The DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Lab-on-a-chip devices: How to close and plug the lab?
Open accessAbstract
Lab-on-a-chip (LOC) devices are broadly used for research in the life sciences and diagnostics and represent a very fast moving field. LOC devices are designed, prototyped and assembled using numerous strategies and materials but some fundamental trends are that these devices typically need to be (1) sealed, (2) supplied with liquids, reagents and samples, and (3) often interconnected with electrical or microelectronic components. In general, closing and connecting to the outside world these miniature labs remain a challenge irrespectively of the type of application pursued. Here, we review methods for sealing and connecting LOC devices using standard approaches as well as recent state-of-the-art methods. This review provides easy-to-understand examples and targets the microtechnology/engineering community as well as researchers in the life sciences.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
A gas chromatographic air analyzer fabricated on a silicon wafer
Terry, S. C., Jerman, J. H., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19791 · Cited by 1,452
Three-dimensional microfluidic devices fabricated in layered paper and tape
Martinez, A. W., Phillips, S. T., & Whitesides, G. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810903105 · Cited by 1,246
SU-8: a low-cost negative resist for MEMS
Lorenz, H., Despont, M., Fahrni, N., LaBianca, N., Renaud, P., & Vettiger, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/010 · Cited by 979
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 958
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Recent developments in PDMS surface modification for microfluidic devices
Zhou, J., Ellis, A. V., & Voelcker, N. H. (2010) · ELECTROPHORESIS · doi:10.1002/elps.200900475 · Cited by 857
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Anisotropic etching of silicon
Bean, K. E. (1978) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1978.19250 · Cited by 803
Polymer microfabrication methods for microfluidic analytical applications
Becker, H., & Gärtner, C. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<12::aid-elps12>3.0.co;2-7 · Cited by 795
Chaotic mixing in three-dimensional microvascular networks fabricated by direct-write assembly
Therriault, D., White, S. R., & Lewis, J. A. (2003) · Nature Materials · doi:10.1038/nmat863 · Cited by 707
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Bonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
Abgrall, P., & Gué, A.-M. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/5/r01 · Cited by 561
PDMS-based microfluidic devices for biomedical applications
Fujii, T. (2002) · Microelectronic Engineering · doi:10.1016/s0167-9317(02)00494-x · Cited by 518
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Self-citationIntegration of paper-based microfluidic devices with commercial electrochemical readers
Nie, Z., Deiss, F., Liu, X., Akbulut, O., & Whitesides, G. M. (2010) · Lab on a Chip · doi:10.1039/c0lc00237b · Cited by 481
Micro-injection moulding of polymer microfluidic devices
Attia, U. M., Marson, S., & Alcock, J. R. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0421-x · Cited by 474
A nanoliter-scale nucleic acid processor with parallel architecture
Hong, J. W., Studer, V., Hang, G., Anderson, W. F., & Quake, S. R. (2004) · Nature Biotechnology · doi:10.1038/nbt951 · Cited by 470
Autonomous Microfluidic Capillary System
Juncker, D., Schmid, H., Drechsler, U., Wolf, H., Wolf, M., Michel, B., de Rooij, N., & Delamarche, E. (2002) · Analytical Chemistry · doi:10.1021/ac0261449 · Cited by 426
Self-citationMicrofluidic Networks for Chemical Patterning of Substrates: Design and Application to Bioassays
Delamarche, E., Bernard, A., Schmid, H., Bietsch, A., Michel, B., & Biebuyck, H. (1998) · Journal of the American Chemical Society · doi:10.1021/ja973071f · Cited by 412
