An approach to correlate tandem mass spectral data of peptides with amino acid sequences in a protein database
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
A method to correlate the uninterpreted tandem mass spectra of peptides produced under low energy (10-50 eV) collision conditions with amino acid sequences in the Genpept database has been developed. In this method the protein database is searched to identify linear amino acid sequences within a mass tolerance of ±1 u of the precursor ion molecular weight A cross-correlation function is then used to provide a measurement of similarity between the mass-to-charge ratios for the fragment ions predicted from amino acid sequences obtained from the database and the fragment ions observed in the tandem mass spectrum. In general, a difference greater than 0.1 between the normalized cross-correlation functions of the first- and second-ranked search results indicates a successful match between sequence and spectrum. Searches of species-specific protein databases with tandem mass spectra acquired from peptides obtained from the enzymatically digested total proteins of E. coli and S. cerevisiae cells allowed matching of the spectra to amino acid sequences within proteins of these organisms. The approach described in this manuscript provides a convenient method to interpret tandem mass spectra with known sequences in a protein database.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“However, the standard paradigm of proteomic analysis, the “bottom-up” strategy pioneered by Eng and Yates some 20 years ago (4), does not directly identify proteoforms.”
From Proteoforms as the next proteomics currency (2018) · cites this paper as [4]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Colowick, S. P., Joshi, M. D., Jagannathan, & KAPLAN, N. O. (1966) · Cited by 26,137
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Edman, P., & Begg, G. (1967) · European Journal of Biochemistry · doi:10.1111/j.1432-1033.1967.tb00047.x · Cited by 2,845
A gas-liquid solid phase peptide and protein sequenator.
Hewick, R. M., Hunkapiller, M. W., Hood, L. E., & Dreyer, W. J. (1981) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)43377-7 · Cited by 2,218
[5] Rapid and sensitive sequence comparison with FASTP and FASTA
Pearson, W. R. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)83007-v · Cited by 1,946
Rapid identification of proteins by peptide-mass fingerprinting
Pappin, D. J. C., Hojrup, P., & Bleasby, A. J. (1993) · Current Biology · doi:10.1016/0960-9822(93)90195-t · Cited by 1,615
Henzel, W. J., Billeci, T. M., Stults, J. T., Wong, S. C., Grimley, C., & Watanabe, C. (1993) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.90.11.5011 · Cited by 1,305
Characterization of Peptides Bound to the Class I MHC Molecule HLA-A2.1 by Mass Spectrometry
Hunt, D. F., Henderson, R. A., Shabanowitz, J., Sakaguchi, K., Michel, H., Sevilir, N., Cox, A. L., Appella, E., & Engelhard, V. H. (1992) · Science · doi:10.1126/science.1546328 · Cited by 1,198
Sequence analysis of peptides bound to MHC class II molecules
Rudensky, A. Y., Preston-Hurlburt, P., Hong, S.-C., Barlow, A., & Janeway, C. A. (1991) · Nature · doi:10.1038/353622a0 · Cited by 1,075
Use of mass spectrometric molecular weight information to identify proteins in sequence databases
Mann, M., Højrup, P., & Roepstorff, P. (1993) · Biological Mass Spectrometry · doi:10.1002/bms.1200220605 · Cited by 931
Research works printed but not linked: 3
- 4. Doolittle, R. F. In Methods in Enzymology, Vol. 183; Doolittle, R. F., Ed.; Academic: San Diego, 1990; pp 99–110.
- 36. Stahl, D. C.; Martino, P. A.; Swiderek, K. M.; Davis, M. T.; Lee, T. D. Proceedings of the 40th ASMS Conference on Mass Spectrometry and Allied Topics; Washington DC, 1992; pp 1801-1802.
- 39. Kasier, R. E., Jr.; Cooks, R. G.; Syka, J. E. P.; Stafford, G. C., Jr. Rapid Mass Spectrom. 1990, 4, 30–33.
Cited by
Items 501–600 of 1,079
Weatherly, D. B., Atwood, J. A., Minning, T. A., Cavola, C., Tarleton, R. L., & Orlando, R. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400215-mcp200 · Cited by 210
Large-scale protein identification using mass spectrometry
Lin, D., Tabb, D. L., & Yates, J. R. (2003) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/s1570-9639(02)00546-0 · Cited by 210
Self-citationBrand, M., Ranish, J. A., Kummer, N. T., Hamilton, J., Igarashi, K., Francastel, C., Chi, T. H., Crabtree, G. R., Aebersold, R., & Groudine, M. (2004) · Nature Structural & Molecular Biology · doi:10.1038/nsmb713 · Cited by 210
Automatic Quality Assessment of Peptide Tandem Mass Spectra
Bern, M., Goldberg, D., McDonald, W. H., & Yates, J. R. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth947 · Cited by 210
“This algorithm can be used to prefilter spectra so that only reasonably good spectra are sent to time-consuming, database-search identification programs, such as SEQUEST (Eng et al., 1994) and Mascot (Perkins et al., 1999).”
