The cone electrode: a long-term electrode that records from neurites grown onto its recording surface
The DOI matches its Crossref record; 33 of the 34 references it cites were found in a registry or an index.
Abstract
A novel long-term recording electrode combines neural regeneration with a standard wire recording technique. The electrode consists of an insulated gold wire fixed inside a hollow glass cone. A piece of sciatic nerve is placed in the glass cone before implantation in cortex of rat. Cortical neurites grow into the sciatic nerve in the cone from surrounding neurons and their electrical activity is recorded via the wire (or wires) in the cone. This activity increases in amplitude over the first few weeks after implantation and remains stable until termination of the experiment many months later. Activity of both single and multi units has been recorded. The cone electrode opens unique opportunities for studies of neurite growth in vivo, for plasticity studies on a captive set of neurites, for studying the neural correlates of behavior and motor learning, and for accessing the central nervous systems of patients with severe paralysing and communicative disorders.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Here, a piece of a rat sciatic nerve was placed into a cone of 1.5 mm length and 100-200 m mdiameter. After implantation in the brain of a rat, neurite ingrowth was observed and stable recordings were obtained over 6 months.”
From A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems (2005) · cites this paper as Kennedy, 1989
In the citing paper
“The neurotrophic cone electrode developed by Kennedy was a pioneering example of a biohybrid central neural prosthesis: a section of nerve housed within a glass electrode assembly was used to encourage neurite ingrowth near the gold recording wire.82”
From Regenerative Electrode Interfaces for Neural Prostheses. (2016) · cites this paper as [82]
Citations
Cites
Plum, F. (1960) · Archives of Neurology · doi:10.1001/archneur.1960.03840090124020 · Cited by 10,364
Llinás, R. R. (1988) · Science · doi:10.1126/science.3059497 · Cited by 2,285
David, S., & Aguayo, A. J. (1981) · Science · doi:10.1126/science.6171034 · Cited by 1,683
Somatosensory cortical map changes following digit amputation in adult monkeys
Merzenich, M. M., Nelson, R. J., Stryker, M. P., Cynader, M. S., Schoppmann, A., & Zook, J. M. (1984) · Journal of Comparative Neurology · doi:10.1002/cne.902240408 · Cited by 1,328
Motor control mechanisms in health and disease
Desmedt, J. E. (1983) · Dépôt institutionnel de l'Université libre de Bruxelles (Université Libre de Bruxelles) · Cited by 1,209
Fluoro-gold: a new fluorescent retrograde axonal tracer with numerous unique properties
Schmued, L. C., & Fallon, J. H. (1986) · Brain Research · doi:10.1016/0006-8993(86)91199-6 · Cited by 886
The organization of the rat motor cortex: A microstimulation mapping study
NEAFSEY, E., BOLD, E., HAAS, G., HURLEYGIUS, K., QUIRK, G., SIEVERT, C., & TERREBERRY, R. (1986) · Brain Research · doi:10.1016/s0006-8993(86)80191-3 · Cited by 705
The organization of the rat motor cortex: A microstimulation mapping study
Neafsey, E. J., Bold, E. L., Haas, G., Hurley-Gius, K. M., Quirk, G., Sievert, C. F., & Terreberry, R. R. (1986) · Brain Research Reviews · doi:10.1016/0165-0173(86)90011-1 · Cited by 626
Receptive fields of barrels in the somatosensory neocortex of the rat
Welker, C. (1976) · Journal of Comparative Neurology · doi:10.1002/cne.901660205 · Cited by 519
Extensive elongation of axons from rat brain into peripheral nerve grafts
Benfey, M., & Aguayo, A. J. (1982) · Nature · doi:10.1038/296150a0 · Cited by 442
Research works printed but not linked: 2
- Asanuma, 1981, Vol. 2, 703
- DiStefano, 1986, Induction of nerve growth factor (NGF) receptors on cultured rat Schwann cells, Soc. Neurosci. Abstr., 12, 392
Cited by
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
“In 1989, Kennedy described an intracortical electrode consisting of a hollow glass cone containing recording wires (Kennedy, 1989).”
BackgroundNeural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Electrical stimulation of excitable tissue: design of efficacious and safe protocols
Merrill, D. R., Bikson, M., & Jefferys, J. G. R. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.10.020 · Cited by 2,078
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
“A simple coating of Teflon or S-isonel, a high temperature polyester enamel similar to Teflon, has been used with great success to coat wire electrodes (Kennedy, 1989; Nicolelis et al., 2003).”
