Time domain functional NIRS imaging for human brain mapping
Open accessThe DOI matches its Crossref record; 99 of the 99 references it cites were found in a registry or an index.
Abstract
This review is aimed at presenting the state-of-the-art of time domain (TD) functional near-infrared spectroscopy (fNIRS). We first introduce the physical principles, the basics of modeling and data analysis. Basic instrumentation components (light sources, detection techniques, and delivery and collection systems) of a TD fNIRS system are described. A survey of past, existing and next generation TD fNIRS systems used for research and clinical studies is presented. Performance assessment of TD fNIRS systems and standardization issues are also discussed. Main strengths and weakness of TD fNIRS are highlighted, also in comparison with continuous wave (CW) fNIRS. Issues like quantification of the hemodynamic response, penetration depth, depth selectivity, spatial resolution and contrast-to-noise ratio are critically examined, with the help of experimental results performed on phantoms or in vivo. Finally we give an account on the technological developments that would pave the way for a broader use of TD fNIRS in the neuroimaging community.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274 · cited 3×
“Nowadays, about thirty years after the first studies, there is only one dual-channel TD fNIRS commercial system (Hamamatsu Photonics, 2013e) not sold outside of Japan, while there are no commercial TD fNIRS imagers available (Contini et al., 2012; Ferrari and Quaresima, 2012).”
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087
Design and construction of a realistic digital brain phantom
Collins, D. L., Zijdenbos, A. P., Kollokian, V., Sled, J. G., Kabani, N. J., Holmes, C. J., & Evans, A. C. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.712135 · Cited by 1,822
Eggleton, B. J., Luther-Davies, B., & Richardson, K. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.309 · Cited by 1,574
Okamoto, M., Dan, H., Sakamoto, K., Takeo, K., Shimizu, K., Kohno, S., Oda, I., Isobe, S., Suzuki, T., Kohyama, K., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2003.08.026 · Cited by 1,320
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Metamaterials: a new frontier of science and technology
Liu, Y., & Zhang, X. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00184h · Cited by 1,086
Fang, Q., & Boas, D. A. (2009) · Optics Express · doi:10.1364/oe.17.020178 · Cited by 1,003
Optical biopsy and imaging using optical coherence tomography
Fujimoto, J. G., Brezinski, M. E., Tearney, G. J., Boppart, S. A., Bouma, B., Hee, M. R., Southern, J. F., & Swanson, E. A. (1995) · Nature Medicine · doi:10.1038/nm0995-970 · Cited by 887
A finite element approach for modeling photon transport in tissue
Arridge, S. R., Schweiger, M., Hiraoka, M., & Delpy, D. T. (1993) · Medical Physics · doi:10.1118/1.597069 · Cited by 635
Virtual spatial registration of stand-alone fNIRS data to MNI space
Tsuzuki, D., Jurcak, V., Singh, A. K., Okamoto, M., Watanabe, E., & Dan, I. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2006.10.043 · Cited by 630
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Boas, D. A., Culver, J. P., Stott, J. J., & Dunn, A. K. (2002) · Optics Express · doi:10.1364/oe.10.000159 · Cited by 599
Optical absorption of hemoglobin
Prahl, S. A. (1999) · Medical Entomology and Zoology · Cited by 579
Ballistic 2-D Imaging Through Scattering Walls Using an Ultrafast Optical Kerr Gate
Wang, L., Ho, P. P., Liu, C., Zhang, G., & Alfano, R. R. (1991) · Science · doi:10.1126/science.253.5021.769 · Cited by 552
The physiological origin of task-evoked systemic artefacts in functional near infrared spectroscopy
Kirilina, E., Jelzow, A., Heine, A., Niessing, M., Wabnitz, H., Brühl, R., Ittermann, B., Jacobs, A. M., & Tachtsidis, I. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.02.074 · Cited by 499
Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain.