MethodInfluentialSelf-citationSrivastava, S., Swanson, S. K., Manel, N., Florens, L., Washburn, M. P., & Skowronski, J. (2008) · PLoS Pathogens · doi:10.1371/journal.ppat.1000059 · Cited by 209
“Tandem mass (MS/MS) spectra were interpreted using SEQUEST [37] against a database of 82242 sequences, consisting of hfa-tagged SIVmac Vpx, usual contaminants, and 40873 human proteins, as well as, to estimate false discovery rates, randomized amino acid sequences derived from each non-redundant protein entry.”
MethodWeighing in on ubiquitin: the expanding role of mass-spectrometry-based proteomics
Kirkpatrick, D. S., Denison, C., & Gygi, S. P. (2005) · Nature Cell Biology · doi:10.1038/ncb0805-750 · Cited by 209
“2a ), peptides are 'sequenced' by the correlation of each MS/MS spectrum against a sequence database using softwar”
MethodPage, M. J., Amess, B., Townsend, R. R., Parekh, R., Herath, A., Brusten, L., Zvelebil, M. J., Stein, R. C., Waterfield, M. D., Davies, S. C., et al. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.22.12589 · Cited by 209
Cdk1-Dependent Regulation of the Mitotic Inhibitor Wee1
Harvey, S. L., Charlet, A., Haas, W., Gygi, S. P., & Kellogg, D. R. (2005) · Cell · doi:10.1016/j.cell.2005.05.029 · Cited by 208
Adam, P. J., Boyd, R., Tyson, K. L., Fletcher, G. C., Stamps, A., Hudson, L., Poyser, H. R., Redpath, N., Griffiths, M., Steers, G., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m210184200 · Cited by 208
Quantitative proteome analysis using isotope-coded affinity tags and mass spectrometry
Shiio, Y., & Aebersold, R. (2006) · Nature Protocols · doi:10.1038/nprot.2006.22 · Cited by 208
“) ICAT Avidin Cartridge (Applied Biosystems) SpeedVac centrifugal vacuum concentrator ( Thermo Electron ) Electrospray-ionization ion-trap tandem mass spectrometer ( Thermo Finnigan LCQ-classic , LCQ-deca or LTQ ; most other types of tandem mass spectrometers can also support the method) Reverse-phase column : C18 AQ…”
Global site-specific N-glycosylation analysis of HIV envelope glycoprotein
Cao, L., Diedrich, J. K., Kulp, D. W., Pauthner, M., He, L., Park, S.-K. R., Sok, D., Su, C. Y., Delahunty, C. M., Menis, S., et al. (2017) · Nature Communications · doi:10.1038/ncomms14954 · Cited by 207
“Peptides were identified using ProLuCID 43–46 .”
Self-citationThe Rheumatoid Arthritis-Associated Citrullinome
Tilvawala, R., Nguyen, S. H., Maurais, A. J., Nemmara, V. V., Nagar, M., Salinger, A. J., Nagpal, S., Weerapana, E., & Thompson, P. R. (2018) · Cell Chemical Biology · doi:10.1016/j.chembiol.2018.03.002 · Cited by 207
Radulovic, D., Jelveh, S., Ryu, S., Hamilton, T. G., Foss, E., Mao, Y., & Emili, A. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m400061-mcp200 · Cited by 207
“Peptide fragmentation product ion spectra were sequencemapped against a database of nonredundant protein sequences (Swiss-Prot) using the SEQUEST software algorithm (30) running on a multiprocessor computer.”
MethodQuadroni, M., & James, P. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19990101)20:4/5<664::aid-elps664>3.0.co;2-a · Cited by 241
Laliberte, R. E., Perregaux, D. G., Hoth, L. R., Rosner, P. J., Jordan, C. K., Peese, K. M., Eggler, J. F., Dombroski, M. A., Geoghegan, K. F., & Gabel, C. A. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m211596200 · Cited by 206
Simpson, R. J., Connolly, L. M., Eddes, J. S., Pereira, J. J., Moritz, R. L., & Reid, G. E. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000501)21:9<1707::aid-elps1707>3.0.co;2-q · Cited by 206
Zhang, J., Harnpicharnchai, P., Jakovljevic, J., Tang, L., Guo, Y., Oeffinger, M., Rout, M. P., Hiley, S. L., Hughes, T., & Woolford, J. L. (2007) · Genes & Development · doi:10.1101/gad.1569307 · Cited by 205
“1A; Fatica and Tollervey 2002; FromontRacine et al. 2003; Raué 2003; Granneman and Baserga 2004).”
Proteomic analysis of Schistosoma mansoni egg secretions
Cass, C. L., Johnson, J. R., Califf, L. L., Xu, T., Hernandez, H. J., Stadecker, M. J., Yates, J. R., & Williams, D. L. (2007) · Molecular and Biochemical Parasitology · doi:10.1016/j.molbiopara.2007.06.002 · Cited by 205
“Mass spectra, generated by LC/LC–MS/MS analysis of ESP, were assigned peptide identities based upon similarity to predicted fragmentation patterns of protein sequences by the SEQUEST algorithm [27].”
