Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
The DOI matches its Crossref record; 28 of the 31 references it cites were found in a registry or an index.
Abstract
The Utah Intracortical Electrode Array (UIEA) is an array of 100 penetrating silicon microelectrodes designed to focally electrically stimulate or record neurons residing in a single layer up to 1.5 mm beneath the surface of the cerebral cortex. Apart from its use as a unique tool to study parallel processing in the central nervous system, this array could form the platform for a cortical neuroprosthetic system. Although the UIEA has been used extensively in acute neural recording and stimulation experiments, its long-term performance in a chronic application has yet to be demonstrated. As an initial investigation into the feasibility of long-term cortical recording with an array of microelectrodes, we have hard-wired a subset of 11 electrodes of the UIEA to a percutaneous connector. This chronic UIEA assembly was then implanted into the cerebral cortices of ten cats for durations ranging from 2 to 13 months; over which time, both random and stimulus-evoked single and multiple unit action potentials were periodically recorded. On average, after a 6-month implant period, 60% of implanted arrays could still record some type of activity. Post-sacrifice dissections revealed a fibrous encapsulation of the UIEA. Although most implanted cortex was histologically normal, evidence of a chronic astroglial response was seen in a few cases. The results of the reported experiments indicate that the UIEA can be successfully used for limited times in a chronic recording application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional BMIs with probe-like morphology for LFP recordings are generally small and rigid.[338]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [338]
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationRepresentation of cochlea within primary auditory cortex in the cat
Merzenich, M. M., Knight, P. L., & Roth, G. L. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.231 · Cited by 637
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationA method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationA driveable bundle of microwires for collecting single-unit data from freely-moving rats
Kubie, J. L. (1984) · Physiology & Behavior · doi:10.1016/0031-9384(84)90080-5 · Cited by 184
Research works printed but not linked: 2
- DeYoe EA. An Investigation in the Awake Macaque of the Threshold for Detection of Electrical Currents Applied to Striate Cortex: Psychophysical Properties and Laminar Differences. Ph.D. Thesis, University of Rochester, 1983.
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
Cited by
Items 401–500 of 662
Qiao, S., Odoemene, O., & Yoshida, K. (2012) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-012-0930-8 · Cited by 14
“Examining the similarity of spike waveform shape [13, 24, 27] combined with tracking interspike interval [5, 9] has been commonly used for the assessment of the chronic stability of singleunit recordings.”
BackgroundMethodA WIRELESS MULTICHANNEL NEURAL RECORDING PLATFORM FOR REAL-TIME BRAIN MACHINE INTERFACES
Obeid, I. (2004) · Cited by 20
Du, M., Xu, X., Yang, L., Guo, Y., Guan, S., Shi, J., Wang, J., & Fang, Y. Z. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.01.027 · Cited by 13
Layer-dependent stability of intracortical recordings and neuronal cell loss
Urdaneta, M. E., Kunigk, N. G., Peñaloza-Aponte, J., Currlin, S., Malone, I. G., Fried, S. I., & Otto, K. J. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1096097 · Cited by 12
“Typically, electrodes are implanted perpendicular to the cortical surface and sit within one or multiple columns depending on the size and orientation of the implant (Rousche and Normann, 1998).”
BackgroundMethodInfluentialHorváth, C., Csikós, K., Árkossy, B., Klein, E., Ruther, P., Ulbert, I., & Fiáth, R. (2024) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2024.136220 · Cited by 13
Yamashita, K., Sawahata, H., Yamagiwa, S., Yokoyama, S., Numano, R., Koida, K., & Kawano, T. (2022) · Lab on a Chip · doi:10.1039/d1lc01031j · Cited by 13
Kim, J.-H., Baek, D.-H., Kim, D. H., & Park, D. (2022) · Current Applied Physics · doi:10.1016/j.cap.2022.05.001 · Cited by 13
Insertion of a three dimensional silicon microelectrode assembly through a thick meningeal membrane
Escamilla-Mackert, T., Langhals, N. B., Kozai, T. D. Y., & Kipke, D. R. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5333221 · Cited by 12
“limitations and optimize insertion techniques for implantable 3D arrays [4-7].”
MethodA polymer based electrode array for recordings in the cerebellum
Ejserholm, F., Kohler, P., Bengtsson, M., Jörntell, H., Schouenborg, J., & Wallman, L. (2011) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2011.5910565 · Cited by 12
“Electrode arrays available today can contain up to a hundred electrodes as well as being stable for over a year [ 2 ].”
