively isotropic).”
BackgroundA finite-element analysis study of the metatarsophalangeal joint of the hallux rigidus
Flavin, R., Halpin, T., O’Sullivan, R., FitzPatrick, D. P., Ivankoviç, A., & Stephens, M. M. (2008) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.90b10.20506 · Cited by 50
Parr, W. C., Chamoli, U., Jones, A. S., Walsh, W. R., & Wroe, S. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.11.011 · Cited by 49
“1) Micro CT full 3D reconstruction including trabecular network, trabecular properties from Rho et al. (1993) 2610 2549684 20700 (cor), 14800 (can) 0.”
BackgroundInfluentialBiomimetics of Bone Implants: The Regenerative Road
Brett, E. A., Flacco, J., Blackshear, C. P., Longaker, M. T., & Wan, D. C. (2017) · BioResearch open access · doi:10.1089/biores.2016.0044 · Cited by 49
“The Young’s modulus of trabecular bone is 10.4–14.8 GPa, and cortical bone measures 18.4–20.7 GPa.18 These values differ drastically from those of commonly used metals for bone implants; stainless steel measuring 180 GPa, cobalt chromium (Co-Cr) at 210 GPa, and titanium at 110 GPa.19 Stress shielding is the physiologi…”
BackgroundInfluentialSochacka, P., Miklaszewski, A., & Jurczyk, M. (2018) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2018.10.217 · Cited by 49
Gruber, E. J., & Leifer, C. A. (2020) · Innate Immunity · doi:10.1177/1753425919838322 · Cited by 45
“Healthy tissues vary in stiffness from very soft adipose tissue and brain (a few hundred pascals) to stiff or rigid tissues, with bone representing the highest stiffness (>1GPa).(3,4) Even within one tissue, regional stiffness can vary dramatically.”
BackgroundAbar, B. M., Calleja, A. A., Kelly, A. D. R., Kelly, C. N., Gall, K., & West, J. L. (2020) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.37006 · Cited by 49
Histotripsy Ablation of Bone Tumors: Feasibility Study in Excised Canine Osteosarcoma Tumors
Ruger, L. N., Hendricks-Wenger, A., Coutermarsh‐Ott, S. L., Gannon, J., Hay, A. N., Dervisis, N. G., Klahn, S. L., Allen, I. C., Tuohy, J. L., & Vlaisavljevich, E. (2021) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2021.08.004 · Cited by 49
Kosmopoulos, V., & Nana, A. (2013) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-013-3379-7 · Cited by 49
“222) [2, 3] with density set to 1817 kg/m 3 [22].”
Jørgensen, C., & Kundu, T. (2002) · Journal of Orthopaedic Research® · doi:10.1016/s0736-0266(01)00061-4 · Cited by 51
3-dimensional printing for anterior cervical surgery: a review
Choy, W. J., Parr, W. C., Phan, K. H., Walsh, W. R., & Mobbs, R. J. (2018) · Journal of Spine Surgery · doi:10.21037/jss.2018.12.01 · Cited by 48
“02–2 GPa) serves as a high potential for subsidence (59-61).”
BackgroundDargusch, M. S., Venezuela, J., Dehghan‐Manshadi, A., Johnston, S., Yang, N., Mardon, K., Lau, C., & Allavena, R. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.202000667 · Cited by 48
Yin, J., Li, M., Dai, G., Zhou, H., Ma, L., & Zheng, Y. (2021) · Journal of Bionic Engineering · doi:10.1007/s42235-021-0031-1 · Cited by 48
Surface characterization of TiO2 nanotube arrays produced on Ti6Al4V alloy by anodic oxidation
Durdu, S., Sancak, M., Yalçın, E., Usta, M., Akagündüz, E., & Altinkök, A. (2021) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2021.127903 · Cited by 48
Guo, T., Ivanovski, S., & Gulati, K. (2022) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2021.11.050 · Cited by 47
Bioinspired Flexible and Tough Layered Peptide Crystals
Adler‐Abramovich, L., Arnon, Z. A., Sui, X., Azuri, I., Cohen, H., Hod, O., Kronik, L., Shimon, L. J. W., Wagner, H. D., & Gazit, E. (2017) · Advanced Materials · doi:10.1002/adma.201704551 · Cited by 48
Sputtered Si and Mg doped hydroxyapatite for biomedical applications