InfluentialSelf-citationGuide for protein fold change and p -value calculation for non-experts in proteomics
Aguilan, J. T., Kulej, K., & Sidoli, S. (2020) · Molecular Omics · doi:10.1039/d0mo00087f · Cited by 204
Salivary Proteome and Its Genetic Polymorphisms
OPPENHEIM, F. G., SALIH, E., SIQUEIRA, W. L., ZHANG, W., & HELMERHORST, E. J. (2007) · Annals of the New York Academy of Sciences · doi:10.1196/annals.1384.030 · Cited by 204
cAMP-dependent Tyrosine Phosphorylation of Subunit I Inhibits Cytochrome c Oxidase Activity
Lee, I., Salomon, A. R., Ficarro, S., Mathes, I., Lottspeich, F., Grossman, L. I., & Hüttemann, M. (2005) · Journal of Biological Chemistry · doi:10.1074/jbc.m411335200 · Cited by 204
Lange, V., Malmström, J. A., Didion, J., King, N. L., Johansson, B. P., Schäfer, J., Rameseder, J., Wong, C.-H., Deutsch, E. W., Brusniak, M.-Y., et al. (2008) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m800032-mcp200 · Cited by 204
“MS/MS spectra were searched using SEQUEST (version 27, revision 0) (25) against the predicted proteome from S.”
MethodCosta, K. C., Wong, P. M., Wang, T., Lie, T. J., Dodsworth, J. A., Swanson, I., Burn, J. A., Hackett, M., & Leigh, J. A. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1003653107 · Cited by 203
“All Sequest and DTASelect adjustable parameters were set as described (6, 7).”
MethodProtein identification using MS/MS data
Cottrell, J. S. (2011) · Journal of Proteomics · doi:10.1016/j.jprot.2011.05.014 · Cited by 202
“A review by Sadygov [31] classified scoring algorithms as Descriptive (e.g. Sequest [14], Sonar [32]), Interpretative (e.g. PeptideSearch [9], MS-Seq [33]), Stochastic (e.g. Scope [34], Olav [35]), and Probability-based (e.g. Mascot [36], OMSSA [37]).”
MethodLiu, J., Wang, Z., Belchik, S. M., Edwards, M. J., Liu, C., Kennedy, D. W., Merkley, E. D., Lipton, M. S., Butt, J. N., Richardson, D. J., et al. (2012) · Frontiers in Microbiology · doi:10.3389/fmicb.2012.00037 · Cited by 202
“12 (Eng et al., 1994), with parent mass tolerance, 50 ppm; fragment mass tolerance, 0.5 Da; partially tryptic enzyme rules; a dynamic modification on cysteine (C) residues of 615.1694 (Yang et al., 2005), corresponding to the mass of a heme C group containing 56Fe and accounting for the charge on…”
BackgroundInfluentialWoo, S.-Y., Kim, D.-H., Jun, C.-B., Kim, Y.-M., Haar, E. V., Lee, S.-I., Hegg, J. W., Bandhakavi, S., Griffin, T. J., & Kim, D.-H. (2007) · Journal of Biological Chemistry · doi:10.1074/jbc.m704343200 · Cited by 202
Ordureau, A., Paulo, J. A., Zhang, J., An, H., Swatek, K. N., Cannon, J. R., Wan, Q., Komander, D., & Harper, J. W. (2020) · Molecular Cell · doi:10.1016/j.molcel.2019.11.013 · Cited by 202
“N/A SEQUEST Eng et al., 1994 N/A Comet Eng et al., 2013 http://comet-ms.sourceforge.net/ Perseus Tyanova et al., 2016 13:731-40. http://maxquant.net/perseus/ FiJi ImageJ V.2.0.0 https://imagej.net/Fiji ImageStudioLite V 5.2.5 https://www.licor.com/bio/image- studio-lite/ Other Orbitrap Fusion Lumos…”
InfluentialDe novo sequencing of peptides using MALDI/TOF-TOF
Yergey, A. L., Coorssen, J. R., Backlund, P. S., Blank, P. S., Humphrey, G. A., Zimmerberg, J., Campbell, J. M., & Vestal, M. L. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00393-8 · Cited by 202
Pancreatic Cancer Proteome: The Proteins That Underlie Invasion, Metastasis, and Immunologic Escape
Chen, R., Yi, E. C., Donohoe, S., Pan, S., Eng, J., Cooke, K., Crispin, D. A., Lane, Z., Goodlett, D. R., Bronner, M. P., et al. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.08.001 · Cited by 202
Self-citationKleiner, M., Wentrup, C., Lott, C., Teeling, H., Wetzel, S., Young, J., Chang, Y.-J., Shah, M., VerBerkmoes, N. C., Zarzycki, J., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1121198109 · Cited by 202
Cytosolic O‐glycosylation is abundant in nerve terminals
Cole, R. N., & Hart, G. W. (2001) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2001.00655.x · Cited by 201
Systematical Optimization of Reverse-Phase Chromatography for Shotgun Proteomics
Xu, P., Duong, D. M., & Peng, J. (2009) · Journal of Proteome Research · doi:10.1021/pr900251d · Cited by 201
Hashimoto, K., Eckert, C., Anschütz, U., Scholz, M., Held, K., Waadt, R., Reyer, A., Hippler, M., Becker, D., & Kudla, J. (2012) · Journal of Biological Chemistry · doi:10.1074/jbc.m111.279331 · Cited by 201
Segarini, P. R., Nesbitt, J. E., Li, D., Hays, L. G., Yates, J. R., & Carmichael, D. F. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m105180200 · Cited by 201
Self-citationLabel-free quantification in clinical proteomics
Megger, D. A., Bracht, T., Meyer, H. E., & Sitek, B. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.04.001 · Cited by 200
“Widely used search engines are MASCOT [68], SEQUEST [69], OMSSA [70] and X!TANDEM [71].”
