Challenges and strategies of matrix effects using chromatography-mass spectrometry: An overview from research versus regulatory viewpoints
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstract Matrix components of a sample can affect the quantitative measurement of the target analytes. This singularity is named “matrix effects” and should be considered for method validation procedure. Two main strategies to overcome matrix effects were suggested in the scientific literature: reducing the presence of components responsible for the effects and compensating the influence of matrix effects in the calibration methodology. It has been recommended that the best option to surpass matrix effects at research level is to establish a systematic optimization by the combination of approaches. On the other hand, from the method validation regulatory viewpoint, the information contained in the different method validation guidelines about matrix effects was uncommon. In fact, only in 54% of the evaluated regulatory documents the term matrix effects was mentioned explicitly in their contents. In addition, in the rest of the guidance documents addressing matrix effects, the subject was typically considered only superficially.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anastassiades, M., Lehotay, S. J., Štajnbaher, D., & Schenck, F. J. (2003) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/86.2.412 · Cited by 5,670
Research works printed but not linked: 51
- Raposo, 2020, Performance parameters for analytical method validation: controversies and discrepancies among numerous guidelines, TrAC Trends Anal. Chem., 129, 115913, 10.1016/j.trac.2020.115913 · DOI
- Dams, 2003, Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: influence of ionization type, sample preparation, and biofluid, J. Am. Soc. Mass Spectrom., 14, 1290, 10.1016/S1044-0305(03)00574-9 · DOI · Paper page
- Panuwet, 2016, Biological matrix effects in quantitative tandem mass spectrometry-based analytical methods: advancing biomonitoring, Crit. Rev. Anal. Chem., 46, 93, 10.1080/10408347.2014.980775 · DOI · Paper page
- Rogatsky, 2005, Evaluation of matrix effect and chromatography efficiency: new parameters for validation of method development, J. Am. Soc. Mass Spectrom., 16, 1757, 10.1016/j.jasms.2005.07.012 · doi:10.1016/j.jasms.2005.07.012
- Hoff, 2015, Analytical quality assurance in veterinary drug residue analysis methods: matrix effects determination and monitoring for sulfonamides analysis, Talanta, 132, 443, 10.1016/j.talanta.2014.08.046 · doi:10.1016/j.talanta.2014.08.046
- Raposo, 2016, Evaluation of analytical calibration based on least-squares linear regression for instrumental techniques: a tutorial review, TrAC Trends Anal. Chem., 77, 167, 10.1016/j.trac.2015.12.006 · doi:10.1016/j.trac.2015.12.006
- Shah, 2000, Bioanalytical method validation - a revisit with a decade of progress, Pharm. Res., 17, 1551, 10.1023/A:1007669411738 · DOI · Paper page
- Guilbault, 1989, Nomenclature for automated and mechanized analysis, Pure Appl. Chem., 61, 1657, 10.1351/pac198961091657 · DOI
- Huang, 2012, Matrix effect and recovery terminology issues in regulated drug bioanalysis, Bioanalysis, 4, 271, 10.4155/bio.11.315 · DOI
- Ellison, 2008, Standard additions: myth and reality, Analyst, 133, 992, 10.1039/b717660k · doi:10.1039/b717660k
- Matuszewski, 2003, Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC-MS/MS, Anal. Chem., 75, 3019, 10.1021/ac020361s · DOI · Paper page
- Kebarle, 1993, From ions in solution to ions in the gas phase: the mechanism of electrospray mass spectrometry, Anal. Chem., 65
- Erney, 1993, Explanation of the matrix-induced chromatographic response enhancement of organophosphorus pesticides during open tubular column gas chromatography with splitless or hot on-column injection and flame photometric detection, J. Chromatogr., A, 638, 57, 10.1016/0021-9673(93)85007-T · DOI · Paper page
- Bonfiglio, 1999, The effects of sample preparation methods on the variability of the electrospray ionization response for model drug compounds, Rapid Commun. Mass Spectrom., 13, 1175, 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO;2-0 · DOI · Paper page
- Buhrman, 1996, Quantitation of SR 27417 in human plasma using electrospray liquid chromatography-tandem mass spectrometry: a study of ion suppression, J. Am. Soc. Mass Spectrom., 7, 1099, 10.1016/S1044-0305(96)00072-4 · DOI · Paper page
- Chambers, 2007, Systematic and comprehensive strategy for reducing matrix effects in LC/MS/MS analyses, J. Chromatogr., B Anal. Technol. Biomed. Life Sci., 852, 22, 10.1016/j.jchromb.2006.12.030 · DOI · Paper page