Chance, B., Leigh, J. S., Miyake, H., Smith, D. S., Nioka, S., Greenfeld, R., Finander, M., Kaufmann, K., Levy, W., & Young, M. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.14.4971 · Cited by 464
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Alerstam, E., Svensson, T., & Andersson-Engels, S. (2008) · Journal of Biomedical Optics · doi:10.1117/1.3041496 · Cited by 407
Takahashi, T., Takikawa, Y., Kawagoe, R., Shibuya, S., Iwano, T., & Kitazawa, S. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.05.012 · Cited by 396
Mesh-based Monte Carlo method using fast ray-tracing in Plücker coordinates
Fang, Q. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000165 · Cited by 384
Near-infrared spectroscopy: A report from the McDonnell infant methodology consortium
Gervain, J., Mehler, J., Werker, J. F., Nelson, C. A., Csibra, G., Lloyd-Fox, S., Shukla, M., & Aslin, R. N. (2011) · Developmental Cognitive Neuroscience · doi:10.1016/j.dcn.2010.07.004 · Cited by 363
Short separation channel location impacts the performance of short channel regression in NIRS
Gagnon, L., Cooper, R. J., Yücel, M. A., Perdue, K. L., Greve, D. N., & Boas, D. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.08.095 · Cited by 312
Fukui, Y., Ajichi, Y., & Okada, E. (2003) · Applied Optics · doi:10.1364/ao.42.002881 · Cited by 286
A 32-channel time-resolved instrument for medical optical tomography
Schmidt, F. E. W., Fry, M. E., Hillman, E. M. C., Hebden, J. C., & Delpy, D. T. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150191 · Cited by 260
Determining changes in NIR absorption using a layered model of the human head
Steinbrink, J., Wabnitz, H., Obrig, H., Villringer, A., & Rinneberg, H. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/320 · Cited by 259
Boas, D. A., O'Leary, M. A., Chance, B., & Yodh, A. G. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.11.4887 · Cited by 248
Performance assessment of photon migration instruments: the MEDPHOT protocol
Pifferi, A., Torricelli, A., Bassi, A., Taroni, P., Cubeddu, R., Wabnitz, H., Grosenick, D., Möller, M., Macdonald, R., Swartling, J., et al. (2005) · Applied Optics · doi:10.1364/ao.44.002104 · Cited by 245
Self-citationGowar, J. (1984) · Cited by 242
Noninvasive Functional Imaging of Human Brain Using Light
Benaron, D. A., Hintz, S. R., Villringer, A., Boas, D., Kleinschmidt, A., Frahm, J., Hirth, C., Obrig, H., van Houten, J. C., Kermit, E. L., et al. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200003000-00005 · Cited by 239
Eggebrecht, A. T., White, B. R., Ferradal, S. L., Chen, C., Zhan, Y., Snyder, A. Z., Dehghani, H., & Culver, J. P. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.124 · Cited by 239
Martelli, F., Del Bianco, S., Ismaelli, A., & Zaccanti, G. (2009) · Florence Research (University of Florence) · doi:10.1117/3.824746 · Cited by 238
Ohmae, E., Ouchi, Y., Oda, M., Suzuki, T., Nobesawa, S., Kanno, T., Yoshikawa, E., Futatsubashi, M., Ueda, Y., Okada, H., et al. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.008 · Cited by 224
Gagnon, L., Yücel, M. A., Dehaes, M., Cooper, R. J., Perdue, K. L., Selb, J., Huppert, T. J., Hoge, R. D., & Boas, D. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.054 · Cited by 214
Photon migration in the presence of a single defect: a perturbation analysis
Feng, S., Zeng, F.-A., & Chance, B. (1995) · Applied Optics · doi:10.1364/ao.34.003826 · Cited by 192
Measurement of Optical Path Length for Cerebral Near-Infrared Spectroscopy in Newborn Infants
Wyatt, J. S., Cope, M., Delpy, D. T., van der Zee, P., Arridge, S., Edwards, A. D., & Reynolds, E. O. R. (1990) · Developmental Neuroscience · doi:10.1159/000111843 · Cited by 182
Saager, R. B., Telleri, N. L., & Berger, A. J. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.043 · Cited by 176
Torricelli, A., Pifferi, A., Taroni, P., Giambattistelli, E., & Cubeddu, R. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/8/313 · Cited by 173
Self-citationMultichannel time-resolved optical tomographic imaging system