BackgroundKim, J. H., Song, I., Lee, S. M., Choi, H., Byeon, H., Kim, I. Y., & Lee, S. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2263226 · Cited by 13
Patrick, E. E., Sankar, V., Rowe, W., Yen, S.-F., Sanchez, J. C., & Nishida, T. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649874 · Cited by 14
“This value is characteristic of small surface area electrodes and is on the same order of magnitude as electrodes in the Utah array [8].”
Bouton, C. E. (2019) · Cold Spring Harbor Perspectives in Medicine · doi:10.1101/cshperspect.a034306 · Cited by 12
Nabai, L., Ghahary, A., & Jackson, J. K. (2022) · Pharmaceutics · doi:10.3390/pharmaceutics14081546 · Cited by 11
Wafer Level Processing of Silicon Arrays for Implantable Medical Devices
Bhandari, R., Negi, S., Rieth, L. W., Topper, M. J., Normann, R. A., & Solzbacher, F. (2007) · IEEE Electronic Components and Technology Conference (ECTC) · doi:10.1109/ectc.2007.374004 · Cited by 11
Self-citationPenetrating microelectrode arrays with low-impedance sputtered iridium oxide electrode coatings
Cogan, S. F., Ehrlich, J., Plante, T. D., & Wagenen, R. V. (2009) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2009.5335359 · Cited by 12
Electrical and Physical Sensors for Biomedical Implants
Kassanos, P., Anastasova, S., & Yang, G. (2018) · Springer eBooks · doi:10.1007/978-3-319-69748-2_3 · Cited by 15
Solarana, K., Ye, M., Gao, Y., Rafi, H., & Hammer, D. X. (2020) · Neurophotonics · doi:10.1117/1.nph.7.1.015004 · Cited by 11
“A recent macaque study reported that over half of implanted arrays failed within the first year of implantation,(12) and multiple others have reported a progressive decline in spike amplitudes, functional channels, and detectable single units.(10,13) Biological responses, including BBB disruption, astrocytic and micro…”
BackgroundMaterial–tissue interfaces in implantable systems
Stieglitz, T., & Schüettler, M. (2013) · Elsevier eBooks · doi:10.1533/9780857096289.1.39 · Cited by 12
Baghmanli, Z., Sugg, K. B., Wei, B. P. C., Shim, B. S., Martin, D. C., Cederna, P. S., & Urbanchek, M. G. (2013) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3182959f63 · Cited by 14
Hascup, E. R., Hascup, K. N., Talauliker, P. M., Price, D. A., Pomerleau, F., Quintero, J. E., Huettl, P. F., Gratton, A. P., Strömberg, I., & Gerhardt, G. A. (2013) · Neuromethods · doi:10.1007/978-1-62703-370-1_8 · Cited by 11
Bjånes, D. A., Bashford, L., Pejsa, K., Lee, B., Liu, C. Y., & Andersen, R. A. (2022) · medRxiv · doi:10.1101/2022.08.08.22278389 · Cited by 12
“Two SIROF tipped 48-channel Utah arrays [75] were placed in primary sensory cortex (S1), targeting the hand and arm region [3].”
MethodIn the realm of hybrid Brain: Human Brain and AIPreprint
Fares, H., Ronchini, M., Zamani, M., Farkhani, H., & Moradi, F. (2022) · arXiv (Cornell University) · doi:10.48550/arxiv.2210.01461 · Cited by 13
“To overcome these limitations, silicon-based needle shaped microelectrodes enabling multisite recording were proposed [81]–[83] .”
BackgroundBjånes, D. A., Bashford, L., Pejsa, K., Lee, B., Liu, C. Y., & Andersen, R. A. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae1bd8 · Cited by 10
“A human participant with C5 level spinal cord injury was consented and chronically implanted with Neuroport ‘Utah’ arrays (Blackrock Neurotech, Inc) [48, 49].”
