The DOI matches its Crossref record; 206 of the 206 references it cites were found in a registry or an index.
Ambulatory cardiac bio-signals: From mirage to clinical reality through a decade of progress
Abstract
Background Health monitoring is shifting towards continuous, ambulatory and clinically comparable wearable devices. Telemedicine and remote diagnosis could harness the capability of mobile cardiac health information, as the technology on bio-physical signal monitoring has improved significantly.Objectives The purpose of this review article is (1) to systematically assess the viability of ambulatory electrocardiography (ECG), (2) to provide a systems level understanding of a broad spectrum of wearable heart signal monitoring approaches and (3) to identify areas of improvement in the existing technology needed to attain clinical grade diagnosis.Results Based on the included literature, we have identified (1) that the developments in ECG monitoring through wearable devices are reaching feasibility, and are capable of delivering diagnostic and prognostic information, (2) that reliable sensing is the major bottleneck in the entire process of ambulatory monitoring, (3) that there is a strong need for artificial intelligence and machine learning techniques to parse and infer the biosignals and (4) that aspects of wearer comfort has largely been ignored in the prevailing developments, which can become a key factor for consumer acceptance.Conclusions Cardiac health information is crucial for diagnosis and prevention of several disease onsets. Mobile and continuous monitoring can aid avoiding risks involved with acute symptoms. The health information obtained through continuous monitoring can serve as the BigData of heart signals, and can facilitate new treatment methods and devise effective health policies.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recently, in addition to Holter monitoring, which has been traditionally used, the use of patch-type, watch-type, ring-type, and clothing-type monitoring systems have been approved by the FDA.138”
From Artificial intelligence for detection of cardiovascular-related diseases from wearable devices: A systematic review and meta-analysis (2022) · cites this paper as [138]
Citations
Cites
Heart Disease and Stroke Statistics—2017 Update: A Report From the American Heart Association
Benjamin, E. J., Blaha, M. J., Chiuve, S. E., Cushman, M., Das, S. R., Deo, R., de Ferranti, S. D., Floyd, J., Fornage, M., Gillespie, C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000485 · Cited by 12,591
A review of wearable sensors and systems with application in rehabilitation
Patel, S., Park, H., Bonato, P., Chan, L., & Rodgers, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-21 · Cited by 2,396
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Smart wearable systems: Current status and future challenges
Chan, M., Estève, D., Fourniols, J.-Y., Escriba, C., & Campo, E. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.09.003 · Cited by 953
Electronic Health Records: Then, Now, and in the Future
Evans, R. S. (2016) · Yearbook of Medical Informatics · doi:10.15265/iys-2016-s006 · Cited by 816
A direct comparison of wet, dry and insulating bioelectric recording electrodes
Searle, A., & Kirkup, L. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/307 · Cited by 736
Heat Generation and Transport in Nanometer-Scale Transistors
Pop, E., Sinha, S., & Goodson, K. E. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.879794 · Cited by 712
(2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2417514 · Cited by 712
Middleton, B., Bloomrosen, M., Dente, M. A., Hashmat, B., Koppel, R., Overhage, J. M., Payne, T. H., Rosenbloom, S. T., Weaver, C., & Zhang, J. (2013) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001458 · Cited by 618
Holter, N. J. (1961) · Science · doi:10.1126/science.134.3486.1214 · Cited by 566
Melgani, F., & Bazi, Y. (2008) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2008.923147 · Cited by 526
Barrett, P. M., Komatireddy, R., Haaser, S., Topol, S., Sheard, J., Encinas, J., Fought, A. J., & Topol, E. J. (2014) · The American Journal of Medicine · doi:10.1016/j.amjmed.2013.10.003 · Cited by 498
An IoT-cloud Based Wearable ECG Monitoring System for Smart Healthcare
Yang, Z., Zhou, Q., Lei, L., Zheng, K., & Xiang, W. (2016) · Journal of Medical Systems · doi:10.1007/s10916-016-0644-9 · Cited by 490
Kim, T., Park, J., Sohn, J., Cho, D., & Jeon, S. (2016) · ACS Nano · doi:10.1021/acsnano.6b01355 · Cited by 474
(2014) · IEEE Pulse · doi:10.1109/mpul.2014.2316040 · Cited by 456
Smart wearable body sensors for patient self-assessment and monitoring
