Chronic recording capability of the Utah Intracortical Electrode Array in cat sensory cortex
The DOI matches its Crossref record; 28 of the 31 references it cites were found in a registry or an index.
Abstract
The Utah Intracortical Electrode Array (UIEA) is an array of 100 penetrating silicon microelectrodes designed to focally electrically stimulate or record neurons residing in a single layer up to 1.5 mm beneath the surface of the cerebral cortex. Apart from its use as a unique tool to study parallel processing in the central nervous system, this array could form the platform for a cortical neuroprosthetic system. Although the UIEA has been used extensively in acute neural recording and stimulation experiments, its long-term performance in a chronic application has yet to be demonstrated. As an initial investigation into the feasibility of long-term cortical recording with an array of microelectrodes, we have hard-wired a subset of 11 electrodes of the UIEA to a percutaneous connector. This chronic UIEA assembly was then implanted into the cerebral cortices of ten cats for durations ranging from 2 to 13 months; over which time, both random and stimulus-evoked single and multiple unit action potentials were periodically recorded. On average, after a 6-month implant period, 60% of implanted arrays could still record some type of activity. Post-sacrifice dissections revealed a fibrous encapsulation of the UIEA. Although most implanted cortex was histologically normal, evidence of a chronic astroglial response was seen in a few cases. The results of the reported experiments indicate that the UIEA can be successfully used for limited times in a chronic recording application.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Conventional BMIs with probe-like morphology for LFP recordings are generally small and rigid.[338]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [338]
Citations
Cites
The sensations produced by electrical stimulation of the visual cortex
Brindley, G. S., & Lewin, W. S. (1968) · The Journal of Physiology · doi:10.1113/jphysiol.1968.sp008519 · Cited by 1,170
Schmidt, E. M., Bak, M. J., Hambrecht, F. T., Kufta, C. V., O'Rourke, D. K., & Vallabhanath, P. (1996) · Brain · doi:10.1093/brain/119.2.507 · Cited by 672
Maynard, E. M., Nordhausen, C. T., & Normann, R. A. (1997) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/s0013-4694(96)95176-0 · Cited by 640
Self-citationRepresentation of cochlea within primary auditory cortex in the cat
Merzenich, M. M., Knight, P. L., & Roth, G. L. (1975) · Journal of Neurophysiology · doi:10.1152/jn.1975.38.2.231 · Cited by 637
Factors influencing the biocompatibility of insertable silicon microshafts in cerebral cortex
Edell, D. J., Toi, V. V., McNeil, V. M., & Clark, L. D. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141202 · Cited by 479
Dobelle, W. H., & Mladejovsky, M. G. (1974) · The Journal of Physiology · doi:10.1113/jphysiol.1974.sp010766 · Cited by 468
A three-dimensional microelectrode array for chronic neural recording
Hoogerwerf, A. C., & Wise, K. D. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335862 · Cited by 371
A glass/silicon composite intracortical electrode array
Jones, K. E., Campbell, P. K., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368134 · Cited by 354
Self-citationA method for pneumatically inserting an array of penetrating electrodes into cortical tissue
Rousche, P. J., & Normann, R. A. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368133 · Cited by 306
Self-citationA driveable bundle of microwires for collecting single-unit data from freely-moving rats
Kubie, J. L. (1984) · Physiology & Behavior · doi:10.1016/0031-9384(84)90080-5 · Cited by 184
Research works printed but not linked: 2
- DeYoe EA. An Investigation in the Awake Macaque of the Threshold for Detection of Electrical Currents Applied to Striate Cortex: Psychophysical Properties and Laminar Differences. Ph.D. Thesis, University of Rochester, 1983.
- Eichenbaum, 1986, Extracellular neural recording with multichannel microelectrodes, J Electrophysiol Tech, 13, 189
Cited by
Items 201–300 of 662
Making the lifetime connection between brain and machine for restoring and enhancing function
Kennedy, P., Andreasen, D., Bartels, J., Ehirim, P., Mao, H., Velliste, M., Wichmann, T., & Wright, J. (2011) · Progress in Brain Research · doi:10.1016/b978-0-444-53815-4.00020-0 · Cited by 54
“These data were obtained from Rhesus Macaque primary motor cortex using a chronic recording system, the Utah Array (Rousche and Normann, 1998), which Prog Brain Res.”
