Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
The DOI matches its Crossref record; 28 of the 31 references it cites were found in a registry or an index.
Abstract
The Utah Intracortical Electrode Array (UIEA) is an array of 100 penetrating silicon microelectrodes designed to focally electrically stimulate or record neurons residing in a single layer up to 1.5 mm beneath the surface of the cerebral cortex. Apart from its use as a unique tool to study parallel processing in the central nervous system, this array could form the platform for a cortical neuroprosthetic system. Although the UIEA has been used extensively in acute neural recording and stimulation experiments, its long-term performance in a chronic application has yet to be demonstrated. As an initial investigation into the feasibility of long-term cortical recording with an array of microelectrodes, we have hard-wired a subset of 11 electrodes of the UIEA to a percutaneous connector. This chronic UIEA assembly was then implanted into the cerebral cortices of ten cats for durations ranging from 2 to 13 months; over which time, both random and stimulus-evoked single and multiple unit action potentials were periodically recorded. On average, after a 6-month implant period, 60% of implanted arrays could still record some type of activity. Post-sacrifice dissections revealed a fibrous encapsulation of the UIEA. Although most implanted cortex was histologically normal, evidence of a chronic astroglial response was seen in a few cases. The results of the reported experiments indicate that the UIEA can be successfully used for limited times in a chronic recording application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional BMIs with probe-like morphology for LFP recordings are generally small and rigid.[338]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [338]
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationRepresentation of cochlea within primary auditory cortex in the cat
Merzenich, M. M., Knight, P. L., & Roth, G. L. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.231 · Cited by 637
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationA method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationA driveable bundle of microwires for collecting single-unit data from freely-moving rats
Kubie, J. L. (1984) · Physiology & Behavior · doi:10.1016/0031-9384(84)90080-5 · Cited by 184
Research works printed but not linked: 2
- DeYoe EA. An Investigation in the Awake Macaque of the Threshold for Detection of Electrical Currents Applied to Striate Cortex: Psychophysical Properties and Laminar Differences. Ph.D. Thesis, University of Rochester, 1983.
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
Cited by
Items 101–200 of 662
Single-trial decoding of movement intentions using functional ultrasound neuroimaging
Norman, S. L., Maresca, D., Christopoulos, V. N., Griggs, W. S., Demené, C., Tanter, M., Shapiro, M. G., & Andersen, R. A. (2021) · Neuron · doi:10.1016/j.neuron.2021.03.003 · Cited by 136
The Development of Brain-Machine Interface Neuroprosthetic Devices
Patil, P. G., & Turner, D. A. (2008) · Neurotherapeutics · doi:10.1016/j.nurt.2007.11.002 · Cited by 140
Advances in nanowire bioelectronics
Zhou, W., Dai, X., & Lieber, C. M. (2017) · Reports on Progress in Physics · doi:10.1088/0034-4885/80/1/016701 · Cited by 117
Thin films and microelectrode arrays for neuroprosthetics
Ordonez, J., Schuettler, M., Boehler, C., Boretius, T., & Stieglitz, T. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.117 · Cited by 118
Jensen, W., Yoshida, K., & Hofmann, U. G. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.872824 · Cited by 114
“, been demonstrated in the cat sensory cortex [17], [18].”
BackgroundToward a self-deploying shape memory polymer neuronal electrode
Sharp, A. A., Panchawagh, H. V., Ortega, A., Artale, R., Richardson-Burns, S., Finch, D. S., Gall, K., Mahajan, R. L., & Restrepo, D. (2006) · Journal of Neural Engineering · doi:10.1088/1741-2560/3/4/l02 · Cited by 113
Steady or changing? Long-term monitoring of neuronal population activity
Lütcke, H., Margolis, D. J., & Helmchen, F. (2013) · Trends in Neurosciences · doi:10.1016/j.tins.2013.03.008 · Cited by 126
Bridging the divide between neuroprosthetic design, tissue engineering and neurobiology
Leach, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/neuro.16.018.2009 · Cited by 112
“The signal attenuation of implanted neuroelectrodes in chronic settings occurs primarily due to the biological response of host brain tissue to implanted foreign material, i.e., reactive gliosis (Rousche and Normann, 1998; Liu et al., 1999; Nicolelis et al., 2003; see Polikov”
Dexamethasone retrodialysis attenuates microglial response to implanted probes in vivo
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.02.013 · Cited by 107
“Understanding the specific contribution of artery and vein injury on electrophysiology recording performance and sensitivity of electrochemical sensors over time may also be a key step in understanding the larger inter-animal and intra-animal variability often reported in the literature [30, 106, 107].”
