Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
The DOI matches its Crossref record; 28 of the 31 references it cites were found in a registry or an index.
Abstract
The Utah Intracortical Electrode Array (UIEA) is an array of 100 penetrating silicon microelectrodes designed to focally electrically stimulate or record neurons residing in a single layer up to 1.5 mm beneath the surface of the cerebral cortex. Apart from its use as a unique tool to study parallel processing in the central nervous system, this array could form the platform for a cortical neuroprosthetic system. Although the UIEA has been used extensively in acute neural recording and stimulation experiments, its long-term performance in a chronic application has yet to be demonstrated. As an initial investigation into the feasibility of long-term cortical recording with an array of microelectrodes, we have hard-wired a subset of 11 electrodes of the UIEA to a percutaneous connector. This chronic UIEA assembly was then implanted into the cerebral cortices of ten cats for durations ranging from 2 to 13 months; over which time, both random and stimulus-evoked single and multiple unit action potentials were periodically recorded. On average, after a 6-month implant period, 60% of implanted arrays could still record some type of activity. Post-sacrifice dissections revealed a fibrous encapsulation of the UIEA. Although most implanted cortex was histologically normal, evidence of a chronic astroglial response was seen in a few cases. The results of the reported experiments indicate that the UIEA can be successfully used for limited times in a chronic recording application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional BMIs with probe-like morphology for LFP recordings are generally small and rigid.[338]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [338]
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationRepresentation of cochlea within primary auditory cortex in the cat
Merzenich, M. M., Knight, P. L., & Roth, G. L. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.231 · Cited by 637
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationA method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationA driveable bundle of microwires for collecting single-unit data from freely-moving rats
Kubie, J. L. (1984) · Physiology & Behavior · doi:10.1016/0031-9384(84)90080-5 · Cited by 184
Research works printed but not linked: 2
- DeYoe EA. An Investigation in the Awake Macaque of the Threshold for Detection of Electrical Currents Applied to Striate Cortex: Psychophysical Properties and Laminar Differences. Ph.D. Thesis, University of Rochester, 1983.
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
Cited by
Items 501–600 of 662
Brain Control and Sensing of Artificial Limbs
Schulman, J. H. (2009) · Biological and medical physics series · doi:10.1007/978-0-387-77261-5_9 · Cited by 3
“In the 1990s Dr. Richard Norman and his group at the University of Utah developed the bed of nails (BON) electrode array for detecting and studying signals in the human brain [9], and individual neurons [ 10 ].”
BackgroundMethodBouton, C. E. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-805353-9.00029-2 · Cited by 3
Neuroprosthetic Interfaces – The Reality Behind Bionics and Cyborgs
Loeb, G. E. (2011) · Brill | mentis eBooks · doi:10.30965/9783957438843_015 · Cited by 3
“…can be implanted into brain, spinal cord and peripheral nerves to record or stimulate individual or small clusters of neurons (Branner et al., 2004; Rousche and Normann, 1998; Wise and Najafi, 1991), but the body tends to wall them off with connective tissue, reducing their efficacy over a few…”
BackgroundZhang, X., Ding, J., Zou, L., Tian, H., Fang, Y. Z., & Wang, J. (2023) · Journal of Materials Chemistry B · doi:10.1039/d2tb02665a · Cited by 4
SU-8/silicon hybrid three dimensional intraneural electrode array
Pemba, D., Wong, W. M., & Tang, W. C. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6695930 · Cited by 3
“shape, which allows us to utilize well established processes for electrode material deposition and encapsulation coating[13], [14], [15].”