MethodMcConnell, G. C., Schneider, T. M., Owens, D. J., & Bellamkonda, R. V. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.895373 · Cited by 53
“However, the long-term functionality of MEAs, especially in the recording mode, is compromised by the formation of scar tissue surrounding the devices [ 12 ]‐[16].”
BackgroundKundu, A., McCoy, L., Azim, N., Nguyen, H. T., Didier, C. M., Ausaf, T., Sharma, A. D., Curley, J. L., Moore, M. J., & Rajaraman, S. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c01184 · Cited by 55
In vivo Characterization of Amorphous Silicon Carbide As a Biomaterial for Chronic Neural Interfaces
Knaack, G. L., McHail, D. G., Borda, G., Koo, B., Peixoto, N., Cogan, S. F., Dumas, T. C., & Pancrazio, J. J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00301 · Cited by 49
Khilwani, R., Gilgunn, P. J., Kozai, T. D. Y., Ong, X. C., Korkmaz, E., Gunalan, P. K., Cui, X. T., Fedder, G. K., & Özdoğanlar, O. B. (2016) · Biomedical Microdevices · doi:10.1007/s10544-016-0125-4 · Cited by 56
A wireless subdural-contained brain–computer interface with 65,536 electrodes and 1,024 channels
Jung, T., Zeng, N., Fabbri, J. D., Eichler, G., Li, Z., Zabeh, E., Das, A., Willeke, K. F., Wingel, K., Dubey, A., et al. (2025) · Nature Electronics · doi:10.1038/s41928-025-01509-9 · Cited by 59
“For each frequency band, we computed the grating-triggered average response by aligning the response segments according to the grating onset and obtained the average band-pass-scaled response conditioned on each grating orientation (Supplementary Discussion 10).”
InfluentialA 16-site neural probe integrated with a waveguide for optical stimulation
Cho, I., Baac, H. W., & Yoon, E. (2010) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2010.5442376 · Cited by 51
“31 mW, which is sufficient to optically stimulate neurons [3].”
BackgroundAutotaxin and lysophospholipids in rheumatoid arthritis.
Bourgoin, S. G., & Zhao, C. (2010) · PubMed · Cited by 59
Szymanski, L. J., Kellis, S., Liu, C. Y., Jones, K. T., Andersen, R. A., Commins, D., Lee, B., McCreery, D. B., & Miller, C. A. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac127e · Cited by 46
“Previous studies [11, 13, 34] have established the reliability, safety and efficacy of MEA within the posterior parietal and somatosensory cortices in human and non-human subjects for up to 5 years [2, 5, 10, 27–29, 35–37].”
ResultBrain–Computer Interfaces in the Rehabilitation of Stroke and Neurotrauma
Soekadar, S. R., Birbaumer, N., & Cohen, L. G. (2011) · Springer eBooks · doi:10.1007/978-4-431-54008-3_1 · Cited by 60
Patel, P. R., Welle, E. J., Letner, J. G., Shen, H., Bullard, A. J., Caldwell, C. M., Vega-Medina, A., Richie, J. M., Thayer, H. E., Patil, P. G., et al. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acab86 · Cited by 49
“Many previous studies have examined the formation of a scar around chronically implanted UEAs [44] but few have quantified the effect UEAs have on the nearby neuron population in NHPs [15, 36, 45–47].”
Long-term stability of sensitivity to intracortical microstimulation of somatosensory cortex
Callier, T., Schluter, E. W., Tabot, G. A., Miller, L. E., Tenore, F. V., & Bensmaia, S. J. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/5/056010 · Cited by 48
Distinctive Glial and Neuronal Interfacing on Nanocrystalline Diamond
Bendali, A., Agnès, C., Meffert, S. H., Forster, V., Bongrain, A., Arnault, J., Sahel, J., Offenhäusser, A., Bergonzo, P., & Picaud, S. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0092562 · Cited by 51
“Penetrating electrodes have been used in attempts to resolve this problem, but the glial cells grow around them [7], thereby altering the neuron/electrode interface, leading to a loss of function after a few months [8].”
BackgroundPowering and communicating with mm-size implants
Rabaey, J. M., Mark, M., Chen, D., Sutardja, C., Tang, C., Gowda, S., Wagner, M., & Werthimer, D. (2011) · 2011 Design, Automation & Test in Europe · doi:10.1109/date.2011.5763123 · Cited by 46
“In some applications neural probes of 10s of mm(2) large are used [2]; in others, much smaller systems are desirable to enable chronic recordings by minimizing micromotion in vivo [3].”