BackgroundMethodBrain–machine interfaces: past, present and future
Lebedev, M. A., & Nicolelis, M. A. L. (2006) · Trends in Neurosciences · doi:10.1016/j.tins.2006.07.004 · Cited by 1,875
“82 Kennedy, P.R. (1989) The cone electrode: a long-term electrode that records from neurites grown onto its recording surface. J. Neurosci. Methods 29, 181–193 83 Kennedy, P.R. and Bakay, R.A. (1998) Restoration of neural output from a paralyzed patient by a direct brain connection.NeuroReport 9, 1707–1711 84 Kennedy,…”
BackgroundInfluentialNavarro, X., Krueger, T. B., Lago, N., Micera, S., Stieglitz, T., & Dario, P. (2005) · Journal of the Peripheral Nervous System · doi:10.1111/j.1085-9489.2005.10303.x · Cited by 845
“Another bioelectronic interface was introduced as ‘cone electrode’ (Kennedy, 1989).”
MethodCanales, A., Jia, X., Froriep, U. P., Koppes, R. A., Tringides, C. M., Selvidge, J., Lu, C., Hou, C., Wei, L., Fink, Y., et al. (2015) · Nature Biotechnology · doi:10.1038/nbt.3093 · Cited by 668
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
“Kennedy and his colleagues reported that the cone electrode remained functional during the entire implantation period, which was 15 mo in the monkey (420, 422), 16 mo in the rat (418), and longer than 4 yr in humans (47).”
BackgroundMethodInfluentialFlexible polyimide-based intracortical electrode arrays with bioactive capability
Rousche, P. J., Pellinen, D. S., Pivin, D. P., Williams, J. C., Vetter, R. J., & Kipke, D. R. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.914800 · Cited by 644
“have succeeded in creating a neural interface which actively promotes neurite growth toward the recording site [18].”
BackgroundDirect control of a computer from the human central nervous system
Kennedy, P. R., Bakay, R. A. E., Moore, M. M., Adams, K., & Goldwaithe, J. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847815 · Cited by 573
“Our approach is to use trophic factors to encourage growth of neural tissue into the hollow tip of a two-wire electrode (Kennedy 1989) The neural tissue is held firmly within the tip because it grows through both ends and joins with neighboring neuropil This has provided stable long-term recordings…”
MethodSelf-citationBrain-computer interfaces for communication and control
McFarland, D. J., & Wolpaw, J. R. (2011) · Communications of the ACM · doi:10.1145/1941487.1941506 · Cited by 519
Denby, B., Schultz, T., Honda, K., Hueber, T., Gilbert, J. M., & Brumberg, J. S. (2010) · Speech Communication · doi:10.1016/j.specom.2009.08.002 · Cited by 487
“Rather than utilizing many recording tips, the Neurotrophic Electrode utilizes few, low impedance wires, encased in a glass cone filled with a neurotrophic growth factor.”
BackgroundMethodInfluentialRestoration of neural output from a paralyzed patient by a direct brain connection
Kennedy, P. R., & Bakay, R. A. E. (1998) · NeuroReport · doi:10.1097/00001756-199806010-00007 · Cited by 475
Self-citationBrain-computer interface research at the Wadsworth Center
Wolpaw, J. R., McFarland, D. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847823 · Cited by 440
Progress towards biocompatible intracortical microelectrodes for neural interfacing applications
Jorfi, M., Skousen, J. L., Weder, C., & Capadona, J. R. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/011001 · Cited by 384
“(60) Kennedy’s electrode was built around a glass cone with a Teflon®-insulated gold wire.”
MethodSelecting the signals for a brain–machine interface
Andersen, R. A., Musallam, S., & Pesaran, B. (2004) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2004.10.005 · Cited by 332
“Nonetheless, advances in electrode design are showing promising results in extending single-cell recording time [37–39].”
BackgroundA Wireless Brain-Machine Interface for Real-Time Speech Synthesis
Guenther, F. H., Brumberg, J. S., Wright, E. J., Nieto-Castanon, A., Tourville, J. A., Panko, M., Law, R., Siebert, S. A., Bartels, J. L., Andreasen, D. S., et al. (2009) · PLoS ONE · doi:10.1371/journal.pone.0008218 · Cited by 306
“The electrode used in the current study was a Neurotrophic Electrode [17,18] designed for permanent human implantation.”