The sinusoidal probe: a new approach to improve electrode longevity
Sohal, H. S., Jackson, A., Jackson, R., Clowry, G. J., Vassilevski, K., O’Neill, A., & Baker, S. N. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00010 · Cited by 106
“Chronic recordings have also been obtained from other probes, such as the Utah array (>1–2 years; Rousche and Normann, 1998; Suner et al., 2005; Hochberg et al., 2006, 2012; Simeral et al., 2011; Collinger et al., 2012), Michigan probe (>6 weeks; Kipke et al., 2003; Vetter et al., 2004) and…”
Minnikanti, S., Diao, G., Pancrazio, J. J., Xie, X., Rieth, L. W., Solzbacher, F., & Peixoto, N. (2013) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.10.031 · Cited by 114
“UEAs comprise a bed of electrically isolated conductive silicon needles.”
BackgroundParallel, minimally-invasive implantation of ultra-flexible neural electrode arrays
Zhao, Z., Li, X., He, F., Wei, X., Lin, S. Q., & Xie, C. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab05b6 · Cited by 110
In vitro model of glial scarring around neuroelectrodes chronically implanted in the CNS
Polikov, V. S., Block, M. L., Fellous, J., Hong, J., & Reichert, W. M. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2006.06.018 · Cited by 120
“This variability may be a cause of concern in developing a reproducible in vitro model, however the in vivo response has been shown to be just as variable, if not more variable [16] [17] [34].”
BackgroundDevelopment of a cortical visual neuroprosthesis for the blind: the relevance of neuroplasticity
Fernández, E., Pelayo, F., Romero, S., Bongard, M., Marin, C., Alfaro, A., & Merabet, L. (2005) · Journal of Neural Engineering · doi:10.1088/1741-2560/2/4/r01 · Cited by 105
A technique to prevent dural adhesions to chronically implanted microelectrode arrays
Maynard, E. M., Fernández, E., & Normann, R. A. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00159-x · Cited by 114
Self-citationRecent advances in silicon-based neural microelectrodes and microsystems: a review
Fekete, Z. (2015) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2015.03.055 · Cited by 111
The density difference between tissue and neural probes is a key factor for glial scarring
Lind, G., Linsmeier, C. E., & Schouenborg, J. (2013) · Scientific Reports · doi:10.1038/srep02942 · Cited by 102
Lind, G., Linsmeier, C. E., Thelin, J., & Schouenborg, J. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/4/046005 · Cited by 98
Nanotechnology approaches for the regeneration and neuroprotection of the central nervous system
Silva, G. A. (2005) · Surgical Neurology · doi:10.1016/j.surneu.2004.06.008 · Cited by 112
Ultraflexible Neural Electrodes for Long-Lasting Intracortical Recording
He, F., Lycke, R., Ganji, M., Xie, C., & Luan, L. (2020) · iScience · doi:10.1016/j.isci.2020.101387 · Cited by 105
“…et al., 2015; Kim et al., 2013a; Noh et al., 2004; Weltman et al., 2016; Xu et al., 2018), polyimide (Jeon et al., 2014; Mercanzini et al., 2008; Rousche et al., 2001), and SU-8 (Robin et al., 2014; Xu et al., 2016), with a Young’s modulus of only a few GPa, were used as the substrates for…”
MethodInfluentialNovel Modifications to Carbon-Based Electrodes to Improve the Electrochemical Detection of Dopamine
Jiang, L., Nelson, G. W., Abda, J., & Foord, J. S. (2016) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.6b03879 · Cited by 105
Recent advances in neural electrode–tissue interfaces
Woeppel, K., Yang, Q., & Cui, X. T. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.003 · Cited by 99
Davis, T. S., Parker, R. A., House, P. A., Bagley, E., Wendelken, S., Normann, R. A., & Greger, B. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/6/065003 · Cited by 91
“They have been successfully implanted in the motor cortex [16–19], the auditory cortex [20, 21], the auditory nerve [22, 23], the sciatic nerve [24], and the visual cortex [25, 26] of various animal models.”
