Stress-strain measurements of human and porcine corneas after riboflavin–ultraviolet-A-induced cross-linking
The DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the biomechanical effect of combined riboflavin-ultraviolet A (UVA) treatment on porcine and human corneas. SETTING: Department of Ophthalmology, Technical University of Dresden, Dresden, Germany. METHODS: Corneal strips from 5 human enucleated eyes and 20 porcine cadaver corneas were treated with the photosensitizer riboflavin and irradiated with 2 double UVA diodes (370 nm, irradiance = 3 mW/cm2) for 30 minutes. After cross-linking, static stress-strain measurements of the treated and untreated corneas were performed using a microcomputer-controlled biomaterial tester with a prestress of 5 x 10(3) Pa. RESULTS: There was a significant increase in corneal rigidity after cross-linking, indicated by a rise in stress in treated porcine corneas (by 71.9%) and human corneas (by 328.9%) and in Young's modulus by the factor 1.8 in porcine corneas and 4.5 in human corneas. The mean central corneal thickness was 850 microm +/- 70 (SD) in porcine corneas and 550 +/- 40 microm in human corneas. CONCLUSIONS: Riboflavin-UVA-induced collagen cross-linking led to an increase in mechanical rigidity in porcine corneas and an even greater increase in human corneas. As collagen cross-linking is maximal in the anterior 300 microm of the cornea, the greater stiffening effect in human corneas can be explained by the relatively larger portion of the cornea being cross-linked in the overall thinner human cornea.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Riboflavin/ultraviolet-a–induced collagen crosslinking for the treatment of keratoconus
Wollensak, G., Spoerl, E., & Seiler, T. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)02220-1 · Cited by 2,968
Self-citationCROSS-LINKING IN COLLAGEN AND ELASTIN
Eyre, D. R., Paz, M. A., & Gallop, P. M. (1984) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.53.070184.003441 · Cited by 1,309
Induction of Cross-links in Corneal Tissue
Spoerl, E., Huhle, M., & Seiler, T. G. (1998) · Experimental Eye Research · doi:10.1006/exer.1997.0410 · Cited by 980
Self-citationA 48-Year Clinical and Epidemiologic Study of Keratoconus
Kennedy, R. H., Bourne, W. M., & Dyer, J. A. (1986) · American Journal of Ophthalmology · doi:10.1016/0002-9394(86)90817-2 · Cited by 966
Increased resistance of crosslinked cornea against enzymatic digestion
Spoerl, E., Wollensak, G., & Seiler, T. G. (2004) · Current Eye Research · doi:10.1080/02713680490513182 · Cited by 709
Self-citationMechanisms of maturation and ageing of collagen
Bailey, A. J., Paul, R. G., & Knott, L. (1998) · Mechanisms of Ageing and Development · doi:10.1016/s0047-6374(98)00119-5 · Cited by 672
WILSON, S. E., HE, Y.-G., WENG, J., LI, Q., McDOWALL, A. W., VITAL, M., & CHWANG, E. L. (1996) · Experimental Eye Research · doi:10.1006/exer.1996.0038 · Cited by 594
Biomechanical properties of keratoconus and normal corneas
Andreassen, T. T., Hjorth Simonsen, A., & Oxlund, H. (1980) · Experimental Eye Research · doi:10.1016/s0014-4835(80)80027-3 · Cited by 540
The specific architecture of the anterior stroma accounts for maintenance of corneal curvature
Muller, L. J. (2001) · British Journal of Ophthalmology · doi:10.1136/bjo.85.4.437 · Cited by 424 · cited 1×
“In normal eyes, the more rigid anterior stroma also accounts for maintenance of the corneal curvature.(12,13)”
BackgroundIdziorek, T., Estaquier, J., De Bels, F., & Ameisen, J.-C. (1995) · Journal of Immunological Methods · doi:10.1016/0022-1759(95)00172-7 · Cited by 381
Cited by
Corneal Collagen Crosslinking: A Systematic Review
Sorkin, N., & Varssano, D. (2014) · Ophthalmologica · doi:10.1159/000357979 · Cited by 1,918
The Collagen Suprafamily: From Biosynthesis to Advanced Biomaterial Development