BackgroundDeveloping Next-Generation Brain Sensing Technologies—A Review
Robinson, J. T., Xie, C., Pohlmeyer, E. A., Gather, M. C., Kemere, C. T., Kitching, J. E., Malliaras, G. G., Marblestone, A. H., Shepard, K. L., & Stieglitz, T. (2019) · IEEE Sensors Journal · doi:10.1109/jsen.2019.2931159 · Cited by 50
“These chronic deteriorations are manifested in electrical recordings as loss in recording yield, amplitude and fidelity [48][61]–[64], greatly limiting their application in both fundamental and”
BackgroundHarris, A. R., Grayden, D. B., & John, S. E. (2023) · Micromachines · doi:10.3390/mi14040722 · Cited by 50
Harris, A. R., Molino, P. J., Kapsa, R. M. I., Clark, G. M., Paolini, A. G., & Wallace, G. G. (2015) · The Analyst · doi:10.1039/c4an02362e · Cited by 51
Physiological properties of brain-machine interface input signals
Slutzky, M. W., & Flint, R. D. (2017) · Journal of Neurophysiology · doi:10.1152/jn.00070.2017 · Cited by 46
“These signals are obtained with the use of multielectrode arrays, most often either silicon shanks (Rousche and Normann 1998; Subbaroyan et al. 2005) or assembled from metal microwires (Nicolelis et al. 2003; Schwarz et al. 2014).”
BackgroundRousche, P. J., Petersen, R. S., Battiston, S., Giannotta, S., & Diamond, M. E. (1999) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(99)00061-8 · Cited by 51
“Previous studies with this array have been limited by the number of simultaneous recordings or the number of available electrode connections (Nordhausen et al., 1996; Rousche and Normann, 1998).”
InfluentialSelf-citationLee, B., Liu, C. Y., & Apuzzo, M. L. J. (2013) · World Neurosurgery · doi:10.1016/j.wneu.2013.01.078 · Cited by 48
Brain–Machine Interfaces: Basis and Advances
Becedas, J. (2012) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2012.2203301 · Cited by 54
MEMS Needle-type Sensor Array for in Situ Measurements of Dissolved Oxygen and Redox Potential
Lee, J., Seo, Y., Lim, T.-S., Bishop, P. L., & Papautsky, I. (2007) · Environmental Science & Technology · doi:10.1021/es070969o · Cited by 46
Wellman, S. M., Guzman, K., Stieger, K. C., Brink, L. E., Sridhar, S., Dubaniewicz, M. T., Li, L., Cambi, F., & Kozai, T. D. Y. (2020) · Biomaterials · doi:10.1016/j.biomaterials.2020.119842 · Cited by 47
The neural tissue around SU-8 implants: A quantitative in vivo biocompatibility study
Márton, G., Tóth, E. Z., Wittner, L., Fiáth, R., Pinke, D., Orbán, G., Meszéna, D., Pál, I., Győri, E. L., Bereczki, Z., et al. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.110870 · Cited by 46
Structural modifications in chronic microwire electrodes for cortical neuroprosthetics: a case study
Sanchez, J. C., Alba, N., Nishida, T., Batich, C., & Carney, P. R. (2006) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2006.875581 · Cited by 45
Lansink, C. S., Bakker, M. C., Buster, W. H., Lankelma, J. V., van der Blom, R., Westdorp, R., Joosten, R. N. J. M. A., McNaughton, B. L., & Pennartz, C. M. A. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.12.016 · Cited by 49
“…et al., 2005). lternatively, rigid electrode arrays for recording from neocorical regions have been used (e.g. Utah intracortical electrode rray; Rousche and Normann, 1998), as well as rectangular grids ‘warp drives’) containing 144 75 m-diameter, stainless steel lectrodes that could be…”
MethodGao, W., Yan, Z., Zhou, H., Xie, Y., Wang, H., Yang, J., Yu, J., Ni, C., Liu, P., Xie, M., et al. (2025) · Journal of Nanobiotechnology · doi:10.1186/s12951-025-03573-x · Cited by 51
“These devices have been successfully applied to record the neural activities in the cortices of monkeys and cats in the form of electrical signals [31, 32].”