Spatially Controlling Neuronal Adhesion and Inflammatory Reactions on Implantable Diamond
Regan, E. M., Taylor, A. C., Uney, J. B., Dick, A. D., May, P. W., & McGeehan, J. P. (2011) · IEEE Journal on Emerging and Selected Topics in Circuits and Systems · doi:10.1109/jetcas.2011.2174469 · Cited by 14
Long-term in-vivo recording performance of flexible penetrating microelectrode arrays
Jang, J., Kang, Y. N., Seo, H. W., Kim, B., Choe, H. K., Park, S. H., Lee, M., & Kim, S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3656 · Cited by 10
“Research group Jang et al (current study) Black et al [46] Joshi-Imre et al [47] Rousche et al [48] Colachis et al [49]”
BackgroundSlippery Epidural ECoG Electrode for High-Performance Neural Recording and Interface
Alahi, M. E. E., Liu, Y., Khademi, S., Nag, A., Wang, H., Wu, T., & Mukhopadhyay, S. C. (2022) · Biosensors · doi:10.3390/bios12111044 · Cited by 10
“Secondly, the glial scar can increase the electrode’s impedance and reduce the SNR, positively correlated with the noise [21,22].”
BackgroundHarris, A. R., Morgan, S. J., Wallace, G. G., & Paolini, A. G. (2014) · Journal of Visualized Experiments · doi:10.3791/51084 · Cited by 11
Takemi, M., Castagnola, E., Ansaldo, A., Ricci, D., Fadiga, L., Taoka, M., Iriki, A., & Ushiba, J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00580 · Cited by 12
Huang, S.-H., Shmoel, N., Jankowski, M. M., Erez, H., Sharon, A., Abu-Salah, W., Nelken, I., Weiss, A. M., & Spira, M. E. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00926 · Cited by 12
Harris, A. R. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abd897 · Cited by 10
Comprehensive characterization of tungsten microwires in chronic neurocortical implants
Prasad, A., Xue, Q., Sankar, V., Nishida, T., Shaw, G., Streit, W. J., & Sanchez, J. C. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346041 · Cited by 10
“The development of high-density microelectrode probes [4-6] has enabled the recording of signals from large neuronal ensembles however the current systems have been unable to access such signals for more than several years [5].”
BackgroundAn acute method for multielectrode recording from the interior of sulci and other deep brain areas
Purushothaman, G., Scott, B. B., & Bradley, D. C. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.10.015 · Cited by 10
Wolf, M. T. (2008) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/6y3f-8m87 · Cited by 10
Electrodes and instrumentation for neurostimulation
Merrill, D. R. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00002-2 · Cited by 11
Opie, N. L., Ayton, L. N., Apollo, N. V., Ganesan, K., Guymer, R. H., & Luu, C. D. (2014) · Artificial Organs · doi:10.1111/aor.12287 · Cited by 9
Ha, J.-G., Lee, S.-K., Bai, S. J., Kim, Y.-K., & Park, J. (2013) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/23/11/115009 · Cited by 9
Brain Function: Novel Technologies Driving Novel Understanding
Assad, J. A., Berdondini, L., Cancedda, L., Angelis, F. D., Diaspro, A., Dipalo, M., Fellin, T., Maccione, A., Panzeri, S., & Sileo, L. (2014) · Springer eBooks · doi:10.1007/978-3-319-04924-3_10 · Cited by 11
“2009) or “out-of-plane” processing from a single block of silicon, using etching, doping, and heat treatments to realize a three-dimensional array of “needlelike” electrodes (Maynard et al. 1997; Rousche and Normann 1998; Nordhausen et al. 1994).”
