Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
The DOI matches its Crossref record; 28 of the 31 references it cites were found in a registry or an index.
Abstract
The Utah Intracortical Electrode Array (UIEA) is an array of 100 penetrating silicon microelectrodes designed to focally electrically stimulate or record neurons residing in a single layer up to 1.5 mm beneath the surface of the cerebral cortex. Apart from its use as a unique tool to study parallel processing in the central nervous system, this array could form the platform for a cortical neuroprosthetic system. Although the UIEA has been used extensively in acute neural recording and stimulation experiments, its long-term performance in a chronic application has yet to be demonstrated. As an initial investigation into the feasibility of long-term cortical recording with an array of microelectrodes, we have hard-wired a subset of 11 electrodes of the UIEA to a percutaneous connector. This chronic UIEA assembly was then implanted into the cerebral cortices of ten cats for durations ranging from 2 to 13 months; over which time, both random and stimulus-evoked single and multiple unit action potentials were periodically recorded. On average, after a 6-month implant period, 60% of implanted arrays could still record some type of activity. Post-sacrifice dissections revealed a fibrous encapsulation of the UIEA. Although most implanted cortex was histologically normal, evidence of a chronic astroglial response was seen in a few cases. The results of the reported experiments indicate that the UIEA can be successfully used for limited times in a chronic recording application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional BMIs with probe-like morphology for LFP recordings are generally small and rigid.[338]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [338]
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationRepresentation of cochlea within primary auditory cortex in the cat
Merzenich, M. M., Knight, P. L., & Roth, G. L. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.231 · Cited by 637
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationA method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationA driveable bundle of microwires for collecting single-unit data from freely-moving rats
Kubie, J. L. (1984) · Physiology & Behavior · doi:10.1016/0031-9384(84)90080-5 · Cited by 184
Research works printed but not linked: 2
- DeYoe EA. An Investigation in the Awake Macaque of the Threshold for Detection of Electrical Currents Applied to Striate Cortex: Psychophysical Properties and Laminar Differences. Ph.D. Thesis, University of Rochester, 1983.
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
Cited by
Items 301–400 of 662
Ultra-long term stability of single units using chronically implanted multielectrode arrays
Vaidya, M., Dickey, A. S., Best, M. D., Coles, J., Balasubramanian, K., Suminski, A. J., & Hatsopoulos, N. G. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944715 · Cited by 27
“Initial attempts to track neurons involved visually inspecting the waveform shape across days [1], by computing the correlation between average waveforms [2], or by comparing the clustering in principal component space [3].”
Gong, W., Jure, S., Bakkum, D. J., Jäckel, D., Obien, M. E. J., Radivojević, M., & Hierlemann, A. R. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00537 · Cited by 30
“The spike waveform analysis over days has been demonstrated in other studies (Rousche and Normann, 1998; Schmitzer-Torbert and Redish, 2004; Guldimann et al., 2012), and the authors argued that very similar waveforms can be used to infer that the same neuron has been recorded from.”