Eda, H., Oda, I., Ito, Y., Wada, Y., Oikawa, Y., Tsunazawa, Y., Takada, M., Tsuchiya, Y., Yamashita, Y., Oda, M., et al. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149965 · Cited by 170
Hebden, J. C., Gibson, A. P., Austin, T., Yusof, R. M., Everdell, N. L., Delpy, D. T., Arridge, S., Meek, J. H., & Wyatt, J. S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/7/003 · Cited by 156
Selb, J. J., Stott, J. J., Franceschini, M. A., Sorensen, A. G., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852553 · Cited by 156
Time resolved propagation of ultrashort laser pulses within turbid tissues
Jacques, S. L. (1989) · Applied Optics · doi:10.1364/ao.28.002223 · Cited by 154
Pifferi, A., Torricelli, A. M., Spinelli, L., Contini, D., Cubeddu, R., Martelli, F., Zaccanti, G., Tosi, A., Mora, A. D. D., Zappa, F., et al. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.138101 · Cited by 152
Self-citationBoas, D. A., & Dale, A. M. (2005) · Applied Optics · doi:10.1364/ao.44.001957 · Cited by 152
Time-Domain Optical Mammography SoftScan: Initial Results
Intes, X., Djeziri, S., Ichalalène, Z., Mincu, N. E., Wang, Y., St.-Jean, P., Lesage, F., Hall, D. J., Boas, D. A., Polyzos, M., et al. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.08.029 · Cited by 150
Liebert, A., Wabnitz, H., Steinbrink, J. M., Møller, M., Macdonald, R., Rinneberg, H. H., Villringer, A., & Obrig, H. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.08.046 · Cited by 143
Anatomical atlas-guided diffuse optical tomography of brain activation
Custo, A., Boas, D. A., Tsuzuki, D., Dan, I., Mesquita, R. C., Fischl, B. R., Grimson, W. E. L., & Wells, W. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.033 · Cited by 137
Ijichi, S., Kusaka, T., Isobe, K., Okubo, K., Kawada, K., Namba, M., Okada, H., Nishida, T., Imai, T., & Itoh, S. (2005) · Pediatric Research · doi:10.1203/01.pdr.0000175638.98041.0e · Cited by 137
Time-Domain Optical Mammography SoftScan
Intes, X. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.05.006 · Cited by 134
Bianco, S. D., Martelli, F., & Zaccanti, G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/23/301 · Cited by 132
Diop, M., Verdecchia, K., Lee, T., & Lawrence, K. S. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.002068 · Cited by 129
Three-dimensional whole-head optical tomography of passive motor evoked responses in the neonate
Gibson, A. P., Austin, T., Everdell, N. L., Schweiger, M. J., Arridge, S., Meek, J. H., Wyatt, J. S., Delpy, D. T., & Hebden, J. C. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.08.059 · Cited by 127
In vivo optical imaging and dynamic contrast methods for biomedical research
Hillman, E. M. C., Amoozegar, C., Wang, T. S., McCaslin, A. F. H., Bouchard, M. B., Mansfield, J. R., & Levenson, R. M. (2011) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2011.0264 · Cited by 127
Experimental test of theoretical models for time-resolved reflectance
Cubeddu, R., Pifferi, A., Taroni, P., Torricelli, A. M., & Valentini, G. (1996) · Medical Physics · doi:10.1118/1.597739 · Cited by 123
Self-citationMulti-channel time-resolved system for functional near infrared spectroscopy
Contini, D., Torricelli, A. M., Pifferi, A., Spinelli, L., Paglia, F., & Cubeddu, R. (2006) · Optics Express · doi:10.1364/oe.14.005418 · Cited by 120
Self-citationCooper, R. J., Caffini, M., Dubb, J., Fang, Q., Custo, A., Tsuzuki, D., Fischl, B. R., Wells, W. M., Dan, I., & Boas, D. A. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.031 · Cited by 100
Self-citationAslin, R. N. (2012) · Cognitive Neuropsychology · doi:10.1080/02643294.2012.654773 · Cited by 100
Recent Progress in Silicon Photonics: A Review
Fang, Z., & Zhao, C. (2012) · ISRN Optics · doi:10.5402/2012/428690 · Cited by 99
Quaresima, V., Ferrari, M., Torricelli, A. M., Spinelli, L., Pifferi, A., & Cubeddu, R. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1851512 · Cited by 94
Self-citationTsuzuki, D., Cai, D., Dan, H., Kyutoku, Y., Fujita, A., Watanabe, E., & Dan, I. (2011) · Neuroscience Research · doi:10.1016/j.neures.2011.10.008 · Cited by 94
Multichannel photon counting instrument for spatially resolved near infrared spectroscopy