Organic Functionalization of 3C-SiC Surfaces
Schoell, S. J., Sachsenhauser, M., Oliveros, A., Howgate, J., Stutzmann, M., Brandt, M. S., Frewin, C. L., Saddow, S. E., & Sharp, I. D. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am302786n · Cited by 47
Schnitker, J., Adly, N., Seyock, S., Bachmann, B., Yakushenko, A., Wolfrum, B. L., & Offenhäusser, A. (2018) · Advanced Biosystems · doi:10.1002/adbi.201700136 · Cited by 46
Implantation of electronic visual prosthesis for blindness restoration
Jang, J., Kim, H., Song, Y. M., & Park, J. (2019) · Optical Materials Express · doi:10.1364/ome.9.003878 · Cited by 44
Atmaramani, R., Chakraborty, B., Rihani, R. T., Usoro, J. O., Hammack, A., Abbott, J., Nnoromele, P. O., Black, B., Pancrazio, J. J., & Cogan, S. F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.10.040 · Cited by 45
Responses of fibroblasts and glial cells to nanostructured platinum surfaces
Pennisi, C. P., Sevcencu, C., Dolatshahi‐Pirouz, A., Foss, M., Hansen, J. L., Larsen, A. N., Zachar, V., Besenbacher, F., & Yoshida, K. (2009) · Nanotechnology · doi:10.1088/0957-4484/20/38/385103 · Cited by 47
Sharma, G., Annetta, N., Friedenberg, D., Blanco, T., Vasconcelos, D., Shaikhouni, A., Rezai, A. R., & Bouton, C. (2015) · Bioelectronic Medicine · doi:10.15424/bioelectronmed.2015.00010 · Cited by 41
Bjånes, D. A., Kellis, S., Nickl, R., Baker, B., Aflalo, T., Bashford, L., Chivukula, S., Fifer, M. S., Osborn, L. E., Christie, B., et al. (2025) · Acta Biomaterialia · doi:10.1016/j.actbio.2025.02.030 · Cited by 43
“Three human participants with C5-C6 level spinal cord injury were consented and chronically implanted with NeuroPort arrays [1,42,62].”
Wang, C., Brunton, E., Haghgooie, S., Cassells, K., Lowery, A., & Rajan, R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046010 · Cited by 39
Lee, H. C., Gaire, J., Currlin, S., McDermott, M. D., Park, K., & Otto, K. J. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00513 · Cited by 45
“Rousche et al. and Williams et al. showed that a large variability existed even between different shanks within a multi-shank device (Rousche and Normann, 1998; Williams et al., 2007).”
BackgroundEles, J. R., Vazquez, A. L., Kozai, T. D. Y., & Cui, X. T. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.12.031 · Cited by 44
“This may explain findings that meningeal tissue and collagen-I progressively grows around and under the electrode device and can lead to ejection of the device from the cortex [19].”
BackgroundInfluentialFlexible neural interfaces for brain implants—the pursuit of thinness and high density
Araki, T., Bongartz, L. M., Kaiju, T., Takemoto, A., Tsuruta, S., Uemura, T., & Sekitani, T. (2020) · Flexible and Printed Electronics · doi:10.1088/2058-8585/abc3ca · Cited by 43
Diamond-on-Polymer Microelectrode Arrays Fabricated Using a Chemical Release Transfer Process
Hess‐Dunning, A., Sabens, D., Martin, H. B., & Zorman, C. A. (2011) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2011.2159099 · Cited by 42
Brain-Machine Interface Engineering
Sanchez, J. C., & Príncipe, J. C. (2007) · Synthesis lectures on biomedical engineering · doi:10.1007/978-3-031-01621-9 · Cited by 44
The Chemistry of Cyborgs—Interfacing Technical Devices with Organisms
Giselbrecht, S., Rapp, B. E., & Niemeyer, C. M. (2013) · Angewandte Chemie International Edition · doi:10.1002/anie.201307495 · Cited by 42
Kim, T., Branner, A., Gulati, T., & Giszter, S. F. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/045001 · Cited by 44
Overcoming failure: improving acceptance and success of implanted neural interfaces
Dalrymple, A. N., Jones, S. T., Fallon, J. B., Shepherd, R. K., & Weber, D. J. (2025) · Bioelectronic Medicine · doi:10.1186/s42234-025-00168-7 · Cited by 44
Vasudevan, S., Patel, K., & Welle, C. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/14/1/016008 · Cited by 37
Characterizing Longitudinal Changes in the Impedance Spectra of In-Vivo Peripheral Nerve Electrodes
Straka, M., Shafer, B., Vasudevan, S., Welle, C. G., & Rieth, L. W. (2018) · Micromachines · doi:10.3390/mi9110587 · Cited by 41
Semi-Implantable Bioelectronics
Fang, J., Huang, S., Liu, F., He, G., Li, X., Huang, X., Chen, H., & Xie, X. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00818-4 · Cited by 43
A Wireless 32-Channel Implantable Bidirectional Brain Machine Interface
Su, Y., Routhu, S., Moon, K. S., Lee, S., Youm, W., & Öztürk, Y. (2016) · Sensors · doi:10.3390/s16101582 · Cited by 40
“Among different types of MEAs, Utah Array [31] is widely used for its excellent chronic stability.”