Vlădescu, A., Cotruț, C. M., Azem, F. A., Bramowicz, M., Pană, I., Braic, V., Birlik, İ., Kiss, A. E., Braic, M. T., Abdulgader, R., et al. (2018) · Biomedical Materials · doi:10.1088/1748-605x/aa9718 · Cited by 47
Didier, C. M., Kundu, A., & Rajaraman, S. (2020) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0129-3 · Cited by 47
Engineering bio-inks for 3D bioprinting cell mechanical microenvironment
Yang, Y., Jia, Y., Yang, Q., & Xu, F. (2022) · International Journal of Bioprinting · doi:10.18063/ijb.v9i1.632 · Cited by 47
“Bone E 1.28–1.97 GPa Nanoscale AFM [36] Bone E 10.4–20.7 GPa Macroscale USE, Micro-tensile [29] Cardiac muscle E 8 kPa Macroscale MRE, Tension [84] Cardiac muscle G 5–50 kPa Macroscale USE, MRE [85] Lung G 0.84–1.5 kPa Macroscale MRE [86,87] Lung E 1.96 kPa Nanoscale AFM [88] Liver E 1.5–6.5 kPa Macroscale USE, Cyclic…”
BackgroundInfluentialEvolution of load transfer between hydroxyapatite and collagen during creep deformation of bone
Deymier-Black, A. C., Yuan, F., Singhal, A., Almer, J., Brinson, L. C., & Dunand, D. C. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2011.08.014 · Cited by 48
DISINTEGRATION OF BONE CEMENT BY CONTINUOUS AND PULSATING WATER JET
Hloch, S., Foldyna, J., Sitek, L., Zeleňák, M., Hlavcek, P., Hvizdoš, P., Kľoc, J., Monka, P. P., Monková, K., Kozak, D., et al. (2013) · ASEP · Cited by 47
Bianchi, M., Esposti, L. D., Ballardini, A., Liscio, F., Berni, M., Gambardella, A., Leeuwenburgh, S. C. G., Sprio, S., Tampieri, A., & Iafisco, M. (2017) · Surface and Coatings Technology · doi:10.1016/j.surfcoat.2017.04.012 · Cited by 46
Alcala‐Orozco, C. R., Cui, X., Hooper, G. J., Lim, K. S., & Woodfield, T. B. F. (2021) · Acta Biomaterialia · doi:10.1016/j.actbio.2021.03.008 · Cited by 46
Ma, S., Tang, Q., Zhu, C., Wang, F., Feng, Q., Song, J. H., Setchi, R., Ma, C., & Tao, R. (2022) · Chinese Journal of Mechanical Engineering Additive Manufacturing Frontiers · doi:10.1016/j.cjmeam.2022.100051 · Cited by 46
On the Road to Personalized Medicine: Multiscale Computational Modeling of Bone Tissue
Podshivalov, L., Fischer, A., & Bar‐Yoseph, P. (2014) · Archives of Computational Methods in Engineering · doi:10.1007/s11831-014-9120-1 · Cited by 46
Ultrasonic Wave Velocity Measurement in Small Polymeric and Cortical Bone Specimens
Kohles, S. S., Bowers, J. R., VAILAS, A. C., & Vanderby, R. (1997) · Journal of Biomechanical Engineering · doi:10.1115/1.2796085 · Cited by 46
Modeling of bone at a single lamella level
Jasiuk, I., & Ostoja‐Starzewski, M. (2004) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-004-0048-5 · Cited by 48
Juhasz, J. A., Best, S. M., Bonfield, W., Kawashita, M., Miyata, N., Kokubo, T., & Nakamura, T. (2003) · Journal of Materials Science Materials in Medicine · doi:10.1023/a:1023499728588 · Cited by 45
Liu, X. S., Wang, J., Zhou, B., Stein, E. M., Shi, X., Adams, M., Shane, E. J., & Guo, X.-D. E. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1919 · Cited by 44
A CaCO 3 /nanocellulose-based bioinspired nacre-like material
Farhadi‐Khouzani, M., Schütz, C., Durak, G. M., Fornell, J., Sort, J., Salazar‐Alvarez, G., Bergström, L., & Gebauer, D. (2017) · Journal of Materials Chemistry A · doi:10.1039/c6ta09524k · Cited by 44
Wong, S. A., Rivera, K. O., Miclau, T., Alsberg, E., Marcucio, R. S., & Bahney, C. S. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00058 · Cited by 40
“The loss of collagen II and aggrecan leads to a temporary reduction in tensile strength and stiffness of the tissue, which changes the mechanical microenvironment of chondrocytes and exposes the cells to greater strains that may induce phenotypic changes (Figure 3) (Stockwell, 1981; Ashman and Jae Young Rho, 1988; Rho…”