BackgroundCaldwell, R., Sharma, R., Takmakov, P. A., Street, M. G., Solzbacher, F., Tathireddy, P., & Rieth, L. W. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.10.002 · Cited by 30
Nguyen, T., Phan, H., Kamble, H., Vadivelu, R. K., Dinh, T., Iacopi, A., Walker, G., Hold, L., Nguyen, N., & Dao, D. V. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b15381 · Cited by 31
Wan, H., Zhuang, L., Pan, Y., Gao, F., Tu, J., Zhang, B., & Wang, P. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816034-3.00002-x · Cited by 33
In Vivo Penetrating Microelectrodes for Brain Electrophysiology
Erofeev, A., Antifeev, I., Bolshakova, A. V., Борисович, Б. И., & Власова, О. Л. (2022) · Sensors · doi:10.3390/s22239085 · Cited by 30
Mols, K., Musa, S., Nuttin, B., Lagae, L., & Bonin, V. (2017) · Scientific Reports · doi:10.1038/s41598-017-15121-1 · Cited by 31
Comparison of the In Vitro and In Vivo Electrochemical Performance of Bionic Electrodes
Harris, A. R., Newbold, C., Stathopoulos, D., Carter, P., Cowan, R., & Wallace, G. G. (2022) · Micromachines · doi:10.3390/mi13010103 · Cited by 27
Brain–Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.2200/s00053ed1v01y200710bme017 · Cited by 33
Think big, see small—A review of nanomaterials for neural interfaces
Zeng, Q., Li, X., Zhang, S., Deng, C., & Wu, T. (2021) · Nano Select · doi:10.1002/nano.202100256 · Cited by 25
Urdaneta, M. E., Kunigk, N. G., Currlin, S., Delgado, F., Fried, S. I., & Otto, K. J. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.908858 · Cited by 25
Electrode sharpness and insertion speed reduce tissue damage near high-density penetrating arrays
McNamara, I., Wellman, S. M., Li, L., Eles, J. R., Savya, S. P., Sohal, H. S., Angle, M. R., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad36e1 · Cited by 25
“However, extensive documentation highlighting the significant variability in glial scarring around stiff devices suggests the involvement of additional contributors to this undesirable tissue reaction [25, 28, 41, 90–92].”
BackgroundMultiple Implants Do Not Aggravate the Tissue Reaction in Rat Brain
Lind, G., Gällentoft, L., Danielsen, N., Schouenborg, J., & Pettersson, L. M. E. (2012) · PLoS ONE · doi:10.1371/journal.pone.0047509 · Cited by 28
“However, all types of electrodes available today show deteriorating recording capabilities over time [4,5,6].”
Methodological considerations for a chronic neural interface with the cuneate nucleus of macaques
Suresh, A. K., Winberry, J. E., Versteeg, C., Chowdhury, R. H., Tomlinson, T., Rosenow, J. M., Miller, L. E., & Bensmaïa, S. J. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00436.2017 · Cited by 23
“…• www.jn.org The insertion technique varied depending on the array: UEAs were implanted with the standard Blackrock pneumatic inserter, and FMAs were inserted slowly with a stereotaxic instrument while being held by a vacuum wand (Musallam et al. 2007; Rousche and Normann 1998).”
MethodLo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Ahmed, I., Coffey, K. R., Barker, D., Saste, K., Kals, K., Kaplan, H. M., et al. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa9fad · Cited by 24
“microwires, Blackrock Microsystems (Utah) arrays, or NeuroNexus (Michigan) arrays) can often sustain recording performance for several months (6–12 months with good signal-to-noise ratio) before the signal quality begins to drop significantly approximately 18–24 months after device implantation [20, 24, 25] until the…”
BackgroundPlacing Sites on the Edge of Planar Silicon Microelectrodes Enhances Chronic Recording Functionality
Lee, H. C., Gaire, J., Roysam, B., & Otto, K. J. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2715811 · Cited by 23
“Similar to previously reported literature [2], [4]–[6], [45], the quality of neural recordings degraded over time regardless of the”
ResultSteerable Microinvasive Probes for Localized Drug Delivery to Deep Tissue
Cotler, M. J., Rousseau, E. B., Ramadi, K. B., Fang, J., Graybiel, A. M., Langer, R., & Cima, M. J. (2019) · Small · doi:10.1002/smll.201901459 · Cited by 24
Thin-film epidural microelectrode arrays for somatosensory and motor cortex mapping in rat
Hosp, J. A., Molina-Luna, K., Hertler, B., Atiemo, C. O., Stett, A., & Luft, A. R. (2008) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2008.05.010 · Cited by 29
“Average electrode impedances are in the range of intracortically implanted needle electrodes (Rousche and Normann, 1998; Suner et al., 2005), polyamide ore polyimide-based surface arrays (Takahashi et al., 2003; Hollenberg et al., 2006), indicating comparable recording conditions with respect to…”
InfluentialVisualization of the intact interface between neural tissue and implanted microelectrode arrays
Holecko, M. M., Williams, J. C., & Massia, S. P. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/005 · Cited by 25
“…of applications for microelectrodes includes: gaining a better understanding of the functions of individual neurons and complex neural networks [1–3]; providing an interface between the central nervous system and prosthetics interacting with the environment [1–5] and treating various neurological…”
BackgroundFeasibility of Neural Stimulation With Floating-Light-Activated Microelectrical Stimulators
Abdo, A., & Şahin, M. (2011) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2011.2114882 · Cited by 24
Invasive Brain-Computer Interfaces and Neural Recordings From Humans
Klaes, C. (2018) · Handbook of behavioral neuroscience · doi:10.1016/b978-0-12-812028-6.00028-8 · Cited by 26
Microfabrication of ultra-long reinforced silicon neural electrodes
Hajj-Hassan, M., Chodavarapu, V. P., & Musallam, S. (2009) · Micro & Nano Letters · doi:10.1049/mnl:20090007 · Cited by 22
“Conventional electrodes, such as Utah Array [14] and Michigan Array [15], typically reach lengths less than 5 mm.”
