Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome
Open accessThe DOI matches its Crossref record; 152 of the 152 references it cites were found in a registry or an index.
Abstract
The first phase of the Human Connectome Project pioneered advances in MRI technology for mapping the macroscopic structural connections of the living human brain through the engineering of a whole-body human MRI scanner equipped with maximum gradient strength of 300 mT/m, the highest ever achieved for human imaging. While this instrument has made important contributions to the understanding of macroscale connectional topology, it has also demonstrated the potential of dedicated high-gradient performance scanners to provide unparalleled in vivo assessment of neural tissue microstructure. Building on the initial groundwork laid by the original Connectome scanner, we have now embarked on an international, multi-site effort to build the next-generation human 3T Connectome scanner (Connectome 2.0) optimized for the study of neural tissue microstructure and connectional anatomy across multiple length scales. In order to maximize the resolution of this in vivo microscope for studies of the living human brain, we will push the diffusion resolution limit to unprecedented levels by (1) nearly doubling the current maximum gradient strength from 300 mT/m to 500 mT/m and tripling the maximum slew rate from 200 T/m/s to 600 T/m/s through the design of a one-of-a-kind head gradient coil optimized to minimize peripheral nerve stimulation; (2) developing high-sensitivity multi-channel radiofrequency receive coils for in vivo and ex vivo human brain imaging; (3) incorporating dynamic field monitoring to minimize image distortions and artifacts; (4) developing new pulse sequences to integrate the strongest diffusion encoding and highest spatial resolution ever achieved in the living human brain; and (5) calibrating the measurements obtained from this next-generation instrument through systematic validation of diffusion microstructural metrics in high-fidelity phantoms and ex vivo brain tissue at progressively finer scales with accompanying diffusion simulations in histology-based micro-geometries. We envision creating the ultimate diffusion MRI instrument capable of capturing the complex multi-scale organization of the living human brain - from the microscopic scale needed to probe cellular geometry, heterogeneity and plasticity, to the mesoscopic scale for quantifying the distinctions in cortical structure and connectivity that define cyto- and myeloarchitectonic boundaries, to improvements in estimates of macroscopic connectivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Nuclear Magnetic Resonance Microscopy
Callaghan, P. T. (1991) · doi:10.1093/oso/9780198539445.001.0001 · Cited by 3,599
Shank3 mutant mice display autistic-like behaviours and striatal dysfunction
Peça, J., Feliciano, C., Ting, J. T., Wang, W., Wells, M. F., Venkatraman, T. N., Lascola, C. D., Fu, Z., & Feng, G. (2011) · Nature · doi:10.1038/nature09965 · Cited by 1,570 · cited 1×
“Basic neuroscience is reaching a stage where alterations in cellular architecture and connectional anatomy are observed in animal models of disease and increasingly in human tissue, both locally and globally, in neuropsychiatric diseases such as autism (Drobnjak et al., 2011; Ianus et al., 2016; Peca et al., 2011; Pec…”
Dendritic spine pathology in neuropsychiatric disorders
Penzes, P., Cahill, M. E., Jones, K. A., VanLeeuwen, J.-E., & Woolfrey, K. M. (2011) · Nature Neuroscience · doi:10.1038/nn.2741 · Cited by 1,523 · cited 1×
“, 2011; Peca and Feng, 2012) and schizophrenia (Penzes et al., 2011), as well as in the earliest stages of neurodegenerative diseases (Herms and Dorostkar, 2016), in which gross structural alterations are invisible on conventional MRI.”
Setsompop, K., Gagoski, B. A., Polimeni, J. R., Witzel, T., Wedeen, V. J., & Wald, L. L. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23097 · Cited by 1,285 · cited 1×
“…multi-slab method that combines a novel “slice dithered ” RF slab encoding scheme ( Setsompop et al., 2017 ) with blipped controlled aliasing in parallel imaging (CAIPI) ( Setsompop et al., 2012 ) to enable SNR-efficient whole brain diffusion imaging at voxel sizes as small as 600 μm isotropic.”
Self-citationComposite hindered and restricted model of diffusion (CHARMED) MR imaging of the human brain
Assaf, Y., & Basser, P. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.03.042 · Cited by 856 · cited 1×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
Self-citationAxcaliber: A method for measuring axon diameter distribution from diffusion MRI
Assaf, Y., Blumenfeld‐Katzir, T., Yovel, Y., & Basser, P. J. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21577 · Cited by 849 · cited 3×
“Initially, quantifying axon diameter and density was done through approaches such as AxCaliber ( Assaf et al., 2008 ), based on the conventional PGSE sequence applied transverse to major axonal tracts.”
Self-citationUğurbil, K., Xu, J., Auerbach, E. J., Moeller, S., Vu, A. T., Duarte-Carvajalino, J. M., Lenglet, C., Wu, X., Schmitter, S., Van de Moortele, P. F., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.012 · Cited by 812 · cited 1×
“…commonplace in modern MRI machines, significantly reduce the spatially linear eddy current field patterns; however, eddy current fields of higher spatial order are well known ( Boesch et al., 1991 ; Van Vaals and Bergman, 1990 ) and can neither be compensated nor easily corrected in post-processing.”
Orientationally invariant indices of axon diameter and density from diffusion MRI
Alexander, D. C., Hubbard, P. L., Hall, M. G., Moore, E. A., Ptito, M., Parker, G. J. M., & Dyrby, T. B. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.05.043 · Cited by 683
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581 · cited 2×
“The spin PDF at shorter times retains more mesoscopic details in tissue features, whereas at long times the measured spin PDF is coarse-grained by diffusion and gradually loses the information (Novikov et al., 2019).”
Self-citationConcomitant gradient terms in phase contrast MR: Analysis and correction
Bernstein, M. A., Zhou, X. J., Polzin, J. A., King, K. F., Ganin, A., Pelc, N. J., & Glover, G. H. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390218 · Cited by 547 · cited 1×
“The integration of simultaneous field-camera measurements to provide real-time eddy current information is superior to non-simultaneous field-monitoring approaches as the presence of higher-order, nonlinear eddy current fields combined with significant nonlinear concomitant fields (Bernstein et al., 1998) at high grad…”
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545 · cited 7×
“The choice of 3 Tesla over 7 Tesla for the field strength of the original Connectome scanner was driven by the independence of diffusion contrast on B0 and the gains in sensitivity from the longer T2 relaxation times at 3T (Setsompop et al., 2013).”
InfluentialSelf-citationAssaf, Y., Freidlin, R. Z., Rohde, G. K., & Basser, P. J. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20274 · Cited by 519
Self-citationAn analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 1×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
Measurement of translational displacement probabilities by NMR: An indicator of compartmentation
Cory, D. G. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140303 · Cited by 429 · cited 10×
“DDE, though relatively less efficient, offers measurements of micro-anisotropy in a well-defined diffusion time scale.”
InfluentialImaging brain microstructure with diffusion MRI: practicality and applications
Alexander, D. C., Dyrby, T. B., Nilsson, M., & Zhang, H. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3841 · Cited by 424
Compartment models of the diffusion MR signal in brain white matter: A taxonomy and comparison
Panagiotaki, E., Schneider, T., Siow, B., Hall, M. G., Lythgoe, M. F., & Alexander, D. C. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2011.09.081 · Cited by 422 · cited 1×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
In vivo measurement of axon diameter distribution in the corpus callosum of rat brain
Barazany, D., Basser, P. J., & Assaf, Y. (2009) · Brain · doi:10.1093/brain/awp042 · Cited by 394 · cited 1×
“…vivo and animal studies on small-bore MRI systems ( Alexander, 2008 ; Alexander et al., 2010 ; Assaf and Basser, 2005 ; Assaf et al., 2008 ; 2004 , Barazany et al., 2009 ; Ferizi et al., 2013 ; Fieremans et al., 2016 ; Henriques et al., 2019 , 2020 ; Ianus et al., 2018 ; Jespersen et al., 2018…”
Self-citationÖzarslan, E., Koay, C. G., Shepherd, T. M., Komlosh, M. E., İrfanoğlu, M. O., Pierpaoli, C., & Basser, P. J. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.016 · Cited by 389
Self-citationThe Big and the Small: Challenges of Imaging the Brain’s Circuits
Lichtman, J. W., & Denk, W. (2011) · Science · doi:10.1126/science.1209168 · Cited by 370 · cited 1×
“A major challenge in studying the structural basis of brain function is the vast range of spatial scales spanned by brain networks, from synaptic circuits among individual neurons all the way to whole-brain systems (Lichtman and Denk, 2011).”