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
“Kennedy PR, Mirra SS, Bakay RA.”
BackgroundInfluentialBrain–computer interfaces for speech communication
Brumberg, J. S., Nieto-Castanon, A., Kennedy, P. R., & Guenther, F. H. (2010) · Speech Communication · doi:10.1016/j.specom.2010.01.001 · Cited by 267
“…(Nicolelis et al., 2003; Taylor et al., 2002; Williams et al., 1999), silicon planar arrays (Hoogerwerf and Wise, 1994; Wise et al., 1970), silicon etched arrays (Jones et al., 1992; Maynard et al., 1997; Rousche and Normann, 1998) and neurotrophic microwires (Kennedy, 1989; Kennedy et al., 1992b).”
BackgroundSelf-citation(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-52901-5.00006-x · Cited by 212
NeuroMEMS: Neural Probe Microtechnologies
HajjHassan, M., Chodavarapu, V., & Musallam, S. (2008) · Sensors · doi:10.3390/s8106704 · Cited by 190
Human Intracranial Recordings and Cognitive Neuroscience
Mukamel, R., & Fried, I. (2012) · Annual Review of Psychology · doi:10.1146/annurev-psych-120709-145401 · Cited by 182
“In a locked-in patient suffering from amyotrophic lateral sclerosis (ALS), Kennedy and colleagues (Kennedy & Bakay 1998) recorded action potentials from right motor cortex using a neurotrophic electrode (Bartels et al. 2008, Kennedy 1989).”
BackgroundMethodImplantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
“A derivative of this technology is the cone electrode design which consisted of a gold metal wire fixed inside a hollow glass cone [80, 81].”
Method3D Parylene sheath neural probe for chronic recordings
Kim, B. J., Kuo, J. T. W., Hara, S. A., Lee, C. D., Yu, L., Gutierrez, C. A., Hoang, T. Q., Pikov, V, & Meng, E. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045002 · Cited by 155
“1741-2560/13/045002+16$33.00 1 © 2013 IOP Publishing Ltd Printed in the UK & the USA”
InfluentialArticulating: the neural mechanisms of speech production
Kearney, E., & Guenther, F. H. (2019) · Language Cognition and Neuroscience · doi:10.1080/23273798.2019.1589541 · Cited by 183
“The BCI utilised an intracortical electrode (Bartels et al., 2008; Kennedy, 1989) permanently implanted in the speech motor cortex of a volunteer with locked-in syndrome.”
MethodBio-inspired electronics: Soft, biohybrid, and “living” neural interfaces
Boufidis, D., Garg, R., Angelopoulos, E., Cullen, D. K., & Vitale, F. (2025) · Nature Communications · doi:10.1038/s41467-025-57016-0 · Cited by 201
“First, the temporal gap between device implantation and the onset of physiologically relevant interactions with host tissues can take several weeks to months 143 , which is a signi fi cant hurdle.”
InfluentialA review for the peripheral nerve interface designer
Larson, C. E., & Meng, E. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2019.108523 · Cited by 133
Translational opportunities and challenges of invasive electrodes for neural interfaces
Shen, K., Chen, O., Edmunds, J. L., Piech, D. K., & Maharbiz, M. M. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01021-5 · Cited by 161
3D-nanostructured boron-doped diamond for microelectrode array neural interfacing
Piret, G., Hébert, C., Mazellier, J.-P., Rousseau, L., Scorsone, E., Cottance, M., Lissorgues, G., Heuschkel, M. O., Picaud, S., Bergonzo, P., et al. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2015.02.021 · Cited by 135
Computer control using human intracortical local field potentials
Kennedy, P. R., Kirby, M. T., Moore, M. M., King, B., & Mallory, A. (2004) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2004.834629 · Cited by 134
“placed inside the cone before cortical implantation [4].”
BackgroundSelf-citationRepeated voltage biasing improves unit recordings by reducing resistive tissue impedances
Johnson, M. D., Otto, K. J., & Kipke, D. R. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.847373 · Cited by 130
“methods have been proposed to inhibit the late reactive tissue response, including flexible probe substrates and ribbon cables [16], [17], bioactive factors [1], [18], [19], and peripheral and”
MethodNovel flexible Parylene neural probe with 3D sheath structure for enhancing tissue integration
Kuo, J. T. W., Kim, B. J., Hara, S. A., Lee, C. D., Gutierrez, C. A., Hoang, T. Q., & Meng, E. (2013) · Lab Chip · doi:10.1039/c2lc40935f · Cited by 127
The Development of Brain-Machine Interface Neuroprosthetic Devices
Patil, P. G., & Turner, D. A. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.11.002 · Cited by 140
Sensors for brain-computer interfaces
Hochberg, L. R., & Donoghue, J. P. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1705745 · Cited by 115
“Clinical Trials of Intracortical BCIs The first type of intracortical BCI (iBCI) implanted into humans was the “cone”—or “neurotrophic”—electrode, which contains two electrode wires in a glass enclosure [51].”