Appelboom, G., Camacho, E., Abraham, M. E., Bruce, S. S., Dumont, E. L., Zacharia, B. E., D’Amico, R. S., Slomian, J., Reginster, J., Bruyère, O., et al. (2014) · Archives of Public Health · doi:10.1186/2049-3258-72-28 · Cited by 445
CNT/PDMS Composite Flexible Dry Electrodesfor Long-Term ECG Monitoring
Jung, H.-C., Moon, J.-H., Baek, D.-H., Lee, J.-H., Choi, Y.-Y., Hong, J.-S., & Lee, S.-H. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2190288 · Cited by 434
2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
(2005) · doi:10.1109/embc9043.2006 · Cited by 423
Mercer, K., Giangregorio, L., Schneider, E., Chilana, P., Li, M., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4225 · Cited by 419
Security Issues in Healthcare Applications Using Wireless Medical Sensor Networks: A Survey
Kumar, P., & Lee, H. J. (2011) · Sensors · doi:10.3390/s120100055 · Cited by 414
Powering pacemakers from heartbeat vibrations using linear and nonlinear energy harvesters
Amin Karami, M., & Inman, D. J. (2012) · Applied Physics Letters · doi:10.1063/1.3679102 · Cited by 390
Chen, F., Chandrakasan, A. P., & Stojanovic, V. M. (2012) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2011.2179451 · Cited by 383
Flexible polymeric dry electrodes for the long-term monitoring of ECG
Baek, J.-Y., An, J.-H., Choi, J.-M., Park, K.-S., & Lee, S. (2007) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2007.11.019 · Cited by 339
Recent Advances in Wearable Sensors for Health Monitoring
Rodgers, M. M., Pai, V. M., & Conroy, R. S. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2357257 · Cited by 325
Energy harvesting for the implantable biomedical devices: issues and challenges
Hannan, M. A., Mutashar, S., Samad, S. A., & Hussain, A. (2014) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-13-79 · Cited by 322
Lake, D. E., & Moorman, J. R. (2010) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00561.2010 · Cited by 318
Steinberg, J. S., Varma, N., Cygankiewicz, I., Aziz, P., Balsam, P., Baranchuk, A., Cantillon, D. J., Dilaveris, P., Dubner, S. J., El-Sherif, N., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.038 · Cited by 303
Dry electrodes for electrocardiography
Meziane, N., Webster, J. G., Attari, M., & Nimunkar, A. J. (2013) · Physiological Measurement · doi:10.1088/0967-3334/34/9/r47 · Cited by 289
A comprehensive survey of wearable and wireless ECG monitoring systems for older adults
Baig, M. M., Gholamhosseini, H., & Connolly, M. J. (2013) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-1021-6 · Cited by 284
A 3D printed dry electrode for ECG/EEG recording
Salvo, P., Raedt, R., Carrette, E., Schaubroeck, D., Vanfleteren, J., & Cardon, L. (2011) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2011.12.017 · Cited by 265
Diagnostic utility of a novel leadless arrhythmia monitoring device.
Turakhia, M. P., Hoang, D. D., Zimetbaum, P., Miller, J. D., Froelicher, V. F., Kumar, U. N., Xu, X., Yang, F., & Heidenreich, P. A. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.04.017 · Cited by 258
Novel dry electrodes for ECG monitoring
Gruetzmann, A., Hansen, S., & Müller, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/11/005 · Cited by 248
Graphene-clad textile electrodes for electrocardiogram monitoring
Yapici, M. K., Alkhidir, T., Samad, Y. A., & Liao, K. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.07.111 · Cited by 241
Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring
Lee, S. P., Ha, G., Wright, D. E., Ma, Y., Sen-Gupta, E., Haubrich, N. R., Branche, P. C., Li, W., Huppert, G. L., Johnson, M. D., et al. (2018) · npj Digital Medicine · doi:10.1038/s41746-017-0009-x · Cited by 230
Medical informatics: Past, present, future☆☆☆
Haux, R. (2010) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2010.06.003 · Cited by 226
Fabric-Based Wearable Dry Electrodes for Body Surface Biopotential Recording
Yokus, M. A., & Jur, J. S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2462312 · Cited by 214
A brief review: history to understand fundamentals of electrocardiography
AlGhatrif, M., & Lindsay, J. M. (2012) · Journal of Community Hospital Internal Medicine Perspectives · doi:10.3402/jchimp.v2i1.14383 · Cited by 211
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
Fully Textile, PEDOT:PSS Based Electrodes for Wearable ECG Monitoring Systems
Pani, D., Dessì, A., Saenz-Cogollo, J. F., Barabino, G., Fraboni, B., & Bonfiglio, A. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2465936 · Cited by 202
Rienzo, M. D., Rizzo, F., Parati, G., Brambilla, G., Ferratini, M., & Castiglioni, P. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616161 · Cited by 200
Direct patterning of organic conductors on knitted textiles for long-term electrocardiography