BackgroundHarris, A. R., Hutchinson, R., Molino, P. J., Kapsa, R. M. I., Clark, G. M., Paolini, A. G., & Wallace, G. G. (2016) · Journal of The Electrochemical Society · doi:10.1149/2.0711607jes · Cited by 9
Harris, A. R., Newbold, C., Cowan, R., & Wallace, G. G. (2019) · Journal of The Electrochemical Society · doi:10.1149/2.1361910jes · Cited by 9
Neural Interface Dynamics Following Insertion of Hydrous Iridium Oxide Microelectrode Arrays
Johnson, M. D., Langhals, N. B., & Kipke, D. R. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260521 · Cited by 9
An imaging system for monitoring receptive field dynamics
Petersson, P., Holmer, M., Breslin, T., Granmo, M., & Schouenborg, J. (2001) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00332-0 · Cited by 9
Designing a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A., Morizio, J., Chapin, J. K., Nicolelis, M. A. L., & Wolf, P. (2000) · Frontiers in neuroscience · doi:10.1201/9781420039054.pt2 · Cited by 11
Ikegaya, N., Mallela, A. N., Warnke, P. C., Kunigk, N. G., Liu, F., Schone, H. R., Verbaarschot, C., Hatsopoulos, N. G., Downey, J. E., Boninger, M. L., et al. (2024) · Journal of neurosurgery · doi:10.3171/2024.7.jns241296 · Cited by 10
Neuroelectrophysiology-compatible electrolytic lesioning
Bray, I. E., Clarke, S. E., Casey, K. M., & Nuyujukian, P. (2024) · eLife · doi:10.7554/elife.84385 · Cited by 10
Progress in Mechanical Modeling of Implantable Flexible Neural Probes
You, X., Bai, R., Xue, K., Zhang, Z., Wang, M., Wang, X., Wang, J., Guo, J., Shen, Q., Chang, H., et al. (2024) · Computer Modeling in Engineering & Sciences · doi:10.32604/cmes.2024.049047 · Cited by 11
Intact Histological Characterization of Brain-implanted Microdevices and Surrounding Tissue
Woolley, A. J., Desai, H. A., Gaire, J., Ready, A. L., & Otto, K. J. (2013) · Journal of Visualized Experiments · doi:10.3791/50126-v · Cited by 8
Intracortical Hindlimb Brain–Computer Interface Systems: A Systematic Review
Ghodrati, M. T., Mirfathollahi, A., Shalchyan, V., & Daliri, M. R. (2023) · IEEE Access · doi:10.1109/access.2023.3258969 · Cited by 9
“the axon output near the recording electrode [83]; except”
BackgroundDouble‐Sided, Thin‐Film Microelectrode Array with Hemispheric Electrodes for Subretinal Stimulation
Kim, N., Hong, Y., Cha, S., Kang, Y. N., Seo, H. W., Moon, H., Ahn, J., Intisar, A., Kim, M. S., Kim, S., et al. (2024) · Advanced Materials Technologies · doi:10.1002/admt.202302155 · Cited by 8
Zhou, R., Jiang, N., Englehart, K. B., & Parker, P. A. (2009) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-009-0555-8 · Cited by 8
“(1) the shapes of recorded action potentials (APs) are time invariant [13]; (2) the detectable nerve fibers are within 12 lm of the recording electrodes [13, 25 ]; (3) the amplitudes of nerve fiber APs are inversely proportional to their distances from the electrode; and”
BackgroundMethodInfluential7.32 Engineering the Neural Interface
Kelly, A., Ballerini, L., Lowery, M. M., & Biggs, M. J. P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-803581-8.09322-x · Cited by 10
Cryogel‐Based Electronic–Tissue Interfaces with Soft, Highly Compressible, and Tunable Mechanics
Ghatee, R., Tolouei, A. E., Fijalkowski, J., Alsasa, A., Hayes, J., Besio, W. G., & Kennedy, S. M. (2019) · Macromolecular Materials and Engineering · doi:10.1002/mame.201900367 · Cited by 8
3C-SiC on Si: A Versatile Material for Electronic, Biomedical and Clean Energy Applications
Frewin, C. L., Reyes, M., Register, J., Thomas, S. W., & Saddow, S. E. (2014) · MRS Proceedings · doi:10.1557/opl.2014.567 · Cited by 8
Tresco, P. A., & Gerhardt, G. A. (2008) · Springer eBooks · doi:10.1007/978-1-4020-8705-9_3 · Cited by 8
“Indeed, one can find discussions in the peer-reviewed literature that draw attention to performance problems with chronic recording electrode arrays where typically the number of functional recording sites and the quality of signals observed diminish over time (Burns et al., 1974; Liu et al., 1999; Ludwig et al., 2006…”
BackgroundSpencer, K. C., Sy, J. C., Ramadi, K. B., Graybiel, A. M., Langer, R., & Cima, M. J. (2017) · Scientific Reports · doi:10.1038/s41598-017-12312-8 · Cited by 8
A Fully Adapted Headstage With Custom Electrode Arrays Designed for Electrophysiological Experiments
Mourão, F. A. G., Guarnieri, L. D. O., Júnior, P. A. A., Carvalho, V. R., Mendes, E. M. A. M., & Moraes, M. F. D. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.691788 · Cited by 8
“, 1983) or silicon (Jones et al., 1992; Rousche and Normann, 1998; Buzsáki et al., 2015; Jun et al., 2017) a wide range of electrodes with different sizes, shapes, and geometries, has been used to sample brain activity.”