Brumberg (2011) · Frontiers in Neuroscience · doi:10.3389/fnins.2011.00065 · Cited by 114
“, 2007) and Neurotrophic Electrode (Kennedy, 1989; Kennedy et al., 1992a; Kennedy and Bakay, 1998).”
InfluentialNeurotrophic electrode: Method of assembly and implantation into human motor speech cortex
Bartels, J., Andreasen, D., Ehirim, P., Mao, H., Seibert, S., Wright, E. J., & Kennedy, P. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.06.030 · Cited by 108
“It achieves this by growing neurites into its tip and recording the electrical activity of these neurites via wires placed inside the tip (Kennedy, 1989).”
BackgroundSelf-citationThe sinusoidal probe: a new approach to improve electrode longevity
Sohal, H. S., Jackson, A., Jackson, R., Clowry, G. J., Vassilevski, K., O’Neill, A., & Baker, S. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00010 · Cited by 106
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 103
“Kennedy and colleagues were the first to implant electrodes into an individual with ALS [127] using a specialized electrode with two recording wires and a neurotrophic factor [85].”
MethodOptimizing recording capabilities of the Utah Intracortical Electrode Array
Nordhausen, C. T., Rousche, P. J., & Normann, R. A. (1994) · Brain Research · doi:10.1016/0006-8993(94)91213-0 · Cited by 100
Neurotrophin‐eluting hydrogel coatings for neural stimulating electrodes
Winter, J. O., Cogan, S. F., & Rizzo, J. F. (2007) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.30696 · Cited by 98
Intracortical Recording Interfaces: Current Challenges to Chronic Recording Function
Gunasekera, B., Saxena, T., Bellamkonda, R., & Karumbaiah, L. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn5002864 · Cited by 93
Brain-computer interfaces (BCIs) for communication and control
Wolpaw, J. R. (2007) · International ACM SIGACCESS Conference on Computers and Accessibility (ASSETS) · doi:10.1145/1296843.1296845 · Cited by 115
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 87
Bioinspired Materials for In Vivo Bioelectronic Neural Interfaces
Woods, G. A., Rommelfanger, N. J., & Hong, G. (2020) · Matter · doi:10.1016/j.matt.2020.08.002 · Cited by 91
Brain–Machine and Brain–Computer Interfaces
Friehs, G. M., Zerris, V. A., Ojakangas, C. L., Fellows, M. R., & Donoghue, J. P. (2004) · Stroke · doi:10.1161/01.str.0000143235.93497.03 · Cited by 86
He, B., Gao, S., Yuan, H., & Wolpaw, J. R. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5227-0_2 · Cited by 109
The cone electrode: Ultrastructural studies following long-term recording in rat and monkey cortex
Kennedy, P. R., Mirra, S. S., & Bakay, R. A. E. (1992) · Neuroscience Letters · doi:10.1016/0304-3940(92)90627-j · Cited by 81
Self-citationTonet, O., Marinelli, M., Citi, L., Rossini, P. M., Rossini, L., Megali, G., & Dario, P. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.03.015 · Cited by 94
In vivo evaluation of a neural stem cell-seeded prosthesis
Purcell, E. K., Seymour, J. P., Yandamuri, S., & Kipke, D. R. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026005 · Cited by 76
Regenerative Electrode Interfaces for Neural Prostheses.