BackgroundInfluentialReeves, J. M., Langohr, G. D. G., Athwal, G. S., & Johnson, J. A. (2018) · Journal of Shoulder and Elbow Surgery · doi:10.1016/j.jse.2018.06.002 · Cited by 44
Asgari, M., Abi‐Rafeh, J., Hendy, G. N., & Pasini, D. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.01.024 · Cited by 44
Biophysical Approaches for Applying and Measuring Biological Forces
Sun, W., Gao, X., Lei, H., Wang, W., & Cao, Y. (2021) · Advanced Science · doi:10.1002/advs.202105254 · Cited by 44
The Bone Organ System: Form and Function
Morgan, E. F., Barnes, G. B., & Einhorn, T. A. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-375098-3.50004-4 · Cited by 44
Gel-derived bioglass as a compound of hydroxyapatite composites
Cholewa‐Kowalska, K., Pawlik, J., Łączka, M., Niedźwiedzki, Ł., Madej, W., & Osyczka, A. M. (2009) · Biomedical Materials · doi:10.1088/1748-6041/4/5/055007 · Cited by 44
Novel method to analyze post-yield mechanical properties at trabecular bone tissue level
Carretta, R., Luisier, B., Bernoulli, D., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.12.003 · Cited by 43
Kang, N., Wu, Y., Gong, P., Yue, L., & Ou, G. (2014) · Oral Surgery Oral Medicine Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2014.05.021 · Cited by 43
Influence of fluoride for enhancing bioactivity onto phosphate based glasses
Rajkumar, G., Dhivya, V., Mahalaxmi, S., Rajkumar, K., Sathishkumar, G. K., & Karpagam, R. (2018) · Journal of Non-Crystalline Solids · doi:10.1016/j.jnoncrysol.2018.04.046 · Cited by 43
Duan, Y., & Griggs, J. A. (2018) · Dental Materials · doi:10.1016/j.dental.2018.09.001 · Cited by 43
Cox, L. G. E., van Rietbergen, B., van Donkelaar, C. C., & Ito, K. (2011) · Osteoarthritis and Cartilage · doi:10.1016/j.joca.2011.02.007 · Cited by 43
Ascoli, V., Lo‐Coco, F., Torelli, G., Vallisa, D., Cavanna, L., Bergonzi, C., & Luppi, M. (2002) · PubMed · Cited by 43
García, E., Miranzo, P., & Sainz, M. A. (2018) · Ceramics International · doi:10.1016/j.ceramint.2018.04.100 · Cited by 42
García-Cabezón, C., Godinho, V., Salvo‐Comino, C., Torres, Y., & Martín, F. (2021) · Materials · doi:10.3390/ma14216322 · Cited by 42
“The stress-shielding that is generated can cause the resorption and fracture of the adjacent bone [2].”
BackgroundHighly Enhanced Damping Figure of Merit in Biomimetic Hierarchical Staggered Composites
Zhang, P., & To, A. C. (2014) · Journal of Applied Mechanics · doi:10.1115/1.4026239 · Cited by 42
Chen, W., Xie, Y. M., Imbalzano, G., Shen, J., Xu, S., Lee, S., & Lee, P. V. S. (2016) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-016-0097-6 · Cited by 42
McNamara, L. M. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-055294-1.00068-4 · Cited by 42
Harnessing the Potential of PLGA Nanoparticles for Enhanced Bone Regeneration
Hassan, M. O., Abdelnabi, H., & Mohsin, S. (2024) · Pharmaceutics · doi:10.3390/pharmaceutics16020273 · Cited by 41
“Additionally, research using ultrasonic and mechanical techniques suggests Young’s modulus of 10.4–14.8 GPa for cancellous bone and 18.6–20.7 GPa for cortical bone [64].”
MethodInfluentialGuo, C., Ding, T., Cheng, Y., Zheng, J., Fang, X., & Feng, Z. (2025) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1548675 · Cited by 42
“…spongy, consisting of interwoven trabeculae arranged in a 50% – 90% porosity, which grow in the direction of extended stress to bear greater weight (Rho et al., 1993), while cortical bone is dense and distributed on the peripheral surface of the bone and consists of tightly arranged bone plates…”
Torres-Sánchez, C., McLaughlin, J., & Fotticchia, A. (2017) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2017.10.026 · Cited by 42
“Caution is advised when cross-comparing from studies undertaken using different measuring techniques as these influence the order of magnitude of the results [25, 26].”