Self-citationNovikov, D. S., Kiselev, V. G., & Jespersen, S. N. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27101 · Cited by 366 · cited 2×
“…tissue microscale structure ( Alexander et al., 2017 ; Jelescu and Budde, 2017 ; Kiselev, 2017 ; Lampinen et al., 2019 ; Novikov et al., 2019 ; Novikov et al., 2018 ), such as the relative size and packing density of cells and axons using pulsed gradient and oscillating gradient spin echo…”
Self-citationThe Human Connectome Project and beyond: Initial applications of 300mT/m gradients
McNab, J. A., Edlow, B. L., Witzel, T., Huang, S. Y., Bhat, H., Heberlein, K., Feiweier, T., Liu, K., Keil, B., Cohen-Adad, J., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.074 · Cited by 359 · cited 3×
“An important and arguably more impactful byproduct of the original Connectome scanner was the sensitization of in vivo dMRI measurements to tissue microstructure at the micron scale ( McNab et al., 2013a ).”
Self-citationSANDI: a compartment‐based model for non‐invasive apparent soma and neurite imaging by diffusion MRI
Palombo, M., Ianus, A., Guerreri, M., Nunes, D., Alexander, D. C., Shemesh, N., & Zhang, H. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116835 · Cited by 349 · cited 1×
“advanced diffusion-encoding and modeling to map the microanatomical domains of the brain (Fischl and Sereno, 2018; Palombo et al., 2020).”
Revealing mesoscopic structural universality with diffusion
Novikov, D. S., Jensen, J. H., Helpern, J. A., & Fieremans, E. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1316944111 · Cited by 348 · cited 1×
“For example, shorter diffusion times may enable the detailed study of the theoretically predicted (Novikov et al., 2014) and recently found (Fieremans et al.”
Self-citationAlexander, D. C. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21646 · Cited by 331 · cited 2×
“…limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI systems ( Alexander, 2008 ; Alexander et al., 2010 ; Assaf and Basser, 2005 ; Assaf et al., 2008 ; 2004 , Barazany et al., 2009 ; Ferizi et al., 2013 ;…”
Q-space trajectory imaging for multidimensional diffusion MRI of the human brain
Westin, C.-F., Knutsson, H., Pasternak, O., Szczepankiewicz, F., Özarslan, E., van Westen, D., Mattisson, C., Bogren, M., O'Donnell, L. J., Kubicki, M., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.039 · Cited by 327 · cited 4×
“The DTD analytic framework has been applied to b-tensor imaging in the human brain on a clinical scanner (Westin et al., 2016) and is also being applied to DDE measurements on the living human brain using data acquired on the Connectome scanner.”
InfluentialHigh-contrast en bloc staining of neuronal tissue for field emission scanning electron microscopy
Tapia, J. C., Kasthuri, N., Hayworth, K. J., Schalek, R., Lichtman, J. W., Smith, S. J., & Buchanan, J. (2012) · Nature Protocols · doi:10.1038/nprot.2011.439 · Cited by 296
Self-citationDiffusion imaging of whole, post-mortem human brains on a clinical MRI scanner
Miller, K. L., Stagg, C. J., Douaud, G., Jbabdi, S., Smith, S. M., Behrens, T. E. J., Jenkinson, M., Chance, S. A., Esiri, M. M., Voets, N. L., et al. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.03.070 · Cited by 277
A 64‐channel 3T array coil for accelerated brain MRI
Keil, B., Blau, J. N., Biber, S., Hoecht, P., Tountcheva, V., Setsompop, K., Triantafyllou, C., & Wald, L. L. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24427 · Cited by 260 · cited 1×
“As part of the Human Connectome Project, a custom 64-channel brain receive-array coil was developed and validated on the original Connectome scanner, which enabled the highest SNR and highest quality accelerated human brain imaging at 3T to date ( Keil et al., 2013 ).”
Self-citationAxon diameter mapping in the presence of orientation dispersion with diffusion MRI
Zhang, H., Hubbard, P. L., Parker, G. J. M., & Alexander, D. C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.084 · Cited by 258
Multiple wave-vector extensions of the NMR pulsed-field-gradient spin-echo diffusion measurement
Mitra, P. P. (1995) · Physical Review B · doi:10.1103/physrevb.51.15074 · Cited by 258 · cited 11×
“DDE, though relatively less efficient, offers measurements of micro-anisotropy in a well-defined diffusion time scale.”
InfluentialMGH–USC Human Connectome Project datasets with ultra-high b-value diffusion MRI
Fan, Q., Witzel, T., Nummenmaa, A., Van Dijk, K. R. A., Van Horn, J. D., Drews, M. K., Somerville, L. H., Sheridan, M. A., Santillana, R. M., Snyder, J., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.08.075 · Cited by 254
Self-citationSzczepankiewicz, F., Lasič, S., van Westen, D., Sundgren, P. C., Englund, E., Westin, C.-F., Ståhlberg, F., Lätt, J., Topgaard, D., & Nilsson, M. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.057 · Cited by 250 · cited 4×
“has demonstrated evidence of microscopic anisotropy in human cortical gray matter in vivo (Jespersen et al., 2013; Lawrenz and Finsterbusch, 2019; Shemesh and Cohen, 2011; Szczepankiewicz et al., 2015).”
InfluentialOscillating gradient measurements of water diffusion in normal and globally ischemic rat brain
Does, M. D., Parsons, E. C., & Gore, J. C. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10385 · Cited by 246
Design and Validation of Diffusion MRI Models of White Matter
Jelescu, I. O., & Budde, M. D. (2017) · Frontiers in Physics · doi:10.3389/fphy.2017.00061 · Cited by 240 · cited 1×
“, 2016), the experience gained over the last decade has demonstrated that dedicated high-gradient performance scanners can also acquire a rich array of dMRI measurements that allow unparalleled in vivo assessment of neural tissue microscale structure (Alexander et al., 2017; Jelescu and Budde, 2017; Kiselev, 2017; Lam…”
The Axon : structure, function, and pathophysiology
Waxman, S. G. (1995) · Oxford University Press eBooks · Cited by 235
Quantitative mapping of the per‐axon diffusion coefficients in brain white matter
Kaden, E., Kruggel, F., & Alexander, D. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25734 · Cited by 234 · cited 1×
“Recently, it was suggested that to factor out the axonal orientation dispersion, as well as axonal undulations with wavelengths exceeding the diffusion length, one can employ directional averaging (Jespersen et al., 2013; Kaden et al., 2016; Mollink et al., 2017).”
Mesoscopic structure of neuronal tracts from time-dependent diffusion
Burcaw, L. M., Fieremans, E., & Novikov, D. S. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.03.061 · Cited by 234 · cited 6×
“…tissue snapshots of the underlying diffusion MRI physics and to achieve faithful ensemble averaging over all representative microenvironments, as well as providing the capability of studying mesoscopic fluctuations ( Burcaw et al., 2015 ) and biological variability over such length scales.”
InfluentialSelf-citationMultidimensional diffusion MRI
Topgaard, D. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2016.12.007 · Cited by 220 · cited 6×
“…; d ; Morozov et al., 2013 , Nunes et al., 2017 , Olesen et al., 2021 ; Ong and Wehrli, 2010 ; Ong et al., 2008 ; Panagiotaki et al., 2012 ; Stanisz et al., 1997 ; Szczepankiewicz et al., 2015 ; Tax et al., 2020 ; Topgaard, 2017 ; Veraart et al., 2020 ; Westin et al., 2016 ; Zhang et al., 2011 ).”