MethodEgeland, B. M., Urbanchek, M. G., Peramo, A., Richardson-Burns, S. M., Martin, D. C., Kipke, D. R., Kuzon, W. M., & Cederna, P. S. (2010) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0b013e3181f61848 · Cited by 23
Biomechanical Characterization of Needle Piercing Into Peripheral Nervous Tissue
Sergi, P. N., Carrozza, M. C., Dario, P., & Micera, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879463 · Cited by 24
“Several needles used in neural interfaces have a conical form [40]–[ 44 ].”
BackgroundRecording advances for neural prosthetics
Andersen, R. A., Burdick, J. W., Musallam, S., Scherberger, H., Pesaran, B., Meeker, D., Corneil, B. D., Fineman, I., Nenadić, Z., Branchaud, E. A., et al. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2004.1404494 · Cited by 22
“While some arrays continued to record some signals for periods of up to a few years [1, 2], the quality of single cell activation in most channels of fixed-geometry implanted electrode arrays noticeably degrades after a few months [3].”
BackgroundThin flexible arrays for long-term multi-electrode recordings in macaque primary visual cortex
Merken, L., Schelles, M., Ceyssens, F., Kraft, M. D., & Janssen, P. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac98e2 · Cited by 21
Yi, D., Yao, Y., Wang, Y., & Chen, L. (2024) · Journal of Manufacturing Processes · doi:10.1016/j.jmapro.2024.07.100 · Cited by 22
Development of speech prostheses: current status and recent advances
Brumberg, J. S., & Guenther, F. H. (2010) · Expert Review of Medical Devices · doi:10.1586/erd.10.34 · Cited by 26
Song, K., Kim, J., Cho, S., Kim, N., Jung, D., Choo, H., & Lee, J. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800419 · Cited by 22
Sharon, A., Jankowski, M. M., Shmoel, N., Erez, H., & Spira, M. E. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.646914 · Cited by 21
Cellular Mechanisms of Electromagnetic Field in Traumatic Brain Injury
Siddiqi, I., Marino, M. A., Agrawal, D. K., Baron, D., Connett, D. A., & Miulli, D. E. (2023) · Journal of Biotechnology and Biomedicine · doi:10.26502/jbb.2642-91280075 · Cited by 24
“Rousche and Normann reported that this same type of array called the Utah Intracortical Electrode Array stimulates and records in a single layer up to 1.5 millimeter (mm) beneath the surface [2].”
BackgroundInfluentialGreenberg, R. J. (2000) · Neuromodulation Technology at the Neural Interface · doi:10.1046/j.1525-1403.2000.00161.x · Cited by 21
Eleryan, A., Vaidya, M., Southerland, J., Badreldin, I. S., Balasubramanian, K., Fagg, A. H., Hatsopoulos, N., & Oweiss, K. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00023 · Cited by 20
“…assessed by visual inspection of the similarity between units’ waveforms to average waveforms from datasets collected across multiple days of recording (Rousche and Normann, 1998; Nicolelis et al., 2003; Carmena et al., 2005; Linderman et al., 2006; Chestek et al., 2007; Ganguly and Carmena, 2009).”