Self-citationCham, J. G., Branchaud, E. A., Nenadic, Z., Greger, B., Andersen, R. A., & Burdick, J. W. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00369.2004 · Cited by 97
Electrical Performance of Penetrating Microelectrodes Chronically Implanted in Cat Cortex
Kane, S. R., Cogan, S. F., Ehrlich, J., Plante, T. D., McCreery, D. B., & Troyk, P. R. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2248152 · Cited by 95
“observed by Rousche and Normann, which they also attributed to degradation of the insulating material [23].”
Electrode materials for brain–machine interface: A review
Wu, N., Wan, S., Su, S., Huang, H., Dou, G., & Sun, L. (2021) · InfoMat · doi:10.1002/inf2.12234 · Cited by 100
Degenhart, A. D., Eles, J., Dum, R., Mischel, J. L., Smalianchuk, I., Endler, B., Ashmore, R. C., Tyler-Kabara, E. C., Hatsopoulos, N. G., Wang, W., et al. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/4/046019 · Cited by 94
Widge, A. S., Jeffries‐EL, M., Cui, X. T., Lagenaur, C. F., & Matsuoka, Y. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.08.011 · Cited by 104
Leung, B. K., Biran, R., Underwood, C. J., & Tresco, P. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.03.045 · Cited by 89
House, P. A., MacDonald, J. D., Tresco, P. A., & Normann, R. A. (2006) · Neurosurgical Focus · doi:10.3171/foc.2006.20.5.5 · Cited by 89
Self-citationXie, X., Rieth, L. W., Caldwell, R., Negi, S., Bhandari, R., Sharma, R., Tathireddy, P., & Solzbacher, F. (2015) · Biomedical Microdevices · doi:10.1007/s10544-014-9904-y · Cited by 91
“One representative example of this technology is the Utah electrode array (UEA), which is well developed and has FDA-clearance through an Investigation Device Exemption (IDE) and is able to record single unit signals (Normann 2007; Rousche and Normann 1998; Branner et al. 1999; Ledbetter et al. 2013).”
MethodExplant Analysis of Utah Electrode Arrays Implanted in Human Cortex for Brain-Computer-Interfaces
Woeppel, K., Hughes, C., Herrera, A. J., Eles, J. R., Tyler-Kabara, E. C., Gaunt, R. A., Collinger, J. L., & Cui, X. T. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.759711 · Cited by 90
“Longer experimental times increase the chance of meningeal undergrowth and eventual ejection of the recording device from the host tissues (Rousche and Normann, 1998; Barrese et al., 2016; Degenhart et al., 2016).”
BackgroundTorab, K., Davis, T. S., Warren, D. J., House, P. A., Normann, R. A., & Greger, B. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/3/035001 · Cited by 90
“This drop has also been reported by others [22, 24, 44].”