BackgroundModeling in vitro neural electrode interface in neural cell culture medium
Sun, T., Tsang, W. M., Park, W., Cheng, K., & Merugu, S. (2014) · Microsystem Technologies · doi:10.1007/s00542-014-2292-7 · Cited by 7
Robust Induced Presynapse on Artificial Substrates as a Neural Interfacing Method
Jeon, J., Oh, M., Cho, W., Yoon, S.-H., Kim, J. Y., & Chung, T. D. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.8b20405 · Cited by 7
Silicon-based wire electrode array for neural interfaces
Pei, W., Zhao, H., Zhao, S., Fang, X., Chen, S., Gui, Q., Tang, R., Chen, Y., Hong, B., Gao, X., et al. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/9/095015 · Cited by 8
Prospects for a Robust Cortical Recording Interface
Shoffstall, A. J., & Capadona, J. R. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00028-0 · Cited by 8
Mehrabbeik, M., Shams-Ahmar, M., Levine, A. T., Jafari, S., & Merrikhi, Y. (2022) · Chaos Solitons & Fractals · doi:10.1016/j.chaos.2022.112051 · Cited by 7
Recording cerebellar neuron activities in swimming goldfish
MATSUMOTO, N., Yoshida, M., & Uematsu, K. (2007) · Fisheries Science · doi:10.1111/j.1444-2906.2007.01363.x · Cited by 7
In Situ Measurement of Stimulus Induced pH Changes Using ThinFilm Embedded IrOx pH Electrodes
Pfau, J., Ordonez, J. A. L., & Stieglitz, T. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8513441 · Cited by 7
“technology of multi-channel recording and stimulation arrays for chronic applications is already at an advanced and well established stage of design and development, many chronic in vivo studies have faced a degeneration in signal stability and in some instances a complete breakdown of a high number of electrode chann…”
BackgroundMaterials and Devices for Micro-invasive Neural Interfacing
Ramadi, K. B., & Cima, M. J. (2019) · MRS Advances · doi:10.1557/adv.2019.424 · Cited by 8
Open-architecture Neural Probes Reduce Cellular Encapsulation
Seymour, J. P., & Kipke, D. R. (2006) · MRS Proceedings · doi:10.1557/proc-0926-cc02-04 · Cited by 7
A Miniature Robot for Autonomous Single Neuron Recordings
Branchaud, E. A., Cham, J. G., Nenadić, Z., Burdick, J. W., & Andersen, R. A. (2006) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/robot.2005.1570394 · Cited by 7
“In chronic recordings, stationary multi-electrode assemblies, which are typically bundles or arrays of thin wires or silicon probes, are surgically implanted in the region of interest [1-3].”
BackgroundCapturing the Electrical Activity of all Cortical Neurons: Are Solutions Within Reach?
Kaszás, A., Meszéna, D., Fiáth, R., Slézia, A., Ulbert, I., & Katona, G. (2025) · Advanced Science · doi:10.1002/advs.202506225 · Cited by 9
Electrode–Neural Tissue Interactions: Immune Responses, Current Technologies, and Future Directions
Kim, G. B., Fattahi, P., & Abidian, M. R. (2013) · Wiley eBooks · doi:10.1002/9783527649600.ch19 · Cited by 6
Nanoneedle-Electrode Devices for In Vivo Recording of Extracellular Action Potentials
Banno, T., Tsuruhara, S., Seikoba, Y., Tonai, R., Yamashita, K., Idogawa, S., Kita, Y., Suzuki, K., Yagi, Y., Kondo, Y., et al. (2022) · ACS Nano · doi:10.1021/acsnano.2c02399 · Cited by 7
Degradation-aware neural imputation: Advancing decoding stability in brain machine interfaces
Kuo, Y.-T., Wang, H.-L., Chen, B.-W., Wang, C.-F., Lo, Y., Lin, S.-H., Chen, P.-C., & Chen, Y. (2025) · APL Bioengineering · doi:10.1063/5.0250296 · Cited by 6
The Bionic Eye: Retinal Prostheses
Park, R. I. (2004) · International Ophthalmology Clinics · doi:10.1097/00004397-200404440-00011 · Cited by 6