Takamatsu, S., Lonjaret, T., Crisp, D. N., Badier, J., Malliaras, G. G., & Ismailova, E. (2015) · Scientific Reports · doi:10.1038/srep15003 · Cited by 195
Wireless Non-contact EEG/ECG Electrodes for Body Sensor Networks
Yu, M., & Cauwenberghs, G. (2010) · doi:10.1109/bsn.2010.52 · Cited by 183
Lee, S. M., Byeon, H. J., Lee, J. H., Baek, D. H., Lee, K. H., Hong, J. S., & Lee, S.-H. (2014) · Scientific Reports · doi:10.1038/srep06074 · Cited by 181
A novel approach for classification of ECG arrhythmias: Type-2 fuzzy clustering neural network
Ceylan, R., Özbay, Y., & Karlık, B. (2008) · Expert Systems with Applications · doi:10.1016/j.eswa.2008.08.028 · Cited by 178
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P. E., Stone, P. H., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P. F., BREITHARDT, G. E., et al. (2012) · EP Europace · doi:10.1093/europace/eur303 · Cited by 178
An Adaptive Kalman Filter for ECG Signal Enhancement
Vullings, R., de Vries, B., & Bergmans, J. W. M. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2099229 · Cited by 174
Nanomaterial-Enabled Dry Electrodes for Electrophysiological Sensing: A Review
Yao, S., & Zhu, Y. (2016) · JOM · doi:10.1007/s11837-016-1818-0 · Cited by 172
Fetal electrocardiography: feasibility of long‐term fetal heart rate recordings
Graatsma, E. M., Jacod, B. C., van Egmond, L., Mulder, E. J. H., & Visser, G. H. A. (2008) · BJOG An International Journal of Obstetrics & Gynaecology · doi:10.1111/j.1471-0528.2008.01951.x · Cited by 166
Energy scavenging sources for biomedical sensors
Romero, E., Warrington, R. O., & Neuman, M. R. (2009) · Physiological Measurement · doi:10.1088/0967-3334/30/9/r01 · Cited by 165
High-Performance Personalized Heartbeat Classification Model for Long-Term ECG Signal
Li, P., Wang, Y., He, J.-C., et al. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2539421 · Cited by 160
Lee, J., McManus, D. D., Merchant, S., & Chon, K. H. (2011) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2011.2175729 · Cited by 159
Biomedical data privacy: problems, perspectives, and recent advances
Malin, B., Emam, K. E., & O’Keefe, C. M. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-001509 · Cited by 159
A survey on wearable biosensor systems for health monitoring
Pantelopoulos, A., & Bourbakis, N. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4650309 · Cited by 147
Marozas, V., Petrėnas, A., Daukantas, S., & Lukoševičius, A. (2011) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.12.004 · Cited by 141
Flexible Graphene Electrodes for Prolonged Dynamic ECG Monitoring
Lou, C., Li, R., Li, Z., Liang, T., Wei, Z., Run, M., Yan, X., & Liu, X. (2016) · Sensors · doi:10.3390/s16111833 · Cited by 140
Long-term patient acceptance of and satisfaction with implanted device remote monitoring
Ricci, R. P., Morichelli, L., Quarta, L., Sassi, A. D. G., Porfili, A., Laudadio, M. T., Gargaro, A., & Santini, M. (2010) · EP Europace · doi:10.1093/europace/euq046 · Cited by 138
Embroidered Electrode with Silver/Titanium Coating for Long-Term ECG Monitoring
Weder, M., Hegemann, D., Amberg, M., et al. (2015) · Sensors · doi:10.3390/s150101750 · Cited by 130
Paul, G., Torah, R. N., Beeby, S., & Tudor, J. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.11.026 · Cited by 127
DSP-based arrhythmia classification using wavelet transform and probabilistic neural network
Gnecchi, J. A. G., Morfin-Magaña, R., Espinoza, D. L., Téllez-Anguiano, A. D. C., Reyes‐Archundia, E., Méndez-Pátiño, A., & Castañeda-Miranda, R. (2016) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.10.005 · Cited by 125
ECG patch monitors for assessment of cardiac rhythm abnormalities
Lobodzinski, S. S. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.08.006 · Cited by 119
ECG Arrhythmia Classification with Support Vector Machines and Genetic Algorithm
Nasiri, J. A., Naghibzadeh, M., Yazdi, H. S., et al. (2009) · UKSim European Symposium on Computer Modeling and Simulation (EMS) · doi:10.1109/ems.2009.39 · Cited by 119
First human trials of a dry electrophysiology sensor using a carbon nanotube array interface
Ruffini, G., Dunne, S., Fuentemilla, L., Grau, C., Farrés, E., Marco‐Pallarés, J., Watts, P. C. P., & Silva, S. R. P. (2008) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2008.03.007 · Cited by 113
A microfabricated electrode with hollow microneedles for ECG measurement
Yu, L., Tay, F. E. H., Guo, D., Xu, L., & Yap, K. L. (2009) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2009.01.020 · Cited by 113
Flexible Capacitive Electrodes for Minimizing Motion Artifacts in Ambulatory Electrocardiograms
Lee, J. S., Heo, J., Lee, W., et al. (2014) · Sensors · doi:10.3390/s140814732 · Cited by 111
