Scanning microprobe matrix-assisted laser desorption ionization (SMALDI) mass spectrometry: Instrumentation for sub-micrometer resolved LDI and MALDI surface analysis
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
A new instrument and method is described for laterally resolved mass spectrometric surface analysis. Fields of application are in both the life sciences and the material sciences. The instrument provides for imaging of the distribution of selected sample components from natural and artificial surfaces. Samples are either analyzed by laser desorption ionization (LDI) time-of-flight mass spectrometry or, after preparation with a suitable matrix, by matrix-assisted laser desorption ionization (MALDI) mass spectrometry. Areas of 100 x 100 microm are scanned with minimal increments of 0.25 microm, and between 10,000 and 160,000 mass spectra are acquired per image within 3 to 50 min (scan rate up to 50 pixels per s). The effective lateral resolution is in the range of 0.6 to 1.5 microm depending on sample properties, preparation methods and laser wavelength. Optical investigation of the same sample area by UV confocal scanning laser microscopy was found to be very attractive in combination with scanning MALDI mass analysis because pixel-identical images can be created with both techniques providing for a strong increase in analytical information. This article describes the method and instrumentation, including first applicational examples in elemental analysis, imaging of pine tree roots, and investigation of MALDI sample morphology in biomolecular analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Molecular Imaging of Biological Samples: Localization of Peptides and Proteins Using MALDI-TOF MS
Caprioli, R. M., Farmer, T. B., & Gile, J. (1997) · Analytical Chemistry · doi:10.1021/ac970888i · Cited by 2,234 · cited 1×
“Due to instrumental and methodological limitations, MALDI imaging has so far been limited to a lateral resolution of approximately 30 m [18, 25–30], limiting its application to relatively large structures.”
BackgroundMatrix-assisted ultraviolet laser desorption of non-volatile compounds
Karas, M., Bachmann, D., Bahr, U., & Hillenkamp, F. (1987) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(87)87041-6 · Cited by 1,953
Stoeckli, M., Chaurand, P., Hallahan, D. E., & Caprioli, R. M. (2001) · Nature Medicine · doi:10.1038/86573 · Cited by 1,172
Karas, M., Bachmann, D., & Hillenkamp, F. (1985) · Analytical Chemistry · doi:10.1021/ac00291a042 · Cited by 935
Karas, M., Gl�ckmann, M., & Sch�fer, J. (2000) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(200001)35:1<1::aid-jms904>3.0.co;2-0 · Cited by 614
[22] Electrospray ionization mass spectrometry
Edmonds, C. G., & Smith, R. D. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93430-s · Cited by 508
Matrix‐assisted laser desorption ionization mass spectrometry
Karas, M., Bahr, U., & Gießmann, U. (1991) · Mass Spectrometry Reviews · doi:10.1002/mas.1280100503 · Cited by 377
Spengler, B. (1997) · Journal of Mass Spectrometry · doi:10.1002/(sici)1096-9888(199711)32:10<1019::aid-jms595>3.0.co;2-g · Cited by 321
Self-citationTodd, P. J., Schaaff, T. G., Chaurand, P., & Caprioli, R. M. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.153 · Cited by 298
Cited by
McDonnell, L. A., & Heeren, R. M. A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20124 · Cited by 1,082
MALDI imaging mass spectrometry: molecular snapshots of biochemical systems
Cornett, D. S., Reyzer, M. L., Chaurand, P., & Caprioli, R. M. (2007) · Nature Methods · doi:10.1038/nmeth1094 · Cited by 886
The Desorption Process in MALDI
Dreisewerd, K. (2003) · Chemical Reviews · doi:10.1021/cr010375i · Cited by 709
Norris, J. L., & Caprioli, R. M. (2013) · Chemical Reviews · doi:10.1021/cr3004295 · Cited by 696
Mass Spectrometric Imaging for Biomedical Tissue Analysis