MethodPerez‐Riverol, Y., Alpi, E., Wang, R., Hermjakob, H., & Vizcaíno, J. A. (2015) · PROTEOMICS · doi:10.1002/pmic.201400302 · Cited by 200
“MS/MS data obtained from all different experiments were searched against the Human RefSeq database using SE-QUEST [110] and MASCOT [56] through the Proteome Dis-coverer platform (Thermo Fisher Scientific).”
MethodRapid Prediction of Electron–Ionization Mass Spectrometry Using Neural Networks
Wei, J. N., Belanger, D., Adams, R. P., & Sculley, D. (2019) · ACS Central Science · doi:10.1021/acscentsci.9b00085 · Cited by 199
Han, G., Ye, M., Zhou, H., Jiang, X., Feng, S., Jiang, X., Tian, R., Wan, D., Zou, H., & Gu, J. (2008) · PROTEOMICS · doi:10.1002/pmic.200700884 · Cited by 199
Cryo-EM structure of a neuronal functional amyloid implicated in memory persistence in Drosophila
Hervas, R., Rau, M. J., Park, Y., Zhang, W., Murzin, A. G., Fitzpatrick, J. A. J., Scheres, S. H. W., & Si, K. (2020) · Science · doi:10.1126/science.aba3526 · Cited by 199
Morris, J. H., Knudsen, G. M., Verschueren, E., Johnson, J. R., Cimermancic, P., Greninger, A. L., & Pico, A. R. (2014) · Nature Protocols · doi:10.1038/nprot.2014.164 · Cited by 198
“Common packages include commercially licensed Mascot 51 and SEQUEST 52 , and open-source MaxQuant 53 , X!”
Proteomics characterization of exosome cargo
Schey, K. L., Luther, J. M., & Rose, K. L. (2015) · Methods · doi:10.1016/j.ymeth.2015.03.018 · Cited by 198
“Tandem mass spectra are subsequently searched against protein sequence databases using software tools such as Sequest [20], Mascot [21], X!Tandem [22], and Andromeda/MaxQuant [23] to identify the eluted peptides.”
Influentialvan Baar, B. L. M. (2000) · FEMS Microbiology Reviews · doi:10.1016/s0168-6445(99)00036-4 · Cited by 197
“coli with subsequent database-aided identi¢cation of protein fragments [122] has not seen much following.”
BackgroundXiao, K., Sun, J., Kim, J., Rajagopal, S., Zhai, B., Villén, J., Haas, W., Kovacs, J. J., Shukla, A. K., Hara, M. R., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1008461107 · Cited by 197
“algorithm (28) against a composite database containing the human In-”
BackgroundLi, W., Li, Y., Kedersha, N., Anderson, P., Emara, M., Swiderek, K. M., Moreno, G. T., & Brinton, M. A. (2002) · Journal of Virology · doi:10.1128/jvi.76.23.11989-12000.2002 · Cited by 197
“to identify the protein from which the peptides were generated (16).”
BackgroundSCOPE: a probabilistic model for scoring tandem mass spectra against a peptide database
Bafna, V., & Edwards, N. J. (2001) · Bioinformatics · doi:10.1093/bioinformatics/17.suppl_1.s13 · Cited by 208
“Eng et al. (1994) introduce the notion of discrete correlation, which corrects this score by subtracting the mean of a cross-correlation function.”
BackgroundMethodInfluentialMahrour, N., Redwine, W. B., Florens, L., Swanson, S. K., Martin-Brown, S., Bradford, W. D., Staehling-Hampton, K., Washburn, M. P., Conaway, R. C., & Conaway, J. W. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m706987200 · Cited by 196
Noncanonical open reading frames encode functional proteins essential for cancer cell survival
Prensner, J. R., Enache, O. M., Luria, V., Krug, K., Clauser, K. R., Dempster, J. M., Karger, A., Wang, L., Stumbraite, K., Wang, V. M., et al. (2021) · Nature Biotechnology · doi:10.1038/s41587-020-00806-2 · Cited by 196
A protein phosphatase functions to recycle RNA polymerase II
Cho, H., Kim, T.-K., Mancebo, H., Lane, W. S., Flores, O., & Reinberg, D. (1999) · Genes & Development · doi:10.1101/gad.13.12.1540 · Cited by 196
“Interpretation of the resulting MS/MS spectra of the peptides was facilitated by the database correlation with the algorithm SEQUEST and by programs developed in the Harvard Microchemistry Facility (Eng et al. 1994; Chittum et al. 1998).”