ResultPlasma ion implantation enabled bio-functionalization of PEEK improves osteoblastic activity
Wakelin, E., Yeo, G. C., Mckenzie, D., Bilek, M., & Weiss, A. (2018) · APL Bioengineering · doi:10.1063/1.5010346 · Cited by 37
Zhang, J., van den Boom, S. J., van Keulen, F., & Aragón, A. M. (2019) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.05.018 · Cited by 41
“3 (cortical bone) [49,50].”
Application of Finite Element Analysis in Dentistry
Hsu, M.-L., & Chang, C.-L. (2010) · Sciyo eBooks · doi:10.5772/10007 · Cited by 41
Shen, W.-L., Chen, C.-S., & Hsu, M. (2010) · PubMed · Cited by 43
Li, Y., Liu, C., Zhai, H., Zhu, G., Pan, H., Xu, X., & Tang, R. (2014) · RSC Advances · doi:10.1039/c4ra02821j · Cited by 41
Mechanical behavior and microstructure of compressed Ti foams synthesized via freeze casting
Jenei, P., Choi, H., Tóth, A., Choe, H., & Gubicza, J. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.07.012 · Cited by 40
“The Young's moduli of both foams were 23 GPa, which was in good agreement with the value expected from their porosity.”
BackgroundInfluentialBiomimetic design of implants for long bone critical-sized defects
Rezapourian, M., Kamboj, N., Jasiuk, I., & Hussainova, I. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105370 · Cited by 40
Wong, P., Kurniawan, D., Wu, J., Wang, W.-R., Chen, K., Chen, C., Chen, Y., Veeramuthu, L., Kuo, C., Ostrikov, K., et al. (2023) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.3c05297 · Cited by 40
Biomechanics of Bone and Age-Related Fractures
Morgan, E. F., & Bouxsein, M. (2008) · Elsevier eBooks · doi:10.1016/b978-0-12-373884-4.00024-0 · Cited by 40
Elastic wave propagation in bone in vivo: Methodology
Cheng, S., TIMONEN, J., & Suominen, H. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(94)00079-j · Cited by 40
van Kampen, K. A., Olăreț, E., Stancu, I., Moroni, L., & Mota, C. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.111472 · Cited by 39
Laser powder bed fusion of Ti6Al4V lattice structures and their applications
Dzogbewu, T. C. (2020) · Journal of Metals Materials and Minerals · doi:10.55713/jmmm.v30i4.821 · Cited by 39
“A thorough review of the literature reveals a disparity results for elastic modulus for compact bone material, it ranges from 1-20 GPa [41-47].”
BackgroundInfluentialChamoli, U., & Wroe, S. (2011) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2011.05.020 · Cited by 39
In vivo bone strain and finite element modeling of a rhesus macaque mandible during mastication
Panagiotopoulou, O., Iriarte-Díaz, J., Wilshin, S. D., Dechow, P. C., Taylor, A. B., Abraha, H. M., Aljunid, S. F., & Ross, C. F. (2017) · Zoology · doi:10.1016/j.zool.2017.08.010 · Cited by 39
“However, constraints on image resolution mean that defining the geometry of the individual trabeculae in the subcortex can be problematic, as CT/μCT cannot accurately capture the fine details of the trabeculae within the subcortex (Rho et al., 1993; Dechow and Hylander, 2000; Rapoff et al., 2008).”
BackgroundEffect of porosity on mechanical and electrochemical properties of Ti–6Al–4V alloy
Martínez, C., Guerra, C., da Silva, D. M., Cubillos, M., Briones, F., Muñoz, L. A., Paez, M. A., Aguilar, C. E., & Sancy, M. (2020) · Electrochimica Acta · doi:10.1016/j.electacta.2020.135858 · Cited by 39
Mechanical Significance of the Trabecular Microstructure of the Human Mandibular Condyle
van Ruijven, L. J., Giesen, E. B. W., & van Eijden, T. M. G. J. (2002) · Journal of Dental Research · doi:10.1177/154405910208101010 · Cited by 39
“Since the bone volume fraction was known, we assumed that the volume fraction was equal to the bone density and used the Young's moduli found by Rho et al. (1993) for cortical and trabecular bone.”