MethodPenetrating multichannel stimulation and recording electrodes in auditory prosthesis research
Anderson, D. J. (2008) · Hearing Research · doi:10.1016/j.heares.2008.01.010 · Cited by 22
Impedance spectroscopy on stretchable microelectrode arrays
Minev, I. R., & Lacour, S. P. (2010) · Applied Physics Letters · doi:10.1063/1.3469919 · Cited by 20
Artificial speech synthesizer control by brain-computer interface
Brumberg, J. S., Kennedy, P. R., & Guenther, F. H. (2009) · Interspeech (USB) · doi:10.21437/interspeech.2009-225 · Cited by 22
“Standard multiunit extracellular electrodes come in an array (multielectrode array, MEA) configuration with many tens of penetrating tips which are capable of recording one to two neural action potentials, or spikes, per tip [11-14].”
BackgroundThe Pursuit of Chronically Reliable Neural Interfaces: A Materials Perspective
Guo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00599 · Cited by 19
“…far out of reach, primarily due to the discovery of fibrotic encapsulation developing around the implanted neural interface over a short time window of a few months, which physically screens the electrical sensors from accessing to the target neurons (Rousche and Normann, 1998; Jorfi et al., 2015).”
BackgroundInfluentialElectrical performance of penetrating microelectrodes chronically implanted in cat cortex
Kane, S. R., Cogan, S. F., Ehrlich, J., Plante, T. D., & McCreery, D. B. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091339 · Cited by 23
Villalobos, J., Fallon, J. B., Nayagam, D. A. X., Shivdasani, M. N., Luu, C. D., Allen, P. J., Shepherd, R. K., & Williams, C. E. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/4/046017 · Cited by 20
“These Utah intracortical microelectrode arrays are designed for recording in cortex [44].”
BackgroundSilicon carbide neural implants: In vivo neural tissue reaction
Frewin, C. L., Locke, C., Mariusso, L., Weeber, E. J., & Saddow, S. E. (2013) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2013.6696021 · Cited by 23
A Benchtop System to Assess Cortical Neural Interface Micromechanics
Das, R., Gandhi, D., Krishnan, S., Saggere, L., & Rousche, P. J. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897139 · Cited by 23
“tissue [23], [19], [20], [24] and the electrode-tissue interaction”
BackgroundSelf-citationLi, J., Li, R., Chiang, C., Zhong, Y., Shen, H., Song, E., Hill, M., Won, S. M., Yu, K. J., Baek, J. M., et al. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201900800 · Cited by 19
Kim, H., Dingle, A. M., Ness, J. P., Baek, D.-H., Bong, J., Lee, I. K., Shulzhenko, N. O., Zeng, W., Israel, J. S., Pisaniello, J. A., et al. (2020) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2020.108602 · Cited by 19
Zhou, Y., Ji, B., Wang, M., Zhang, K., Huangfu, S., Feng, H., Chang, H., & Yuan, X. (2021) · Coatings · doi:10.3390/coatings11020204 · Cited by 22
Recent progress of electroactive interface in neural engineering
Shan, Y., Cui, X. J., Chen, X., & Li, Z. (2022) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1827 · Cited by 21
Park, H., Shin, H., Cho, I., Yoon, E.-S., Suh, J.-K. F., Im, M., Yoon, E., Kim, Y.-J., & Kim, J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090813 · Cited by 19
Can motor volition be extracted from the spinal cord?
Prasad, A., & Şahin, M. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-41 · Cited by 20
“Rousche PJ, Normann RA: Chronic recording capability of the utah intracortical electrode array in cat sensory cortex.”