Sorushanova, A., Delgado, L. M., Wu, Z., Shologu, N., Kshirsagar, A., Raghunath, R., Mullen, A. M., Bayon, Y., Pandit, A., Raghunath, M., et al. (2019) · Advanced Materials · doi:10.1002/adma.201801651 · Cited by 1,151
Safety of UVA-Riboflavin Cross-Linking of the Cornea
Spoerl, E., Mrochen, M., Sliney, D., Trokel, S., & Seiler, T. (2007) · Cornea · doi:10.1097/ico.0b013e3180334f78 · Cited by 809
Self-citationLight in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 793
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Corneal collagen crosslinking for keratoconus and corneal ectasia: One-year results
Hersh, P. S., Greenstein, S. A., & Fry, K. L. (2011) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2010.07.030 · Cited by 451
Kohlhaas, M., Spoerl, E., Schilde, T., Unger, G., Wittig, C., & Pillunat, L. E. (2006) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2005.12.092 · Cited by 447
Self-citationRaiskup, F., Theuring, A., Pillunat, L. E., & Spoerl, E. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2014.09.033 · Cited by 429
Self-citationBrillouin Optical Microscopy for Corneal Biomechanics
Scarcelli, G., Pineda, R., & Yun, S. H. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8281 · Cited by 354
Jang, J., Kim, T. G., Kim, B. S., Kim, S.-W., Kwon, S.-M., & Cho, D.-W. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.01.013 · Cited by 344
Kanellopoulos, A. J. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20090813-10 · Cited by 320
McCall, A. S., Kraft, S., Edelhauser, H. F., Kidder, G. W., Lundquist, R. R., Bradshaw, H. E., Dedeic, Z., Dionne, M. J. C., Clement, E. M., & Conrad, G. W. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.09-3738 · Cited by 306
Risk Factors for Progression to Penetrating Keratoplasty in Patients With Keratoconus
Reeves, S. W., Stinnett, S., Adelman, R. A., & Afshari, N. A. (2005) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2005.05.029 · Cited by 290
Corneal Crosslinking with Riboflavin and Ultraviolet A. I. Principles
Raiskup, F., & Spoerl, E. (2013) · The Ocular Surface · doi:10.1016/j.jtos.2013.01.002 · Cited by 278
Self-citationOptical coherence elastography for tissue characterization: a review
Wang, S., & Larin, K. V. (2015) · Journal of Biophotonics · doi:10.1002/jbio.201400108 · Cited by 270
Martins, S. A. R., Combs, J. C., Noguera, G., Camacho, W., Wittmann, P., Walther, R., Cano, M., Dick, J., & Behrens, A. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1592 · Cited by 270
Transepithelial corneal collagen crosslinking for progressive keratoconus: 24-month clinical results
Caporossi, A., Mazzotta, C., Paradiso, A. L., Baiocchi, S., Marigliani, D., & Caporossi, T. (2013) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2013.03.026 · Cited by 264
Wernli, J., Schumacher, S., Spoerl, E., & Mrochen, M. (2013) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.12-11409 · Cited by 263
Self-citationTransepithelial corneal collagen crosslinking: Bilateral study
Filippello, M., Stagni, E., & O’Brart, D. (2012) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.08.030 · Cited by 248
Pandolfi, A., & Holzapfel, G. A. (2008) · Journal of Biomechanical Engineering · doi:10.1115/1.2982251 · Cited by 245
Corneal Biomechanics and Biomaterials
Ruberti, J. W., Sinha Roy, A., & Roberts, C. J. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105243 · Cited by 241
Accelerated versus conventional corneal collagen crosslinking
Tomita, M., Mita, M., & Huseynova, T. (2014) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2013.12.012 · Cited by 234
High-Resolution Quantitative Imaging of Cornea Elasticity Using Supersonic Shear Imaging
Tanter, M., Touboul, D., Gennisson, J.-L., Bercoff, J., & Fink, M. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2021471 · Cited by 234
“tained experimental results [37], [38].”