Ntziachristos, V., Ma, X., Yodh, A. G., & Chance, B. (1999) · Review of Scientific Instruments · doi:10.1063/1.1149565 · Cited by 93
Accelerating mesh-based Monte Carlo method on modern CPU architectures
Fang, Q., & Kaeli, D. R. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.003223 · Cited by 86
Near-infrared time-resolved spectroscopy system for tissue oxygenation monitor:
Oda, M., Yamashita, Y., Nakano, T., Suzuki, A., Shimizu, K., Hirano, I., Shimomura, F., Ohmae, E., Suzuki, T., & Tsuchiya, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356809 · Cited by 85
Time-Resolved Near-Infrared Spectroscopy and Imaging of the Adult Human Brain
Wabnitz, H., Moeller, M., Liebert, A., Obrig, H., Steinbrink, J. M., & Macdonald, R. (2009) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1241-1_20 · Cited by 71
Ijichi, S., Kusaka, T., Isobe, K., Islam, F., Okubo, K., Okada, H., Namba, M., Kawada, K., Imai, T., & Itoh, S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1899184 · Cited by 71
Diop, M., Tichauer, K. M., Elliott, J. T., Migueis, M., Lee, T., & Lawrence, K. S. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3488626 · Cited by 69
Torricelli, A. M., Quaresima, V., Pifferi, A., Biscotti, G., Spinelli, L., Taroni, P., Ferrari, M., & Cubeddu, R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/5/003 · Cited by 66
Self-citationAguirre, A. D., Chen, Y., Fujimoto, J. G., Ruvinskaya, L., Devor, A., & Boas, D. A. (2006) · Optics Letters · doi:10.1364/ol.31.003459 · Cited by 65
Compact tissue oximeter based on dual-wavelength multichannel time-resolved reflectance
Cubeddu, R., Pifferi, A., Taroni, P., Torricelli, A. M., & Valentini, G. (1999) · Applied Optics · doi:10.1364/ao.38.003670 · Cited by 63
Self-citationMackert, B., Leistner, S., Sander, T. H., Liebert, A., Wabnitz, H., Burghoff, M., Trahms, L., Macdonald, R., & Curio, G. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.09.037 · Cited by 62
Scarpa, F., Brigadoi, S., Cutini, S., Scatturin, P., Zorzi, M., Dell’Acqua, R., & Sparacino, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.01.021 · Cited by 60
Canova, D., Roatta, S., Bosone, D., & Micieli, G. (2011) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00003.2011 · Cited by 57
Exceptional Reduction of the Diffusion Constant in Partially Disordered Photonic Crystals
Toninelli, C., Vekris, E., Ozin, G. A., John, S., & Wiersma, D. S. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.123901 · Cited by 56
Relationship between time-resolved and non-time-resolved Beer - Lambert law in turbid media
Nomura, Y., Hazeki, O., & Tamura, M. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/6/002 · Cited by 51
Ohmae, E., Oda, M., Suzuki, T., Yamashita, Y., Kakihana, Y., Matsunaga, A., Kanmura, Y., & Tamura, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804931 · Cited by 51
Molteni, E., Baselli, G., Cerutti, S., Bianchi, A. M., Contini, D., Caffini, M., Cubeddu, R., Torricelli, A. M., & Spinelli, L. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.056005 · Cited by 50
Self-citationBrain and Muscle near Infrared Spectroscopy/Imaging Techniques
Contini, D., Zucchelli, L. M. G., Spinelli, L., Caffini, M., Re, R., Pifferi, A., Cubeddu, R., & Torricelli, A. M. (2012) · Journal of Near Infrared Spectroscopy · doi:10.1255/jnirs.977 · Cited by 50
Self-citationTime-resolved imaging of optical coefficients through murine chest cavities
Niedre, M. J., Turner, G. M., & Ntziachristos, V. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2400702 · Cited by 48
Biomedical Imaging: From Nano to Macro
Barber, P. R., Pierce, G., Ameer‐Beg, S., Matthews, D. R., Carlin, L. M., Epple, M., Festy, F., Gillett, C. E., Springall, R., Ng, T., et al. (2008) · Cited by 48
Aletti, F. M., Re, R., Pace, V., Contini, D., Molteni, E., Cerutti, S., Bianchi, A. M., Torricelli, A. M., Spinelli, L., Cubeddu, R., et al. (2011) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2011.06.001 · Cited by 44
Self-citationOptical Imaging of Brain Function
Gratton, G., & Fabiani, M. (2006) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195177619.003.0005 · Cited by 43