BackgroundResultSelf-citationInjectable Biomedical Devices for Sensing and Stimulating Internal Body Organs
Jung, Y. H., Kim, J. U., Lee, J. S., Shin, J. H., Jung, W., Ok, J., & Kim, T. (2020) · Advanced Materials · doi:10.1002/adma.201907478 · Cited by 87
Elastomeric and soft conducting microwires for implantable neural interfaces
Kolarcik, C. L., Luebben, S. D., Sapp, S. A., Hanner, J., Snyder, N., Kozai, T. D. Y., Chang, E., Nabity, J. A., Nabity, S. T., Lagenaur, C. F., et al. (2015) · Soft Matter · doi:10.1039/c5sm00174a · Cited by 88
Two-photon imaging of chronically implanted neural electrodes: Sealing methods and new insights
Kozai, T. D. Y., Eles, J. R., Vazquez, A. L., & Cui, X. T. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.10.007 · Cited by 91
Amorphous silicon carbide ultramicroelectrode arrays for neural stimulation and recording
Deku, F., Cohen, Y., Joshi-Imre, A., Kanneganti, A., Gardner, T. J., & Cogan, S. F. (2018) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa8f8b · Cited by 89
Bioinspired Materials for In Vivo Bioelectronic Neural Interfaces
Woods, G. A., Rommelfanger, N. J., & Hong, G. (2020) · Matter · doi:10.1016/j.matt.2020.08.002 · Cited by 91
Tissue-Compliant Neural Implants from Microfabricated Carbon Nanotube Multilayer Composite
Zhang, H., Patel, P. R., Xie, Z., Swanson, S. D., Wang, X., & Kotov, N. A. (2013) · ACS Nano · doi:10.1021/nn402074y · Cited by 87
Cody, P. A., Eles, J. R., Lagenaur, C. F., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.01.025 · Cited by 87
Brain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations
Slutzky, M. W. (2019) · The Neuroscientist · doi:10.1177/1073858418775355 · Cited by 81
Rothschild, R. M. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00112 · Cited by 84
Evaluation of the stability of intracortical microelectrode arrays
Liu, X., McCreery, D. B., Bullara, L. A., & Agnew, W. F. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.870495 · Cited by 84
“implantation techniques have also made it possible for the implanted microelectrodes to achieve a long-term interface with the neural tissue [7]–[12].”
BackgroundFunctional aqueous droplet networks
Booth, M. J., Restrepo Schild, V., Downs, F. G., & Bayley, H. (2017) · Molecular BioSystems · doi:10.1039/c7mb00192d · Cited by 85
Statistical Encoding Model for a Primary Motor Cortical Brain-Machine Interface
Shoham, S., Paninski, L., Fellows, M. R., Hatsopoulos, N. G., Donoghue, J. P., & Normann, R. A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.847542 · Cited by 90
“A number of long-term studies have established the chronic recording capability of this electrode-array [22], [23], and an ongoing research effort is underway to establish its efficacy in an implantable brain-machine interface [14], [24].”
BackgroundSelf-citationAgorelius, J., Tsanakalis, F., Friberg, A., Thorbergsson, P. T., Pettersson, L. M. E., & Schouenborg, J. (2015) · Frontiers in Neuroscience · doi:10.3389/fnins.2015.00331 · Cited by 93
“Moreover, the quality, i.e., signal-to-noise ratio, commonly gradually deteriorates over time (Rousche and Normann, 1998; Williams et al., 1999; Polikov et al., 2005).”
BackgroundProgress in conducting polymers for biointerfacing and biorecognition applications
Maziz, A., Özgür, E., Bergaud, C., & Uzun, L. (2021) · Sensors and Actuators Reports · doi:10.1016/j.snr.2021.100035 · Cited by 94
Lee, W., Jeong, S., Lim, Y., Lee, H., Kang, J., Lee, H., Lee, I., Han, H., Kobayashi, S., Tanaka, M., et al. (2021) · Science Advances · doi:10.1126/sciadv.abi6290 · Cited by 87
“The earliest microneedles realized on silicon chips (called Utah arrays) penetrated the brain to obtain bioelectrical signals from deep sites for surgery (7, 8).”
BackgroundThe Evolution of Neuroprosthetic Interfaces
Adewole, D. O., Serruya, M. D., Harris, J. P., Burrell, J. C., Petrov, D., Chen, H.-C. I., Wolf, J. A., & Cullen, D. K. (2016) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2016017198 · Cited by 92
Eles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.04.043 · Cited by 93
“Neuron loss within the effective recording distance of electrode devices (electrode sites can resolve single neuron activity within 50-140μm [14–16]) is thought to lead to progressive failure of a device’s recording quality in rodent [17, 18], cat[19], and primate models [20, 21].”