Optical coherence elastography in ophthalmology
Kirby, M. A., Pelivanov, I., Song, S., Ambrozinski, Ł., Yoon, S. J., Gao, L., Li, D., Shen, T. T., Wang, R. K., & O’Donnell, M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121720 · Cited by 228
Nonlinear Optical Macroscopic Assessment of 3-D Corneal Collagen Organization and Axial Biomechanics
Winkler, M., Chai, D., Kriling, S., Nien, C. J., Brown, D. J., Jester, B., Juhasz, T., & Jester, J. V. (2011) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8070 · Cited by 204
“Changes in corneal curvature after local stiffening have been observed in keratoconus corneas after corneal cross-linking treatment.(33) Wollensak(34) observed local flattening in areas of keratoconus corneas with increased rigidity after undergoing UV cross-linking treatment compared to the untreated, structurally co…”
BackgroundRandleman, J. B., Khandelwal, S. S., & Hafezi, F. (2015) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2015.04.002 · Cited by 203
“Initial treatment in porcine eyes showed up to 70% increase in cornea rigidity compared to controls(140) that was repeated in other studies using porcine,(143,166) rabbit,(144) and human cadaver eyes.(144,166) In these models, the safety of cross-linking was related to cornea thickness to avoid damage to the cornea en…”
ResultGlass, D. H., Roberts, C. J., Litsky, A. S., & Weber, P. A. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1321 · Cited by 201
Kanellopoulos, J. (2012) · Clinical Ophthalmology · doi:10.2147/opth.s27170 · Cited by 198
Corneal biomechanics – a review
Kling, S., & Hafezi, F. (2017) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12345 · Cited by 194
“For elastic testing, a slowly increasing load is applied (stress-strain diagram).(49) For viscoelastic testing, a one-step load is applied and maintained constant until the end of the test (stress-relaxation test), or a one-step dis placement is applied and maintained constant (creep test).”
Hydration behavior of porcine cornea crosslinked with riboflavin and ultraviolet A
Wollensak, G., Aurich, H., Pham, D.-T., & Wirbelauer, C. (2007) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2006.11.015 · Cited by 194
“for the treatment of progressive keratoconus, increasing the biomechanical strength of the human cornea by about 300%.(4) Its use is becoming increasingly popular.”
BackgroundSelf-citationFull-field deformation of bovine cornea under constrained inflation conditions
Boyce, B. L., Grazier, J. M., Jones, R. E., & Nguyen, T. D. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.06.011 · Cited by 191
Significance of the riboflavin film in corneal collagen crosslinking
Wollensak, G., Aurich, H., Wirbelauer, C., & Sel, S. (2010) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2009.07.044 · Cited by 174
Self-citationBiomechanical properties of the keratoconic cornea: a review
Vellara, H. R., & Patel, D. V. (2015) · Clinical and Experimental Optometry · doi:10.1111/cxo.12211 · Cited by 159
“9 per cent in porcine and human corneas, respectively.(82) Other techniques used to assess biomechanical properties ex vivo after collagen cross-linking include inflation testing.”
BackgroundElastography imaging: the 30 year perspective
Ormachea, J., & Parker, K. J. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abca00 · Cited by 104
Interaction of ultraviolet light with the cornea: clinical implications for corneal crosslinking
Lombardo, M., Pucci, G., Barberi, R., & Lombardo, G. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2014.12.013 · Cited by 62
Continuous formation of ultrathin, strong collagen sheets with tunable anisotropy and compaction
Malladi, S., Miranda-Nieves, D., Leng, L., Grainger, S. J., Tarabanis, C., Nesmith, A. P., Kosaraju, R., Haller, C. A., Parker, K. K., Chaikof, E. L., et al. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00321 · Cited by 34
Metadata
- Authors
- Wollensak, G., Spoerl, E., & Seiler, T.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2003-09
- Volume
- 29
- Issue
- 9
- Pages
- 1780-1785
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2150023663
- Cited by
- 1,024
- References
- 34
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.