BackgroundDirectional information from neuronal ensembles in the primate orofacial sensorimotor cortex
Arce, F. I., Lee, J.-C., Ross, C. F., Sessle, B. J., & Hatsopoulos, N. G. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00144.2013 · Cited by 37
Conducting Polymer Microcups for Organic Bioelectronics and Drug Delivery Applications
Antensteiner, M., Khorrami, M., Fallahianbijan, F., Borhan, A., & Abidian, M. R. (2017) · Advanced Materials · doi:10.1002/adma.201702576 · Cited by 37
Long-Term Sheep Implantation of WIMAGINE®, a Wireless 64-Channel Electrocorticogram Recorder
Sauter-Starace, F., Ratel, D., Cretallaz, C., Foerster, M., Lambert, A., Gaude, C., Costecalde, T., Bonnet, S., Charvet, G., Aksenova, T., et al. (2019) · Frontiers in Neuroscience · doi:10.3389/fnins.2019.00847 · Cited by 30
“Accordingly, the number of usable contacts decreases dramatically with time (Rousche and Normann, 1998).”
BackgroundToward Nontransient Silk Bioelectronics: Engineering Silk Fibroin for Bionic Links
Patil, A. C., Xiong, Z., & Thakor, N. V. (2020) · Small Methods · doi:10.1002/smtd.202000274 · Cited by 39
Lin, C., & Luo, S. (2022) · Langmuir · doi:10.1021/acs.langmuir.2c00448 · Cited by 38
Caldwell, R., Mandal, H., Sharma, R., Solzbacher, F., Tathireddy, P., & Rieth, L. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa69d3 · Cited by 36
Tissue reactions evoked by porous and plane surfaces made out of silicon and titanium
Rosengren, A., Wallman, L., Danielsen, N., Laurell, T., & Bjursten, L. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.991167 · Cited by 41
“and electrodes, has been suggested to be the most important reason for failure in the clinical use of neural interfaces [16].”
BackgroundFrewin, C. L., Locke, C., Saddow, S. E., & Weeber, E. J. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6090582 · Cited by 38
Recent advances in electronic devices for monitoring and modulation of brain
Kwon, Y. W., Jun, Y. S., Park, Y., Jang, J., & Park, J. (2021) · Nano Research · doi:10.1007/s12274-021-3476-y · Cited by 36
Intracortical Microelectrode Array Unit Yield under Chronic Conditions: A Comparative Evaluation
Usoro, J. O., Sturgill, B. S., Musselman, K. C., Capadona, J. R., & Pancrazio, J. J. (2021) · Micromachines · doi:10.3390/mi12080972 · Cited by 36
Demonstration of a Robust All-Silicon-Carbide Intracortical Neural Interface
Bernardin, E. K., Frewin, C. L., Everly, R., Ul‐Hassan, J., & Saddow, S. E. (2018) · Micromachines · doi:10.3390/mi9080412 · Cited by 37
Flexible Micropillar Electrode Arrays for In Vivo Neural Activity Recordings
Du, M., Guan, S., Gao, L., Lv, S., Yang, S., Shi, J., Wang, J., Li, H., & Fang, Y. Z. (2019) · Small · doi:10.1002/smll.201900582 · Cited by 37
Fabrication of Polymer Neural Probes with Sub-cellular Features for Reduced Tissue Encapsulation
Seymour, J. P., & Kipke, D. R. (2006) · 2006 International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2006.260528 · Cited by 35
“An increase in electrical impedance is concomitant with the time course of this reactivity and is therefore believed to be the cause of attenuated and noisy signal recordings [ 6-8 ].”