- Kwon, 2012, Variability of matrix effects in liquid and gas chromatography-mass spectrometry analysis of pesticide residues after QuEChERS sample preparation of different food crops, J. Chromatogr., A, 1270, 235, 10.1016/j.chroma.2012.10.059 · DOI · Paper page
- Ferrer Amate, 2010, Development and validation of a LC-MS/MS method for the simultaneous determination of aflatoxins, dyes and pesticides in spices, Anal. Bioanal. Chem., 397, 93, 10.1007/s00216-010-3526-x · DOI
- Ferrer, 2011, Overcoming matrix effects using the dilution approach in multiresidue methods for fruits and vegetables, J. Chromatogr., A, 1218, 7634, 10.1016/j.chroma.2011.07.033 · DOI · Paper page
- Matuszewski, 2006, Standard line slopes as a measure of a relative matrix effect in quantitative HPLC-MS bioanalysis, J. Chromatogr., B Anal. Technol. Biomed. Life Sci., 830, 293, 10.1016/j.jchromb.2005.11.009 · doi:10.1016/j.jchromb.2005.11.009
- Viswanathan, 2007, Quantitative bioanalytical methods validation and implementation: best practices for chromatographic and ligand binding assays, Pharm. Res., 24, 1962, 10.1007/s11095-007-9291-7 · DOI · Paper page
- Malachová, 2014, Optimization and validation of a quantitative liquid chromatography-tandem mass spectrometric method covering 295 bacterial and fungal metabolites including all regulated mycotoxins in four model food matrices, J. Chromatogr., A, 1362, 145, 10.1016/j.chroma.2014.08.037 · DOI · Paper page
- Steiner, 2020, Evaluation of matrix effects and extraction efficiencies of LC-MS/MS methods as the essential part for proper validation of multiclass contaminants in complex feed, J. Agric. Food Chem., 68, 3868, 10.1021/acs.jafc.9b07706 · DOI · Paper page
- Cappiello, 2008, Overcoming matrix effects in liquid chromatography-mass spectrometry, Anal. Chem., 80, 9343, 10.1021/ac8018312 · DOI · Paper page
- Adamowicz, 2016, Simple approach for evaluation of matrix effect in the mass spectrometry of synthetic cannabinoids, J. Anal. Chem., 71, 794, 10.1134/S1061934816080025 · doi:10.1134/s1061934816080025
- Kruve, 2013, Comparison of different methods aiming to account for/overcome matrix effects in LC/ESI/MS on the example of pesticide analyses, Anal. Methods., 5, 3035, 10.1039/c3ay26551j · doi:10.1039/c3ay26551j
- Trufelli, 2011, An overview of matrix effects in liquid chromatography-mass spectrometry, Mass Spectrom. Rev., 30, 491, 10.1002/mas.20298 · DOI · Paper page
- Niessen, 2006, Matrix effects in quantitative pesticide analysis using liquid chromatography-mass spectrometry, Mass Spectrom. Rev., 25, 881, 10.1002/mas.20097 · DOI · Paper page
- Kang, 2007, Using calibration approaches to compensate for remaining matrix effects in quantitative liquid chromatography/electrospray ionization multistage mass spectrometric analysis of phytoestrogens in aqueous environmental samples, Rapid Commun. Mass Spectrom., 21, 4065, 10.1002/rcm.3311 · DOI
- Antignac, 2005, The ion suppression phenomenon in liquid chromatography-mass spectrometry and its consequences in the field of residue analysis, Anal. Chim. Acta, 529, 129, 10.1016/j.aca.2004.08.055 · DOI
- Rutkowska, 2020, Compensation of matrix effects in seed matrices followed by gas chromatography-tandem mass spectrometry analysis of pesticide residues, J. Chromatogr., A, 1614, 10.1016/j.chroma.2019.460738 · DOI
- Maštovská, 2005, Combination of analyte protectants to overcome matrix effects in routine GC analysis of pesticide residues in food matrixes, Anal. Chem., 77, 8129, 10.1021/ac0515576 · DOI · Paper page
- Mallet, 2004, A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts, Rapid Commun. Mass Spectrom., 18, 49, 10.1002/rcm.1276 · DOI · Paper page
- Schuhmacher, 2003, Matrix effects during analysis of plasma samples by electrospray and atmospheric pressure chemical ionization mass spectrometry: practical approaches to their elimination, Rapid Commun. Mass Spectrom., 17, 1950, 10.1002/rcm.1139 · doi:10.1002/rcm.1139
- Stahnke, 2012, Reduction of matrix effects in liquid chromatography-electrospray ionization-mass spectrometry by dilution of the sample extracts: how much dilution is needed?, Anal. Chem., 84, 1474, 10.1021/ac202661j · DOI · Paper page
- Li, 2016, Reduction of matrix effects through a simplified QuEChERS method and using small injection volumes in a LC-MS/MS system for the determination of 28 pesticides in fruits and vegetables, Anal. Methods., 8, 5061, 10.1039/C6AY00080K · doi:10.1039/c6ay00080k
- Stüber, 2004, Evaluation of three calibration methods to compensate matrix effects in environmental analysis with LC-ESI-MS, Anal. Bioanal. Chem., 378, 910, 10.1007/s00216-003-2442-8 · doi:10.1007/s00216-003-2442-8
