Real-time multi-channel stimulus artifact suppression by local curve fitting
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gray, C. M., Maldonado, P. E., Wilson, M., & McNaughton, B. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00085-2 · Cited by 742 · cited 1×
“Micro-electrode arrays (MEAs) (Thomas et al., 1972; Gross, 1979; Pine, 1980) and related technologies such as tetrode probes (Gray et al., 1995), silicon probes (Bai and Wise, 2001) and multi-wire probes (Nicolelis et al., 1998) offer great promise to record action potentials extracellularly from a…”
BackgroundA miniature microelectrode array to monitor the bioelectric activity of cultured cells
THOMASJR, C., SPRINGER, P., LOEB, G., BERWALDNETTER, Y., & OKUN, L. (1972) · Experimental Cell Research · doi:10.1016/0014-4827(72)90481-8 · Cited by 580 · cited 1×
“Micro-electrode arrays (MEAs) (Thomas et al., 1972; Gross, 1979; Pine, 1980) and related technologies such as tetrode probes (Gray et al., 1995), silicon probes (Bai and Wise, 2001) and multi-wire probes (Nicolelis et al., 1998) offer great promise to record action potentials extracellularly from a…”
BackgroundRecording action potentials from cultured neurons with extracellular microcircuit electrodes
Pine, J. (1980) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(80)90042-4 · Cited by 543 · cited 1×
“Micro-electrode arrays (MEAs) (Thomas et al., 1972; Gross, 1979; Pine, 1980) and related technologies such as tetrode probes (Gray et al., 1995), silicon probes (Bai and Wise, 2001) and multi-wire probes (Nicolelis et al., 1998) offer great promise to record action potentials extracellularly from a…”
BackgroundA new approach to neural cell culture for long-term studies
Potter, S. M., & DeMarse, T. B. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00412-5 · Cited by 489 · cited 4×
“A 15 l droplet of neurobasal medium containing 50,000 cells was applied to the electrode area, and the dishes were sealed with FEP Teflon R lids (Potter and DeMarse 2001).”
MethodInfluentialSelf-citationCortical area MT and the perception of stereoscopic depth
DeAngelis, G. C., Cumming, B. G., & Newsome, W. T. (1998) · Nature · doi:10.1038/29299 · Cited by 424 · cited 1×
“Simultaneously stimulating and recording through a single MEA is attractive for the study of input-output relationships (Novak and Wheeler, 1988; DeAngelis et al., 1998), but poses technical difficulties because the stimuli employed are often four or five orders of magnitude greater than…”
BackgroundLocal Regression: Automatic Kernel Carpentry
Hastie, T., & Loader, C. (1993) · Statistical Science · doi:10.1214/ss/1177011002 · Cited by 415 · cited 1×
“SALPA works by locally fitting (Hastie and Loader, 1993) a function to the recorded trace that has enough degrees of freedom to accurately model the artifact, but not enough to represent individual action potentials. By subtracting this fitted function from the recording, the artifact-free signal remains, and action p…”
Multi-neuronal signals from the retina: acquisition and analysis
Meister, M., Pine, J., & Baylor, D. A. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90030-2 · Cited by 411 · cited 1×
“…1995), silicon probes (Bai and Wise, 2001) and multi-wire probes (Nicolelis et al., 1998) offer great promise to record action potentials extracellularly from a large number of cells simultaneously (Meister et al., 1994; Potter, 2001), in cell culture, in slice or in vivo (Bragin et al., 2000).”
BackgroundJimbo, Y., Tateno, T., & Robinson, H. P. C. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77234-6 · Cited by 396 · cited 6×
“In addition, electrical stimulation through such arrays has been reported in a wide variety of preparations, such as murine spinal cord (Gross et al., 1993), rat cortex (Jimbo et al., 1999), cat sciatic nerve (Branner and Normann, 2000) and rabbit retina (Grumet et al., 2000).”
BackgroundInfluentialMaeda, E., Robinson, H., & Kawana, A. (1995) · The Journal of Neuroscience · doi:10.1523/jneurosci.15-10-06834.1995 · Cited by 365 · cited 1×
“The non-linear behavior of saturated amplifiers, together with the properties of the filters used for noise reduction, make this artifact last much longer than the stimulus that caused it, sometimes up to 100 ms (Maeda et al., 1995), even on channels not used for stimulation.”
BackgroundGross, G. W. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326402 · Cited by 324
Cited by
An extremely rich repertoire of bursting patterns during the development of cortical cultures
Wagenaar, D. A., Pine, J., & Potter, S. M. (2006) · BMC Neuroscience · doi:10.1186/1471-2202-7-11 · Cited by 791
Self-citationRevealing neuronal function through microelectrode array recordings
Obien, M. E. J., Deligkaris, K., Bullmann, T., Bakkum, D. J., & Frey, U. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00423 · Cited by 705
“The transmission of data may also affect the quality of the recorded signal, e.g., if a lossy compression has to be used due to bandwidth constraints.”