BackgroundMa, J., Yang, S., Yang, Z.-H., He, Z., & Du, Z. J. (2025) · Sensors · doi:10.3390/s25144412 · Cited by 38
Singh, S., Lo, M.-C., Damodaran, V. B., Kaplan, H. M., Kohn, J., Zahn, J. D., & Shreiber, D. I. (2016) · Sensors · doi:10.3390/s16030330 · Cited by 34
“Reactive astrocytosis persists long-term from shear stresses at the probe–tissue interface, which ultimately leads to glial scarring [11,12].”
BackgroundEpicranial sensory evoked potential recordings for repeated assessment of cortical functions in mice
Troncoso, E., Müller, D., Czellár, S., & Kiss, J. Z. (2000) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(00)00164-3 · Cited by 36
Magnetically Inserted Neural Electrodes: Tissue Response and Functional Lifetime
Dryg, I. D., Ward, M. P., Qing, K. Y., Mei, H., Schaffer, J. E., & Irazoqui, P. P. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2399856 · Cited by 32
Zhang, M., Schwemmer, M. A., Ting, J. E., Majstorovic, C. E., Friedenberg, D. A., Bockbrader, M. A., Jerry Mysiw, W., Rezai, A. R., Annetta, N. V., Bouton, C. E., et al. (2018) · Bioelectronic Medicine · doi:10.1186/s42234-018-0011-x · Cited by 32
Flexible and biocompatible nanopaper-based electrode arrays for neural activity recording
Guo, Y., Fang, Z., Du, M., Yang, L., Shao, L., Zhang, X., Li, L., Shi, J., Tao, J., Wang, J., et al. (2018) · Nano Research · doi:10.1007/s12274-018-2005-0 · Cited by 33
Hess‐Dunning, A., & Tyler, D. J. (2018) · Micromachines · doi:10.3390/mi9110583 · Cited by 33
“The correlation between mechanics and the neural tissue response has led to the development of soft intracortical probes based on polymers with established microfabrication processes, such as polyimide [20,28,29], parylene [30–33], and SU-8 [34–37] polymer-based intracortical probes with much lower Young’s moduli (Epo…”
BackgroundHe, W. J., & Bellamkonda, R. V. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.pt4 · Cited by 34
Polikov, V. S., Su, E. C., Ball, M. A., Hong, J., & Reichert, W. M. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.05.002 · Cited by 33
“Most neural recording arrays fail to record the adequate number of high signal to noise ratio unit potentials necessary to generate a control signal after several weeks to months (Rousche and Normann, 1998;Williams et al., 1999;Liu et al., 1999;Nicolelis et al., 2003;Schwartz, 2004).”
BackgroundKim, D., Richardson-Burns, S. M., Povlich, L. K., Abidian, M. R., Spanninga, S. A., Hendricks, J. L., & Martin, D. (2007) · Frontiers in neuroengineering series/Frontiers in neuroengineering · doi:10.1201/9781420009309.ch7 · Cited by 32
Protein adsorption on materials for recording sites on implantable microelectrodes
Selvakumaran, J., Keddie, J. L., Ewins, D. J., & Hughes, M. P. (2007) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-007-3110-x · Cited by 32
“…array implanted in the motor cortex and surrounding areas can be used to extract motor signals from the brain, and an online computational device could be used to convert these motor signals into output signals that are capable of controlling an artificial limb (Rousche and Norman, 1998).”
MethodLayer-specific parameters of intracortical microstimulation of the somatosensory cortex
Urdaneta, M. E., Kunigk, N. G., Delgado, F., Fried, S. I., & Otto, K. J. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abedde · Cited by 32
“5 mm and an interfacing site at the tip of the electrode [28, 29].”
Patient-Specific Cortical Electrodes for Sulcal and Gyral Implantation
Morris, S., Hirata, M., Sugata, H., Goto, T., Matsushita, K., Yanagisawa, T., Saitoh, Y., Kishima, H., & Yoshimine, T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2329812 · Cited by 34
Understanding the Role of Innate Immunity in the Response to Intracortical Microelectrodes
Hermann, J. K., & Capadona, J. R. (2018) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2018027166 · Cited by 31
Bioinspired flexible electronics for seamless neural interfacing and chronic recording
Li, H., Wang, J., & Fang, Y. Z. (2020) · Nanoscale Advances · doi:10.1039/d0na00323a · Cited by 32
Microelectronic Visual Prostheses
Zhou, D. D., & Greenberg, R. J. (2009) · Biological and medical physics series · doi:10.1007/978-0-387-77261-5_1 · Cited by 31
“Since these early experiments, efforts have been underway to produce penetrating arrays of electrodes that offer the possibility of more closely spaced electrodes and therefore higher resolution cortical devices [10, 61–63].”