MethodDe Novo Peptide Sequencing and Identification with Precision Mass Spectrometry
Frank, A. M., Savitski, M. M., Nielsen, M. L., Zubarev, R. A., & Pevzner, P. A. (2007) · Journal of Proteome Research · doi:10.1021/pr060271u · Cited by 196
Chen, C.-W., Yang, Y.-W., Lur, H.-S., Tsai, Y.-G., & Chang, M.-C. (2006) · Plant and Cell Physiology · doi:10.1093/pcp/pci216 · Cited by 195
“…nlm.nih.gov/), KOME (http://cdna01.dna.affrc.go.jp/cDNA/) and TIGR (http://tigrblast.tigr.org/tgi/) databases using the SEQUEST Blowser software (Eng et al. 1994, Chittum et al. 1998). from https://academic.oup.com/pcp/article-abstract/47/1/1/1867452 2018 Downloaded by guest on 26 July”
Moreno, C. S., Park, S., Nelson, K., Ashby, D., Hubalek, F., Lane, W. S., & Pallas, D. C. (2000) · Journal of Biological Chemistry · doi:10.1074/jbc.275.8.5257 · Cited by 194
JUMP: a tag-based database search tool for peptide identification with high sensitivity and accuracy
Wang, X., Li, Y., Wu, Z., Wang, H., Tan, H., & Peng, J. (2014) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o114.039586 · Cited by 194
“During MS/MS preprocessing, the top 10 peaks in each window of 100 m / z were selected for SEQUEST, Mascot, and JUMP.”
MethodInfluentialShanks, N. F., Savas, J. N., Maruo, T., Cais, O., Hirao, A., Oe, S., Ghosh, A., Noda, Y., Greger, I. H., Yates, J. R., et al. (2012) · Cell Reports · doi:10.1016/j.celrep.2012.05.004 · Cited by 194
Self-citationDamage-induced phosphorylation of Sld3 is important to block late origin firing
Lopez-Mosqueda, J., Maas, N. L., Jonsson, Z. O., DeFazio-Eli, L. G., Wohlschlegel, J., & Toczyski, D. P. (2010) · Nature · doi:10.1038/nature09377 · Cited by 194
The nuclear envelope proteome differs notably between tissues
Korfali, N., Wilkie, G. S., Swanson, S. K., Srsen, V., de las Heras, J., Batrakou, D. G., Malik, P., Zuleger, N., Kerr, A. R. W., Florens, L., et al. (2012) · Nucleus · doi:10.4161/nucl.22257 · Cited by 194
Identification and characterization of the human ARD1–NATH protein acetyltransferase complex
ARNESEN, T., ANDERSON, D., BALDERSHEIM, C., LANOTTE, M., VARHAUG, J. E., & LILLEHAUG, J. R. (2005) · Biochemical Journal · doi:10.1042/bj20041071 · Cited by 194
Molecular Dynamics of the Shewanella oneidensis Response to Chromate Stress
Brown, S. D., Thompson, M. R., VerBerkmoes, N. C., Chourey, K., Shah, M., Zhou, J., Hettich, R. L., & Thompson, D. K. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500394-mcp200 · Cited by 193
“DTA files are the required format for input into SEQUEST (see Ref.”
MethodInfluentialTurró, S., Ingelmo‐Torres, M., Estanyol, J. M., Tebar, F., Fernández, M. A., Albor, C. V., Gaus, K., Grewal, T., Enrich, C., & Pol, A. (2006) · Traffic · doi:10.1111/j.1600-0854.2006.00465.x · Cited by 193
“The MS/MS acquired data searches were performed out with SEQUEST (53) (Thermo Finnigan Corporation) against amino acid sequences listed in the International Protein Index (IPI.fasta) of protein database of the EBI.”
MethodSperm chromatin proteomics identifies evolutionarily conserved fertility factors
Chu, D. S., Liu, H., Nix, P., Wu, T. F., Ralston, E. J., Yates III, J. R., & Meyer, B. J. (2006) · Nature · doi:10.1038/nature05050 · Cited by 193
Self-citationProteomics Analysis Unravels the Functional Repertoire of Coronavirus Nonstructural Protein 3
Neuman, B. W., Joseph, J. S., Saikatendu, K. S., Serrano, P., Chatterjee, A., Johnson, M. A., Liao, L., Klaus, J. P., Yates, J. R., Wüthrich, K., et al. (2008) · Journal of Virology · doi:10.1128/jvi.02631-07 · Cited by 192
“remaining after filtering were searched with the SEQUEST algorithm (12)”
MethodSelf-citationFaster SEQUEST Searching for Peptide Identification from Tandem Mass Spectra
Diament, B. J., & Noble, W. S. (2011) · Journal of Proteome Research · doi:10.1021/pr101196n · Cited by 192
Estrogen receptor α is a putative substrate for the BRCA1 ubiquitin ligase
Eakin, C. M., MacCoss, M. J., Finney, G. L., & Klevit, R. E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610887104 · Cited by 192
Muth, T., Behne, A., Heyer, R., Kohrs, F., Benndorf, D., Hoffmann, M., Lehtevä, M., Reichl, U., Martens, L., & Rapp, E. (2015) · Journal of Proteome Research · doi:10.1021/pr501246w · Cited by 192
Nie, L., Wu, G., & Zhang, W. (2006) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2005.11.055 · Cited by 191
Shotgun collision‐induced dissociation of peptides using a time of flight mass analyzer
Purvine, S., Eppel*, J., Yi, E. C., & Goodlett, D. R. (2003) · PROTEOMICS · doi:10.1002/pmic.200300362 · Cited by 191
Liu, Y., Warfield, L., Zhang, C., Luo, J., Allen, J., Lang, W. H., Ranish, J., Shokat, K. M., & Hahn, S. (2009) · Molecular and Cellular Biology · doi:10.1128/mcb.00609-09 · Cited by 191
“yeast protein database using the SEQUEST software program (15).”