Joshi, A. K., Kowey, P. R., Prystowsky, E. N., Benditt, D. G., Cannom, D. S., Pratt, C. M., McNamara, A., & Sangrigoli, R. M. (2005) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2004.12.015 · Cited by 110
Belden, J. L., Grayson, R. L., & Barnes, J. (2009) · MOspace Institutional Repository (University of Missouri) · Cited by 107
Fabric-Based Active Electrode Design and Fabrication for Health Monitoring Clothing
Merritt, C. R., Nagle, H. T., & Grant, E. (2009) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2009.2012408 · Cited by 99
Ziegler, P., Rogers, J., Ferreira, S. W., Nichols, A. J., Richards, M., Koehler, J. L., & Sarkar, S. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.06.039 · Cited by 98
A flexible hydrophilic-modified graphene microprobe for neural and cardiac recording
Chen, C., Lin, C., Hsu, W.-L., Chang, Y., Yeh, S., Li, L., & Yao, D. (2013) · Nanomedicine Nanotechnology Biology and Medicine · doi:10.1016/j.nano.2012.12.004 · Cited by 96
Miniaturized Reveal LINQ insertable cardiac monitoring system: First-in-human experience
Pürerfellner, H., Sanders, P., Pokushalov, E. A., Bacco, M. D., Bergemann, T. L., & Dekker, L. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.02.030 · Cited by 96
Lymberis, A. (2003) · doi:10.1109/itab.2003.1222530 · Cited by 93
A wearable mobihealth care system supporting real-time diagnosis and alarm
Zheng, J., Zhang, Z. B., Wu, T., et al. (2007) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0221-y · Cited by 92
Graphene-Enabled Electrodes for Electrocardiogram Monitoring
Celik, N., Manivannan, N., Strudwick, A. J., & Balachandran, W. (2016) · Nanomaterials · doi:10.3390/nano6090156 · Cited by 87
Low-Power Analog Integrated Circuits for Wireless ECG Acquisition Systems
Tsai, T., Hong, J.-H., Wang, L.-H., & Lee, S.-Y. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188412 · Cited by 82
Artifacts in portable electrocardiographic monitoring
Krasnow, A. Z., & Bloomfield, D. K. (1976) · American Heart Journal · doi:10.1016/s0002-8703(76)80220-7 · Cited by 81
Chen, K., Ren, L., Chen, Z., et al. (2016) · Sensors · doi:10.3390/s16091533 · Cited by 75
Wearable Wireless Cardiovascular Monitoring Using Textile-Based Nanosensor and Nanomaterial Systems
Shyamkumar, P., Rai, P., Oh, S., Ramasamy, M., Harbaugh, R. E., & Varadan, V. K. (2014) · Electronics · doi:10.3390/electronics3030504 · Cited by 74
Smart wearable systems for personalised health management: current R&D and future challenges
Lymberis, A. (2004) · doi:10.1109/iembs.2003.1280967 · Cited by 73
Correlation Between Electrode-Tissue Impedance and Motion Artifact in Biopotential Recordings
Buxi, D., Kim, S., Helleputte, N. V., Altini, M., Wijsman, J., Yazıcıoğlu, R. F., Penders, J., & Hoof, C. A. V. (2012) · IEEE Sensors Journal · doi:10.1109/jsen.2012.2221163 · Cited by 72
Ehmen, H., Haesner, M., Steinke, I., et al. (2011) · Applied Ergonomics · doi:10.1016/j.apergo.2011.09.003 · Cited by 70
Older adults' acceptance of a community-based telehealth wellness system
Demiris, G., Thompson, H. J., Boquet, J. R., et al. (2012) · Informatics for Health and Social Care · doi:10.3109/17538157.2011.647938 · Cited by 66
Melillo, P., Orrico, A., Scala, P., Crispino, F., & Pecchia, L. (2015) · Journal of Medical Systems · doi:10.1007/s10916-015-0294-3 · Cited by 63
Adaptive Motion Artifacts Reduction Using 3-axis Accelerometer in E-textile ECG Measurement System
Yoon, S. W., Min, S. D., Yun, Y. H., et al. (2007) · Journal of Medical Systems · doi:10.1007/s10916-007-9112-x · Cited by 63
(2016) · doi:10.1109/embc.2016.7590779 · Cited by 63
Li, C., Un, K.-F., Mak, P., Chen, Y., Muñoz‐Ferreras, J., Yang, Z., & Gómez‐García, R. (2018) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2018.2822684 · Cited by 62
Assessment of Dry Epidermal Electrodes for Long-Term Electromyography Measurements
Yamagami, M., Peters, K. M., Milovanovic, I. P., Kuang, I., Yang, Z., Lu, N., & Steele, K. M. (2018) · Sensors · doi:10.3390/s18041269 · Cited by 61
Automated Screening of Arrhythmia Using Wavelet Based Machine Learning Techniques
Martis, R. J., Krishnan, M. M. R., Chakraborty, C., Pal, S., Sarkar, D., Mandana, K. M., & Ray, A. K. (2010) · Journal of Medical Systems · doi:10.1007/s10916-010-9535-7 · Cited by 59
Smith, W., Riddell, F., Madon, M., & Gleva, M. J. (2016) · American Heart Journal · doi:10.1016/j.ahj.2016.11.006 · Cited by 59
Skin-Potential Variation Insensitive Dry Electrodes for ECG Recording
Pei, W., Zhang, H., Wang, Y., et al. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2562702 · Cited by 56
Dikeçligil, G. N., & Mujica-Parodi, L. R. (2010) · Biological Psychiatry · doi:10.1016/j.biopsych.2010.02.001 · Cited by 55