“The first report of phosphene (perception of light produced by stimulation of a retinal ganglion cell or the cerebral cortex) production by electrical cortical stimulation was reported by Foerster in 1929.3 Cortical implants were pioneered by Brindley in the 1970s using an array of 180 cortical surface electrodes to s…”
BackgroundInfluentialCytotoxicity of 3C–SiC Investigated Through Strict Adherence to ISO 10993
Frewin, C., Nezafati, M., Noble, K., & Saddow, S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802993-0.00002-2 · Cited by 4
Flexible Electrode for Implantable Neural Devices
Tsang, W. M., & Je, M. (2014) · Springer eBooks · doi:10.1007/978-1-4614-8151-5_6 · Cited by 6
Donoghue, J. P. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00025-5 · Cited by 6
Orbán, G., Meszéna, D., Tasnády, K. R., Rózsa, B. J., Ulbert, I., & Márton, G. (2019) · PLoS ONE · doi:10.1371/journal.pone.0221510 · Cited by 7
Wu, H., Chang, K.-J., Wen, X., Yarmishyn, A. A., Dai, H.-J., Chan, K.-H., Hsiao, Y., Chen, M.-T., Chien, Y., Ma, H., et al. (2022) · Materials Today Advances · doi:10.1016/j.mtadv.2022.100322 · Cited by 6
Kim, Y. J., Jin, Y., Salieb–Beugelaar, G. B., Nam, C., & Stieglitz, T. (2014) · Biomedical Materials · doi:10.1088/1748-6041/9/1/015009 · Cited by 8
“For the substrate materials, polymers such as polyimide [7], polydimethylsiloxane (PDMS) [8] and parylene [9] as well as silicon (Si) [10, 11] have been widely employed.”
A method for monitoring intra-cortical motor cortex responses in an animal model of ischemic stroke
Jensen, W., Rousche, P. J., & Chiganos, T. C. (2006) · Conference proceedings · doi:10.1109/iembs.2006.4397623 · Cited by 6
Self-citationStrategies to Improve Neural Electrode Performance
Guido, K., Clavijo, A. S., Zhu, K., Ding, X., & Ma, K. (2020) · Springer eBooks · doi:10.1007/978-3-030-41854-0_7 · Cited by 5
Chemie der Cyborgs – zur Verknüpfung technischer Systeme mit Lebewesen
Giselbrecht, S., Rapp, B. E., & Niemeyer, C. M. (2013) · Angewandte Chemie · doi:10.1002/ange.201307495 · Cited by 7
The Biocompatibility of Intracortical Microelectrode Recording Arrays for Brain Machine Interfacing
Skousen, J. L., & Tresco, P. A. (2017) · Series on bioengineering and biomedical engineering · doi:10.1142/9789813207158_0011 · Cited by 5
Kosugi, A., Takemi, M., Tia, B., Castagnola, E., Ansaldo, A., Sato, K., Awiszus, F., Seki, K., Ricci, D., Fadiga, L., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aab307 · Cited by 5
Kim, T., Zhong, Y., & Giszter, S. F. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2911912 · Cited by 5
“, Michigan probes [13], [36], [37] and Utah arrays [38], [39].”
Ereifej, E. S., Li, Y., Goss-Varley, M., Kim, Y., Meade, S. M., Chen, K., Rayyan, J., Feng, H., Dona, K. R., McMahon, J. A., et al. (2020) · Micromachines · doi:10.3390/mi11090838 · Cited by 5
Leblois, A., & Pouzat, C. (2017) · Wiley eBooks · doi:10.1002/9781118873397.ch3 · Cited by 5
Neural prostheses and biomedical microsystems in neurological rehabilitation
Koch, K. P. (2007) · Springer eBooks · doi:10.1007/978-3-211-33079-1_56 · Cited by 7
“For the recording of neural signals from the central neural system, a 10 times 10 array was used [8, 28].”
MethodMiniature Neural Interface Microdrive using Parylenecoated Layered Manufacturing
Cham, J. G., Wolf, M. T., Andersen, R. A., & Burdick, J. W. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639175 · Cited by 5
“In chronic recordings, multi-electrode bundles or arrays of stationary thin wires or silicon probes are surgically implanted in the region of interest (for example, [11] [12][13]).”