MethodRapid and Accurate Peptide Identification from Tandem Mass Spectra
Park, C. Y., Klammer, A. A., Käll, L., MacCoss, M. J., & Noble, W. S. (2008) · Journal of Proteome Research · doi:10.1021/pr800127y · Cited by 191
Essential metabolism for a minimal cell
Breuer, M., Earnest, E. E., Merryman, C., Wise, K. S., Sun, L., Lynott, M. R., Hutchison, C. A., Smith, H. O., Lapek, J. D., Gonzalez, D. J., et al. (2019) · eLife · doi:10.7554/elife.36842 · Cited by 190
“The built-in version of SequestHT [147] was utilized to assign identities to MS2 spectra searching1419 against the JCVI-syn3A database downloaded from NCBI.”
MethodComprehensive Overview of Bottom-Up Proteomics Using Mass Spectrometry
Jiang, Y., Rex, D. A. B., Schuster, D., Neely, B. A., Rosano, G. L., Volkmar, N., Momenzadeh, A., Peters-Clarke, T. M., Egbert, S. B., Kreimer, S., et al. (2024) · ACS Measurement Science Au · doi:10.1021/acsmeasuresciau.3c00068 · Cited by 190
Vrana, J. A., Theis, J. D., Dasari, S., Mereuta, O. M., Dispenzieri, A., Zeldenrust, S. R., Gertz, M. A., Kurtin, P. J., Grogg, K. L., & Dogan, A. (2014) · Haematologica · doi:10.3324/haematol.2013.102764 · Cited by 190
Review on proteomics for food authentication
Ortea, I., O'Connor, G., & Maquet, A. (2016) · Journal of Proteomics · doi:10.1016/j.jprot.2016.06.033 · Cited by 190
Processing strategies and software solutions for data‐independent acquisition in mass spectrometry
Bilbao, A., Varesio, E., Luban, J., Strambio‐De‐Castillia, C., Hopfgartner, G., Müller, M., & Lisacek, F. (2015) · PROTEOMICS · doi:10.1002/pmic.201400323 · Cited by 190
Schmidt, M., Geßner, G., Luff, M., Heiland, I., Wagner, V., Kaminski, M., Geimer, S., Eitzinger, N., Reißenweber, T., Voytsekh, O., et al. (2006) · The Plant Cell · doi:10.1105/tpc.106.041749 · Cited by 190
“Scores for the cross-correlation factor Xcorr (Eng et al., 1994) were set to the following limits: Xcorr > 1.5 if the charge of the peptide is 1; Xcorr > 2 if the charge of the peptide is 2; Xcorr > 2.5 if the charge of the peptide is 3.”
BackgroundMethodInfluentialGene Expression Analyzed by High-resolution State Array Analysis and Quantitative Proteomics
MacKay, V. L., Li, X., Flory, M. R., Turcott, E., Law, G. L., Serikawa, K. A., Xu, X. L., Lee, H., Goodlett, D. R., Aebersold, R., et al. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m300129-mcp200 · Cited by 190
“Tandem MS data were analyzed by Sequest software to determine protein identity and relative quantitation (25).”
MethodDynamic Spectrum Quality Assessment and Iterative Computational Analysis of Shotgun Proteomic Data
Nesvizhskii, A. I., Roos, F. F., Grossmann, J., Vogelzang, M., Eddes, J. S., Gruissem, W., Baginsky, S., & Aebersold, R. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m500319-mcp200 · Cited by 190
Jedrychowski, M. P., Huttlin, E. L., Haas, W., Sowa, M. E., Rad, R., & Gygi, S. P. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m111.009910 · Cited by 189
“Although search algorithms such as Sequest and MASCOT are able to identify peptide sequences with high confidence, they often struggle to distinguish among isomeric forms of peptides that differ only in the localization of post-translational modifications.”