BackgroundFuture of Seizure Prediction and Intervention: Closing the Loop
Nagaraj, V., Lee, S. T., Krook-Magnuson, E., Soltesz, I., Benquet, P., Irazoqui, P. P., & Netoff, T. I. (2015) · Journal of Clinical Neurophysiology · doi:10.1097/wnp.0000000000000139 · Cited by 80
“Furthermore, individual channels within microelectrode arrays do not stably record from the same neurons during the viable window (Rennaker et al., 2005; Rousche and Normann, 1998).”
Interim Safety Profile From the Feasibility Study of the BrainGate Neural Interface System
Rubin, D. B., Ajiboye, A. B., Barefoot, L., Bowker, M., Cash, S. S., Chen, D., Donoghue, J. P., Eskandar, E. N., Friehs, G., Grant, C., et al. (2023) · Neurology · doi:10.1212/wnl.0000000000201707 · Cited by 81
Physiological Challenges for Intracortical Electrodes
Groothuis, J., Ramsey, N. F., Ramakers, G. M. J., & Plasse, G. (2013) · Brain stimulation · doi:10.1016/j.brs.2013.07.001 · Cited by 86
“Encapsulation of an implanted array of electrodes through formation of a glial sheath leads to recording inconsistencies, as the sheath can move an entire array [28].”
InfluentialScalable batch fabrication of ultrathin flexible neural probes using a bioresorbable silk layer
Cointe, C., Laborde, A., Nowak, L. G., Arvanitis, D. N., Bourrier, D., Bergaud, C., & Maziz, A. (2022) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00353-7 · Cited by 78
“and (6) final shaping of the silk-parylene probe by RIE and release from the substrate.”
BackgroundDaily variation and appetitive conditioning‐induced plasticity of auditory cortex receptive fields
Kisley, M. A., & Gerstein, G. L. (2001) · European Journal of Neuroscience · doi:10.1046/j.0953-816x.2001.01568.x · Cited by 78
“1C and D), presumably because of gliosis around the electrode (e.g. Rousche & Normann, 1998; Turner et al., 1999).”
BackgroundSmart Polymers for Neural Interfaces
Ware, T., Simon, D., Rennaker, R. L., & Voit, W. (2013) · Polymer Reviews · doi:10.1080/15583724.2012.751924 · Cited by 73
Using Artificial Skin Devices as Skin Replacements: Insights into Superficial Treatment
Low, Z. W. K., Li, Z., Owh, C., Chee, P. L., Ye, E., Kai, D., Yang, D., & Loh, X. J. (2019) · Small · doi:10.1002/smll.201805453 · Cited by 77
In vivo evaluation of a neural stem cell-seeded prosthesis
Purcell, E. K., Seymour, J. P., Yandamuri, S., & Kipke, D. R. (2009) · Journal of Neural Engineering · doi:10.1088/1741-2560/6/2/026005 · Cited by 76
Silva, G. A. (2010) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2009.05361.x · Cited by 84
Seven years of recording from monkey cortex with a chronically implanted multiple microelectrode
Krüger, J. (2010) · Frontiers in Neuroengineering · doi:10.3389/fneng.2010.00006 · Cited by 73
Fujishiro, A., Kaneko, H., Kawashima, T., Ishida, M., & Kawano, T. (2014) · Scientific Reports · doi:10.1038/srep04868 · Cited by 70
Chronically Implanted, Nafion-Coated Ag/AgCl Reference Electrodes for Neurochemical Applications
Hashemi, P., Walsh, P. L., Guillot, T. S., Gras-Najjar, J., Takmakov, P. A., Crews, F. T., & Wightman, R. M. (2011) · ACS Chemical Neuroscience · doi:10.1021/cn2000684 · Cited by 82
Reagentless aptamer based impedance biosensor for monitoring a neuro-inflammatory cytokine PDGF
Liao, W., & Cui, X. T. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.04.004 · Cited by 78
Melatonin improves quality and longevity of chronic neural recording
Golabchi, A., Wu, B., Li, X., Carlisle, D. L., Kozai, T. D. Y., Friedlander, R. M., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.026 · Cited by 82
“Many studies have reported significant SU amplitude decrease over time [9-11], and the degradation in signal quality leads to the drop in single-unit yield over time [9, 12].”