InfluentialHeilbronner, S. R., & Haber, S. N. (2014) · Journal of Neuroscience · doi:10.1523/jneurosci.5459-13.2014 · Cited by 202 · cited 1×
“Such topographies had previously been demonstrated by invasive tracer injection studies in non-human primates (Heilbronner and Haber, 2014; Lehman et al., 2011).”
Dendritic Spine Pathology in Neurodegenerative Diseases
Herms, J., & Dorostkar, M. M. (2016) · Annual Review of Pathology: Mechanisms of Disease · doi:10.1146/annurev-pathol-012615-044216 · Cited by 201 · cited 1×
“, 2011), as well as in the earliest stages of neurodegenerative diseases (Herms and Dorostkar, 2016), in which gross structural alterations are invisible on conventional MRI.”
Lampinen, B., Szczepankiewicz, F., Mårtensson, J., van Westen, D., Sundgren, P. C., & Nilsson, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.053 · Cited by 200 · cited 1×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
Jespersen, S. N., Lundell, H., Sønderby, C. K., & Dyrby, T. B. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2999 · Cited by 197 · cited 4×
“Recently, it was suggested that to factor out the axonal orientation dispersion, as well as axonal undulations with wavelengths exceeding the diffusion length, one can employ directional averaging (Jespersen et al., 2013; Kaden et al., 2016; Mollink et al., 2017).”
InfluentialAdes-Aron, B., Veraart, J., Kochunov, P., McGuire, S., Sherman, P., Kellner, E., Novikov, D. S., & Fieremans, E. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.07.066 · Cited by 193 · cited 1×
“, 2015), and the real-valued DWIs were processed using the DESIGNER pipeline (Ades-Aron et al., 2018).”
Self-citationLehman, J. F., Greenberg, B. D., McIntyre, C. C., Rasmussen, S. A., & Haber, S. N. (2011) · Journal of Neuroscience · doi:10.1523/jneurosci.0595-11.2011 · Cited by 191
Jones, D. K., Alexander, D. C., Bowtell, R., Cercignani, M., Dell'Acqua, F., McHugh, D. J., Miller, K. L., Palombo, M., Parker, G. J. M., Rudrapatna, U. S., et al. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.047 · Cited by 183
In vivo observation and biophysical interpretation of time-dependent diffusion in human white matter
Fieremans, E., Burcaw, L. M., Lee, H.-H., Lemberskiy, G., Veraart, J., & Novikov, D. S. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.01.018 · Cited by 181 · cited 2×
“, 2014) and recently found (Fieremans et al., 2016; Lee et al., 2020c) 1/ t power-law tail in the along-axon diffusion coefficient D∥ (t), originating from structurally disordered axonal beading.”
Self-citationHigher order reconstruction for MRI in the presence of spatiotemporal field perturbations
Wilm, B. J., Barmet, C., Pavan, M., & Pruessmann, K. P. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22767 · Cited by 181 · cited 1×
“0 scanner will make use of dynamic field monitoring and state-of-the-art image reconstruction techniques that incorporate the monitored field data to maximize the image quality and accuracy of diffusion MRI data measured in the new system (Wilm et al., 2011).”
Noninvasive quantification of axon radii using diffusion MRI
Veraart, J., Nunes, D., Rudrapatna, U., Fieremans, E., Jones, D. K., Novikov, D. S., & Shemesh, N. (2020) · eLife · doi:10.7554/elife.49855 · Cited by 180 · cited 5×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
InfluentialSelf-citationSafadi, Z., Grisot, G., Jbabdi, S., Behrens, T. E., Heilbronner, S. R., McLaughlin, N. C. R., Mandeville, J., Versace, A., Phillips, M. L., Lehman, J. F., et al. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.2335-17.2017 · Cited by 177 · cited 1×
“, 2016) have been shown to be capable of replicating these detailed topographies (Safadi et al., 2018), thanks to their high spatial resolution and SNR.”
Self-citationSetsompop, K., Fan, Q., Stockmann, J., Bilgic, B., Huang, S., Cauley, S. F., Nummenmaa, A., Wang, F., Rathi, Y., Witzel, T., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26653 · Cited by 177 · cited 2×
“(Setsompop et al., 2012) to enable SNR-efficient whole brain diffusion imaging at voxel sizes as small as 600 μm isotropic.”
Self-citationFrom Cajal to Connectome and Beyond
Swanson, L. W., & Lichtman, J. W. (2016) · Annual Review of Neuroscience · doi:10.1146/annurev-neuro-071714-033954 · Cited by 175 · cited 1×
“A necessary foundation and enormous challenge for human systems neuroscience is defining the connectome, the complete matrix of structural connections between the nodes of the nervous system, on multiple scales: the macro-connections across the entire brain at the level of centimeters to millimeters, the meso-connecti…”
Self-citationCharacterization of tissue structure at varying length scales using temporal diffusion spectroscopy
Gore, J. C., Xu, J., Colvin, D. C., Yankeelov, T. E., Parsons, E. C., & Does, M. D. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1531 · Cited by 173
Echo-Planar Imaging: Theory, Technique and Application
Schmitt, F., Stehling, M. K., Turner, R., & Bandettini, P. A. (2012) · Medical Entomology and Zoology · Cited by 170
Mollink, J., Kleinnijenhuis, M., Cappellen van Walsum, A.-M. V., Sotiropoulos, S. N., Cottaar, M., Mirfin, C., Heinrich, M. P., Jenkinson, M., Pallebage-Gamarallage, M., Ansorge, O., et al. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.06.001 · Cited by 170 · cited 1×
“…2016 ; Henriques et al., 2019 , 2020 ; Ianus et al., 2018 ; Jespersen et al., 2018 2019 ; Lampinen et al., 2017 ; Lee et al., 2018 ; , 2020c ; d ; Morozov et al., 2013 , Nunes et al., 2017 , Olesen et al., 2021 ; Ong and Wehrli, 2010 ; Ong et al., 2008 ; Panagiotaki et al., 2012 ; Stanisz et…”
The importance of axonal undulation in diffusion MR measurements: a Monte Carlo simulation study
Nilsson, M., Lätt, J., Ståhlberg, F., van Westen, D., & Hagslätt, H. (2012) · NMR in Biomedicine · doi:10.1002/nbm.1795 · Cited by 163 · cited 1×
“However, orientation dispersion and axonal undulations (Nilsson et al., 2012), among other effects, confound axonal diameter mapping.”
McNab, J. A., Polimeni, J. R., Wang, R., Augustinack, J. C., Fujimoto, K., Stevens, A., Janssens, T., Farivar, R., Folkerth, R. D., Vanduffel, W., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.11.065 · Cited by 158 · cited 2×
“A 3D diffusionweighted spin-echo multi-shot/segmented EPI sequence (Miller et al., 2011) was played out to achieve a reduced read-out duration, enabling reduced distortions and high SNR despite the characteristically short T2 relaxation time of postmortem brain tissue (Roebroeck et al.”
Self-citationIsotropic diffusion weighting in PGSE NMR by magic-angle spinning of the q-vector
Eriksson, S., Lasič, S., & Topgaard, D. (2012) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.10.015 · Cited by 154 · cited 1×
“, 2017), and b-tensor encoding schemes (Afzali et al., 2020; Eriksson et al., 2013; Szczepankiewicz et al., 2015; Topgaard, 2017; Westin et al., 2016) and may enable the distinction of microanatomical domains characterized by randomly oriented compartments of variable size and shape.”