Thompson, C. H., Zoratti, M. J., Langhals, N. B., & Purcell, E. K. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0279 · Cited by 67
“82 Following its initial description in 1989, several additional reports have validated the ability to obtain long-term recordings using cone electrode-based devices: signals were successfully recorded in rats and nonhuman primates, 83,84 and recordings were obtained for several years in human…”
Bioactive properties of nanostructured porous silicon for enhancing electrode to neuron interfaces
Moxon, K. A., Hallman, S., Aslani, A., Kalkhoran, N. M., & Lelkes, P. I. (2007) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856207782177882 · Cited by 68
Brain-computer interfaces for communication
Vansteensel, M. J., & Jarosiewicz, B. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00007-x · Cited by 85
“…a later offline classification study from the same group, using the neural activity recorded from a single two-channel neurotrophic cone electrode (Kennedy, 1989) implanted in a motor speech production area, it was possible to decode with 16% – 21% accuracy which one of 38 phonemes a study…”
MethodMussa-Ivaldi, S. (2000) · Nature · doi:10.1038/35042670 · Cited by 64
Hara, S. A., Kim, B. J., Kuo, J. T. W., Lee, C. D., Meng, E., & Pikov, V. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/6/066020 · Cited by 57
Making the lifetime connection between brain and machine for restoring and enhancing function
Kennedy, P., Andreasen, D., Bartels, J., Ehirim, P., Mao, H., Velliste, M., Wichmann, T., & Wright, J. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00020-0 · Cited by 54
“NEs consist of ultrathin Teflon-coated gold wires whose tips are ensheathed in a small cone-shaped glass enclosure which contains neurotrophic factors (Kennedy, 1989).”
BackgroundSelf-citationThe Electrochemistry of Charge Injection at the Electrode/Tissue Interface
Merrill, D. R. (2010) · Biological and medical physics series · doi:10.1007/978-0-387-98120-8_4 · Cited by 68
“In further advancements, bioactive components have been added to the electrode to direct neurite growth toward the electrode, minimizing the distance between the electrode and stimulated tissue [42, 43, 44].”
BackgroundChapter 63 Development of neuromotor prostheses for humans
Donoghue, J. P., Nurmikko, A. V., Friehs, G. M., & Black, M. J. (2004) · Supplements to Clinical neurophysiology · doi:10.1016/s1567-424x(09)70399-x · Cited by 64
Bioactive Neuroelectronic Interfaces
Adewole, D. O., Serruya, M. D., Wolf, J. A., & Cullen, D. K. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00269 · Cited by 53
Brain-Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01621-9 · Cited by 44
Biohybrid neural interfaces: improving the biological integration of neural implants
Boulingre, M., Lara, R. P., & Green, R. A. (2023) · Chemical Communications · doi:10.1039/d3cc05006h · Cited by 44
Matrigel coatings forParylene sheath neural probes
Lee, C. D., Hara, S. A., Yu, L., Kuo, J. T. W., Kim, B. J., Hoang, T., Pikov, V., & Meng, E. (2016) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33390 · Cited by 35
Electroresponsive Hydrogels for Therapeutic Applications in the Brain
Khan, Z. M., Wilts, E. M., Vlaisavljevich, E., Long, T. E., & Verbridge, S. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202100355 · Cited by 40
Activity of single action potentials in monkey motor cortex during long-term task learning
Kennedy, P. R., & Bakay, R. A. E. (1997) · Brain Research · doi:10.1016/s0006-8993(97)00051-6 · Cited by 34
Self-citationMultiple single-unit recordings from the CNS using thin-film electrode arrays
Carter, R. R., & Houk, J. C. (1993) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.279266 · Cited by 34
Advances in Retinal Neuroprosthetics
Lovell, N. H., Hallum, L. E., Chen, S. C., Dokos, S., Byrnes‐Preston, P., Green, R., Poole‐Warren, L., Lehmann, T., & Suaning, G. J. (2006) · Handbook of Neural Engineering · doi:10.1002/9780470068298.ch20 · Cited by 33
“performance of the neural implant [73-76].”
Frazier, A. B., O'Brien, D. P., & Allen, M. G. (2002) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1993.296923 · Cited by 37
He, W. J., & Bellamkonda, R. V. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.pt4 · Cited by 34
Direct brain-computer communication through scalp recorded EEG signals
Garcia‐Molina, G. (2004) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-3019 · Cited by 40
Brain Signals for Brain–Computer Interfaces
Wolpaw, J. R., & Boulay, C. (2009) · The frontiers collection · doi:10.1007/978-3-642-02091-9_2 · Cited by 35
Cao, Y., & He, W. J. (2010) · Biomacromolecules · doi:10.1021/bm100095t · Cited by 29
Functional and Histological Effects of Chronic Neural Electrode Implantation
Sahyouni, R., Chang, D. T., Moshtaghi, O., Mahmoodi, A., Djalilian, H. R., & Lin, H. W. (2017) · Laryngoscope Investigative Otolaryngology · doi:10.1002/lio2.66 · Cited by 33
Multi-site incorporation of bioactive matrices into MEMS-based neural probes
Williams, J. C., Holecko, M. M., Massia, S. P., Rousche, P. J., & Kipke, D. R. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/l03 · Cited by 30
“The major benefit of the work is to extend the design parameters of chronic implantable neural interface devices, giving the researcher greater control over multiple aspects of probe functionality.”