MethodBiocompatibility of SiC for Neurological Applications
Frewin, C. L., Locke, C., Saddow, S. E., & Weeber, E. J. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-385906-8.00006-4 · Cited by 4
The Future of Neural Interface Technology
Park, M. C., Goldman, M. A., Belknap, T. W., & Friehs, G. M. (2009) · Springer eBooks · doi:10.1007/978-3-540-69960-6_193 · Cited by 7
Identification and quantification of electrical leakage pathways in floating microelectrode arrays
Bredeson, S. D., Troyk, P. R., Suh, S., & Bak, M. (2013) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6609807 · Cited by 3
Impedance characterization of microarray recording electrodes in vitro
Merrill, D. R., & Tresco, P. A. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404210 · Cited by 3
SiC for Brain–Machine Interface (BMI)
Frewin, C. L., Abbati, L., Weeber, E. J., & Saddow, S. E. (2011) · Elsevier eBooks · doi:10.1016/b978-0-12-385906-8.00007-6 · Cited by 3
In Vitro and In Vivo Biocompatibility Testing of Silicon Carbide for Neural Interfaces
Knaack, G. L. (2014) · doi:10.13021/mars/7344 · Cited by 5
Baião, P. (2014) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT) · Cited by 3
Nanoelectronics for Neuroscience
Rastogi, S. K., & Cohen‐Karni, T. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-801238-3.99893-3 · Cited by 3
Electrochemical Roughening and Carbon Nanotube Coating of Tetrodes for Chronic Single-Unit RecordingPreprint
Xia, Z., Arias-Gil, G., Deckert, M., Vollmer, M., Curran, A. W., Herrera-Molina, R., Brosch, M., Krug, K., Schmidt, B., Ohl, F. W., et al. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/738245 · Cited by 4
Forrest, A. M., Kunigk, N. G., Collinger, J. L., Gaunt, R. A., Chen, X., Geest, J. P. V., & Kozai, T. D. Y. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae1bda · Cited by 3
“While intracortical arrays can record action potentials for years, their ability to record from nearby neurons is highly variable [22, 23] and diminishes over time [15, 19, 24–27].”
Full‐Stack Architectures for Intelligent Brain‐Computer Interfaces
Lee, H. K., Kim, H. B., Park, S. U., Joo, J., Min, J., Lee, G., Kang, J. Y., Jeong, H., Yoo, J., & Won, S. M. (2026) · Advanced Science · doi:10.1002/advs.75838 · Cited by 2
“Conventional platforms such as Michigan probes [ 119, 120 ] and Utah arrays [ 121–123 ] established depth-resolved multichannel recording; however, their rigid silicon-based geometries impose fixed layouts, limited adaptability, and increased tissue damage, constraining long-term stability and…”
Restoring vision and touch with cortical microstimulation
Valle, G. D., Oswalt, D. N., Gaunt, R. A., Roelfsema, P. R., Greenspon, C. M., & Fernandez, E. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-026-00449-z · Cited by 2
“These arrays are typically fabricated from silicon shafts with platinum or iridium oxide contacts, insulated with biocompatible coatings such as parylene-C to minimize tissue reaction 38 .”
A roadmap to navigate the future of neural engineering
Grill, W. M., Chestek, C. A., Wang, Y., Aberra, A. S., Destexhe, A., Chan, R. H. M., Lu, B., Hanein, Y., Robinson, J. T., Whitmire, C., et al. (2026) · Journal of Neural Engineering · doi:10.1088/1741-2552/ae78c2 · Cited by 3
Fares, H., Ronchini, M., Zamani, M., Farkhani, H., Chiappalone, M., Neftci, E., & Moradi, F. (2026) · npj Biomedical Innovations. · doi:10.1038/s44385-026-00074-w · Cited by 2
“E Intracorticalpenetrating needleshaped microelectrodesforrecording e.g., microwire bundles integrated with CMOS chips for bundles 78 , Utah array by Blackrock neurotech 80 , fl oating microelectrodes array (MEA), planar Michigan probe 81 .”
Neurotechnology for monitoring and restoring sensory, motor, and autonomic functions
Wu, P. C., Knaack, G. L., & Weber, D. J. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2222967 · Cited by 2
Wan, Z., Liu, T., Ran, X., Liu, P., Chen, W., & Zhang, S. (2023) · Frontiers in Computational Neuroscience · doi:10.3389/fncom.2023.1135783 · Cited by 2
“Previous chronic iBCI studies have reported a decrease in MFR (Wang et al., 2014; Ahmadi et al., 2021) and NIU as recording time increases (Rousche and Normann, 1998; Sharma et al., 2015; Ahmadi et al., 2021), as well as time-varying changes in neural PDs (Ganguly and Carmena, 2009; Fraser and…”
BackgroundLešták, J. (2024) · Czech and Slovak Ophthalmology · doi:10.31348/2024/2 · Cited by 2
Developing Chitosan-based Biomaterials for Brain Repair and Neuroprosthetics
Cao, Z. H. (2010) · Cited by 3
Flexible neural probe integrated microchannel and optical fiber for multifle stimulation
Lee, B.-Y., Jin, J., Park, J. H., & Kim, J. (2013) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2013.6626767 · Cited by 3
Miniaturized Technologies for Enhancement of Motor Plasticity
Moorjani, S. G. (2016) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2016.00030 · Cited by 5
“, 1995), cats (John and Morgades, 1969; Rousche and Normann, 1998; Liu et al., 1999), and non-human primates (NHPs; Schmidt et al.”