BackgroundInfluentialEffective Area and Charge Density of Chondroitin Sulphate Doped PEDOT Modified Electrodes
Harris, A. R., Molino, P. J., Paolini, A. G., & Wallace, G. G. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.03.038 · Cited by 20
“This encapsulation layer increases the distance between the electrode surface and the target tissue, reducing the sensitivity of the device [2].”
Zhang, S., Tsang, W. M., Merugu, S., Sun, T., Singh, N., Kwong, D., & Lee, C. (2014) · Applied Physics Letters · doi:10.1063/1.4875961 · Cited by 18
Nanoelectronics enabled chronic multimodal neural platform in a mouse ischemic model
Luan, L., Sullender, C. T., Li, X., Zhao, Z., Zhu, H., Wei, X., Xie, C., & Dunn, A. K. (2017) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2017.12.001 · Cited by 20
“Conventional electrodes generate substantial tissue damage both acutely[37, 38] and chronically[39, 40], resulting in sustained tissue reaction near the implants including continuous leakage of blood-brain barrier, neuronal death and glial scar formation[41–43].”
BackgroundMahajan, S., Hermann, J. K., Bedell, H. W., Sharkins, J. A., Chen, L., Chen, K., Meade, S. M., Smith, C. S., Rayyan, J., Feng, H., et al. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00416 · Cited by 19
Vandekerckhove, B., Missinne, J., Vonck, K. E. J., Bauwens, P., Verplancke, R., Boon, P., Raedt, R., & Vanfleteren, J. (2020) · Micromachines · doi:10.3390/mi12010038 · Cited by 20
“The corresponding scar tissue has been shown to completely encapsulate implanted probes and was in some occasions even able to (partially) push implanted electrodes out of the neural tissue [25,30].”
BackgroundMEMS-Actuated Carbon Fiber Microelectrode for Neural Recording
Zoll, R. S., Schindler, C. B., Massey, T. L., Drew, D., Maharbiz, M. M., & Pister, K. S. J. (2019) · IEEE Transactions on NanoBioscience · doi:10.1109/tnb.2019.2905505 · Cited by 18
“Upon implantation, individual recording sites cannot be independently inserted to unique depths to maximize recorded unit activity on each electrode [5], [6].”
BackgroundBouton, C. E. (2020) · Handbook of clinical neurology · doi:10.1016/b978-0-444-63934-9.00022-6 · Cited by 21
Pollard, A. E., & Barr, R. C. (2005) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01180.2005 · Cited by 18
Chen, K., Forrest, A. M., Burgos, G.-G., & Kozai, T. D. Y. (2024) · Journal of Neural Engineering · doi:10.1088/1741-2552/ad5049 · Cited by 18
“The implantation of Utah arrays induces brain trauma, resulting in neuropathological changes similar to those seen with single-shank microelectrodes, including acute neuroinflammation and a chronic FBR [119–121].”
MethodWang, T., Chen, Y., Wang, Y., Lee, S., Lee, Y., & Dong, J. (2024) · Advanced Sensor Research · doi:10.1002/adsr.202400142 · Cited by 19
Intracortical polyimide electrodes with a bioresorbable coating
Hassler, C., Guy, J., Nietzschmann, M., Plachta, D. T. T., Staiger, J. F., & Stieglitz, T. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0106-7 · Cited by 19
He, F., Sun, Y., Jin, Y., Yin, R., Zhu, H., Rathore, H., Xie, C., & Luan, L. (2022) · Biomaterials · doi:10.1016/j.biomaterials.2022.121905 · Cited by 20
Encoding of forelimb forces by corticospinal tract activity in the rat
Guo, Y., Foulds, R. A., Adamovich, S., & Şahin, M. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00062 · Cited by 18
Initiated chemical vapor deposition of a siloxane coating for insulation of neural probes
O’Shaughnessy, W. S., Edell, D. J., & Gleason, K. K. (2009) · Thin Solid Films · doi:10.1016/j.tsf.2009.01.192 · Cited by 17
Qiao, S., & Yoshida, K. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.04.008 · Cited by 18
“during chronic animal testing using intrafascicular electrodes [1–4] or intracortical microelectrodes [5,6], extracellularly recorded single units tend to change amplitude and shape over time.”