Visual prosthesis: interfacing stimulating electrodes with retinal neurons to restore vision.
Barriga-Rivera, A., Bareket, L., Goding, J., Aregueta-Robles, U. A., & Suaning, G. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00620 · Cited by 73
“Neuronal electrodes are often end up being in contact with a surface sealing glial layer rather than with the neurons, leading to a gradual loss of function (Rousche and Normann, 1998; Maynard et al., 2000).”
BackgroundImpedance Characterization of Microarray Recording Electrodes in Vitro
Merrill, D. R., & Tresco, P. A. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.856245 · Cited by 72
“Rousche and Normann [ 24 ] and Branner et al. [25] reported decreases in impedance after implantation of the Utah Electrode Array, although later investigation indicated that these decreases may have been due to breakdown of the electrode insulation (personal communication from R.A.Normann).”
BackgroundAttaining higher resolution visual prosthetics: a review of the factors and limitations
Eiber, C. D., Lovell, N. H., & Suaning, G. J. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/1/011002 · Cited by 70
“For longer-term implantable recording microelectrodes, biocompatibility and immunity to migration are secondary, non-electrical considerations [98].”
BackgroundO’Shaughnessy, W. S., Murthy, S. K., Edell, D. J., & Gleason, K. K. (2007) · Biomacromolecules · doi:10.1021/bm070242s · Cited by 71
The “sewing machine” for minimally invasive neural recording
Hanson, T. L., Diaz-Botia, C. A., Kharazia, V., Maharbiz, M. M., & Sabes, P. N. (2019) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/578542 · Cited by 66
“damage due to vessel blockage can extend several hundred micrometers beyond an electrode shaft [37], results in hemorrhagic necrosis and edema [38], and this leads to highly variable responses, depending on the particular locations of vasculature along electrode tracts [39].”
BackgroundElectrophysiological recordings from behaving animals—going beyond spikes
Chorev, E., Epsztein, J., Houweling, A. R., Lee, A. K., & Brecht, M. (2009) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2009.08.005 · Cited by 80
“Previously, recording stability across days was claimed on the basis of similarity between action potential waveforms [19,20] or waveform features [21].”
Stability of chronic multichannel neural recordings: Implications for a long-term neural interface
Williams, J. C., Rennaker, R. L., & Kipke, D. R. (1999) · Neurocomputing · doi:10.1016/s0925-2312(99)00106-x · Cited by 69
“, [3,8,9]).”
Bioactive properties of nanostructured porous silicon for enhancing electrode to neuron interfaces
Moxon, K. A., Hallman, S., Aslani, A., Kalkhoran, N. M., & Lelkes, P. I. (2007) · Journal of Biomaterials Science, Polymer Edition · doi:10.1163/156856207782177882 · Cited by 68
Aoyagi, Y., Stein, R. B., Branner, A., Pearson, K. G., & Normann, R. A. (2003) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(03)00143-2 · Cited by 68
“The electrode array was positioned on the L6 and/or L7 DRGs and then inserted through the dura into the DRG with a pneumatic inserter that has been used successfully in cerebral cortex and peripheral nerve (Branner and Normann, 2000; Rousche and Normann, 1992).”
MethodSelf-citationSponheim, C., Papadourakis, V., Collinger, J. L., Downey, J., Weiss, J., Pentousi, L., Elliott, K., & Hatsopoulos, N. G. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3eaf · Cited by 66
Cortical stimulation mapping using epidurally implanted thin-film microelectrode arrays
Molina-Luna, K., Buitrago, M. M., Hertler, B., Schubring-Giese, M., Haiss, F., Nisch, W., Schulz, J. B., & Luft, A. R. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.10.025 · Cited by 74
Brain–computer interfaces: an overview of the hardware to record neural signals from the cortex
Stieglitz, T., Rubehn, B., Henle, C., Kisban, S., Herwik, S., Ruther, P., & Schüettler, M. (2009) · Progress in brain research · doi:10.1016/s0079-6123(09)17521-0 · Cited by 72
“Researchers often report on the loss of single-unit recordings over time (Rousche and Normann, 1998) and propose adaptive systems that allow readjustment of the probes after implantation to be able to get another cortical cell to record from.”