BackgroundConjugated Polymers for Neural Interfaces : Prospects, possibilities and future challenges
Asplund, M. (2009) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 4
Neural Interfaces: from Human Nerves to Electronics
Falcone, J., Birjiniuk, J., Kretschmar, R., & Bellamkonda, R. V. (2014) · Wiley eBooks · doi:10.1002/9783527673148.ch6 · Cited by 2
Braeken, D., & Prodanov, D. (2010) · InTech eBooks · doi:10.5772/7613 · Cited by 3
“(2009); Rubehn et al. (2009)) and peripheral nerve recording (Navarro et al.”
BackgroundMethodAFM and Cell Staining to Assess the In Vitro Biocompatibility of Opaque Surfaces
Christopher, L., Oliveros, A., Weeber, E. J., & Stephen, E. S. (2012) · InTech eBooks · doi:10.5772/37078 · Cited by 2
“…medically unsuitable, but neural implant (NI) devices which are electrode based are extremely vulnerable to changes in impedance and fail to function typically within months to a few years after glial encapsulation (Polikov et al., 2005; Rousche & Normann, 1998; J. C. Williams et al., 1999).”
BackgroundAbbati, L., Frewin, C. L., Placidi, P., Saddow, S. E., & Scorzoni, A. (2011) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi.2011.6004684 · Cited by 2
“Also materials are a key aspect when the device has to be implanted: silicon has been reported to be significantly damaged after only a few months in a cat's brain [8] while another material, silicon carbide (SiC), is considered a very promising material for the fabrication of implantable devices [9].”
BackgroundNew Frontiers in Population Recording
Fraser, G. W. (2011) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 2
Kim, B. J., Kim, Y., Seo, M., Kim, E. J., Jeon, J., & Chung, T. D. (2016) · ChemElectroChem · doi:10.1002/celc.201600404 · Cited by 2
Visual prostheses and other assistive devices
Memon, M. A., & Rizzo, J. F. (2010) · Elsevier eBooks · doi:10.1016/b978-0-7020-2983-7.00075-9 · Cited by 2
Moxon, K. A. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_4 · Cited by 2
Reichert, W. M. (2007) · CRC Press eBooks · doi:10.1201/9781420009309-17 · Cited by 2
A Control System for Positioning Recording Electrodes to Isolate Neurons in Extracellular Recordings
Branchaud, E. A. (2006) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/6hhc-5456 · Cited by 2
Microengineered Neural Probes for In Vivo Recording
Valles, K. D. B. (2009) · Methods in molecular biology · doi:10.1007/978-1-60327-106-6_6 · Cited by 2
McConnell, G. C. (2008) · SMARTech Repository (Georgia Institute of Technology) · Cited by 7
Pérez, J. L. M. (2010) · UPM Digital Archive (Technical University of Madrid) · doi:10.20868/upm.thesis.5855 · Cited by 4
Magnetic resonance identification tags for ultra-flexible electrodes
Özil, E., Gombkötő, P., Apostolelli, A., Yaşar, T. B., Vavladeli, A., Marks, M., Rohr-Fukuma, M., von der Behrens, W., & Yanik, M. F. (2026) · Nature Communications · doi:10.1038/s41467-026-71887-x · Cited by 1
Spatial richness of neural magnetic fields
Ali, Z., & Poon, A. S. Y. (2026) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1014283 · Cited by 1
“Our results demonstrate the untapped in-formational potential of cellular-scale neural magnetic fields, and should motivate the development of micro-scale magnetic sensors capable of measuring them.”
Park, S., Kim, M. S., Lee, H., Lee, J., Chou, N., & Shin, H. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.117084 · Cited by 1
Sasaki, H., Shimizu, S., Nerchan, R. A., Yamashita, K., Takahashi, N., Chinone, R., Kurashige, Y., Numano, R., Koida, K., Ohsawa, M., et al. (2025) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2025.100915 · Cited by 2
Biocompatible Lubricant-Coated Flexible Neural Probes with Enhanced Long-Term Recording Stability
Lee, H., Lee, S., Hwang, K. S., Kim, G., Hong, Y., Kim, M. S., Eun, J., Kim, H. N., Chou, N., & Shin, H. (2026) · ACS Applied Bio Materials · doi:10.1021/acsabm.5c02232 · Cited by 1
Advances in neuroprostheses: interfaces, materials, and applications
He, E., Chen, K., Liu, S., Chen, H., Xiao, Y., Chen, R., Tu, P., Pan, G., & Lin, P. (2026) · Nano Convergence · doi:10.1186/s40580-026-00552-2 · Cited by 1
“8a) [94, 95].”