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Controlling Bursting in Cortical Cultures with Closed-Loop Multi-Electrode Stimulation
Wagenaar, D. A., Madhavan, R., Pine, J., & Potter, S. M. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.4209-04.2005 · Cited by 452
Self-citationElectrical Stimulation of Mammalian Retinal Ganglion Cells With Multielectrode Arrays
Sekirnjak, C., Hottowy, P., Sher, A., Dabrowski, W., Litke, A. M., & Chichilnisky, E. J. (2006) · Journal of Neurophysiology · doi:10.1152/jn.01168.2005 · Cited by 337
Effective parameters for stimulation of dissociated cultures using multi-electrode arrays
Wagenaar, D. A., Pine, J., & Potter, S. M. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2004.03.005 · Cited by 304
Self-citationShape perception via a high-channel-count neuroprosthesis in monkey visual cortex
Chen, X., Wang, F., Fernandez, E., & Roelfsema, P. R. (2020) · Science · doi:10.1126/science.abd7435 · Cited by 250
Kozai, T. D. Y., Catt, K., Li, X., Gugel, Z. V., Olafsson, V. T., Vazquez, A. L., & Cui, X. T. (2015) · Biomaterials · doi:10.1016/j.biomaterials.2014.10.040 · Cited by 218
Chronic In Vivo Evaluation of PEDOT/CNT for Stable Neural Recordings
Kozai, T. D. Y., Catt, K., Du, Z., Na, K., Srivannavit, O., Haque, R.-U. M., Seymour, J., Wise, K. D., Yoon, E., & Cui, X. T. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2445713 · Cited by 197
“The spike data stream was further preprocessed using published methods [29], [30].”
MethodKozai, T. D. Y., Li, X., Bodily, L. M., Caparosa, E. M., Zenonos, G. A., Carlisle, D. L., Friedlander, R. M., & Cui, X. T. (2014) · Biomaterials · doi:10.1016/j.biomaterials.2014.08.006 · Cited by 136
Toward true closed-loop neuromodulation: artifact-free recording during stimulation.
Zhou, A., Johnson, B. C., & Muller, R. (2018) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2018.01.012 · Cited by 125
A system for neural recording and closed-loop intracortical microstimulation in awake rodents.
Venkatraman, S., Elkabany, K., Long, J. D., Yao, Y., & Carmena, J. M. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2005944 · Cited by 96
“Software reduction of the artifact is possible to some extent [ 29 ], but software techniques can never recover the period during which the amplifiers are saturated and this period is often longer than 5 ms. Hardware-based techniques reported previously include using a low-slew-rate initial amplifier [30] or actively…”
MethodStimulus-artifact elimination in a multi-electrode system.
Brown, E. A., Ross, J. D., Blum, R. A., Nam, Y., Wheeler, B. C., & DeWeerth, S. P. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.918285 · Cited by 95
Generalized framework for stimulus artifact removal.
Erez, Y., Tischler, H., Moran, A., & Bar-Gad, I. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.06.005 · Cited by 79
An integrated system for simultaneous, multichannel neuronal stimulation and recording.
Blum, R. A., Ross, J. D., Brown, E. A., & DeWeerth, S. P. (2007) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2007.906071 · Cited by 74
Hottowy, P., Skoczeń, A., Gunning, D. E., Kachiguine, S., Mathieson, K., Sher, A., Wiącek, P., Litke, A. M., & Dąbrowski, W. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/066005 · Cited by 67
Computational challenges and opportunities for a bi-directional artificial retina
Shah, N. P., & Chichilnisky, E. J. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba8b1 · Cited by 39
“Hence, automation of this step is important, but it is challenging (Hashimoto et al 2002, Wagenaar and Potter 2002, Heffer and Fallon 2008, Erez et al 2010).”
Toward a personalized closed-loop stimulation of the visual cortex: Advances and challenges
Grani, F., Soto-Sánchez, C., Fimia, A., & Fernández, E. (2022) · Frontiers in Cellular Neuroscience · doi:10.3389/fncel.2022.1034270 · Cited by 16
“Different signal processing techniques and electronic front-end designs can be used to retrieve the signals from stimulation artifacts (Wagenaar and Potter, 2002; Zhou et al., 2018) but these techniques do not work when the amplifiers are saturated.”
MethodHigh-frequency electrical stimulation of cardiac cells and application to artifact reduction.
Dura, B., Chen, M. Q., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188136 · Cited by 15
“ing circuits [31], complex charge balancing electronics [32], and signal processing (linear and nonlinear filtering, template subtraction) [33]–[35].”
BackgroundThe University of Tokyo, J., Masumori, A., Maruyama, N., Sinapayen, L., Mita, T., Frey, U., Bakkum, D., Takahashi, H., & Ikegami, T. (2015) · 07/20/2015-07/24/2015 · doi:10.7551/978-0-262-33027-5-ch067 · Cited by 14
“The Salpa filter in MEABench was used to remove the artifact in real time (Wagenaar and Potter (2002)).”
Equalization for intracortical microstimulation artifact reduction.
Chu, P., Muller, R., Koralek, A., Carmena, J. M., Rabaey, J. M., & Gambini, S. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609483 · Cited by 13
“In [6], artifacts are removed in post-processing by fitting a function to model the artifact and subtracting it from the signal.”
MethodWhen the ostrich-algorithm fails: blanking method affects spike train statistics.
Joseph, K., Mottaghi, S., Christ, O., Feuerstein, T. J., & Hofmann, U. G. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00293 · Cited by 3
“The overlapping artifact may render the acquired neuronal signal difficult to analyze, which can be debilitating when neuronal spike statistics or responses are the focus of the investigation (Wagenaar and Potter, 2002).”
Background
Metadata
- Authors
- Wagenaar, D. A., & Potter, S. M.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2002-10
- Volume
- 120
- Issue
- 2
- Pages
- 113-120
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2110284997
- Cited by
- 227
- References
- 25
- FWCI
- 1.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.