BackgroundThe Role of Scalp EEG Recordings During Cortical Visual Prosthesis Testing
Stephan, K., Troyk, P. R., Dagnelie, G., Cogan, S. F., Barry, M. P., Grant, P., Lane, F. J., Szlyk, J. P., McNulty, M. L., van Drongelen, W., et al. (2025) · Artificial Organs · doi:10.1111/aor.15023 · Cited by 6
Burkhart, G., Grabinski, S. E., Wang, J., Glusauskas, G., Thompson, A., Lee, A., Zhu, Z., Donskey, C. J., von Recum, H. A., Zhang, L., et al. (2025) · Biomaterials · doi:10.1016/j.biomaterials.2025.123834 · Cited by 4
Won, S., Binder, S., Boyadzhiev, A. M., Zhou, Q., Vafaei, A., Botero, J., Lim, T., Angelucci, A., Blair, S., Fan, Y., et al. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6c07028 · Cited by 4
Electrical interfaces for recording, stimulation, and sensing
Hess‐Dunning, A., & Zorman, C. A. (2015) · Elsevier eBooks · doi:10.1016/b978-0-323-26208-8.00002-9 · Cited by 4
High-channel-count impedance spectroscopy logger
Pothof, F., Sharma, K., Paul, O., & Ruther, P. (2017) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2017.8008328 · Cited by 4
Newcastle Visual Prosthesis Implantable Control Unit
Liu, Y., Fattah, N. A., & Degenaar, P. A. (2020) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs49266.2020.9294853 · Cited by 4
Chhatbar, P. Y., & Francis, J. T. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626832 · Cited by 4
Myoglobin Detection on SiC: Immunosensor Development for Myocardial Infarction
Oliveros, A. (2013) · Cited by 4
Bouton, C. E., & Czura, C. J. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00131-5 · Cited by 5
Implanted intracortical electrodes as chronic neural interfaces to the central nervous systemPreprint
Henderson, P. (2015) · doi:10.7287/peerj.preprints.1255v1 · Cited by 5
“3 Long Term Viability Examination of both Utah and Michigan microarrays showed similar results in that only about 60% of implanted microarrays remained viable8 after 6 months of implantation [77, 68].”
BackgroundResultInvasive Brain Signal Acquisition Techniques: SUA, MUA, LFP, ECoG in Neuroimaging and Recording
Chaudhary, U. (2025) · Springer eBooks · doi:10.1007/978-3-031-76081-5_3 · Cited by 3
Nguyen, C. K., Sturgill, B. S., Srikanthan, B., Dousti, B., Bhatt, M., Khajehzadeh, M., Mangarolia, S., Hasan, N., Hernandez-Reynoso, A. G., Negi, S., et al. (2026) · Frontiers in Neuroscience · doi:10.3389/fnins.2026.1789112 · Cited by 3
“Histological investigations of chronically implanted UEAs have reported glial encapsulation, fibrotic sealing at the array base, and reduced neuronal density near electrode tips (Rousche and Normann, 1998; Black et al., 2018; Joshi-Imre et al., 2019).”
From trade-offs to translation: An interdisciplinary roadmap for neurotechnology
Serrano, R. R., Troughton, J. G., Mirkhani, N., Martínez, N., Mariello, M., Tsigarides, J., Williamson, S., Sapriza, J., Luca, I. S., Dominguez‐Alfaro, A., et al. (2026) · Science Advances · doi:10.1126/sciadv.aee8595 · Cited by 3
“While neuromodulation paired with imaging enhances precision and feed-back ( 60 , 61 ), traditional metallic implants often cause artifacts, heating, or device malfunction ( 62 ).”
León, S. E. D., Higham, S. J., Jung, Y. J., Tong, W., & Garrett, D. J. (2024) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10742 · Cited by 3
Metadata
- Authors
- Rousche, P. J., & Normann, R. A.
- Affiliations
- University of Manchester (GB)
- University of Utah (US)
- Corresponding author
- Normann, Richard A
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 82
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2142255743
- Semantic Scholar
- fd92cba70ad981a178a97e332f6c03cda18c0e4a
- Cited by
- 646
- References
- 31
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 17 · 2023: 18 · 2022: 28 · 2021: 21 · 2020: 31 · 2019: 34 · 2018: 34 · 2017: 36 · 2016: 35 · 2015: 26 · 2014: 51 · 2013: 47 · 2012: 22
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- W. M. Keck Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- chronic neural recording, silicon microelectrodes, sensory cortex, cats, astroglial response, fibrous encapsulation, electrode implantation
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Electrodes, Implanted, Microelectrodes, Somatosensory Cortex, Utah, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.