Fabrication of microtip electrode array integrated with self-aligned reference electrode
Maeng, B.-R., Lee, S.-K., Bai, S. J., & Park, J. (2015) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2015.7181185 · Cited by 1
Bredeson, S. D., Troyk, P. R., Suh, S., & Bak, M. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696011 · Cited by 1
High-fidelity compression of extracellular recordings from motor cortex
Zhang, R., Pan, G., Wang, Y., & Hu, Z. (2014) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2014.6889937 · Cited by 1
“On the contrary, the invasive methods use surgically implanted electrodes, recording extracellular neurons’ signals with finest detail [4], [5], which is referred to ”action potential”, or ”spikes” in individual neurons.”
MethodDeep-brain silicon multielectrodes with surface-modified Pt recording sites
Márton, G., Fekete, Z., Bakos, I., Battistig, G., Pongracz, A., Baracskay, P., Juhász, G. D., & Bársony, I. (2012) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2012.6411325 · Cited by 2
“Silicon-based multielectrodes are also used in cat [3] or primate [4] in vivo experiments, implanted close to the brain surface, typically into the cerebral cortex.”
BackgroundZheng, X., Zeng, J., Chen, T., Lin, Y., Yu, L., Li, Y., Lin, Z., Wu, X., Chen, F., Kang, D., et al. (2014) · Neurological Sciences · doi:10.1007/s10072-014-1775-8 · Cited by 1
“But it is so far mainly used in animal cortex [12, 13].”
BackgroundHigh performance bio-integrated devices
Kim, D., Lee, J., & Park, M. (2014) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2051191 · Cited by 1
Micromachining Techniques for Realization of Three-Dimensional Microelectrode Arrays
Rajaraman, S. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_5 · Cited by 2
Intra-operative chemical diagnostics in the brain using enzyme-based ceramic microelectrode arrays
Gerhardt, G. A., Huettl, P. F., Pomerleau, F., Quintero, G., & Burmeister, J. J. (2010) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2010.5690939 · Cited by 1
“Of particular note is that longer term implantation of the MEAs for up to 6 months has shown that the electrodes and materials produce very little gliosis and scarring relative to microdialysis probes and other microelectrode technologies [13,14].”
BackgroundNEURONAL SIGNAL DESCRIPTION AFTER CHRONIC STAINLESS STEEL MICROELECTRODE ARRAY IMPLANTS IN MARMOSETS
Ribeiro, M. W. (2014) · Cited by 1
Overstreet, C. K. (2013) · Cited by 1
Transmission of wireless neural signals through a 0.18µm CMOS low-power amplifier
Gazziro, M., Braga, C. F. R., Moreira, D. A., de Carvalho, A. C. P. L. F., Rodrigues, J. F., Navarro, J., Ardila, J. C. M., Mioni, D. P., Pessatti, M. P., Fabbro, P. A. D., et al. (2015) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2015.7319537 · Cited by 1
“First, commonplace systems are based on batteries that eventually discharge and must be replaced after short periods of time, resulting in additional maintenance requirements; Second, many systems rely on materials that may not have reliable biocompatibility, and can possibly erode with time, demanding costly and high…”
BackgroundXie, X. (2014) · PhDT · doi:10.26053/0h-449a-s1g0 · Cited by 1
Progress in Peripheral Neural Interfaces
Qiao, S., Mauser, K. A., & Yoshida, K. (2013) · Wiley eBooks · doi:10.1002/9781118628522.ch4 · Cited by 1
Integration of Process-Incompatible Materials for Microfabricated Polymer-Based Neural Interfaces
Hess‐Dunning, A. (2011) · OhioLink ETD Center (Ohio Library and Information Network) · Cited by 2
The History and Future of LEGS
Tepe, V., Salas-Snyder, S., & Peterson, C. M. (2017) · Springer eBooks · doi:10.1007/978-1-4939-7247-0_1 · Cited by 1
Low-cost Non-etched Silicon Neural Probe
Ribeiro, J. F., Pimenta, S., Fernandes, H. C., Goncalves, S. B., Souto, M. R., Goncalves, A. M., de Vasconcelos, N. A. P., Monteiro, P., & Correia, J. H. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8716910 · Cited by 1
“Michigan array [6] and Utah array [7], [8] are Si micromachined probes with several microelectrodes.”