Foo, T., Tan, E. T., Vermilyea, M. E., Hua, Y., Fiveland, E. W., Piel, J. E., Park, K., Ricci, J., Thompson, P. S., Graziani, D., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28087 · Cited by 149 · cited 1×
“The small inner diameter of the head gradient coil (compared to a conventional whole-body gradient coil) makes for a fundamentally efficient design ( Foo et al., 2018, 2020; Winkler et al., 2018 ), enabling high maximum gradient strength per unit current.”
Nilsson, M., Lasič, S., Drobnjak, I., Topgaard, D., & Westin, C. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3711 · Cited by 148 · cited 2×
“Furthermore, the near-doubling of Gmax to 500 mT/m will reduce the resolution limit (~1/ Gmax) of cell size by ~23% (Nilsson et al., 2017) and also act synergistically with shorter Δ to shorten the diffusion length ~(DΔ)1/2, subsequently increasing sensitivity to small compartment sizes.”
Contrast and stability of the axon diameter index from microstructure imaging with diffusion MRI
Dyrby, T. B., S⊘gaard, L. V., Hall, M. G., Ptito, M., & Alexander, D. C. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24501 · Cited by 146 · cited 1×
“Unfortunately, the effective diameter detectable using PGSE even with Gmax = 300 mT/m is only ~3 μm (Burcaw et al., 2015; Dyrby et al., 2012; Nilsson et al., 2017; Veraart et al., 2020), which is notably larger than the actual diameter of most axons in the brain (~1 μm or less) (Waxman et al.”
On the scaling behavior of water diffusion in human brain white matter
Veraart, J., Fieremans, E., & Novikov, D. S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.075 · Cited by 141 · cited 1×
“of zero axonal radius, the diffusion MRI signal follows the asymptotic power-law scaling S(b) 1/ b at strong diffusion weighting b (McKinnon et al., 2017; Veraart et al., 2019).”
Self-citationGradient and shim technologies for ultra high field MRI
Winkler, S. A., Schmitt, F., Landes, H., de Bever, J. T., Wade, T., Alejski, A., & Rutt, B. K. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.11.033 · Cited by 140 · cited 2×
“The small inner diameter of the head gradient coil (compared to a conventional whole-body gradient coil) makes for a fundamentally efficient design (Foo et al., 2018, 2020; Winkler et al., 2018), enabling high maximum gradient strength per unit current.”
The Axon: Structure, Function and Pathophysiology
Rietz, R. (1996) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1996.03530260071037 · Cited by 139
Physical and numerical phantoms for the validation of brain microstructural MRI: A cookbook
Fieremans, E., & Lee, H. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.06.046 · Cited by 135 · cited 1×
“We have developed an open-source software of diffusion simulations in realistic cell geometries from microscopy data (Fieremans and Lee, 2018; Lee et al., 2020a), providing a universal platform of model validation and protocol optimization for microstructural imaging using dMRI.”
Self-citationThe Diameter of Cortical Axons Depends Both on the Area of Origin and Target
Innocenti, G. M., Vercelli, A., & Caminiti, R. (2014) · Cerebral Cortex · doi:10.1093/cercor/bht070 · Cited by 130 · cited 1×
“5 × 106 per mm2, scaled to match the range of sizes spanned by myelinated axons in the human brain (Innocenti et al., 2014) and achieving an order of magnitude in reduction of diameter from previous textile-based phantoms (Guise et al.”
Mapping mean axon diameter and axonal volume fraction by MRI using temporal diffusion spectroscopy
Xu, J., Li, H., Harkins, K. D., Jiang, X., Xie, J., Kang, H., Does, M. D., & Gore, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.09.006 · Cited by 130 · cited 2×
“, 2018), such as the relative size and packing density of cells and axons using pulsed gradient and oscillating gradient spin echo sequences (Fan et al., 2020a; Huang et al., 2015; Huang et al., 2020; McNab et al., 2013a; Tax et al., 2020; Veraart et al., 2020; Xu, 2021; Xu et al., 2014) and microscopic anisotropy in…”
Ex vivo diffusion MRI of the human brain: Technical challenges and recent advances
Roebroeck, A., Miller, K. L., & Aggarwal, M. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3941 · Cited by 130 · cited 3×
“, 2011) was played out to achieve a reduced readout duration, enabling reduced distortions and high SNR despite the characteristically short T2 relaxation time of postmortem brain tissue (Roebroeck et al., 2019).”
InfluentialPGSE,OGSE, and sensitivity to axon diameter in diffusion MRI: Insight from a simulation study
Drobnjak, I., Zhang, H., Ianuş, A., Kaden, E., & Alexander, D. C. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25631 · Cited by 128 · cited 1×
“Specifically, low-frequency OGSE is advantageous in cases of unknown fiber direction and/or dispersion because it can achieve high sensitivity to axon diameter at a modest b-value, which avoids excessive signal attenuation due to freely diffusing water along the fiber direction (Drobnjak et al., 2016).”
Ong, H. H., Wright, A. C., Wehrli, S. L., Souza, A., Schwartz, E. D., Hwang, S. N., & Wehrli, F. W. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.017 · Cited by 126 · cited 1×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
Compartment shape anisotropy (CSA) revealed by double pulsed field gradient MR
Özarslan, E. (2009) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2009.04.002 · Cited by 125 · cited 11×
“DDE, though relatively less efficient, offers measurements of micro-anisotropy in a well-defined diffusion time scale.”
InfluentialLee, H.-H., Yaros, K., Veraart, J., Pathan, J. L., Liang, F.-X., Kim, S. G., Novikov, D. S., & Fieremans, E. (2019) · Brain Structure and Function · doi:10.1007/s00429-019-01844-6 · Cited by 125 · cited 2×
“…such as the axon diameter distribution, along-axon caliber variation, and orientation dispersion in the mouse corpus callosum using three-dimensional EM ( Abdollahzadeh et al., 2019 ; Lee et al., 2019 ) and in the macaque brain using synchrotron X-ray nano-holotomography ( Andersson et al., 2020 ).”
Self-citationFundamentals of diffusion MRI physics
Kiselev, V. G. (2017) · NMR in Biomedicine · doi:10.1002/nbm.3602 · Cited by 125 · cited 2×
“, 2016), the experience gained over the last decade has demonstrated that dedicated high-gradient performance scanners can also acquire a rich array of dMRI measurements that allow unparalleled in vivo assessment of neural tissue microscale structure (Alexander et al., 2017; Jelescu and Budde, 2017; Kiselev, 2017; Lam…”
Real diffusion-weighted MRI enabling true signal averaging and increased diffusion contrast
Eichner, C., Cauley, S., Cohen‐Adad, J., Möller, H. E., Turner, R., Setsompop, K., & Wald, L. L. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2015.07.074 · Cited by 124 · cited 1×
“The shot-to-shot phase variation in each complex-valued DWI was removed (Eichner et al., 2015), and the real-valued DWIs were processed using the DESIGNER pipeline (Ades-Aron et al.”
Self-citationSearching for the neurite density with diffusion MRI: challenges for biophysical modeling
Lampinen, B., Szczepankiewicz, F., Novén, M., van Westen, D., Hansson, O., Englund, E., Mårtensson, J., Westin, C., & Nilsson, M. (2019) · Human Brain Mapping · doi:10.1002/hbm.24542 · Cited by 123 · cited 1×
“, 2016), the experience gained over the last decade has demonstrated that dedicated high-gradient performance scanners can also acquire a rich array of dMRI measurements that allow unparalleled in vivo assessment of neural tissue microscale structure (Alexander et al., 2017; Jelescu and Budde, 2017; Kiselev, 2017; Lam…”
Diffusion time dependence of microstructural parameters in fixed spinal cord
Jespersen, S. N., Olesen, J. L., Hansen, B., & Shemesh, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.08.039 · Cited by 122
Lee, H.-H., Papaioannou, A., Novikov, D. S., & Fieremans, E. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117054 · Cited by 117
Self-citationAndersson, M., Kjer, H. M., Rafael‐Patiño, J., Pacureanu, A. T. J., Pakkenberg, B., Thiran, J., Ptito, M., Bech, M., Dahl, A. B., Dahl, V. A., et al. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2012533117 · Cited by 114 · cited 2×
“14), facilitating the validation and optimization of biophysical modeling of dMRI (Andersson et al., 2020; Chin et al., 2002; Lee et al., 2020c, e; Nguyen et al., 2018; Palombo et al., 2019; Xu et al., 2018).”