BackgroundInfluence of resveratrol release on the tissue response to mechanically adaptive cortical implants
Nguyen, J. K., Jorfi, M., Buchanan, K. L., Park, D. J., Foster, E. J., Tyler, D. J., Rowan, S. J., Weder, C., & Capadona, J. R. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.11.001 · Cited by 69
“Additionally, the extent of neuroinflammation has been correlated to the proximity of the implant to large vessels [54].”
Klink, P. C., Chen, X., Vanduffel, W., & Roelfsema, P. R. (2021) · eLife · doi:10.7554/elife.67304 · Cited by 63
“We used a 1024-channel cortical implant, consisting of a titanium pedestal that was connected to 16 Utah arrays ( Rousche and Normann, 1998 ).”
Materials and device strategies to enhance spatiotemporal resolution in bioelectronics
Zhang, J., Cheng, Z., Li, P., & Tian, B. (2025) · Nature Reviews Materials · doi:10.1038/s41578-025-00798-y · Cited by 71
“The flexible and biocompatible design helps to mitigate the mismatch between biological tissue and implanted bioelectronics 164–169 , enabling stable long-term recording in rats for over a year 167 or even throughout mouse lifespan 168 .”
Let There Be Light—Optoprobes for Neural Implants
Alt, M. T., Fiedler, E., Rudmann, L., Ordonez, J. S., Ruther, P., & Stieglitz, T. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2016.2577518 · Cited by 68
“Most chronic experiments of silicon-based neural implants included parylene C or polyimide coatings and led to a wide range of reliability from a few months to a few years in vivo [322]–[325].”
BackgroundFlavopiridol reduces the impedance of neural prostheses in vivo without affecting recording quality
Purcell, E. K., Thompson, D. E., Ludwig, K. A., & Kipke, D. R. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.026 · Cited by 62
Lizundia, E., Sarasua, J.-R., D’Angelo, F., Orlacchio, A., Martino, S., Kenny, J. M., & Armentano, I. (2012) · Macromolecular Bioscience · doi:10.1002/mabi.201200008 · Cited by 66
Jeon, M., Cho, J., Kim, Y. K., Jung, D., Yoon, E.-S., Shin, S., & Cho, I.-J. (2014) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/24/2/025010 · Cited by 61
Neural Probes for Chronic Applications
Kook, G., Lee, S., Lee, H., Cho, I., & Lee, H. J. (2016) · Micromachines · doi:10.3390/mi7100179 · Cited by 69
“A study showed that an upper limit for the rigid silicon neural probe for chronic recording was approximately 8–10 months post-implantation as the probes were expelled from the tissue [125].”
BackgroundUltracompliant Hydrogel‐Based Neural Interfaces Fabricated by Aqueous‐Phase Microtransfer Printing
Huang, W., Ong, X. C., Kwon, I. S., Gopinath, C., Fisher, L. E., Wu, H., Fedder, G. K., Gaunt, R. A., & Bettinger, C. J. (2018) · Advanced Functional Materials · doi:10.1002/adfm.201801059 · Cited by 61
Thinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60
Recent innovations in artificial skin
Low, Z. W. K., Li, Z., Owh, C., Chee, P. L., Ye, E., Kai, D., Chan, S. Y., Young, D. J., & Loh, X. J. (2020) · Biomaterials Science · doi:10.1039/c9bm01445d · Cited by 67
Coating flexible probes with an ultra fast degrading polymer to aid in tissue insertion
Lo, M.-C., Wang, S., Singh, S., Damodaran, V. B., Kaplan, H. M., Kohn, J., Shreiber, D. I., & Zahn, J. D. (2015) · Biomedical Microdevices · doi:10.1007/s10544-015-9927-z · Cited by 53
“Despite the feasibility for short term neural recordings (~2–6 weeks) (Rousche and Normann 1998; Williams et al. 1999) from these different types of probes, most of the devices ultimately failed due to disruption of the electrode-cell interface by the foreign body response, which alters the…”
BackgroundGiagka, V., & Serdijn, W. A. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0010-y · Cited by 58