BackgroundHughes, C. L. (2021) · D-Scholarship@Pitt (University of Pittsburgh) · Cited by 4
Neuroprothetik und Funktionelle Elektrostimulation
(2010) · Biomedizinische Technik/Biomedical Engineering · doi:10.1515/bmt.2010.715 · Cited by 1
Electrophysiological Techniques for Studying Tactile Perception in Rats
Öztürk, S., Devecıoğlu, İ., Vardar, B., Duvan, F. T., & Güçlü, B. (2023) · Neuromethods · doi:10.1007/978-1-0716-3068-6_16 · Cited by 1
Advanced age is not a barrier to chronic intracortical single-unit recording in rat cortex
Nolta, N. F., Christensen, M. B., & Tresco, P. A. (2024) · Frontiers in Neuroscience · doi:10.3389/fnins.2024.1389556 · Cited by 1
Volumetric mesoscopic electrophysiology: a new imaging modality for the nonhuman primate
Teichert, T., Papp, L., Vincze, F., Burns, N., Goodell, B., Ahmed, Z., Holmes, A., Gray, C. M., Chamanzar, M., & Gurnsey, K. (2025) · Journal of Neurophysiology · doi:10.1152/jn.00399.2024 · Cited by 2
Song, E., Lu, Y., & Zhang, H. (2025) · Wiley eBooks · doi:10.1002/9783527845507.ch6 · Cited by 1
DESIGN, FABRICATION, AND CHARACTERIZATION OF MICROELECTRODES FOR BRAIN-MACHINE INTERFACES By
Patrick, E. E., & Patrick, C. E. (2010) · Cited by 1
Nano-Watt Modular Integrated Circuits for Wireless Neural Interface.
Chang, S.-I. (2013) · Deep Blue (University of Michigan) · Cited by 1
Development of a Bi-Directional Electronics Platform for Advanced Neural Applications
Abbati, L. (2012) · Digital Commons - University of South Florida (University of South Florida) · Cited by 1
The Science in Science Fiction's Artificial Men
Englehart, K. B., & MacIsaac, D. (2006) · Cited by 6
Imaging electrical activity of neurons with metamaterial nanosensorsPreprint
Beletskiy, R. V. (2013) · arXiv (Cornell University) · doi:10.48550/arxiv.1308.6636 · Cited by 1
Huang, R. K.-J. (2010) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/vmzb-0n20 · Cited by 1
Development and Characterization of Anti-Inflammatory Coatings for Implanted Neural Probes
Zhong, Y. (2006) · SMARTech Repository (Georgia Institute of Technology) · Cited by 1
NEXT GENERATION OF CORTICAL DEVICES
Rousche, P. J., & Kipke, D. R. (2004) · Series on bioengineering and biomedical engineering · doi:10.1142/9789812561763_0041 · Cited by 2
Self-citationEncoding, coordination, and decision making in the primate fronto-parietal grasping network
Dann, B. (2017) · eDiss (Georg-August-Universität Göttingen) · doi:10.53846/goediss-6497 · Cited by 1
Oswalt, D. N., Datta, P., Talbot, N., Mirzadeh, Z., & Greger, B. E. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.12.15.422891 · Cited by 2
“Intracortical arrays consist of closely spaced penetrating electrodes and directly target deeper cortical layers [23].”
BackgroundOrbán, G., Meszéna, D., Tasnády, K. R., Rózsa, B. J., Ulbert, I., & Márton, G. (2019) · PLoS ONE · doi:10.1371/journal.pone.0224590 · Cited by 1
Neuroelectrophysiology-Compatible Electrolytic LesioningPreprint
Bray, I. E., Clarke, S. E., Casey, K. M., & Nuyujukian, P. (2023) · eLife · doi:10.7554/elife.84385.1 · Cited by 1
Neuroelectrophysiology-Compatible Electrolytic LesioningPreprint
Bray, I. E., Clarke, S. E., Casey, K. M., & Nuyujukian, P. (2024) · eLife · doi:10.7554/elife.84385.2 · Cited by 1
Contribution au développement d'interfaces neuro-électroniques
Cottance, M. (2014) · theses.fr (ABES) · doi:10.70675/8b542039z40bbz4190zb327z619be13fa0ad · Cited by 2
Deep Learning–Based Control of Electrically Evoked Activity in Human Visual Cortex
Moure, P., Granley, J., Grani, F., Soo, L., Lozano, A., López-Peco, R., Villamarin-Ortiz, A., Soto-Sanchez, C., Liu, S.-C., Beyeler, M., et al. (2025) · bioRxiv · doi:10.1101/2025.09.24.678361
A Shielded Silicon Neural Probe for Higher Signal-to-Noise Ratio Performance
Song, J. K., Oh, S., & Kim, S. J. (2003) · Seoul National University Open Repository (Seoul National University)
Analog Front-End Circuits for Massive Parallel 3-D Neural Microsystems.