Avram, A. V., Sarlls, J. E., Barnett, A. S., Özarslan, E., Thomas, C., Irfanoglu, M. O., Hutchinson, E., Pierpaoli, C., & Basser, P. J. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.027 · Cited by 113 · cited 1×
“The diffusion time ( Δ ) dependence of MAP-MRI scalar parameters ( Avram et al., 2016 ; Özarslan et al., 2013 ) in a healthy volunteer ( Avram et al., 2021 ): Propagator Anisotropy (PA); Non-Gaussianity (NG); Return-to-axis probability (RTAP); and Return-to-origin-probability (RTOP).”
Self-citationThe impact of gradient strength on in vivo diffusion MRI estimates of axon diameter
Huang, S. Y., Nummenmaa, A., Witzel, T., Duval, T., Cohen-Adad, J., Wald, L. L., & McNab, J. A. (2015) · NeuroImage · doi:10.1016/j.neuroimage.2014.12.008 · Cited by 112 · cited 2×
“, 2018), such as the relative size and packing density of cells and axons using pulsed gradient and oscillating gradient spin echo sequences (Fan et al., 2020a; Huang et al., 2015; Huang et al., 2020; McNab et al., 2013a; Tax et al., 2020; Veraart et al., 2020; Xu, 2021; Xu et al., 2014) and microscopic anisotropy in…”
Self-citationKomlosh, M. E., Horkay, F., Freidlin, R. Z., Nevo, U., Assaf, Y., & Basser, P. J. (2007) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2007.07.003 · Cited by 109 · cited 10×
“DDE, though relatively less efficient, offers measurements of micro-anisotropy in a well-defined diffusion time scale.”
InfluentialSelf-citationShemesh, N., Özarslan, E., Komlosh, M. E., Basser, P. J., & Cohen, Y. (2010) · NMR in Biomedicine · doi:10.1002/nbm.1550 · Cited by 106 · cited 1×
“…, 2020c ; d ; Morozov et al., 2013 , Nunes et al., 2017 , Olesen et al., 2021 ; Ong and Wehrli, 2010 ; Ong et al., 2008 ; Panagiotaki et al., 2012 ; Stanisz et al., 1997 ; Szczepankiewicz et al., 2015 ; Tax et al., 2020 ; Topgaard, 2017 ; Veraart et al., 2020 ; Westin et al., 2016 ; Zhang et al.,…”
Self-citationOptimizing gradient waveforms for microstructure sensitivity in diffusion-weighted MR
Drobnjak, I., Siow, B. M., & Alexander, D. C. (2010) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2010.05.017 · Cited by 105
A high‐performance gradient insert for rapid and short‐T 2 imaging at full duty cycle
Weiger, M., Overweg, J., Rösler, M. B., Froidevaux, R., Hennel, F., Wilm, B. J., Penn, A., Sturzenegger, U., Schuth, W., Mathlener, M., et al. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26954 · Cited by 105
Chin, C., Wehrli, F. W., Hwang, S. N., Takahashi, M., & Hackney, D. B. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10078 · Cited by 103
A time-dependent diffusion MRI signature of axon caliber variations and beading
Lee, H.-H., Papaioannou, A., Kim, S.-L., Novikov, D. S., & Fieremans, E. (2020) · Communications Biology · doi:10.1038/s42003-020-1050-x · Cited by 102
Self-citationLightweight, compact, and high‐performance 3 T MR system for imaging the brain and extremities
Foo, T., Laskaris, E. T., Vermilyea, M. E., Xu, M., Thompson, P., Conte, G., Epps, C. V., Immer, C., Lee, S., Tan, E. T., et al. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27175 · Cited by 100 · cited 1×
“The small inner diameter of the head gradient coil (compared to a conventional whole-body gradient coil) makes for a fundamentally efficient design ( Foo et al., 2018, 2020; Winkler et al., 2018 ), enabling high maximum gradient strength per unit current.”
Gradient waveform design for tensor-valued encoding in diffusion MRI
Szczepankiewicz, F., Westin, C.-F., & Nilsson, M. (2021) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.109007 · Cited by 98 · cited 1×
“0 gradient system, as summarized by the product Gmax · maximum slew rate (Blasche, 2017; Szczepankiewicz et al., 2021), will be at least five times that of the most modern MRI systems available today, including the original Connectome MRI system equipped with Gmax of 300 mT/m and maximum slew rate of 200 T/m/s.”
Cellular and synaptic network defects in autism
Peça, J., & Feng, G. (2012) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2012.02.015 · Cited by 96 · cited 1×
“Basic neuroscience is reaching a stage where alterations in cellular architecture and connectional anatomy are observed in animal models of disease and increasingly in human tissue, both locally and globally, in neuropsychiatric diseases such as autism (Drobnjak et al., 2011; Ianus et al., 2016; Peca et al., 2011; Pec…”
Automated 3D Axonal Morphometry of White Matter
Abdollahzadeh, A., Belevich, I. N., Jokitalo, E., Tohka, J., & Sierra, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-42648-2 · Cited by 87 · cited 1×
“For example, previous work has quantitatively analyzed the microstructure in white matter axons, such as the axon diameter distribution, along-axon caliber variation, and orientation dispersion in the mouse corpus callosum using three-dimensional EM (Abdollahzadeh et al., 2019; Lee et al., 2019) and”
Microscopic anisotropy misestimation in spherical‐mean single diffusion encoding MRI
Henriques, R. N., Jespersen, S. N., & Shemesh, N. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27606 · Cited by 84 · cited 1×
“…Alexander et al., 2010 ; Assaf and Basser, 2005 ; Assaf et al., 2008 ; 2004 , Barazany et al., 2009 ; Ferizi et al., 2013 ; Fieremans et al., 2016 ; Henriques et al., 2019 , 2020 ; Ianus et al., 2018 ; Jespersen et al., 2018 2019 ; Lampinen et al., 2017 ; Lee et al., 2018 ; , 2020c ; d ; Morozov…”
Ong, H. H., & Wehrli, F. W. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.063 · Cited by 83 · cited 1×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
What dominates the time dependence of diffusion transverse to axons: Intra- or extra-axonal water?
Lee, H.-H., Fieremans, E., & Novikov, D. S. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.12.038 · Cited by 83 · cited 9×
“…diffusion times may enable the detailed study of the theoretically predicted ( Novikov et al., 2014 ) and recently found ( Fieremans et al., 2016 ; Lee et al., 2020c ) 1∕ √ 𝑡 power-law tail in the along-axon diffusion coefficient D || (t) , originating from structurally disordered axonal beading.”
InfluentialSelf-citationSerial-section electron microscopy using automated tape-collecting ultramicrotome (ATUM)
Baena, V., Schalek, R. L., Lichtman, J. W., & Terasaki, M. (2019) · Methods in Cell Biology · doi:10.1016/bs.mcb.2019.04.004 · Cited by 82 · cited 1×
“The cured block containing full-thickness cerebral cortex and subcortical white matter was trimmed to a 2 × 3 mm2 rectangle and a depth of 200 μm and imaged 8 × 8 × 30 nm3 using serial-section scanning EM (Sigma, Carl Zeiss) with a custom-built automated tape-collecting ultramicrotome (Baena et al., 2019).”