Hernández‐Madrid, A., Lewalter, T., Proclemer, A., Pison, L., Lip, G. Y. H., & Blomström‐Lundqvist, C. (2013) · EP Europace · doi:10.1093/europace/eut414 · Cited by 54
Design and Evaluation of Novel Textile Wearable Systems for the Surveillance of Vital Signals
Trindade, I. G., da Silva, J. M., Miguel, R. A. L., Pereira, M., Lucas, J. M., Oliveira, L. B., Valentim, B., Barreto, J., & Silva, M. S. (2016) · Sensors · doi:10.3390/s16101573 · Cited by 54
2013 IEEE Biomedical Circuits and Systems Conference (BioCAS)
(2013) · doi:10.1109/biocas20698.2013 · Cited by 54
de Asmundis, C., Conte, G., Sieira, J., Chierchia, G.-B., Rodriguez-Manero, M., Di Giovanni, G., Ciconte, G., Levinstein, M., Baltogiannis, G., Saitoh, Y., et al. (2014) · Europace · doi:10.1093/europace/eut411 · Cited by 52
Wearable carbon nanotubes-based polymer electrodes for ambulatory electrocardiographic measurements
Liu, B., Tang, H., Luo, Z., Zhang, W., Tu, Q., & Jin, X. (2017) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2017.08.036 · Cited by 51
Ambulation Analysis in Wearable ECG
Chaudhuri, S., Pawar, T., & Duttagupta, S. P. (2009) · Springer eBooks · doi:10.1007/978-1-4419-0724-0 · Cited by 50
The Evolution of Ambulatory ECG Monitoring
Kennedy, H. L. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.08.005 · Cited by 50
Motion artifact removal using cascade adaptive filtering for ambulatory ECG monitoring system
Kim, H., Kim, S., Helleputte, N. V., et al. (2012) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas.2012.6418472 · Cited by 49
A wavelet based technique for suppression of EMG noise and motion artifact in ambulatory ECG
Mithun, P., Pandey, P. C., Sebastian, T., et al. (2011) · doi:10.1109/iembs.2011.6091791 · Cited by 48
Clasification Of Arrhythmic ECG Data Using Machine Learning Techniques
Vishwa, A., Lal, M. K., Dixit, S., et al. (2011) · International Journal of Interactive Multimedia and Artificial Intelligence · doi:10.9781/ijimai.2011.1411 · Cited by 48
Heart Monitoring Garments Using Textile Electrodes for Healthcare Applications
Cho, H.-S., Koo, S. H., Lee, J., Cho, H., Kang, D.-H., Song, H., Lee, J., Lee, K.-H., & Lee, Y. (2009) · Journal of Medical Systems · doi:10.1007/s10916-009-9356-8 · Cited by 48
Simultaneous comparison of 1 gel with 4 dry electrode types for electrocardiography
Meziane, N., Yang, S., Shokoueinejad, M., Webster, J. G., Attari, M., & Eren, H. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/3/513 · Cited by 48
Dubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Comparing 14-day Adhesive Patch With 24-h Holter Monitoring
Cheung, C. C., Kerr, C. R., & Krahn, A. D. (2014) · Future Cardiology · doi:10.2217/fca.14.24 · Cited by 46
Biomedical Engineering Systems and Technologies
(2008) · Communications in computer and information science · doi:10.1007/978-3-540-92219-3 · Cited by 44
Flexible PDMS -based dry electrodes for electro-optic acquisition of ECG signals in wearable devices
Fernandes, M. S., Lee, K. S., Ram, R. J., Correia, J. H., & Mendes, P. M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5627799 · Cited by 44
Accurate, Automated Detection of Atrial Fibrillation in Ambulatory Recordings
Linker, D. T. (2016) · Cardiovascular Engineering and Technology · doi:10.1007/s13239-016-0256-z · Cited by 44
ECG assessment based on neural networks with pretraining
Ribas, V. J., Wojdel, A., Romero, E. E., Ramos, P. M., & Brugada, J. (2016) · Applied Soft Computing · doi:10.1016/j.asoc.2016.08.013 · Cited by 44
Anjum, M. U., Fida, A., Ahmad, I., & Iftikhar, A. (2018) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2018.05.001 · Cited by 43
Microelectronic skin electrode
Padmadinata, F. Z., Veerhoek, J. J., van Dijk, G. J. A., et al. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80257-z · Cited by 42
Research and development of smart wearable health applications: the challenge ahead.
Lymberis, A. (2004) · PubMed · Cited by 39
38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
(2015) · IEEE Pulse · doi:10.1109/mpul.2015.2470696 · Cited by 38
Ackermans, P. A. J., Solosko, T. A., Spencer, E. C., Gehman, S. E., Nammi, K., Engel, J., & Russell, J. K. (2012) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2011.10.007 · Cited by 37
Ultra-Low Power Design of Wearable Cardiac Monitoring Systems
Braojos, R., Mamaghanian, H., Dias, A., Ansaloni, G., Atienza, D., Rincon, F., & Murali, S. (2014) · ACM/IEEE Design Automation Conference (DAC) · doi:10.1145/2593069.2596691 · Cited by 37
Altini, M., Polito, S., Penders, J., Kim, H., Van Helleputte, N., Kim, S., & Yazicioglu, F. (2011) · Proceedings of the 2nd Conference on Wireless Health · doi:10.1145/2077546.2077564 · Cited by 36
Kohno, R., Abe, H., & Benditt, D. G. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.04.012 · Cited by 35