Self-citationRapid prototyping polymers for microfluidic devices and high pressure injections
Sollier, E., Murray, C., Maoddi, P., & Di Carlo, D. (2011) · Lab on a Chip · doi:10.1039/c1lc20514e · Cited by 407
The Digital Revolution: A New Paradigm for Microfluidics
Abdelgawad, M., & Wheeler, A. R. (2009) · Advanced Materials · doi:10.1002/adma.200802244 · Cited by 382
Mail-order microfluidics: evaluation of stereolithography for the production of microfluidic devices
Au, A. K., Lee, W., & Folch, A. (2014) · Lab Chip · doi:10.1039/c3lc51360b · Cited by 380
A 128 x 128 cmos biosensor array for extracellular recording of neural activity
Eversmann, B., Jenkner, M., Hofmann, F., Paulus, C., Brederlow, R., Holzapfl, B., Fromherz, P., Merz, M., Brenner, M., Schreiter, M., et al. (2003) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.819174 · Cited by 375
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Microfluidics for medical diagnostics and biosensors
Rivet, C., Lee, H., Hirsch, A., Hamilton, S., & Lu, H. (2011) · Chemical Engineering Science · doi:10.1016/j.ces.2010.08.015 · Cited by 356
Mukhopadhyay, R. (2007) · Analytical Chemistry · doi:10.1021/ac071903e · Cited by 355
Ion-sensitive field-effect transistors fabricated in a commercial CMOS technology
Bausells, J., Carrabina, J., Errachid, A., & Merlos, A. (1999) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(99)00135-5 · Cited by 327
Lange, D., Hagleitner, C., Hierlemann, A., Brand, O., & Baltes, H. (2002) · Analytical Chemistry · doi:10.1021/ac011269j · Cited by 307
Cheng, S., & Wu, Z. (2012) · Lab on a Chip · doi:10.1039/c2lc21176a · Cited by 300
A facile route for irreversible bonding of plastic-PDMS hybrid microdevices at room temperature
Tang, L., & Lee, N. Y. (2010) · Lab on a Chip · doi:10.1039/b924753j · Cited by 267
Bartolo, D., Degré, G., Nghe, P., & Studer, V. (2008) · Lab Chip · doi:10.1039/b712368j · Cited by 265
Lab-on-a-Foil: microfluidics on thin and flexible films
Focke, M., Kosse, D., Müller, C., Reinecke, H., Zengerle, R., & von Stetten, F. (2010) · Lab on a Chip · doi:10.1039/c001195a · Cited by 255
Differentially photo-crosslinked polymers enable self-assembling microfluidics
Jamal, M., Zarafshar, A. M., & Gracias, D. H. (2011) · Nature Communications · doi:10.1038/ncomms1531 · Cited by 249
Low-temperature full wafer adhesive bonding
Niklaus, F., Enoksson, P., Kälvesten, E., & Stemme, G. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/2/303 · Cited by 244
Macro-to-micro interfaces for microfluidic devices
Fredrickson, C. K., & Fan, Z. H. (2004) · Lab on a Chip · doi:10.1039/b410720a · Cited by 225
Microfluidic systems with on-line UV detection fabricated in photodefinable epoxy
Jackman, R. J., Floyd, T. M., Ghodssi, R., Schmidt, M. A., & Jensen, K. F. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/3/316 · Cited by 220
Fobel, R., Fobel, C., & Wheeler, A. R. (2013) · Applied Physics Letters · doi:10.1063/1.4807118 · Cited by 218
Construction of microfluidic chips using polydimethylsiloxane for adhesive bonding
Wu, H., Huang, B., & Zare, R. N. (2005) · Lab on a Chip · doi:10.1039/b510494g · Cited by 212
A simple method for fabricating multi-layer PDMS structures for 3D microfluidic chips
Zhang, M., Wu, J., Wang, L., Xiao, K., & Wen, W. (2010) · Lab on a Chip · doi:10.1039/b923101c · Cited by 206
Ink jet printing nozzle arrays etched in silicon
BASSOUS, E., Taub, H. H., & Kuhn, L. (1977) · Applied Physics Letters · doi:10.1063/1.89587 · Cited by 201
Injection molded microfluidic chips featuring integrated interconnects
Mair, D. A., Geiger, E., Pisano, A. P., Fréchet, J. M. J., & Svec, F. (2006) · Lab Chip · doi:10.1039/b605911b · Cited by 193
Capillarics: pre-programmed, self-powered microfluidic circuits built from capillary elements
Safavieh, R., & Juncker, D. (2013) · Lab on a Chip · doi:10.1039/c3lc50691f · Cited by 190
Dry etching of polydimethylsiloxane for microfluidic systems