BackgroundBiological Considerations of Optical Interfaces for Neuromodulation
Hart, W. L., Kameneva, T., Wise, A. K., & Stoddart, P. R. (2019) · Advanced Optical Materials · doi:10.1002/adom.201900385 · Cited by 26
Materials considerations of implantable neuroengineering devices for clinical use
Merrill, D. R. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.002 · Cited by 29
Current Challenges to the Clinical Translation of Brain Machine Interface Technology
Lu, C. W., Patil, P. G., & Chestek, C. A. (2012) · International review of neurobiology · doi:10.1016/b978-0-12-404706-8.00008-5 · Cited by 26
“Such electrodes have potential recording lifetimes of years or longer (Kennedy, 1989; Kennedy, Mirra, & Bakay, 1992).”
Visualization of the intact interface between neural tissue and implanted microelectrode arrays
Holecko, M. M., Williams, J. C., & Massia, S. P. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/005 · Cited by 25
“…includes: gaining a better understanding of the functions of individual neurons and complex neural networks [1–3]; providing an interface between the central nervous system and prosthetics interacting with the environment [1–5] and treating various neurological disorders via drug delivery [6].”
BackgroundBrain–Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.2200/s00053ed1v01y200710bme017 · Cited by 33
Development of speech prostheses: current status and recent advances
Brumberg, J. S., & Guenther, F. H. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.34 · Cited by 26
“Motor cortex extracellular microelectrode: direct phoneme prediction—Kennedy and colleagues made initial investigations into phoneme prediction using intracortical microelectrode recordings, [80–82] with the goal of predicting 39 English phonemes (and subsets) from single and multiunit activity using the Neurotrophic…”
BackgroundMethodInfluentialBrandman, D. M., & Hochberg, L. R. (2016) · Wiley eBooks · doi:10.1002/9781118816028.ch9 · Cited by 23
Artificial speech synthesizer control by brain-computer interface
Brumberg, J. S., Kennedy, P. R., & Guenther, F. H. (2009) · Interspeech (USB) · doi:10.21437/interspeech.2009-225 · Cited by 22
“It utilizes a wireless intracortical microelectrode [9,10] to obtain neural activity related to speech production, maps it into the speech domain through a “neural decoder” and synthesizes instantaneous auditory feedback in less than 50 ms.”
BackgroundMethodInfluentialSelf-citationGearing, M., & Kennedy, P. (2020) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2020.00111 · Cited by 21
Self-citationThe Future of Biohybrid Regenerative Bioelectronics
Carnicer‐Lombarte, A., Malliaras, G. G., & Barone, D. G. (2024) · Advanced Materials · doi:10.1002/adma.202408308 · Cited by 25
Moxon, K. A., Hallman, S. J., Sundarakrishnan, A., Wheatley, M. A., Nissanov, J., & Barbee, K. A. (2009) · Materials · doi:10.3390/ma2041762 · Cited by 17
“Finally, it has been shown that electrodes produced with neurotrophic factors can reliably record single neurons from human patients and other primates and used to allow patients to control a cursor [10,93–95].”
BackgroundRezvani, S., Hosseini-Zahraei, S., Tootchi, A., Guger, C., Chaibakhsh, Y., Saberi, A., & Chaibakhsh, A. (2023) · Cognitive Neurodynamics · doi:10.1007/s11571-023-09995-3 · Cited by 25
“…intracortical BCIs (iBCIs) for non-human primates (NHPs), the first case that was implanted into humans (Kennedy and Bakay 1998; Kennedy et al. 2000) was the electrode with an insulated gold wire fixed inside a hollow glass cone earlier introduced (Kennedy 1989) by Philip R. Kennedy in 1989.”
Stieglitz, T. (2007) · Springer eBooks · doi:10.1007/978-3-211-33079-1_57 · Cited by 20
“Another biohybrid interface was introduced as ‘‘cone electrode’’ [ 8 ].”