Chughtai, K., & Heeren, R. M. A. (2010) · Chemical Reviews · doi:10.1021/cr100012c · Cited by 652
Touboul, D., Kollmer, F., Niehuis, E., Brunelle, A., & Laprévote, O. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.005 · Cited by 364
Mass spectrometry imaging with high resolution in mass and space
Römpp, A., & Spengler, B. (2013) · Histochemistry and Cell Biology · doi:10.1007/s00418-013-1097-6 · Cited by 358
Self-citationImaging mass spectrometry in microbiology
Watrous, J. D., & Dorrestein, P. C. (2011) · Nature Reviews Microbiology · doi:10.1038/nrmicro2634 · Cited by 338
Ferroptosis in health and disease
Berndt, C., Alborzinia, H., Amen, V. S., Ayton, S., Barayeu, U., Bartelt, A., Bayir, H., Bebber, C. M., Birsoy, K., Böttcher, J. P., et al. (2024) · Redox Biology · doi:10.1016/j.redox.2024.103211 · Cited by 334
Direct Analysis and MALDI Imaging of Formalin-Fixed, Paraffin-Embedded Tissue Sections
Lemaire, R., Desmons, A., Tabet, J. C., Day, R., Salzet, M., & Fournier, I. (2007) · Journal of Proteome Research · doi:10.1021/pr060549i · Cited by 309
MALDI mass spectrometric imaging of biological tissue sections
Rohner, T. C., Staab, D., & Stoeckli, M. (2005) · Mechanisms of Ageing and Development · doi:10.1016/j.mad.2004.09.032 · Cited by 304
Taylor, M. J., Lukowski, J. K., & Anderton, C. R. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00439 · Cited by 302
Seeley, E. H., Oppenheimer, S. R., Mi, D., Chaurand, P., & Caprioli, R. M. (2008) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2008.03.016 · Cited by 300
MALDI-MS imaging of features smaller than the size of the laser beam
Jurchen, J. C., Rubakhin, S. S., & Sweedler, J. V. (2005) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2005.06.006 · Cited by 285
Single‐Cell Mass Spectrometry Approaches to Explore Cellular Heterogeneity
Zhang, L., & Vertes, A. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201709719 · Cited by 276
High-Spatial Resolution Mass Spectrometric Imaging of Peptide and Protein Distributions on a Surface
Luxembourg, S. L., Mize, T. H., McDonnell, L. A., & Heeren, R. M. A. (2004) · Analytical Chemistry · doi:10.1021/ac049692q · Cited by 267
Proteomics in Diagnostic Pathology
Chaurand, P., Sanders, M. E., Jensen, R. A., & Caprioli, R. M. (2004) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63367-6 · Cited by 253
Spatial metabolomics of in situ host–microbe interactions at the micrometre scale
Geier, B., Sogin, E. M., Michellod, D., Janda, M., Kompauer, M., Spengler, B., Dubilier, N., & Liebeke, M. (2020) · Nature Microbiology · doi:10.1038/s41564-019-0664-6 · Cited by 234
Self-citationLipid imaging by mass spectrometry – a review
Gode, D., & Volmer, D. A. (2013) · The Analyst · doi:10.1039/c2an36337b · Cited by 217
Nilsson, A., Fehniger, T. E., Gustavsson, L., Andersson, M., Kenne, K., Marko-Varga, G., & Andrén, P. E. (2010) · PLoS ONE · doi:10.1371/journal.pone.0011411 · Cited by 215
“Recent reports indicate technology advancements capable of irradiating and imaging areas with a resolution as small as ,1 mm [20].”
BackgroundVaysse, P.-M., Heeren, R. M. A., Porta, T., & Balluff, B. (2017) · The Analyst · doi:10.1039/c7an00565b · Cited by 215
Profiling and imaging of tissues by imaging ion mobility‐mass spectrometry
McLean, J. A., Ridenour, W. B., & Caprioli, R. M. (2007) · Journal of Mass Spectrometry · doi:10.1002/jms.1254 · Cited by 209
Römpp, A., Guenther, S., Schober, Y., Schulz, O., Takats, Z., Kummer, W., & Spengler, B. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200905559 · Cited by 203
Self-citationMass spectrometry imaging and profiling of single cells
Lanni, E. J., Rubakhin, S. S., & Sweedler, J. V. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.03.017 · Cited by 201
“Spengler and Hubert [142] reported a similar system, delivering the laser coaxially from the other direction via a central aperture bored through the quartz optical lenses.”