- Rimayi, 2015, Alternative calibration techniques for counteracting the matrix effects in GC-MS-SPE pesticide residue analysis - a statistical approach, Chemosphere, 118, 35, 10.1016/j.chemosphere.2014.05.075 · doi:10.1016/j.chemosphere.2014.05.075
- Benijts, 2004, Countering matrix effects in environmental liquid chromatography- electrospray ionization tandem mass spectrometry water analysis for endocrine disrupting chemicals, J. Chromatogr., A, 1029, 153, 10.1016/j.chroma.2003.12.022 · DOI · Paper page
- Van Eeckhaut, 2009, Validation of bioanalytical LC-MS/MS assays: evaluation of matrix effects, J. Chromatogr., B Anal. Technol. Biomed. Life Sci., 877, 2198, 10.1016/j.jchromb.2009.01.003 · DOI · Paper page
- Hewavitharana, 2018, Standard addition with internal standardisation as an alternative to using stable isotope labelled internal standards to correct for matrix effects—comparison and validation using liquid chromatography-tandem mass spectrometric assay of vitamin D, J. Chromatogr., A, 1553, 101, 10.1016/j.chroma.2018.04.026 · doi:10.1016/j.chroma.2018.04.026
- Stokvis, 2005, Stable isotopically labeled internal standards in quantitative bioanalysis using liquid chromatography/mass spectrometry: necessity or not?, Rapid Commun. Mass Spectrom., 19, 401, 10.1002/rcm.1790 · DOI · Paper page
- Wang, 2007, Does a stable isotopically labeled internal standard always correct analyte response?. A matrix effect study on a LC/MS/MS method for the determination of carvedilol enantiomers in human plasma, J. Pharmaceut. Biomed. Anal., 43, 701, 10.1016/j.jpba.2006.08.010 · DOI · Paper page
- Poole, 2007, Matrix-induced response enhancement in pesticide residue analysis by gas chromatography, J. Chromatogr., A, 1158, 241, 10.1016/j.chroma.2007.01.018 · DOI · Paper page
- Kollipara, 2011, International guidelines for bioanalytical method validation: a comparison and discussion on current scenario, Chromatographia, 73, 201, 10.1007/s10337-010-1869-2 · DOI
- González, 2014, Bioanalytical chromatographic method validation according to current regulations, with a special focus on the non-well defined parameters limit of quantification, robustness and matrix effect, J. Chromatogr., A, 1353, 10, 10.1016/j.chroma.2014.03.077 · DOI · Paper page
- Kadian, 2016, Comparative assessment of bioanalytical method validation guidelines for pharmaceutical industry, J. Pharmaceut. Biomed. Anal., 126, 83, 10.1016/j.jpba.2016.03.052 · DOI · Paper page
- 2003, Guide for validation of analytical and bioanalytical methods, Resolution - RE n. 899
- Commission Decision of European Union, 2002, The performance of analytical methods and the interpretation of results, Off. J. Eur. Communities, 221, 8
- Thompson, 2002, Harmonized guidelines for single-laboratory validation of methods of analysis, Pure Appl. Chem., 74, 835, 10.1351/pac200274050835 · DOI · Paper page
- 2013, Report from the scientific working group for forensic toxicology. Standard practices for method validation in forensic toxicology, J. Anal. Toxicol., 37, 452, 10.1093/jat/bkt054 · DOI · Paper page
Cited by
Yang, H., Li, J., Mao, J., Xu, C., Song, J., & Xie, F. (2023) · Molecules · doi:10.3390/molecules28227634 · Cited by 13
“Information on samples with detectable results was summarized in Table 3.”
BackgroundAlahmadi, S. M., & Abu-Dief, A. M. (2026) · Sustainable Chemistry · doi:10.3390/suschem7030033 · Cited by 1
“In many untargeted analytical studies, particularly those involving trace-level compounds in complex matrices, sample preparation represents the most time-consuming and challenging stage and strongly influences both the accuracy and overall duration of the analytical workflow [2,3].”
Metadata
- Authors
- Raposo, F., & Barceló, D.
- Venue
- TrAC Trends in Analytical Chemistry
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 134
- Pages
- 116068
- ISSN
- 0165-9936 (ISSN-L)
- OpenAlex
- W3092136049
- Cited by
- 217
- References
- 1
- FWCI
- 8.16
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Challenges and strategies of matrix effects using chromatography-mass spectrometry: An overview from research versus regulatory viewpoints. https://app.cochat.ai/papers/10.1016/j.trac.2020.116068
- The paper
- Raposo, F., & Barceló, D. (2021). Challenges and strategies of matrix effects using chromatography-mass spectrometry: An overview from research versus regulatory viewpoints. TrAC Trends in Analytical Chemistry. https://doi.org/10.1016/j.trac.2020.116068
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.