Al-Ashmouny, K. M. (2013) · Deep Blue (University of Michigan)
Quantitative Modeling of the Visual System
Nishimoto, S. (2012) · The Brain & Neural Networks · doi:10.3902/jnns.19.39
Chan, A. M. (2012) · Digital Access to Scholarship at Harvard (DASH) (Harvard University)
Slope and cantilever type electrode fabrication for measurement of neurospheroid signal
Jin, J., Lee, B.-Y., You, J., Kim, J., Park, J., Hwang, Y., & Chun, K. (2013) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2013.6688380
Cognitive neural prosthetics: brain machine interfaces based in parietal cortex
Dep, M. (2005) · CaltechTHESIS (California Institute of Technology) · doi:10.7907/v2bz-eg30
Bjånes, D. A. (2014) · D-Scholarship@Pitt (University of Pittsburgh)
Large-Scale Multiunit Recording Polytrodes: High-Density Silicon Electrode Arrays for
Blanche, T. J., Spacek, M. A., Hetke, J. F., Nicholas, V., Mechler, F., Victor, J. D., Schmid, A., Qin, H., Beckers, G. J. L., Gahr, M. L., et al. (2015)
Awake, Behaving Primates Recording Chronically From the Same Neurons in
Tolias, A. S., Ecker, A. S., Siapas, A. G., Cottereau, B. R., McKee, S. P., Norcia, A. M., McMahon, D. B. T., Bondar, I. V., Afuwape, O. A., Ide, D. C., et al. (2015)
A MEMS BASED ELECTRODE ARRAY FOR CORTICAL SURFACE POTENTIAL RECORDINGS
Hollenberg, B. A. (2005) · Research Exchange (Washington State University)
Modulating macrophage response to biomaterials
Zaveri, T. D. (2011)
SILICON MICROELECTRODE ARRAYS FOR IN SITU ENVIRONMENTAL MONITORING
Wei, X. (2005) · OhioLink ETD Center (Ohio Library and Information Network)
Moxon, K. A. (2012) · Springer eBooks · doi:10.1007/978-1-4614-5227-0_3
In Vivo Exploration of Robust Implantable Devices Constructed From Biocompatible 3C–SiC
Frewin, C., Thomas, S., Coletti, C., & Saddow, S. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802993-0.00007-1 · Cited by 1
Brain–Machine Interface and Rehabilitation
Pham, M. H., Taghva, A. S., & Rezai, A. R. (2013) · CRC Press eBooks · doi:10.1201/b15274-34
Biopassive and bioactive coatings for neural implants
Achyuta, A. K. H. (2009) · Digital Repository Service (Northeastern University) · doi:10.17760/d20000821
Advancing Electroanalytical Methods for Monitoring Chemical Messenger Release
Walsh, P. L. (2012) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/h9en-z430
Wireless, Implantable Neuroprostheses: Applying Advanced Technology to Untether the Mind
Borton, D. A., & Nurmikko, A. V. (2013) · Wiley eBooks · doi:10.1002/9781118678107.ch21
Metadata
- Authors
- Rousche, P. J., & Normann, R. A.
- Affiliations
- University of Manchester (GB)
- University of Utah (US)
- Corresponding author
- Normann, Richard A
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 82
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2142255743
- Semantic Scholar
- fd92cba70ad981a178a97e332f6c03cda18c0e4a
- Cited by
- 646
- References
- 31
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 17 · 2023: 18 · 2022: 28 · 2021: 21 · 2020: 31 · 2019: 34 · 2018: 34 · 2017: 36 · 2016: 35 · 2015: 26 · 2014: 51 · 2013: 47 · 2012: 22
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- W. M. Keck Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- chronic neural recording, silicon microelectrodes, sensory cortex, cats, astroglial response, fibrous encapsulation, electrode implantation
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Electrodes, Implanted, Microelectrodes, Somatosensory Cortex, Utah, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.