BackgroundA Robotic Neural Interface for Autonomous Positioning of Extracellular Recording Electrodes
Wolf, M. T., Cham, J. G., Branchaud, E. A., Mulliken, G. H., Burdick, J. W., & Andersen, R. A. (2009) · The International Journal of Robotics Research · doi:10.1177/0278364908103788 · Cited by 20
“…which typically consist of fixed geometry bundles of thin wires or arrays of silicon probes, are surgically implanted in the region of interest (Rousche and Normann 1998 Williams et al. 1999 Porada et al. 2000) (see Figure 1B) and remain in place for weeks, months, or possibly years at a time.”
Planar 2D-Array Neural Probe for Deep Brain Stimulation and Recording (DBSR)
Musa, S., Welkenhuysen, M., Huys, R., Eberle, W., van Kuyck, K., Bartic, C., Nuttin, B., & Borghs, G. (2009) · World Congress on Medical Physics and Biomedical Engineering, September 7 - 12, 2009, Munich, Germany · doi:10.1007/978-3-540-89208-3_581 · Cited by 18
Silicon Carbide Materials for Biomedical Applications
Frewin, C. L., Coletti, C., Register, J., Nezafati, M., Thomas, S. W., & Saddow, S. E. (2014) · Springer eBooks · doi:10.1007/978-3-319-08648-4_7 · Cited by 20
“other neural probe device researchers [54, 132, 136].”
Troyk, P. R., & Cogan, S. F. (2007) · Springer eBooks · doi:10.1007/0-306-48610-5_1 · Cited by 18
An Algorithm for Autonomous Isolation of Neurons in Extracellular Recordings
Branchaud, E. A., Burdick, J. W., & Andersen, R. A. (2006) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2006.1639212 · Cited by 17
“blies, which are typically bundles or arrays of thin wires or silicon probes, are surgically implanted in the region of interest [5]–[7].”
BackgroundFlexible neural recording electrodes based on reduced graphene oxide interfaces
Dong, M., Chen, P., Zhou, K., Marroquin, J. B., Liu, M., Thomas, S., Coleman, H. A., Li, D., Fallon, J. B., Majumder, M., et al. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.147067 · Cited by 16
Jiang, J., Willett, F. R., & Taylor, D. M. (2014) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2014.6944265 · Cited by 20
Amorphous Silicon Carbide for Neural Interface Applications
Knaack, G. L., Charkhkar, H., Cogan, S. F., & Pancrazio, J. J. (2016) · Elsevier eBooks · doi:10.1016/b978-0-12-802993-0.00008-3 · Cited by 19
Chronic co-implantation of ultraflexible neural electrodes and a cranial window
Yin, R., Noble, B. C., He, F., Zolotavin, P., Rathore, H., Jin, Y., Sevilla, N., Xie, C., & Luan, L. (2022) · Neurophotonics · doi:10.1117/1.nph.9.3.032204 · Cited by 17
Wark, H. A. C., Black, S. R., Mathews, K., Cartwright, P. C., Gustafson, K. J., & Normann, R. A. (2014) · Neuromodulation Technology at the Neural Interface · doi:10.1111/ner.12259 · Cited by 16
Self-citationPhotochemical coating of Kapton® with hydrophilic polymers for the improvement of neural implants
Hadler, C., Wissel, K., Brandes, G., Dempwolf, W., Reuter, G., Lenarz, T., & Menzel, H. (2017) · Materials Science and Engineering C · doi:10.1016/j.msec.2017.02.020 · Cited by 17
Designing a Brain-Machine Interface for Neuroprosthetic Control
Moxon, K. A. (2000) · doi:10.1201/9781420039054-13 · Cited by 17
Wireless interfaces for brain neurotechnologies
Kim, H., & Ho, J. S. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0020 · Cited by 18
Biomaterial‐Based Fibrous Implantable Probes for Tissue‐Electronics Interface