Adaptive filtering in ECG denoising: A comparative study
Romero, I., Geng, D., & Berset, T. (2012) · Computing in cardiology · Cited by 35
IEEE/ICME International Conference on Complex Medical Engineering
(2010) · doi:10.1109/cme15967.2010 · Cited by 34
Motion artifact reduction in ambulatory ECG monitoring
Romero, I., Berset, T., Buxi, D., et al. (2011) · doi:10.1145/2077546.2077558 · Cited by 33
Wearable Medical Devices Using Textile and Flexible Technologies for Ambulatory Monitoring
Dittmar, A., Meffre, R., de Oliveira, F., Géhin, C., & Delhomme, G. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616159 · Cited by 33
Micro energy harvesting for biomedical applications: A review
Mhetre, M. R., Nagdeo, N. S., & Abhyankar, H. K. (2011) · International Conference on Electronics Computer Technology · doi:10.1109/icectech.2011.5941789 · Cited by 31
Zhang, Z., Silva, I., Wu, D., Zheng, J., Wu, H., & Wang, W. (2014) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-014-1201-7 · Cited by 31
Torres, I. C., Bustamante, J., & Sierra, D. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-4086-3 · Cited by 31
Myllymaa, S., Pirinen, S., Myllymaa, K., Suvanto, M., Pakkanen, T. A., Pakkanen, T. A., & Lappalainen, R. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/12/125701 · Cited by 30
A Neural Network approach and Wavelet analysis for ECG classification
Gautam, M. K., & Giri, V. K. (2016) · IEEE International Conference on Engineering and Technology · doi:10.1109/icetech.2016.7569428 · Cited by 30
Comfortable textile-based electrode for wearable electrocardiogram
Haghdoost, F., Mottaghitalab, V., & Haghi, A. K. (2015) · Sensor Review · doi:10.1108/sr-08-2013-719 · Cited by 29
Impact of Ambulation in Wearable-ECG
Pawar, T., Anantakrishnan, N. S., Chaudhuri, S., & Duttagupta, S. P. (2008) · Annals of Biomedical Engineering · doi:10.1007/s10439-008-9526-8 · Cited by 29
Khairuddin, A. M., Azir, K. N. F. K., & Kan, P. E. (2017) · International Conference on Research and Innovation in Information Systems · doi:10.1109/icriis.2017.8002506 · Cited by 29
A Web Based Cardiovascular Disease Detection System
Alshraideh, H. A., Otoom, M., Al-Araida, A., et al. (2015) · Journal of Medical Systems · doi:10.1007/s10916-015-0290-7 · Cited by 28
Ko, B.-H., Lee, T., Choi, C., et al. (2012) · doi:10.1109/embc.2012.6346248 · Cited by 28
Simple method for adaptive filtering of motion artifacts in E-textile wearable ECG sensors
Alkhidir, T., Sluzek, A. S., & Yapici, M. K. (2015) · doi:10.1109/embc.2015.7319223 · Cited by 28
Hydra: A web-based system for cardiovascular analysis, diagnosis and treatment
Novo, J., Ameijeiras, Á. H., Ortega, M., Barreira, N., Penedo, M. G., López, J. E., & Calvo, C. (2016) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2016.10.019 · Cited by 28
Performance of the New BioMonitor 2‐AF Insertable Cardiac Monitoring System: Can Better be Worse?
Lacour, P., Dang, P. L., Huemer, M., Parwani, A. S., Attanasio, P., Pieske, B. M., Boldt, L., Haverkamp, W., & Blaschke, F. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13059 · Cited by 28
QRS complex detection in ECG signal for wearable devices
Arefin, M., Tavakolian, K., & Fazel-Rezai, R. (2015) · doi:10.1109/embc.2015.7319744 · Cited by 27
Development of a Technique for Cancelling Motion Artifact in Ambulatory ECG Monitoring System
Jeong, D., & Kim, S.-J. (2008) · doi:10.1109/iccit.2008.315 · Cited by 26
Low power wireless acquisition module for wearable health monitoring systems
Figueiredo, C. P., Becher, K., Hoffmann, K. ‐., & Mendes, P. M. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626161 · Cited by 25
ECG Parameter Extraction Algorithm using (DWTAE) Algorithm
Elbuni, A., Kanoun, S. H., Elbuni, M. S., et al. (2009) · International Conference on Computer Technology and Development · doi:10.1109/icctd.2009.103 · Cited by 25
Park, K., Im, S. I., Park, S., et al. (2017) · International Journal of Cardiology · doi:10.1016/j.ijcard.2017.02.007 · Cited by 25
Welté, N., Strik, M., Eschalier, R., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.03.023 · Cited by 25
Ottenbacher, J., Kirst, M., Jatobá, L., et al. (2007) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-74471-9_102 · Cited by 24
ECG feature extraction in temporal domain and detection of various heart conditions
Khan, T. T., Sultana, N., Reza, R. B., et al. (2015) · International Conference on Electrical Engineering and Information Communication Technology · doi:10.1109/iceeict.2015.7307507 · Cited by 24
2008 3rd International Conference on Sensing Technology
(2008) · doi:10.1109/icst13966.2008 · Cited by 24
Burkowitz, J., Merzenich, C., Grassme, K. S., & Brüggenjürgen, B. (2016) · European Journal of Preventive Cardiology · doi:10.1177/2047487316632628 · Cited by 22