Schouenborg, J. (2011) · Progress in brain research · doi:10.1016/b978-0-444-53815-4.00017-0 · Cited by 19
Kennedy, P. (2011) · Neurocase · doi:10.1080/13554794.2010.532137 · Cited by 20
“Assembly and implantation instructions for the electrode have recently been described (Bartels et al., 2008; Kennedy, 1989).”
BackgroundMethodSelf-citationDESIGN PRINCIPLES OF A NEUROMOTOR PROSTHETIC DEVICE
Serruya, M. D., & Donoghue, J. P. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0040 · Cited by 21
Designing a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A. (2000) · doi:10.1201/9781420039054-13 · Cited by 17
Intracortical brain-computer interfaces in primates: a review and outlook
Rouzitalab, A., Boulay, C., Park, J., & Sachs, A. J. (2023) · Biomedical Engineering Letters · doi:10.1007/s13534-023-00286-8 · Cited by 16
Electrodes for the Neural Interface
Tyler, D. J., & Polasek, K. H. (2009) · Elsevier eBooks · doi:10.1016/b978-0-12-374248-3.00018-5 · Cited by 17
An Auditory Output Brain–Computer Interface for Speech Communication
Brumberg, J. S., Guenther, F. H., & Kennedy, P. R. (2013) · Springer briefs in electrical and computer engineering · doi:10.1007/978-3-642-36083-1_2 · Cited by 13
“The speech synthesis BCI consists of (1) an extracellular microelectrode (Bartels et al. 2008; Kennedy 1989) implanted in the speech motor cortex (2) a Kalman filter decoding mechanism and (3) a formant-based speech synthesizer.”
MethodSelf-citationKennedy, P., & King, B. (2000) · Frontiers in neuroscience · doi:10.1201/9781420039054.ch7 · Cited by 13
Self-citationThe use of ALGEL/spl reg/ as an artificial dura for chronic cortical implant neuroprosthetics
Vetter, R. J., Becker, T. A., Williams, J. C., & Kipke, D. R. (2004) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/cne.2003.1196908 · Cited by 12
Design of electrodes for stimulation and recording
Howell, B. L., & Grill, W. M. (2015) · Elsevier eBooks · doi:10.1016/b978-1-78242-101-6.00004-5 · Cited by 12
The Electrode – Materials and Configurations
Merrill, D. R. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-381409-8.00006-1 · Cited by 11
Designing a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A., Morizio, J., Chapin, J. K., Nicolelis, M. A. L., & Wolf, P. (2000) · Frontiers in neuroscience · doi:10.1201/9781420039054.pt2 · Cited by 11
Blagojevic, A., Seche, W., Choi, H., Davis, S. L., Elyahoodayan, S., Caputo, G. A., Lowe, T. C., Tavousi, P., Shahbazmohamadi, S., & Amini, S. (2024) · Advanced Materials Interfaces · doi:10.1002/admi.202400017 · Cited by 8
Wireless interfaces for brain neurotechnologies
Kim, H., & Ho, J. S. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0020 · Cited by 18
The voltammetric response of a conical electrode
Sokirko, A. V., & Oldham, K. B. (1997) · Journal of Electroanalytical Chemistry · doi:10.1016/s0022-0728(96)04909-1 · Cited by 8
Metadata
- Authors
- Kennedy, P. R.
- Affiliations
- Georgia Institute of Technology (US)
- Corresponding author
- Kennedy, Philip R.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1989-09
- Volume
- 29
- Issue
- 3
- Pages
- 181-193
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2157708132
- Semantic Scholar
- 17460106e1a422b5bba53a39a2763b837d5f7654
- Cited by
- 151
- References
- 34
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 4 · 2023: 5 · 2022: 5 · 2021: 2 · 2020: 3 · 2019: 5 · 2018: 1 · 2017: 5 · 2016: 5 · 2015: 12 · 2014: 7 · 2013: 7 · 2012: 7
- FWCI
- 0.27
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Nerve injury and regeneration
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neuropharmacology Research
- Keywords
- long-term neural recording, neurite outgrowth, sciatic nerve, nerve regeneration, single-unit recording, multi-unit recording, neuroplasticity, motor learning, neural correlates of behavior, paralysis, neuroprosthetics
- MeSH terms
- Animals, Axons, Cerebral Cortex, Electrophysiology, Microelectrodes, Nerve Growth Factors, Nerve Regeneration, Sciatic Nerve, Prostheses and Implants, Rats
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.