MethodInfluentialHettich, R. L., Pan, C., Chourey, K., & Giannone, R. J. (2013) · Analytical Chemistry · doi:10.1021/ac303053e · Cited by 189
Direct Cellular Lysis/Protein Extraction Protocol for Soil Metaproteomics
Chourey, K., Jansson, J., VerBerkmoes, N., Shah, M., Chavarria, K. L., Tom, L. M., Brodie, E. L., & Hettich, R. L. (2010) · Journal of Proteome Research · doi:10.1021/pr100787q · Cited by 189
Phosphoproteomic Analysis of Human Embryonic Stem Cells
Brill, L. M., Xiong, W., Lee, K.-B., Ficarro, S. B., Crain, A., Xu, Y., Terskikh, A., Snyder, E. Y., & Ding, S. (2009) · Cell Stem Cell · doi:10.1016/j.stem.2009.06.002 · Cited by 189
“Peptides were separated by SCX, phosphopeptides enriched by desalt-IMAC (Brill et al., 2004; Ficarro et al., 2005), separated by nanoflow HPLC, and analyzed by ESI-MS/MS. MS/MS spectra were matched to amino acid sequences using SEQUEST (Eng et al., 1994).”
MethodInfluentialHajduch, M., Casteel, J. E., Hurrelmeyer, K. E., Song, Z., Agrawal, G. K., & Thelen, J. J. (2006) · Plant Physiology · doi:10.1104/pp.105.075390 · Cited by 189
VIPER: an advanced software package to support high-throughput LC-MS peptide identification
Monroe, M. E., Tolić, N., Jaitly, N., Shaw, J. L., Adkins, J. N., & Smith, R. D. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm281 · Cited by 189
“Availability: VIPER may be downloaded free of charge at http:// ncrr.pnl.gov/software/ Contact: rds@pnl.gov or proteomics@pnl.gov Supplementary information: Supplementary data are available at Bioinformatics online.”
BackgroundTakahashi, N., Cho, P., Selfors, L. M., Kuiken, H. J., Kaul, R., Fujiwara, T., Harris, I. S., Zhang, T., Gygi, S. P., & Brugge, J. S. (2020) · Molecular Cell · doi:10.1016/j.molcel.2020.10.010 · Cited by 189
“(iii) Data analysis: Mass spectra were processed using a Sequest-based pipeline (Eng et al., 1994; Huttlin et al., 2010).”
MethodMass spectrometry in protein studies from genome to function
Roepstorff, P. (1997) · Current Opinion in Biotechnology · doi:10.1016/s0958-1669(97)80151-6 · Cited by 189
Savitski, M. M., Nielsen, M. L., & Zubarev, R. A. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500034-mcp200 · Cited by 188
“The main MS tool in PTM detection is tandem mass spectrometry combined with a database search engine, such as Sequest (5) or Mascot (6).”
MethodA Role for Cathepsin L and Cathepsin S in Peptide Generation for MHC Class II Presentation
Hsieh, C.-S., deRoos, P., Honey, K., Beers, C., & Rudensky, A. Y. (2002) · The Journal of Immunology · doi:10.4049/jimmunol.168.6.2618 · Cited by 188
“The acquired mass spectral data were analyzed using Thermo Finnigan ICIS 8.3 software and by searching National Center for Biotechnology Information databases using SEQUEST (28).”
MethodInfluentialShort Fimbriae of Porphyromonas gingivalis and Their Role in Coadhesion with Streptococcus gordonii
Park, Y., Simionato, M. R., Sekiya, K., Murakami, Y., James, D., Chen, W., Hackett, M., Yoshimura, F., Demuth, D. R., & Lamont, R. J. (2005) · Infection and Immunity · doi:10.1128/iai.73.7.3983-3989.2005 · Cited by 188
“All high-scoring SEQUEST hits (6, 44) against the P.”
BackgroundIkezu, T., Ueda, H., Trapp, B. D., Nishiyama, K., Sha, J. F., Volonte, D., Galbiati, F., Byrd, A. L., Bassell, G., Serizawa, H., et al. (1998) · Brain Research · doi:10.1016/s0006-8993(98)00498-3 · Cited by 188
Protein indentification using mass spectrometric information
Fenyö, D., Qin, J., & Chait, B. T. (1998) · ELECTROPHORESIS · doi:10.1002/elps.1150190615 · Cited by 188
Ordureau, A., Paulo, J. A., Zhang, W., Ahfeldt, T., Zhang, J., Cohn, E. F., Hou, Z., Heo, J.-M., Rubin, L. L., Sidhu, S. S., et al. (2018) · Molecular Cell · doi:10.1016/j.molcel.2018.03.012 · Cited by 188
Multidimensional Separations for Protein/Peptide Analysis in the Post-Genomic Era
Liu, H., Lin, D., & Yates, J. R. (2002) · BioTechniques · doi:10.2144/02324pt01 · Cited by 188
Self-citationElectrospray and tandem mass spectrometry in biochemistry
GRIFFITHS, W. J., JONSSON, A. P., LIU, S., RAI, D. K., & WANG, Y. (2001) · Biochemical Journal · doi:10.1042/bj3550545 · Cited by 187
A Face in the Crowd: Recognizing Peptides Through Database Search
Eng, J. K., Searle, B. C., Clauser, K. R., & Tabb, D. L. (2011) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r111.009522 · Cited by 187
“Eng et al. described the SEQUEST al-gorithm to match MS/MS spectra to peptides drawn from protein sequence databases (5).”