Derkac, W. M., Finkelmeier, J. R., Horgan, D. J., & Hutchinson, M. D. (2017) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.13342 · Cited by 22
Estimation of patient compliance in application of adherent mobile cardiac telemetry device
Engel, J. M., Chakravarthy, N., Katra, R., Mazar, S. T., Libbus, I., & Chavan, A. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090448 · Cited by 21
(2008) · PubMed · Cited by 21
Ultra Low Power programmable biomedical SoC for on-body ECG and EEG processing
Busze, B., de Groot, H., Santana, O., et al. (2010) · IEEE Asian Solid-State Circuits Conference (A-SSCC) · doi:10.1109/asscc.2010.5716625 · Cited by 20
Human Factors Affecting the Patient’s Acceptance of Wireless Biomedical Sensors
Fensli, R. W., & Boisen, E. (2008) · Communications in computer and information science · doi:10.1007/978-3-540-92219-3_30 · Cited by 19
Reduction of Motion Artifacts In Electrocardiogram Monitoring Using an Optical Sensor
Liu, Y., & PECHT, M. G. (2011) · Biomedical Instrumentation & Technology · doi:10.2345/0899-8205-45.2.155 · Cited by 19
New directions for ambulatory monitoring following 2017 HRS-ISHNE expert consensus
Locati, E. H. (2017) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2017.08.009 · Cited by 19
2011 International Conference on Body Sensor Networks
(2011) · doi:10.1109/bsn18979.2011 · Cited by 19
A textile-based wearable system for the prolonged assessment of cardiac mechanics in daily life
Rienzo, M. D., Vaini, E., Castiglioni, P., Lombardi, P., Meriggi, P., & Rizzo, F. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6945213 · Cited by 18
The Spectrum of Ambulatory Electrocardiographic Monitoring
Mond, H. G. (2017) · Heart Lung and Circulation · doi:10.1016/j.hlc.2017.02.034 · Cited by 18
A Hybrid Low Power Biopatch for Body Surface Potential Measurement
Yang, G., Chen, J., Xie, L., Mao, J., Tenhunen, H., & Zheng, L. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2013.2252017 · Cited by 17
Rienzo, M. D., Rizzo, F., Meriggi, P., et al. (2009) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2009.934627 · Cited by 17
The HEART Pathway and Hospital Cost Savings
Yau, A., Nguyendo, L. T., Lockett, L., et al. (2017) · Critical Pathways in Cardiology A Journal of Evidence-Based Medicine · doi:10.1097/hpc.0000000000000124 · Cited by 17
Vinck, I., Laet, C. E. D. H. D., Stroobandt, S., et al. (2012) · EP Europace · doi:10.1093/europace/eus004 · Cited by 16
Romero, I. (2013) · Cardiology in Review · doi:10.1097/crd.0b013e31828a8294 · Cited by 16
Berset, T., Geng, D., & Romero, I. (2012) · doi:10.1109/embc.2012.6347482 · Cited by 15
Wearable mobile ear-based ECG monitoring device using graphene-coated sensors
Celik, N., Balachandran, W., Manivannan, N., et al. (2017) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2017.8233911 · Cited by 15
Jain, S., & Bhaumik, B. (2016) · Healthcare Technology Letters · doi:10.1049/htl.2015.0030 · Cited by 14
A printed, dry electrode Frank configuration vest for ambulatory vectorcardiographic monitoring
Paul, G., Torah, R. N., Beeby, S., et al. (2016) · Smart Materials and Structures · doi:10.1088/1361-665x/aa5436 · Cited by 14
Proceedings of the 2nd Conference on Wireless Health
Jacobs, I. M., Soon‐Shiong, P., Topol, E. J., & Toumazou, C. (2011) · doi:10.1145/2077546 · Cited by 14
Naccarelli, G. V. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2006.00737.x · Cited by 13
Akiyama, H., Nukui, S., Araga, T., Hoshino, M., Tanaka, K., Kashima, S., Sasaki, R., Uchino, K., & Hasegawa, Y. (2017) · Medicine · doi:10.1097/md.0000000000005995 · Cited by 13
Motion artifacts extraction using dwt from ambulatory ECG (A-ECG)
Bhoraniya, D., & Kher, R. (2014) · doi:10.1109/iccsp.2014.6950112 · Cited by 12
Novel textile systems for the continuous monitoring of vital signals: design and characterization
Trindade, I. G., Martins, F., Dias, R., Oliveira, C., & da Silva, J. M. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319207 · Cited by 12
Evaluation of ambulatory ECG sensors for a clinical trial on outpatient cardiac rehabilitation
Ding, H., Särelä, A., Helmer, R. J. N., Mestrovic, M. A., & Karunanithi, M. (2010) · ICME International Conference on Complex Medical Engineering (CME) · doi:10.1109/iccme.2010.5558835 · Cited by 11
El‐Sherif, N., & Turitto, G. (2015) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12222 · Cited by 11
A Low-Voltage Low-Power Front-End for Wearable EEG Systems
Yates, D. C., López-Morillo, E., Carvajal, R. G., Ramirez‐Angulo, J., & Rodriguez–Villegas, E. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353533 · Cited by 11
Frequency of Serious Arrhythmias Detected With Ambulatory Cardiac Telemetry