Self-citationDependence on b-value of the direction-averaged diffusion-weighted imaging signal in brain
McKinnon, E. T., Jensen, J. H., Glenn, G. R., & Helpern, J. A. (2017) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2016.10.026 · Cited by 80
Huang, S. Y., Tian, Q., Fan, Q., Witzel, T., Wichtmann, B., McNab, J. A., Daniel Bireley, J., Machado, N., Klawiter, E. C., Mekkaoui, C., et al. (2020) · Brain Structure and Function · doi:10.1007/s00429-019-01961-2 · Cited by 80
Self-citationCorrelation tensor magnetic resonance imaging
Henriques, R. N., Jespersen, S. N., & Shemesh, N. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116605 · Cited by 79
Tax, C. M. W., Szczepankiewicz, F., Nilsson, M., & Jones, D. K. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116534 · Cited by 77 · cited 3×
“, 2018), such as the relative size and packing density of cells and axons using pulsed gradient and oscillating gradient spin echo sequences (Fan et al., 2020a; Huang et al., 2015; Huang et al., 2020; McNab et al., 2013a; Tax et al., 2020; Veraart et al., 2020; Xu, 2021; Xu et al., 2014) and microscopic anisotropy in…”
The impact of realistic axonal shape on axon diameter estimation using diffusion MRI
Lee, H., Jespersen, S. N., Fieremans, E., & Novikov, D. S. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117228 · Cited by 77 · cited 9×
“…diffusion times may enable the detailed study of the theoretically predicted ( Novikov et al., 2014 ) and recently found ( Fieremans et al., 2016 ; Lee et al., 2020c ) 1∕ √ 𝑡 power-law tail in the along-axon diffusion coefficient D || (t) , originating from structurally disordered axonal beading.”
InfluentialSelf-citationShemesh, N., Özarslan, E., Adiri, T., Basser, P. J., & Cohen, Y. (2010) · The Journal of Chemical Physics · doi:10.1063/1.3454131 · Cited by 77 · cited 1×
“…1990 ; Henriques et al., 2021 ; Komlosh et al., 2007 ; Lawrenz and Finsterbusch, 2011 ; Mitra, 1995 ; Ozarslan, 2009 ; Shemesh and Cohen, 2011 ; Shemesh et al., 2010a , b ; Yang et al., 2018 ), double oscillating diffusion encoding (DODE) ( Ianus et al., 2017 ), and b -tensor encoding schemes…”
Self-citationFan, Q., Nummenmaa, A. R., Witzel, T., Ohringer, N. A., Tian, Q., Setsompop, K., Klawiter, E. C., Rosen, B. R., Wald, L. L., & Huang, S. Y. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117197 · Cited by 76
Self-citationWhite matter microstructure from nonparametric axon diameter distribution mapping
Benjamini, D., Komlosh, M. E., Holtzclaw, L. A., Nevo, U., & Basser, P. J. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.04.052 · Cited by 76 · cited 1×
“Nonparametric fiber diameter distributions of the micro phantoms were estimated from the DDE data based on a previously published analysis pipeline ( Benjamini et al., 2016 ).”
Self-citationJespersen, S. N., Olesen, J. L., Ianuș, A., & Shemesh, N. (2019) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2019.01.007 · Cited by 75
Shemesh, N., & Cohen, Y. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22738 · Cited by 74 · cited 1×
“…1990 ; Henriques et al., 2021 ; Komlosh et al., 2007 ; Lawrenz and Finsterbusch, 2011 ; Mitra, 1995 ; Ozarslan, 2009 ; Shemesh and Cohen, 2011 ; Shemesh et al., 2010a , b ; Yang et al., 2018 ), double oscillating diffusion encoding (DODE) ( Ianus et al., 2017 ), and b -tensor encoding schemes…”
In vivo human whole-brain Connectom diffusion MRI dataset at 760 µm isotropic resolution
Wang, F., Dong, Z., Tian, Q., Liao, C., Fan, Q., Hoge, W. S., Keil, B. R., Polimeni, J. R., Wald, L. L., Huang, S. Y., et al. (2021) · Scientific Data · doi:10.1038/s41597-021-00904-z · Cited by 74
Self-citationLee, S., Mathieu, J., Graziani, D., Piel, J. E., Budesheim, E., Fiveland, E. W., Hardy, C. J., Tan, E. T., Amm, B., Foo, T., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26044 · Cited by 74 · cited 2×
“Although most prominent for whole-body gradient coils, PNS is also becoming a significant concern for head gradients ( Lee et al., 2016b ), ( Weiger et al., 2017 ) ( Tan et al., 2019 ).”
Double diffusion encoding MRI for the clinic
Yang, G., Tian, Q., Leuze, C. W., Wintermark, M., & McNab, J. A. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27043 · Cited by 73 · cited 10×
“DDE, though relatively less efficient, offers measurements of micro-anisotropy in a well-defined diffusion time scale.”
InfluentialSelf-citationDavids, M., Guérin, B., Endt, A. V., Schad, L. R., & Wald, L. L. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27382 · Cited by 72
Self-citationResolving Fine Cardiac Structures in Rats with High-Resolution Diffusion Tensor Imaging
Teh, I., McClymont, D., Burton, R. A. B., Maguire, M. L., Whittington, H. J., Lygate, C. A., Köhl, P., & Schneider, J. E. (2016) · Scientific Reports · doi:10.1038/srep30573 · Cited by 70 · cited 1×
“, 2009) and has been used in recent precision diffusion studies of ex vivo tissue in preclinical MRI systems (Bastiani et al., 2016; Teh et al., 2016).”
Davids, M., Guérin, B., Malzacher, M., Schad, L. R., & Wald, L. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-05493-9 · Cited by 70
Self-citationMulti-Beam Scanning Electron Microscopy for High-Throughput Imaging in Connectomics Research
Eberle, A. L., & Zeidler, D. (2018) · Frontiers in Neuroanatomy · doi:10.3389/fnana.2018.00112 · Cited by 67 · cited 1×
“With the development of multibeam serial EM (Eberle and Zeidler, 2018), high-resolution images of human white matter now can be acquired at nanometer resolution over volumes of tissue comparable to the MRI voxel size (~mm).”
Liao, C., Bilgiç, B., Tian, Q., Stockmann, J., Cao, X., Fan, Q., Iyer, S., Wang, F., Ngamsombat, C., Lo, W., et al. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28748 · Cited by 64 · cited 1×
“To achieve distortion-free sub-millimeter diffusion imaging, gSlider-SMS has also been combined with blip-up/down acquisition (BUDA) for multi-shot EPI and dynamic B 0 shimming with a 32-channel AC/DC coil ( Liao et al., 2021 ).”
Self-citationAccurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain
Ianuș, A., Jespersen, S. N., Duarte, T. S., Alexander, D. C., Drobnjak, I., & Shemesh, N. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.08.034 · Cited by 63
Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI
Ianuș, A., Siow, B. M., Drobnjak, I., Zhang, H. G., & Alexander, D. C. (2012) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2012.11.021 · Cited by 63 · cited 2×
“Simulations were performed using the Microstructure Imaging Sequence Simulation ToolBox (MISST) (Drobnjak et al., 2010; Drobnjak et al., 2011; Ianus et al., 2013).”
Diffusion MRI with concurrent magnetic field monitoring
Wilm, B. J., Nagy, Z., Barmet, C., Vannesjo, S. J., Kasper, L., Haeberlin, M., Gross, S., Dietrich, B. E., Brunner, D. O., Schmid, T., et al. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25827 · Cited by 63 · cited 1×
“, 2016) will be incorporated into the 72-channel extended field-of-view coil for in vivo imaging and the 64-channel ex vivo whole brain coil to allow monitoring of the B0 and gradient fields simultaneously with the acquisition of in vivo and ex vivo human brain diffusion data (Wilm et al., 2015).”
Jones, R. J., Grisot, G., Augustinack, J. C., Magnain, C. V., Boas, D. A., Fischl, B. R., Wang, H., & Yendiki, A. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.116704 · Cited by 62 · cited 1×
“has an even greater impact than high angular resolution in resolving complex fiber configurations (Jones et al., 2020).”