BackgroundCha, S., & Yeung, E. S. (2007) · Analytical Chemistry · doi:10.1021/ac062251h · Cited by 196
Single Cell Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry Imaging
Schober, Y., Guenther, S., Spengler, B., & Römpp, A. (2012) · Analytical Chemistry · doi:10.1021/ac301337h · Cited by 194
Self-citationAtmospheric Pressure Molecular Imaging by Infrared MALDI Mass Spectrometry
Li, Y., Shrestha, B., & Vertes, A. (2007) · Analytical Chemistry · doi:10.1021/ac061577n · Cited by 193
Metabolic Imaging at the Single-Cell Scale: Recent Advances in Mass Spectrometry Imaging
Gilmore, I. S., Heiles, S., & Pieterse, C. L. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-115516 · Cited by 192
Imaging mass spectrometry: fundamentals and applications to drug discovery
Rubakhin, S. S., Jurchen, J. C., Monroe, E. B., & Sweedler, J. V. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03458-6 · Cited by 190
Hsieh, Y., Casale, R., Fukuda, E., Chen, J., Knemeyer, I., Wingate, J., Morrison, R., & Korfmacher, W. (2006) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.2397 · Cited by 187
Altelaar, A. F. M., van Minnen, J., Jiménez, C. R., Heeren, R. M. A., & Piersma, S. R. (2005) · Analytical Chemistry · doi:10.1021/ac048329g · Cited by 182
Solid Ionic Matrixes for Direct Tissue Analysis and MALDI Imaging
Lemaire, R., Tabet, J. C., Ducoroy, P., Hendra, J. B., Salzet, M., & Fournier, I. (2006) · Analytical Chemistry · doi:10.1021/ac0514669 · Cited by 181
Subcellular imaging mass spectrometry of brain tissue
McDonnell, L. A., Piersma, S. R., Altelaar, A. F. M., Mize, T. H., Luxembourg, S. L., Verhaert, P. D. E. M., van Minnen, J., & Heeren, R. M. A. (2005) · Journal of Mass Spectrometry · doi:10.1002/jms.735 · Cited by 173
Imaging Mass Spectrometry: Principles and Potentials
Chaurand, P., Schwartz, S. A., Reyzer, M. L., & Caprioli, R. M. (2005) · Toxicologic Pathology · doi:10.1080/01926230590881862 · Cited by 172
Imaging of peptides in the rat brain using MALDI-FTICR mass spectrometry
Taban, I. M., Altelaar, A. F. M., van der Burgt, Y. E. M., McDonnell, L. A., Heeren, R. M. A., Fuchser, J., & Baykut, G. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2006.09.017 · Cited by 164
“The development of micrometer resolution has been reported [ 33 ], however decreasing spot size has been found to lead to decreasing sensitivity for high mass species.”
Protein and peptides in pictures: Imaging with MALDI mass spectrometry
Goodwin, R. J. A., Pennington, S. R., & Pitt, A. R. (2008) · PROTEOMICS · doi:10.1002/pmic.200800320 · Cited by 164
“[70] Spengler, B., Hubert, M., Scanning microprobe matrixassisted laser desorption ionization (SMALDI) mass spectrometry: Instrumentation for sub-micrometer resolved LDI and MALDI surface analysis.”
BackgroundMethodInfluentialKoestler, M., Kirsch, D., Hester, A., Leisner, A., Guenther, S., & Spengler, B. (2008) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.3733 · Cited by 161
Self-citationGarrett, T. J., Prieto-Conaway, M. C., Kovtoun, V., Bui, H., Izgarian, N., Stafford, G., & Yost, R. A. (2007) · International Journal of Mass Spectrometry · doi:10.1016/j.ijms.2006.09.019 · Cited by 160
Körber, A., Anthony, I. G. M., & Heeren, R. M. A. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c05249 · Cited by 88
Metadata
- Authors
- Spengler, B., & Hubert, M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2002-06-01
- Volume
- 13
- Issue
- 6
- Pages
- 735-748
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2054792262
- Cited by
- 292
- References
- 23
- FWCI
- 4.96
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.