Xu, M., Lin, Z., Tong, X., Yang, D., & Shao, Y. (2025) · Advanced Materials · doi:10.1002/adma.202504372 · Cited by 22
Neural interface with a silicon neural probe in the advancement of microtechnology
Oh, S., Song, J. K., & Kim, S. J. (2003) · Biotechnology and Bioprocess Engineering · doi:10.1007/bf02942274 · Cited by 18
Multielectrode and Multitransistor Arrays for In Vivo Recording
Vassanelli, S. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_8 · Cited by 16
Gutruf, P., Good, C. H., & Rogers, J. A. (2018) · APL Photonics · doi:10.1063/1.5040256 · Cited by 15
Hassarati, R. T., Marçal, H., John, L., Foster, R., & Green, R. A. (2015) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.33497 · Cited by 16
Zhao, Z., Gong, R., Huang, H., & Wang, J. (2016) · Sensors · doi:10.3390/s16060880 · Cited by 16
Active Pixel Sensor Multielectrode Array for High Spatiotemporal Resolution
Berdondini, L., Bosca, A., Nieus, T. R., & Maccione, A. (2014) · Springer eBooks · doi:10.1007/978-1-4899-8038-0_7 · Cited by 18
Flexible kirigami microelectrode arrays for neuronal activity recordings in non-human primate brains
FANG, R., Tian, H., Du, Y., Zhao, Y., Yang, Y., Guan, S., Li, S., Liu, M., Xu, K., & Fang, Y. W. (2026) · Nature Electronics · doi:10.1038/s41928-025-01560-6 · Cited by 17
Resorbable conductive materials for optimally interfacing medical devices with the living
Sacchi, M., Sauter-Starace, F., Mailley, P., & Texier, I. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1294238 · Cited by 15
“The fi rst electrode arrays cleared by the FDA were the renowned Utah array (Rousche et al., 1998).”
BackgroundMueller, N. N., Ocoko, M. Y. M., Kim, Y., Li, K., Gisser, K., Glusauskas, G., Lugo, I., Dernelle, P., Hermoso, A. C., Wang, J., et al. (2025) · npj Flexible Electronics · doi:10.1038/s41528-025-00440-5 · Cited by 15
Investigation of a New Electrode Array Technology for a Central Auditory Prosthesis
Calixto, R., Salamat, B., Rode, T., Hartmann, T., Volckaerts, B., Ruther, P., Lenarz, T., & Lim, H. H. (2013) · PLoS ONE · doi:10.1371/journal.pone.0082148 · Cited by 14
Three-micrometer-diameter needle electrode with an amplifier for extracellular in vivo recordings
Kita, Y., Tsuruhara, S., Kubo, H., Yamashita, K., Seikoba, Y., Idogawa, S., Sawahata, H., Yamagiwa, S., Leong, X. L. A., Numano, R., et al. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2008233118 · Cited by 14
“A wafer-dicing–based fabrication process produces the other type, a three-dimensional ∼80-μm -diameter needle array, called the “Utah array” (5, 6), which demonstrates the brain–machine interface (7, 8).”
MethodParalikar, K. J., Lawrence, J. K., & Clement, R. S. (2006) · Conference proceedings · doi:10.1109/iembs.2006.260302 · Cited by 15
“Varied solutions are available: bundles of microwires [1, 2], micro-machined tines of silicon [ 3 ], and planar multi-site/shank structures [4].”
BackgroundThe development of a PZT-based microdrive for neural signal recording
Park, S.-K., Yoon, E.-S., Lee, S., Shin, H., Park, H., Kim, B., Kim, D., Park, J., & Park, S. (2008) · Smart Materials and Structures · doi:10.1088/0964-1726/17/2/027001 · Cited by 14
“It is surgically implanted to the brain region of interest (Porada et al 2000, Rousche and Normann 1998, Williams et al 1999).”