BackgroundNano functional neural interfaces
Wang, Y., Zhu, H., Yang, H., Argall, A. D., Luan, L., Xie, C., & Guo, L. (2018) · Nano Research · doi:10.1007/s12274-018-2127-4 · Cited by 31
Dunlap, C. F., Colachis, S. C., Meyers, E., Bockbrader, M. A., & Friedenberg, D. A. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.558987 · Cited by 33
Free‐Standing Nanofilm Electrode Arrays for Long‐Term Stable Neural Interfacings
Gao, L., Wang, J., Zhao, Y., Li, H., Liu, M., Ding, J., Tian, H., Guan, S., & Fang, Y. Z. (2021) · Advanced Materials · doi:10.1002/adma.202107343 · Cited by 30
Bioactive polymer-enabled conformal neural interface and its application strategies
Hu, Z., Niu, Q., Hsiao, B. S., Yao, X., & Zhang, Y. (2023) · Materials Horizons · doi:10.1039/d2mh01125e · Cited by 30
Carbon‐Nanotube‐Modified Electrodes for Highly Efficient Acute Neural Recording
Shin, J. H., Kim, G. B., Lee, E. J., An, T., Shin, K., Lee, S. E., Choi, W., Lee, S., Latchoumane, C.-F. V., Shin, H., et al. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201300183 · Cited by 31
Gellan gum doped polypyrrole neural prosthetic electrode coatings
Higgins, T. M., Moulton, S. E., Gilmore, K. J., Wallace, G. G., & Panhuis, M. I. H. (2011) · Soft Matter · doi:10.1039/c1sm05063j · Cited by 30
Lewitus, D. Y., Vogelstein, R. J., Zhen, G., Choi, Y.-S., Kohn, J., Harshbarger, S. D., & Jia, X. (2010) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2010.2098047 · Cited by 32
“Peripheral nervous system (PNS) interfaces for neural prosthetics provide a reasonable compromise between highly invasive cortical implants [7], [ 8 ] and noninvasive control schemes such as those relying on electromyography (EMG) [9], [10]: they achieve higher signal selectivity than EMG but do not provide access to…”
BackgroundStatistical Signal Processing and the Motor Cortex
Brockwell, A., Kass, R. E., & Schwartz, A. B. (2007) · Proceedings of the IEEE · doi:10.1109/jproc.2007.894703 · Cited by 31
Lifetime engineering of bioelectronic implants with mechanically reliable thin film encapsulations
Niemiec, M., & Kim, K. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ad0b19 · Cited by 32
“…were included in the analysis, for which the supporting data can be found in supplementary data table 2 [12, 17, 30, 90, 94, 96, 97, 101, 114, 115, 121, 131, 136, 142, 153, 168, 170, 223, 241, 242, 244, 331, 379, 389, 390, 393, 394, We encourage interested readers to perform their own…”
Neural Interfaces for Upper-Limb Prosthesis Control: Opportunities to Improve Long-Term Reliability
Judy, J. W. (2012) · IEEE Pulse · doi:10.1109/mpul.2011.2181026 · Cited by 29
“Leading probe-array technologies [5]–[7] were advanced in the 2000s by commercialization efforts that are still ongoing.”
From Neurons to Cognition: Technologies for Precise Recording of Neural Activity Underlying Behavior
Roth, R. H., & Ding, J. (2020) · BME Frontiers · doi:10.34133/2020/7190517 · Cited by 30
“A variation of these silicon probes are Utah arrays that consist of a 10-by-10 array of needle-like silicon electrodes [125, 126].”
BackgroundState-space decoding of primary afferent neuron firing rates
Wagenaar, J., Ventura, V., & Weber, D. J. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/1/016002 · Cited by 30
Soft tissue reactions evoked by implanted gallium phosphide
Linsmeier, C. E., Wallman, L., Faxius, L., Schouenborg, J., Bjursten, L. M., & Danielsen, N. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.08.028 · Cited by 30
Mechanically Stable Intraspinal Microstimulation Implants for Human Translation
Toossi, A., Everaert, D. G., Azar, A., Dennison, C. R., & Mushahwar, V. K. (2016) · Annals of Biomedical Engineering · doi:10.1007/s10439-016-1709-0 · Cited by 30
Single 5 μm diameter needle electrode block modules for unit recordings in vivo
Sawahata, H., Yamagiwa, S., Moriya, A., Dong, T., Oi, H., Ando, Y., Numano, R., Ishida, M., Koida, K., & Kawano, T. (2016) · Scientific Reports · doi:10.1038/srep35806 · Cited by 29
The History and Horizons of Microscale Neural Interfaces
Kozai, T. D. Y. (2018) · Micromachines · doi:10.3390/mi9090445 · Cited by 31
“There remains large variability in performance even between identical devices [69] due to both biological [58,67,70–72] and material integrity variance [73–75], even within the same subject [71,72].”