Kadish, A. H., Reiffel, J. A., Clauser, J., Prater, S. P., Menard, M., & Kopelman, H. A. (2010) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2009.12.047 · Cited by 10
Performance of a QRS detector on self-collected database using a handheld two-electrode ECG
Teeramongkonrasmee, A., Somboon, P., & Lek-uthai, A. (2017) · Biomedical Engineering International Conference · doi:10.1109/bmeicon.2017.8229137 · Cited by 10
A wearable healthcare system for cardiac signal monitoring using conductive textile electrodes
Lim, C. Y., Jang, K. J., Kim, H., et al. (2013) · doi:10.1109/embc.2013.6611293 · Cited by 9
Experimental Study and Evaluation of Paper-based Inkjet Electrodes for ECG Signal Acquisition
Alves, A. P., Martins, J. T. V., Silva, H., et al. (2014) · International Conference on Physiological Computing Systems (PhyCS) · doi:10.5220/0004720802750281 · Cited by 8
Rienzo, M. D., Rizzo, F., Meriggi, P., et al. (2009) · IEEE Engineering in Medicine and Biology Magazine · Cited by 8
Castaño, F. A., & Hernández, A. M. (2017) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-981-10-4086-3_107 · Cited by 8
She, L., Song, Y., Zhang, S., et al. (2010) · International Conference on Biomedical Engineering and Informatics (BMEI) · doi:10.1109/bmei.2010.5640071 · Cited by 7
2014 Pan American Health Care Exchanges (PAHCE)
(2014) · doi:10.1109/pahce33547.2014 · Cited by 7
A low-power wireless ECG processing node and remote monitoring system
O’Connell, E., O'Connell, S., McEvoy, R. P., et al. (2010) · IET Irish Signals and Systems Conference (ISSC) · doi:10.1049/cp.2010.0486 · Cited by 6
Artificial neural network-based classification of body movements in ambulatory ECG signal
Darji, S. T., & Kher, R. (2013) · Journal of Medical Engineering & Technology · doi:10.3109/03091902.2013.839750 · Cited by 6
Saarel, E. V., Doratotaj, S., & Sterba, R. (2008) · Congenital Heart Disease · doi:10.1111/j.1747-0803.2007.00162.x · Cited by 5
A wireless modular multi-modal multi-node patch platform for robust biosignal monitoring
Pantelopoulos, A., Saldı́var, E., & Roham, M. (2011) · doi:10.1109/iembs.2011.6091742 · Cited by 5
IEEE Asian Solid-State Circuits Conference 2011
(2011) · doi:10.1109/a-sscc19186.2011 · Cited by 5
Study of Hybrid Strategy for Ambulatory ECG Waveform Clustering
Zheng, G., & Tian, Y. (2011) · Journal of Software · doi:10.4304/jsw.6.7.1257-1264 · Cited by 4
Adaptive reduction of motion artefact in wireless physiological monitoring microsystems
Yang, Y.-S. O., Lee, W.-C., Ke, T.-C., et al. (2008) · International Conference on Sensing Technology · doi:10.1109/icsenst.2008.4757161 · Cited by 4
Ambulatory ECG (Holter) monitoring in management of acute myocardial ischemia.
Ga, I., Lambert, C. R., Ja, H., et al. (1988) · PubMed · Cited by 4
Chaudhuri, S., Pawar, T., & Duttagupta, S. P. (2009) · Springer eBooks · doi:10.1007/978-1-4419-0724-0_2 · Cited by 3
Research works printed but not linked: 5
- Benjamin, 2017, Heart disease and stroke statistics—2017 update, Circulation, 135, e146, 10.1161/CIR.0000000000000485 · DOI · Paper page
- 1985, CSE Working Party. Recommendations for measurement standards in quantitative electrocardiography, Eur. Heart J., 6, 815
- Ioannou, 2014, Ambulatory electrocardiography: the contribution of Norman jefferis holter, Brit Col Med Jour., 56, 86
- Romero, 2013, Ambulatory electrocardiology, Cardiol. Rev., 21, 239, 10.1097/CRD.0b013e31828a8294 · DOI
- Assambo, 2012, An optimized high-impedance amplifier for dry- electrode ECG recording, International Journal of Circuits Systems and Signal Processing, 6, 10
Cited by
Sorted by citations
Lee, S., Chu, Y., Ryu, J., Park, Y. J., Yang, S., & Koh, S. B. (2022) · Yonsei Medical Journal · doi:10.3349/ymj.2022.63.s93 · Cited by 88
Metadata
- Authors
- Periyaswamy, T., & Balasubramanian, M.
- Affiliations
- Central Michigan University (US)
- University of Arkansas at Fayetteville (US)
- Corresponding author
- Periyaswamy, Thamizhisai
- Venue
- International Journal of Medical Informatics
- Publisher
- Elsevier BV
- Published
- 2019-10
- Volume
- 130
- Pages
- 103928
- ISSN
- 1386-5056 (ISSN-L)
- OpenAlex
- W2958092670
- Cited by
- 14
- References
- 206
- Citations by year
- 2026: 3 · 2025: 1 · 2024: 1 · 2023: 1 · 2022: 3 · 2021: 4 · 2020: 1
- FWCI
- 0.16
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- International Journal of Medical Informatics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- Holter monitoring, wearable cardiac monitoring, remote diagnosis, telemedicine, wearable comfort, continuous cardiac monitoring
- MeSH terms
- Wearable Electronic Devices, Arrhythmias, Cardiac, Humans, Electrocardiography, Ambulatory, Telemedicine, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review