BackgroundMethodInfluentialGong, H., Zhang, M., Qin, L., & Hou, Y. (2007) · Annals of Biomedical Engineering · doi:10.1007/s10439-007-9332-8 · Cited by 39
Malandrino, A., Fritsch, A., Lahayne, O., Kropik, K., Redl, H. R., Noailly, J., Lacroix, D., & Hellmich, C. (2012) · Materials Letters · doi:10.1016/j.matlet.2012.03.052 · Cited by 38
“25 MHz relate to wave lengths which are too large to capture any more extracellular material in trabecular bone — hence, corresponding values reported by [48,49] are lower than the values reported in this paper.”
ResultThe bone organ system: form and function
Morgan, E. F., & Gerstenfeld, L. C. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-813073-5.00002-2 · Cited by 38
Hydrogel: A Potential Material for Bone Tissue Engineering Repairing the Segmental Mandibular Defect
Maruf, D. S. A. A., Ghosh, Y. A., Xin, H., Cheng, K., Mukherjee, P., Crook, J. M., Wallace, G. G., Klein, T. J., & Clark, J. R. (2022) · Polymers · doi:10.3390/polym14194186 · Cited by 38
“Hydrogels and modified variants have low mechanical strength compared to cortical bone [195].”
BackgroundGilbert, M. M., Snively, E. D., & Cotton, J. R. (2016) · PLoS ONE · doi:10.1371/journal.pone.0149708 · Cited by 38
“Assigned material properties (Table 1) are those of compact and “bulk” cancellous bone (not of individual trabeculae, which have a stiffness closer to that of compact bone: [53,54]).”
BackgroundChatzipanagis, K., Baumann, C. G., Sandri, M., Sprio, S., Tampieri, A., & Kröger, R. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.09.028 · Cited by 38
Hierarchical Design of Tissue‐Mimetic Fibrillar Hydrogel Scaffolds
Pardo, A., Gómez‐Florit, M., Davidson, M. D., Öztürk-Öncel, M. Ö., Domingues, R. M. A., Burdick, J. A., & Gomes, M. E. (2024) · Advanced Healthcare Materials · doi:10.1002/adhm.202303167 · Cited by 37
Mao, Q., Su, K., Zhou, Y., Hossaini-Zadeh, M., Lewis, G. S., & Du, J. H. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.03.008 · Cited by 38
Martin, R. B., Burr, D. B., Sharkey, N. A., & Fyhrie, D. P. (2015) · Springer eBooks · doi:10.1007/978-1-4939-3002-9_7 · Cited by 37
Pure chitosan microfibres for biomedical applications
Toskas, G., Brünler, R., Hund, H., Hund, R., Hild, M., Aibibu, D., & Cherif, C. (2013) · Autex Research Journal · doi:10.2478/v10304-012-0041-5 · Cited by 37
Cox, L. G. E., van Rietbergen, B., van Donkelaar, C. C., & Ito, K. (2010) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-010-0267-x · Cited by 37
“…marrow 1 MPa νm Poisson ratio marrow 0.3 – γ Bone material constant 3.0 – j a Eriksen and Kassem (1992) b Parfitt (1994) c Marotti et al. (1990) d Mullender and Huiskes (1995) e Rho et al. (1993) f Choi et al. (1990) g van Rietbergen et al. (1995) h Rho (1996) i Ashman et al. (1984) j Currey…”
BackgroundMethodInfluentialPegg, E. C., & Gill, H. S. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.07.037 · Cited by 37
Effect of high-energy X-ray doses on bone elastic properties and residual strains
Singhal, A., Deymier-Black, A. C., Almer, J., & Dunand, D. C. (2011) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2011.05.035 · Cited by 36
“…of 21.9 GPa on bovine femur (age, sex unknown) (Buskirk et al., 1981), and 20.7 GPa for human tibial bone (age, sex, cause of death unknown) (Rho et al., 1993) and reasonably close to values of 27.6 ± 1.7 GPa and 29.7 ± 3.5 GPa for fresh, unembalmed human and canine femora, respectively…”
BackgroundInfluentialEngineered Phage Matrix Stiffness-Modulating Osteogenic Differentiation
Lee, H.-S., Kang, J., Chung, W.-J., Lee, D. H., Lee, B. Y., Lee, S., & Yoo, S. Y. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b17871 · Cited by 36
Bone mechanobiology in health and disease
Verbruggen, S. W., & McNamara, L. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-812952-4.00006-4 · Cited by 36
Tai, B. L., Kao, Y.-T., Payne, N., Zheng, Y., Chen, L., & Shih, A. J. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.08.004 · Cited by 36
Clifton, W. E., Nottmeier, E. W., Damon, A. C., Dove, C., Chen, S. G., & Pichelmann, M. A. (2019) · Cureus · doi:10.7759/cureus.4440 · Cited by 36
Boughton, O. R., Ma, S., Cai, X., Yan, L., Peralta, L. M., Laugier, P., Marrow, T. J., Giuliani, F., Hansen, U. N., Abel, R. L., et al. (2019) · Scientific Reports · doi:10.1038/s41598-019-43686-6 · Cited by 36
Amid, R., Raoofi, S., Kadkhodazadeh, M., Movahhedi, M. R., & Khademi, M. (2013) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt-2012-0108 · Cited by 36
“Material properties play an important role in accuracy of the finite element method [7, 8, 30, 41, 42].”