Garra, J., Long, T., Currie, J., Schneider, T., White, R., & Paranjape, M. (2002) · Journal of Vacuum Science & Technology A: Vacuum, Surfaces, and Films · doi:10.1116/1.1460896 · Cited by 188
Microfluidic channel fabrication in dry film resist for production and prototyping of hybrid chips
Vulto, P., Glade, N., Altomare, L., Bablet, J., Tin, L. D., Medoro, G., Chartier, I., Manaresi, N., Tartagni, M., & Guerrieri, R. (2005) · Lab on a Chip · doi:10.1039/b411885e · Cited by 187
Polyimide-based microfluidic devices
Metz, S., Holzer, R., & Renaud, P. (2001) · Lab on a Chip · doi:10.1039/b103896f · Cited by 185
Bonding of Glass Microfluidic Chips at Room Temperatures
Jia, Z.-J., Fang, Q., & Fang, Z.-L. (2004) · Analytical Chemistry · doi:10.1021/ac0494477 · Cited by 171
Rapid fabrication of pressure-driven open-channel microfluidic devices in omniphobic RF paper
Glavan, A. C., Martinez, R. V., Maxwell, E. J., Subramaniam, A. B., Nunes, R. M. D., Soh, S., & Whitesides, G. M. (2013) · Lab on a Chip · doi:10.1039/c3lc50371b · Cited by 167
A low temperature surface modification assisted method for bonding plastic substrates
Vlachopoulou, M.-E., Tserepi, A., Pavli, P., Argitis, P., Sanopoulou, M., & Misiakos, K. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/1/015007 · Cited by 164
Shrinky-Dink microfluidics: 3D polystyrene chips
Chen, C., Breslauer, D. N., Luna, J. I., Grimes, A., Chin, W., Lee, L. P., & Khine, M. (2008) · Lab on a Chip · doi:10.1039/b719029h · Cited by 152
Choi, K., Ng, A. H. C., Fobel, R., Chang-Yen, D. A., Yarnell, L. E., Pearson, E., Oleksak, C. M., Fischer, A. T., Luoma, R. P., Robinson, J. M., et al. (2013) · Analytical Chemistry · doi:10.1021/ac401847x · Cited by 148
Plastic–PDMS bonding for high pressure hydrolytically stable active microfluidics
Lee, K. S., & Ram, R. J. (2009) · Lab on a Chip · doi:10.1039/b820924c · Cited by 146
Becker, H. (2009) · Lab on a Chip · doi:10.1039/b916505n · Cited by 133
Thermoforming of Film‐Based Biomedical Microdevices
Truckenmüller, R. K., Giselbrecht, S., Rivron, N. C., Gottwald, E., Saile, V., van den Berg, A., Weßling, M., & van Blitterswijk, C. (2011) · Advanced Materials · doi:10.1002/adma.201003538 · Cited by 131
Kaigala, G. V., Lovchik, R. D., Drechsler, U., & Delamarche, E. (2011) · Langmuir · doi:10.1021/la2003639 · Cited by 113
Self-citationFolch, A. (2016) · CRC Press eBooks · doi:10.1201/b12263 · Cited by 104
An easy to assemble microfluidic perfusion device with a magnetic clamp
Tkachenko, E., Gutierrez, E., Ginsberg, M. H., & Groisman, A. (2009) · Lab on a Chip · doi:10.1039/b812184b · Cited by 89
Toward five-dimensional scaling: How density improves efficiency in future computers
Ruch, P., Brunschwiler, T., Escher, W., Paredes, S., & Michel, B. (2011) · IBM Journal of Research and Development · doi:10.1147/jrd.2011.2165677 · Cited by 87
Chitosan-mediated in situ biomolecule assembly in completely packaged microfluidic devices
Park, J. J., Luo, X., Yi, H., Valentine, T. M., Payne, G. F., Bentley, W. E., Reza Ghodssi, A., & Rubloff, G. W. (2006) · Lab on a Chip · doi:10.1039/b603101c · Cited by 80
Characterization of 3D-printed microfluidic chip interconnects with integrated O-rings
Paydar, O. H., Paredes, C. N., Hwang, Y., et al. (2013) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2013.11.005 · Cited by 78
Vulto, P., Huesgen, T., Albrecht, B., & Urban, G. A. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/7/077001 · Cited by 75
Wax-bonding 3D microfluidic chips
Gong, X., Yi, X., Xiao, K., Li, S., Kodzius, R., Qin, J., & Wen, W. (2010) · Lab on a Chip · doi:10.1039/c004744a · Cited by 71
Dentry, M. B., Friend, J. R., & Yeo, L. Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50933h · Cited by 71
Çiftlik, A. T., Lehr, H., & Gijs, M. A. M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1211273110 · Cited by 66
Re-usable multi-inlet PDMS fluidic connector
Saarela, V., Franssila, S., Tuomikoski, S., Marttila, S., Östman, P., Sikanen, T. M., Kotiaho, T., & Kostiainen, R. K. (2005) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2005.06.009 · Cited by 57