BackgroundInterfacing with the nervous system: a review of current bioelectric technologies
Sahyouni, R., Mahmoodi, A., Chen, J. W., Chang, D. T., Moshtaghi, O., Djalilian, H. R., & Lin, H. W. (2017) · Neurosurgical Review · doi:10.1007/s10143-017-0920-2 · Cited by 30
“Of note, investigators at the University of Utah have developed two types of multi-array electrodes: the Utah electrode array (UEA) and the Utah slanted electrode array (USEA) [25, 123].”
BackgroundSensors for brain temperature measurement and monitoring – a review
Izhar, U., Piyathilaka, L., & Preethichandra, D. M. G. (2022) · Neuroscience Informatics · doi:10.1016/j.neuri.2022.100106 · Cited by 29
Materials considerations of implantable neuroengineering devices for clinical use
Merrill, D. R. (2014) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2014.07.002 · Cited by 29
Achyuta, A. K. H., Polikov, V. S., White, A. J., Lewis, H. G. P., & Murthy, S. K. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900451 · Cited by 31
A chronic neural interface to the macaque dorsal column nuclei
Richardson, A. G., Weigand, P. K., Sritharan, S. Y., & Lucas, T. H. (2016) · Journal of Neurophysiology · doi:10.1152/jn.01083.2015 · Cited by 31
“This idea was scaled up to arrays of floating microelectrodes, which are now commercially available and widely used for chronic recording in the cortex of awake animals (Rousche and Normann 1998).”
BackgroundMicrosensors and microbiosensors for retinal implants
David, D. (2005) · Frontiers in bioscience · doi:10.2741/1518 · Cited by 29
“Since these early experiments, efforts have been underway to produce penetrating arrays of electrodes that offer the possibility of more closely spaced electrodes and therefore higher resolution cortical devices (16-19).”
BackgroundMethodChen, K., Cambi, F., & Kozai, T. D. Y. (2023) · Biomaterials · doi:10.1016/j.biomaterials.2023.122210 · Cited by 27
Neural Probes for Concurrent Detection of Neurochemical and Electrophysiological Signals in vivo
Johnson, M. D., Franklin, R. K., Scott, K., Brown, R. B., & Kipke, D. R. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616203 · Cited by 27
“While the classic application has been recording extra-cellular neuronal activity [1, 2], recently microfabricated neural probes have been developed for electrochemical monitoring of neurotransmitter synaptic overflow in vivo [3, 4].”
Background
Metadata
- Authors
- Rousche, P. J., & Normann, R. A.
- Affiliations
- University of Manchester (GB)
- University of Utah (US)
- Corresponding author
- Normann, Richard A
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 1998-07
- Volume
- 82
- Issue
- 1
- Pages
- 1-15
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W2142255743
- Semantic Scholar
- fd92cba70ad981a178a97e332f6c03cda18c0e4a
- Cited by
- 646
- References
- 31
- Citations by year
- 2026: 20 · 2025: 23 · 2024: 17 · 2023: 18 · 2022: 28 · 2021: 21 · 2020: 31 · 2019: 34 · 2018: 34 · 2017: 36 · 2016: 35 · 2015: 26 · 2014: 51 · 2013: 47 · 2012: 22
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Locations
- Journal of Neuroscience Methods (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Science Foundation
- W. M. Keck Foundation
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Life Sciences › Neuroscience › Cognitive Neuroscience › Neural dynamics and brain function
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
- Keywords
- chronic neural recording, silicon microelectrodes, sensory cortex, cats, astroglial response, fibrous encapsulation, electrode implantation
- MeSH terms
- Action Potentials, Animals, Cats, Electric Stimulation, Electrodes, Implanted, Microelectrodes, Somatosensory Cortex, Utah, Electric Impedance
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.