BackgroundMethodMaterial Stiffness Effects on Neurite Alignment to Photopolymerized Micropatterns
Tuft, B. W., Zhang, L., Xu, L., Hangartner, A., Leigh, B., Hansen, M. R., & Guymon, C. A. (2014) · Biomacromolecules · doi:10.1021/bm501019s · Cited by 36
Singh, D., Rana, A., Jhajhria, S. K., Garg, B., Pandey, P. M., & Kalyanasundaram, D. (2018) · Journal of Applied Biomaterials & Functional Materials · doi:10.1177/2280800018793816 · Cited by 35
Jin, Z.-H., Peng, M., & Li, Q. (2019) · Journal of Dental Sciences · doi:10.1016/j.jds.2019.12.003 · Cited by 35
“All materials used in FEA were assumed as homogenous, linearly elastic, and isotropic (Table 1).(15,16) The bone and implant was considered as complete osseointegration, and the interface of bone-implant was defined as the bonded contact.”
MethodKim, S. H. L., Lee, S. S., Kim, I., Kwon, J., Kwon, S. C., Bae, T., Hur, J. K., Lee, H.-J., & Hwang, N. S.-Y. (2020) · Journal of Tissue Engineering · doi:10.1177/2041731420909208 · Cited by 35
Functional morphology of the jaw adductor muscles in the Canidae
Penrose, F., Cox, P. G., Kemp, G. J., & Jeffery, N. S. (2020) · The Anatomical Record · doi:10.1002/ar.24391 · Cited by 37
Mid-term results of a new femoral prosthesis using Ti-Nb-Sn alloy with low Young’s modulus
Chiba, D., Yamada, N., Mori, Y., Oyama, M., Ohtsu, S., Kuwahara, Y., Baba, K., Tanaka, H., Aizawa, T., Hanada, S., et al. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04879-1 · Cited by 35
“6% Nb-4% Sn (TNS) alloy with the Young’s modulus as low as 40 GPa.”
BackgroundInfluentialDynamic bioengineered hydrogels as scaffolds for advanced stem cell and organoid culture
Bahlmann, L. C., Fokina, A., & Shoichet, M. S. (2017) · MRS Communications · doi:10.1557/mrc.2017.72 · Cited by 36
Hip resurfacing increases bone strains associated with short‐term femoral neck fracture
Long, J. P., Santner, T. J., & Bartel, D. L. (2009) · Journal of Orthopaedic Research® · doi:10.1002/jor.20884 · Cited by 35
Metadata
- Authors
- Rho, J. Y., Ashman, R. B., & Turner, C. H.
- Affiliations
- University at Buffalo, State University of New York (US)
- Indiana University Indianapolis (US)
- Corresponding author
- Rho, Jae Young
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 1993-02
- Volume
- 26
- Issue
- 2
- Pages
- 111-119
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2155790754
- Cited by
- 1,283
- References
- 25
- Citations by year
- 2026: 60 · 2025: 71 · 2024: 64 · 2023: 70 · 2022: 70 · 2021: 82 · 2020: 76 · 2019: 60 · 2018: 79 · 2017: 72 · 2016: 58 · 2015: 47 · 2014: 54 · 2013: 44 · 2012: 46
- FWCI
- 7.51
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health (5r23am036257-02)
- Topics
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone health and osteoporosis research
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Bone fractures and treatments
- Keywords
- Young's modulus, trabecular bone, cortical bone, ultrasonic measurement, microtensile testing, bone mechanical properties, bone mineral density, Wolff's law, bone material properties
- MeSH terms
- Aged, Aluminum, Bone and Bones, Elasticity, Femur, Humans, Humerus, Middle Aged, Regression Analysis, Stainless Steel, Tensile Strength, Tibia, Ultrasonography, Bone Density
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.