A doubly cross-linked nano-adhesive for the reliable sealing of flexible microfluidic devices
You, J. B., Min, K., Lee, B., Kim, D., & Im, S. G. (2013) · Lab on a Chip · doi:10.1039/c2lc41266g · Cited by 56
Zhang, Y., Dembla, A., & Bakir, M. S. (2013) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2013.2267492 · Cited by 56
Solder-based chip-to-tube and chip-to-chip packaging for microfluidic devices
Murphy, E. R., Inoue, T., Sahoo, H. R., Zaborenko, N., & Jensen, K. F. (2007) · Lab on a Chip · doi:10.1039/b704804a · Cited by 54
Novo, P., Chu, V., & Conde, J. P. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.02.009 · Cited by 49
Wafer Scale Integration of CMOS Chips for Biomedical Applications via Self-Aligned Masking
Uddin, A., Milaninia, K. M., Chen, C.-H., & Theogarajan, L. S. (2011) · IEEE Transactions on Components Packaging and Manufacturing Technology · doi:10.1109/tcpmt.2011.2166395 · Cited by 38
Chen, A., & Pan, T. (2010) · Lab on a Chip · doi:10.1039/c0lc00384k · Cited by 36
A low-temperature parylene-to-silicon dioxide bonding technique for high-pressure microfluidics
Çiftlik, A. T., & Gijs, M. A. M. (2011) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/21/3/035011 · Cited by 32
USB-driven microfluidic chips on printed circuit boards
Li, J., Wang, Y., Dong, E., & Chen, H. (2013) · Lab on a Chip · doi:10.1039/c3lc51155c · Cited by 29
Bianco, F., Tonna, N., Lovchik, R. D., Mastrangelo, R., Morini, R., Ruiz, A., Delamarche, E., & Matteoli, M. (2012) · Analytical Chemistry · doi:10.1021/ac302094z · Cited by 28
Self-citationÇiftlik, A. T., & Gijs, M. A. M. (2011) · Lab on a Chip · doi:10.1039/c1lc20727j · Cited by 27
Silicon couplers for microfluidic applications
Meng, E. F., Wu, S., & Tai, Y. (2001) · Fresenius Journal of Analytical Chemistry · doi:10.1007/s002160101002 · Cited by 26
Waldbaur, A., Kittelmann, J., Radtke, C. P., Hubbuch, J. J., & Rapp, B. E. (2013) · Lab on a Chip · doi:10.1039/c3lc00042g · Cited by 25
In-Plane Biocompatible Microfluidic Interconnects for Implantable Microsystems
Johnson, D. G., Frisina, R. D., & Borkholder, D. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2098031 · Cited by 24
Balasubramanian, V., Ruëdi, P.-F., Temiz, Y., Ferretti, A. M., Guiducci, C., & Enz, C. C. (2013) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2012.2234121 · Cited by 22
Self-citationFabrication of multilevel silicon structures by anisotropic deep silicon etching
Huber, R., Conrad, J., Schmitt, L., Hecker, K., Scheurer, J., & Weber, M. (2003) · Microelectronic Engineering · doi:10.1016/s0167-9317(03)00097-2 · Cited by 18
Cited by
The Hitchhiker’s Guide to Flow Chemistry
Plutschack, M. B., Pieber, B., Gilmore, K., & Seeberger, P. H. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00183 · Cited by 1,995
High-Spatial-Resolution Multi-Omics Sequencing via Deterministic Barcoding in Tissue
Liu, Y., Yang, M., Deng, Y., Su, G., Enninful, A., Guo, C. C., Tebaldi, T., Zhang, D., Kim, D., Bai, Z., et al. (2020) · Cell · doi:10.1016/j.cell.2020.10.026 · Cited by 966
“…was attached to the tissue section glass slides and a custom-designed acrylic clamp was used to firmly hold the PDMS against the tissue specimen to prevent leakage across microfluidic channels without the need for harsh bonding processed such as thermal bonding or plasma bonding (Temiz et al., 2015).”
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Point-of-care diagnostics for infectious diseases: From methods to devices
Wang, C., Liu, M., Wang, Z., Li, S., Deng, Y., & He, N. (2021) · Nano Today · doi:10.1016/j.nantod.2021.101092 · Cited by 622
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Metadata
- Authors
- Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E.
- Venue
- Microelectronic Engineering
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 132
- Pages
- 156-175
- ISSN
- 0167-9317 (ISSN-L)
- OpenAlex
- W2010550924
- Cited by
- 475
- References
- 90
- FWCI
- 19.70
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.