Self-citationPalombo, M., Alexander, D. C., & Zhang, H. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.12.025 · Cited by 61 · cited 3×
“The figure is adapted from (Andersson et al., 2020; Chin et al., 2002; Lee et al., 2020c; Lee et al., 2020e; Nguyen et al., 2018; Palombo et al., 2019; Xu et al., 2018) with permission from Wiley, Elsevier, and Springer Nature.”
Fan, Q., Eichner, C., Afzali, M., Mueller, L., Tax, C. M. W., Davids, M., Mahmutović, M., Keil, B. R., Bilgiç, B., Setsompop, K., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.118958 · Cited by 59 · cited 2×
“, 2018), as discussed in greater extent in a separate review article included in this special issue (Fan et al., 2021).”
Self-citationLee, H., Fieremans, E., & Novikov, D. S. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.109018 · Cited by 58
Self-citationFan, Q., Nummenmaa, A. R., Witzel, T., Zanzonico, R., Keil, B. R., Cauley, S., Polimeni, J. R., Tisdall, M. D., Dijk, K. R. A. V., Buckner, R. L., et al. (2014) · Brain Connectivity · doi:10.1089/brain.2014.0305 · Cited by 57
Self-citationBusch, J., Vannesjo, S. J., Barmet, C., Pruessmann, K. P., & Kozerke, S. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0097-6 · Cited by 54 · cited 1×
“The rise in gradient coil temperature with higher gradient amplitudes (Busch et al., 2014) also breaks the time Huang et al.”
Fan, Q., Nummenmaa, A. R., Wichtmann, B. D., Witzel, T., Mekkaoui, C., Schneider, W., Wald, L. L., & Huang, S. Y. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.004 · Cited by 52 · cited 1×
“, 2016) used for validation of dMRI microstructural measures (Fan et al., 2018).”
Self-citationTan, E. T., Hua, Y., Fiveland, E. W., Vermilyea, M. E., Piel, J. E., Park, K. J., Ho, V. B., & Foo, T. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27909 · Cited by 52
The effect of realistic geometries on the susceptibility‐weighted MR signal in white matter
Xu, T., Foxley, S., Kleinnijenhuis, M., Chen, W. C., & Miller, K. L. (2017) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26689 · Cited by 51 · cited 1×
“14), facilitating the validation and optimization of biophysical modeling of dMRI (Andersson et al., 2020; Chin et al., 2002; Lee et al., 2020c, e; Nguyen et al., 2018; Palombo et al., 2019; Xu et al., 2018).”
Double diffusion encoding and applications for biomedical imaging
Henriques, R. N., Palombo, M., Jespersen, S. N., Shemesh, N., Lundell, H., & Ianuș, A. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108989 · Cited by 49 · cited 10×
“DDE, though relatively less efficient, offers measurements of micro-anisotropy in a well-defined diffusion time scale.”
InfluentialXu, J. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.109024 · Cited by 47 · cited 4×
“, 2018), such as the relative size and packing density of cells and axons using pulsed gradient and oscillating gradient spin echo sequences (Fan et al., 2020a; Huang et al., 2015; Huang et al., 2020; McNab et al., 2013a; Tax et al., 2020; Veraart et al., 2020; Xu, 2021; Xu et al., 2014) and microscopic anisotropy in…”
InfluentialRamos‐Llordén, G., Ning, L., Liao, C., Mukhometzianov, R., Michailovich, O., Setsompop, K., & Rathi, Y. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28232 · Cited by 46 · cited 1×
“0 project will push the limit of slice encoding and simultaneously enable reconstruction methods that enforce smoothness constraints in k- and q-space to allow subsampled RF and q-space encoding (Ramos-Llorden et al., 2020).”
Self-citationOptimization of MRI Gradient Coils With Explicit Peripheral Nerve Stimulation Constraints
Davids, M., Guérin, B., Klein, V., & Wald, L. L. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2020.3023329 · Cited by 45
Self-citationTemporal scaling characteristics of diffusion as a new MRI contrast: Findings in rat hippocampus
Özarslan, E., Shepherd, T. M., Koay, C. G., Blackband, S. J., & Basser, P. J. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.105 · Cited by 43
Self-citationBastiani, M., Oros‐Peusquens, A., Seehaus, A., Brenner, D., Möllenhoff, K., Celik, A., Felder, J., Bratzke, H., Shah, N. J., Galuske, R. A. W., et al. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00487 · Cited by 42 · cited 1×
“, 2009) and has been used in recent precision diffusion studies of ex vivo tissue in preclinical MRI systems (Bastiani et al., 2016; Teh et al., 2016).”
Model‐based estimation of microscopic anisotropy using diffusion MRI: a simulation study
Ianuș, A., Drobnjak, I., & Alexander, D. C. (2016) · NMR in Biomedicine · doi:10.1002/nbm.3496 · Cited by 39 · cited 1×
“Basic neuroscience is reaching a stage where alterations in cellular architecture and connectional anatomy are observed in animal models of disease and increasingly in human tissue, both locally and globally, in neuropsychiatric diseases such as autism (Drobnjak et al., 2011; Ianus et al., 2016; Peca et al., 2011; Pec…”
Kakkar, L. S., Bennett, O. F., Siow, B., Richardson, S., Ianuş, A., Quick, T., Atkinson, D., Phillips, J. B., & Drobnjak, I. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.060 · Cited by 38 · cited 1×
“…have been proposed to preserve excised nervous tissue in a viable physiological state that preserves the structural complexity of the tissue ( Kakkar et al., 2018 ; Richardson et al., 2013 ) and may be adopted to ensure that the diffusion properties of excised tissue emulate those observed in…”
Double oscillating diffusion encoding and sensitivity to microscopic anisotropy
Ianuș, A., Shemesh, N., Alexander, D. C., & Drobnjak, I. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26393 · Cited by 37 · cited 3×
“, 2018), double oscillating diffusion encoding (DODE) (Ianus et al., 2017), and b-tensor encoding schemes (Afzali et al.”
Microstructural parcellation of the human brain
Fischl, B. R., & Sereno, M. I. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.01.036 · Cited by 35 · cited 1×
“advanced diffusion-encoding and modeling to map the microanatomical domains of the brain (Fischl and Sereno, 2018; Palombo et al., 2020).”
Benjamini, D., Hutchinson, E. B., Komlosh, M. E., Comrie, C. J., Schwerin, S. C., Zhang, G., Pierpaoli, C. M., & Basser, P. J. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117195 · Cited by 35
Self-citationOptimising time-varying gradient orientation for microstructure sensitivity in diffusion-weighted MR
Drobnjak, I., & Alexander, D. C. (2011) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2011.07.017 · Cited by 35 · cited 1×
“A necessary foundation and enormous challenge for human systems neuroscience is defining the connectome, the complete matrix of structural connections between the nodes of the nervous system, on multiple scales: the macro-connections across the entire brain at the level of centimeters to millimeters, the meso-connecti…”
Nonparametric pore size distribution using d-PFG: Comparison to s-PFG and migration to MRI
Benjamini, D., Komlosh, M. E., Basser, P. J., & Nevo, U. (2014) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2014.06.017 · Cited by 33 · cited 1×
“13 shows the pore diameter distributions estimated from DDE measurements (Benjamini et al., 2014) using the NIH Bruker 7T equipped with a Micro2.”
Self-citationLawrenz, M., & Finsterbusch, J. (2018) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27451 · Cited by 28 · cited 1×
“has demonstrated evidence of microscopic anisotropy in human cortical gray matter in vivo (Jespersen et al., 2013; Lawrenz and Finsterbusch, 2019; Shemesh and Cohen, 2011; Szczepankiewicz et al., 2015).”