Cooper, R. J., Gagnon, L., Goldenholz, D. M., Boas, D. A., & Greve, D. N. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.11.028 · Cited by 41
Resting hypofrontality in schizophrenia: A study using near-infrared time-resolved spectroscopy
Hoshi, Y., Shinba, T., Sato, C., & Doi, N. (2006) · Schizophrenia Research · doi:10.1016/j.schres.2006.03.010 · Cited by 38
A compact time-resolved system for near infrared spectroscopy based on wavelength space multiplexing
Re, R., Contini, D., Caffini, M., Cubeddu, R., Spinelli, L., & Torricelli, A. M. (2010) · Review of Scientific Instruments · doi:10.1063/1.3495957 · Cited by 37
Self-citationLiebert, A., Wabnitz, H., & Elster, C. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.5.057005 · Cited by 35
Emerging Imaging Technologies in Medicine
Modregger, P., Pinzer, B. (., Wang, Z. (., & Stampanoni, M. (2012) · CRC Press eBooks · doi:10.1201/b13680 · Cited by 30
Sander, T. H., Liebert, A., Mackert, B.-M., Wabnitz, H., Leistner, S., Curio, G., Burghoff, M., Macdonald, R., & Trahms, L. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/6/004 · Cited by 30
Effect of prolonged stimulation on cerebral hemodynamic: A time‐resolved fNIRS study
Butti, M., Contini, D., Molteni, E., Caffini, M., Spinelli, L., Baselli, G., Bianchi, A. M., Cerutti, S., Cubeddu, R., & Torricelli, A. M. (2009) · Medical Physics · doi:10.1118/1.3190557 · Cited by 26
Self-citationSato, C., Yamaguchi, T., Seida, M., Ota, Y., Yu, I., Iguchi, Y., Nemoto, M., & Hoshi, Y. (2007) · Applied Optics · doi:10.1364/ao.46.002785 · Cited by 24
Yücel, M. A., Huppert, T. J., Boas, D. A., & Gagnon, L. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.04.036 · Cited by 23
Reflectance Diffuse Optical Tomography: Its Application to Human Brain Mapping
Ueda, Y., Yamanaka, T., Yamashita, D., Suzuki, T., Ohmae, E., Oda, M., & Yamashita, Y. (2005) · Japanese Journal of Applied Physics · doi:10.1143/jjap.44.l1203 · Cited by 22
Functional White-Laser Imaging to Study Brain Oxygen Uncoupling/Recoupling in Songbirds
Mottin, S., Montcel, B., de Chatellus, H. G., & Ramstein, S. (2010) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.2010.189 · Cited by 19
Bari, V., Calcagnile, P., Molteni, E., Re, R., Contini, D., Spinelli, L., Caffini, M., Torricelli, A. M., Cubeddu, R., Cerutti, S., et al. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/8/1379 · Cited by 17
Self-citationFerrari, M., Blasi, R. A. D., Safoue, F., Wei, Q., & Zaccanti, G. (1993) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-2468-1_3 · Cited by 13
Near-infrared spectroscopy in functional activation studies: New approaches
Obrig, H., Hirth, C., Ruben, J., Dirnagl, U., Villringer, A., Wabnitz, H., Grosenick, D., & Rinneberg, H. H. (1996) · NeuroImage · doi:10.1016/s1053-8119(96)80405-8 · Cited by 2
Cited by
Twenty years of functional near-infrared spectroscopy: introduction for the special issue
Boas, D. A., Elwell, C. E., Ferrari, M., & Taga, G. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.11.033 · Cited by 561
Broadband (550–1350 nm) diffuse optical characterization of thyroid chromophores
Konugolu Venkata Sekar, S., Farina, A., Dalla Mora, A., Lindner, C., Pagliazzi, M., Mora, M., Aranda, G., Dehghani, H., Durduran, T., Taroni, P., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-27684-8 · Cited by 549
Self-citationBest practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationUnderstanding near infrared spectroscopy and its application to skeletal muscle research
Barstow, T. J. (2019) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00166.2018 · Cited by 470
Quaresima, V., & Ferrari, M. (2019) · Organizational Research Methods · doi:10.1177/1094428116658959 · Cited by 419
Metadata
- Authors
- Torricelli, A., Contini, D., Pifferi, A., Caffini, M., Re, R., Zucchelli, L., & Spinelli, L.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2014-01
- Volume
- 85
- Pages
- 28-50
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W2001262493
- Cited by
- 466
- References
- 99
- FWCI
- 23.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.