Čvančara, P., Boretius, T., López-Álvarez, V. M., Maciejasz, P., Andreu, D., Raspopovic, S., Petrini, F., Micera, S., Granata, G., Fernandez, E., et al. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab9a9a · Cited by 58
Trends and recent development of the microelectrode arrays (MEAs)
Xu, L., Hu, C., Huang, Q., Jin, K., Zhao, P., Wang, D., Hou, W., Dong, L., Hu, S., & Ma, H. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112854 · Cited by 63
Biomedical Implant Capsule Formation: Lessons Learned and the Road Ahead
DiEgidio, P., Friedman, H. I., Gourdie, R. G., Riley, A. E., Yost, M. J., & Goodwin, R. L. (2014) · Annals of Plastic Surgery · doi:10.1097/sap.0000000000000287 · Cited by 55
“When rigid devices such as electrodes are placed in neuronal tissues, the same processes cause damage and destruction of the neuronal tissue or ultimate failure of function.(3,6,7)”
BackgroundCutrone, A., & Micera, S. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201801345 · Cited by 60
Closed-loop interaction with the cerebral cortex: a review of wireless implant technology
Kohler, F., Gkogkidis, C. A., Bentler, C., Wang, X., Gierthmuehlen, M., Fischer, J., Stolle, C., Reindl, L. M., Rickert, J., Stieglitz, T., et al. (2017) · Brain-Computer Interfaces · doi:10.1080/2326263x.2017.1338011 · Cited by 58
Recent advances in neural interfaces—Materials chemistry to clinical translation
Bettinger, C. J., Ecker, M., Kozai, T. D. Y., Malliaras, G. G., Meng, E. F., & Voit, W. (2020) · MRS Bulletin · doi:10.1557/mrs.2020.195 · Cited by 60
A hybrid silicon–parylene neural probe with locally flexible regions
Kim, E. G. R., John, J. K., Tu, H., Zheng, Q., Loeb, J. A., Zhang, J., & Xu, Y. P. (2014) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2014.01.048 · Cited by 66
Joo, H. R., Fan, J. L., Chen, S., Pebbles, J. A., Liang, H., Chung, J. E., Yorita, A. M., Tooker, A. C., Tolosa, V. M., Geaghan-Breiner, C., et al. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab2b2e · Cited by 54
Engineering strategies towards overcoming bleeding and glial scar formation around neural probes
Otte, E., Vlachos, A., & Asplund, M. (2022) · Cell and Tissue Research · doi:10.1007/s00441-021-03567-9 · Cited by 58
“1991; Rousche and Normann 1998).”
BackgroundFrewin, C. L., Jaroszeski, M. J., Weeber, E. J., Muffly, K. E., Kumar, A., Peters, M. M., Oliveros, A., & Saddow, S. E. (2009) · Journal of Molecular Recognition · doi:10.1002/jmr.966 · Cited by 54
Cochlear Nerve Stimulation with a 3-Dimensional Penetrating Electrode Array
Hillman, T., Badi, A. N., Normann, R. A., Kertesz, T., & Shelton, C. (2003) · Otology & Neurotology · doi:10.1097/00129492-200309000-00013 · Cited by 52
Self-citation
Metadata
- Authors
- Rousche, P. J., & Normann, R. A.
- Affiliations
- University of Manchester (GB)
- University of Utah (US)
- Corresponding author
- Normann, Richard A
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 82
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2142255743
- Semantic Scholar
- fd92cba70ad981a178a97e332f6c03cda18c0e4a
- Cited by
- 646
- References
- 31
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 17 · 2023: 18 · 2022: 28 · 2021: 21 · 2020: 31 · 2019: 34 · 2018: 34 · 2017: 36 · 2016: 35 · 2015: 26 · 2014: 51 · 2013: 47 · 2012: 22
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- W. M. Keck Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- chronic neural recording, silicon microelectrodes, sensory cortex, cats, astroglial response, fibrous encapsulation, electrode implantation
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Electrodes, Implanted, Microelectrodes, Somatosensory Cortex, Utah, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.