Guise, C., Fernandes, M. M., Nóbrega, J. M., Pathak, S., Schneider, W., & Fangueiro, R. M. E. S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b09809 · Cited by 28 · cited 1×
“The original Connectome scanner had a 60-channel “panini press ” brain slice array coil ( Gruber et al., 2014 ) designed and constructed for imaging of human brain slabs of up to 3 inches in thickness with sufficient sensitivity for single-average high-angular resolution diffusion imaging at 350 μm…”
Self-citationA new framework for MR diffusion tensor distribution
Magdoom, K. N., Pajevic, S., Gasbarra, D., & Basser, P. J. (2021) · Scientific Reports · doi:10.1038/s41598-021-81264-x · Cited by 28 · cited 1×
“To capture the complex microstructural organization of brain tissue, the DTD framework has been developed to extract information regarding diffusion anisotropy within the imaging voxel (Magdoom et al., 2021; Westin et al., 2016) by considering a parametrized normal tensor-variate distribution of diffusion tensors.”
Self-citationNguyen, K.-V., Hernández-Garzón, E., & Valette, J. (2018) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2018.09.013 · Cited by 27 · cited 4×
“(Nilsson et al., 2017) and also act synergistically with shorter to shorten the diffusion length ~(D) 1/2 ,”
InfluentialMapping axonal density and average diameter using non-monotonic time-dependent gradient-echo MRI
Nunes, D., Cruz, T. L., Jespersen, S. N., & Shemesh, N. (2017) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2017.02.017 · Cited by 27 · cited 1×
“…2019 , 2020 ; Ianus et al., 2018 ; Jespersen et al., 2018 2019 ; Lampinen et al., 2017 ; Lee et al., 2018 ; , 2020c ; d ; Morozov et al., 2013 , Nunes et al., 2017 , Olesen et al., 2021 ; Ong and Wehrli, 2010 ; Ong et al., 2008 ; Panagiotaki et al., 2012 ; Stanisz et al., 1997 ;…”
Davids, M., Guérin, B., Klein, V., Schmelz, M., Schad, L. R., & Wald, L. L. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab52bd · Cited by 22 · cited 1×
“To achieve this goal, we are leveraging recently developed simulation tools for the accurate prediction of PNS thresholds using realistic whole-body human nerve models in combination with electric field simulations ( Davids et al., 2020a , b , 2017 , 2019 , 2021b ).”
Self-citationScholz, A., Etzel, R., May, M. W., Mahmutović, M., Tian, Q., Ramos‐Llordén, G., Maffei, C., Bilgiç, B., Witzel, T., Stockmann, J., et al. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.118256 · Cited by 22 · cited 3×
“In order to map the connectomics of the whole human brain with high spatial resolution, a close-fitting 48-channel ex vivo whole brain coil has recently been developed for the original Connectome scanner (Scholz et al., 2021).”
InfluentialSelf-citationKomlosh, M. E., Benjamini, D., Hutchinson, E. B., King, S. G., Haber, M., Avram, A., Holtzclaw, L. A., Desai, A., Pierpaoli, C. M., & Basser, P. J. (2017) · Microporous and Mesoporous Materials · doi:10.1016/j.micromeso.2017.05.030 · Cited by 20
Self-citationAfzali, M., Aja‐Fernández, S., & Jones, D. K. (2020) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28191 · Cited by 18 · cited 1×
“, 2017), and b-tensor encoding schemes (Afzali et al., 2020; Eriksson et al., 2013; Szczepankiewicz et al., 2015; Topgaard, 2017; Westin et al., 2016) and may enable the distinction of microanatomical domains characterized by randomly oriented compartments of variable size and shape.”
Ferizi, U., Schneider, T., Tariq, M., Wheeler‐Kingshott, C. A. M. G., Zhang, H. G., & Alexander, D. C. (2013) · Lecture notes in computer science · doi:10.1007/978-3-642-40811-3_10 · Cited by 17 · cited 1×
“However, robust methods for in vivo mapping of tissue microstructure by dMRI remain elusive due to the demand for fast and strong diffusion-encoding gradients, which has largely limited such studies to region-of-interest analyses in clinical/preclinical MRI systems or ex vivo and animal studies on small-bore MRI syste…”
Benjamini, D., & Basser, P. J. (2014) · The Journal of Chemical Physics · doi:10.1063/1.4901134 · Cited by 17 · cited 10×
“DDE, though relatively less efficient, offers measurements of micro-anisotropy in a well-defined diffusion time scale.”
InfluentialSelf-citationRichardson, S., Siow, B. M., Batchelor, A. M., Lythgoe, M. F., & Alexander, D. C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24410 · Cited by 16 · cited 1×
“…to preserve excised nervous tissue in a viable physiological state that preserves the structural complexity of the tissue ( Kakkar et al., 2018 ; Richardson et al., 2013 ) and may be adopted to ensure that the diffusion properties of excised tissue emulate those observed in vivo as closely as…”
Modeling of the diffusion MR signal in calibrated model systems and nerves
Morozov, D., Bar, L., Sochen, N., & Cohen, Y. (2013) · NMR in Biomedicine · doi:10.1002/nbm.3018 · Cited by 15
Olesen, J. L., Østergaard, L., Shemesh, N., & Jespersen, S. N. (2021) · NeuroImage · doi:10.1016/j.neuroimage.2021.117849 · Cited by 13
A Huygens’ surface approach to rapid characterization of peripheral nerve stimulation
Davids, M., Guérin, B., & Wald, L. L. (2021) · Magnetic Resonance in Medicine · doi:10.1002/mrm.28966 · Cited by 12
Self-citationIn vivo human whole-brain Connectom diffusion MRI dataset at 760 μm isotropic resolutionPreprint
Wang, F., Dong, Z., Tian, Q., Liao, C., Fan, Q., Hoge, W. S., Keil, B. R., Polimeni, J. R., Wald, L. L., Huang, S. Y., et al. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.10.05.327395 · Cited by 5
Self-citation
Cited by
A petavoxel fragment of human cerebral cortex reconstructed at nanoscale resolution
Shapson-Coe, A., Januszewski, M., Berger, D. R., Pope, A., Wu, Y., Blakely, T., Schalek, R. L., Li, P. H., Wang, S., Maitin-Shepard, J., et al. (2024) · Science · doi:10.1126/science.adk4858 · Cited by 361
“These axon orientations can be used to validate diffusion tensor imaging signals in the human brain in vivo ( 43 , 44 ).”
BackgroundSelf-citationNext-generation MRI scanner designed for ultra-high-resolution human brain imaging at 7 Tesla
Feinberg, D. A., Beckett, A. J. S., Vu, A. T., Stockmann, J., Huber, L., Ma, S., Ahn, S., Setsompop, K., Cao, X., Park, S., et al. (2023) · Nature Methods · doi:10.1038/s41592-023-02068-7 · Cited by 196
“The timing parameters for a bipolar gradient waveform achieving this ES were calculated, and the maximum gradient that could be used within PNS limits was identified, corresponding to a Gmax of 98 mT m −1 and an SR 213 T m −1 s −1 .”
InfluentialSelf-citationEngineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Self-citation
Metadata
- Authors
- Huang, S. Y., Witzel, T., Keil, B., Scholz, A., Davids, M., Dietz, P., Rummert, E., Ramb, R., Kirsch, J. E., Yendiki, A., Fan, Q., Tian, Q., Ramos-Llordén, G., Lee, H.-H., Nummenmaa, A., Bilgic, B., Setsompop, K., Wang, F., Avram, A. V., Komlosh, M., Benjamini, D., Magdoom, K. N., Pathak, S., Schneider, W., Novikov, D. S., Fieremans, E., Tounekti, S., Mekkaoui, C., Augustinack, J., Berger, D., Shapson-Coe, A., Lichtman, J., Basser, P. J., Wald, L. L., & Rosen, B. R.
- Venue
- NeuroImage
- Publisher
- Elsevier BV
- Published
- 2021-11
- Volume
- 243
- Pages
- 118530
- ISSN
- 1053-8119 (ISSN-L)
- OpenAlex
- W3198254109
- Cited by
- 181
- References
- 152
- FWCI
- 11.66
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.