MethodWellman, S. M., Forrest, A. M., Douglas, M. M., Subbaraman, A., Zhang, G., & Kozai, T. D. Y. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2024.122963 · Cited by 14
Bellicha, A., Struber, L., Pasteau, F., Juillard, V., Devigne, L., Karakas, S., Chabardès, S., Babel, M., & Charvet, G. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/adae36 · Cited by 14
“While the use of microelectrodes arrays allow precise control over a high number of DoF, a long-term use is usually impossible given the stability of signals and models that require regular updates and because electrodes become unusable after a short period of time [9].”
Cheng, C., Kmech, J., Mushahwar, V. K., & Elias, A. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2241061 · Cited by 13
“These have been implanted in cat ventral cochlear cells for the restoration of hearing [17], in various regions of the cerebral cortex [8], [18], [29], in cat spinal cords for short-term restoration of bladder control (less than 150 days) [16], and in peripheral nerves [30], [31].”
In Vivo Measurements With Robust Silicon-Based Multielectrode Arrays With Extreme Shaft Lengths
Márton, G., Fekete, Z., Fiáth, R., Baracskay, P., Ulbert, I., Juhász, G. D., Battistig, G., & Pongracz, A. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2260325 · Cited by 14
“larger brain, such as cats [6] or primates [7], silicon-based”
BackgroundImplantable and wearable sensors
Zhang, J. X. J., & Hoshino, K. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-814862-4.00008-9 · Cited by 17
Jabbari, M., & Erfanian, A. (2019) · Scientific Reports · doi:10.1038/s41598-019-54144-8 · Cited by 13
Lu, H., Cho, S., Lee, J., Cauller, L., Romero‐Ortega, M. I., & Hughes, G. A. (2006) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/icsens.2007.355719 · Cited by 15
A Flexible Base Electrode Array for Intraspinal Microstimulation
Khaled, I., Elmallah, S., Cheng, C., Moussa, W. A., Mushahwar, V. K., & Elias, A. L. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2265877 · Cited by 15
“Most of the currently available arrays are rigid and have been developed to interface with the brain [11]–[14], [31].”
BackgroundA High-Yield Fabrication Process for Silicon Neural Probes
Oh, S., Song, J. K., Kim, J., & Kim, S. J. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.862568 · Cited by 14
Effective area and charge density of dextran sulphate doped PEDOT modified electrodes
Harris, A. R., Molino, P. J., Kapsa, R. M. I., Clark, G. M., Paolini, A. G., & Wallace, G. G. (2016) · Synthetic Metals · doi:10.1016/j.synthmet.2016.07.010 · Cited by 13
“This encapsulation layer increases the distance between the electrode surface and the target tissue, reducing the sensitivity of the device [2].”
BackgroundImplantable and Flexible Electronics for In vivo Brain Activity Recordings
Wang, J., Tian, H., & Fang, Y. Z. (2019) · Chinese Journal of Analytical Chemistry · doi:10.1016/s1872-2040(19)61192-8 · Cited by 13
Metadata
- Authors
- Rousche, P. J., & Normann, R. A.
- Affiliations
- University of Manchester (GB)
- University of Utah (US)
- Corresponding author
- Normann, Richard A
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 82
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2142255743
- Semantic Scholar
- fd92cba70ad981a178a97e332f6c03cda18c0e4a
- Cited by
- 646
- References
- 31
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 17 · 2023: 18 · 2022: 28 · 2021: 21 · 2020: 31 · 2019: 34 · 2018: 34 · 2017: 36 · 2016: 35 · 2015: 26 · 2014: 51 · 2013: 47 · 2012: 22
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- W. M. Keck Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- chronic neural recording, silicon microelectrodes, sensory cortex, cats, astroglial response, fibrous encapsulation, electrode implantation
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Electrodes, Implanted, Microelectrodes, Somatosensory Cortex, Utah, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.