BackgroundSelf-citationMehdi, S., Derkacheva, M., Ramström, M., Kralemann, L., Bergquist, J., & Hennig, L. (2016) · The Plant Cell · doi:10.1105/tpc.15.00763 · Cited by 187
“IP1-IP2-IP3-IP4 Sequest Score IP1-IP2-IP3-IP4 AT4G38130 HDA19 19-7-15-5 52-15.8-54.3-12.8 213-181-190-46 AT5G58230 MSI1 5-3-5-4 22.6-7.8-17.2-14.4 16.7-18.3-22.7-34 AT3G01320 SNL1 5-4-3-2 5.4-4.1-4.3-3 23.6-20.9-27.9-21 AT5G15020 SNL2 20-10-14-8 19.6-9.3-14-8.6 97.8-54.7-121-67 AT1G24190 SNL3 15-5-6-2 13.8-5.3-4.9-1.9…”
MethodInfluentialCombining Results of Multiple Search Engines in Proteomics
Shteynberg, D., Nesvizhskii, A. I., Moritz, R. L., & Deutsch, E. W. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r113.027797 · Cited by 187
“Tandem (5), Mascot (6), SEQUEST (7), MyriMatch (8), MS-GFDB (9), and OMSSA (10), which attempt to match acquired spectra with theoretical spectra generated from possible peptide sequences contained in a protein sequence list; spectral library search engines such as SpectraST (11), X!”
BackgroundGoltsman, D. S. A., Denef, V. J., Singer, S. W., VerBerkmoes, N. C., Lefsrud, M., Mueller, R. S., Dick, G. J., Sun, C. L., Wheeler, K. E., Zemla, A., et al. (2009) · Applied and Environmental Microbiology · doi:10.1128/aem.02943-08 · Cited by 187
“were searched using the SEQUEST algorithm (28) in a global database created”
MethodWilmes, P., Andersson, A. F., Lefsrud, M. G., Wexler, M., Shah, M., Zhang, B., Hettich, R. L., Bond, P. L., VerBerkmoes, N. C., & Banfield, J. F. (2008) · The ISME Journal · doi:10.1038/ismej.2008.38 · Cited by 187
“phosphatis have shown ability to denitrify (Zeng et al., 2003). Although the majority of enzymes involved in denitrification were encoded by the composite A. phosphatis genome, Garcı́a Martı́n et al. (2006) lamented the absence of a respiratory nitrate reductase (NAR) due to the lack of quinol reductase subunit (napC)…”
BackgroundMethodPhosphoPep—a phosphoproteome resource for systems biology research in Drosophila Kc167 cells
Bodenmiller, B., Malmstrom, J., Gerrits, B., Campbell, D., Lam, H., Schmidt, A., Rinner, O., Mueller, L. N., Shannon, P. T., Pedrioli, P. G., et al. (2007) · Molecular Systems Biology · doi:10.1038/msb4100182 · Cited by 187
“The fragment ion spectra obtained in this study were assigned to (phospho)peptide sequences using the sequence database search tool Sequest (Eng et al , 1994) and were investigated for two forms of errors in the data set: first, the miss-assignment of the fragment ion spectrum to a peptide sequence…”
BackgroundMethodResultInfluentialAn approach to proteomic analysis of human tumors
Emmert‐Buck, M. R., Gillespie, J. W., Paweletz, C. P., Ornstein, D. K., Basrur, V., Appella, E., Wang, Q. H., Huang, J. L., Hu, N., Taylor, P. R., et al. (2000) · Molecular Carcinogenesis · doi:10.1002/(sici)1098-2744(200003)27:3<158::aid-mc2>3.0.co;2-2 · Cited by 187
Figeys, D., Ducret, A., Yates, J. R., & Aebersold, R. (1996) · Nature Biotechnology · doi:10.1038/nbt1196-1579 · Cited by 187
Self-citationDenef, V. J., Kalnejais, L. H., Mueller, R. S., Wilmes, P., Baker, B. J., Thomas, B. C., VerBerkmoes, N. C., Hettich, R. L., & Banfield, J. F. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0907041107 · Cited by 186
“Peptide identification relied on spectral assignments using the Sequest algorithm (47) using the search database described in detail in (24).”
Method
Metadata
- Authors
- Eng, J. K., McCormack, A. L., & Yates, J. R.
- Affiliations
- University of Washington (US)
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 1994-11-01
- Volume
- 5
- Issue
- 11
- Pages
- 976-989
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2026465178
- Cited by
- 6,484
- References
- 38
- Citations by year
- 2026: 100 · 2025: 172 · 2024: 190 · 2023: 207 · 2022: 196 · 2021: 237 · 2020: 256 · 2019: 251 · 2018: 216 · 2017: 237 · 2016: 231 · 2015: 268 · 2014: 263 · 2013: 310 · 2012: 326
- FWCI
- 15.88
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of the American Society for Mass Spectrometry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation (8809710)
- University of Washington
- University of Oregon
- National Research Foundation
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Keywords
- tandem mass spectrometry, peptide identification, protein databases, cross correlation function, low-energy collision-induced dissociation, Escherichia coli, Saccharomyces cerevisiae, enzymatic protein digestion
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.