Effect of different solution flow rates on analyte ion signals in nano-ESI MS, or: when does ESI turn into nano-ESI?
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
In nano-ESI MS, the qualitative and quantitative characteristics of mass spectra vary considerably upon the use of different spraying conditions, i.e., aperture of the spraying needle and the voltage applied. The major parameters affected by the aperture size is the liquid flow rate which determines the initial droplet size and the current emitted upon the spray process, as described by different models of the ESI process. In the present study, the effect of flow rate on ion signals was studied systematically using mixtures of compounds with different physicochemical properties (i.e., detergent/oligosaccharide and oligosaccharide/peptide). For these model systems, the functional dependence of certain analyte-ion ratios upon the flow rate can be correlated to changes in analyte partition during droplet fission prior to ion release. Analyte suppression is practically absent at minimal flow rates below 20 nL/min.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
CRC Handbook of Chemistry and Physics
(2014) · doi:10.1201/b17118 · Cited by 57,706
Handbook of Chemistry and Physics
(1937) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/20.1.142a · Cited by 4,741
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Dole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
Mass Spectrometry in Proteomics
Aebersold, R., & Goodlett, D. R. (2001) · Chemical Reviews · doi:10.1021/cr990076h · Cited by 1,238
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 1,140
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
The current emitted by highly conducting Taylor cones
De La Mora, J. F., & Loscertales, I. G. (1994) · Journal of Fluid Mechanics · doi:10.1017/s0022112094003472 · Cited by 884
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Cited by
Electrospray: From ions in solution to ions in the gas phase, what we know now
Kebarle, P., & Verkerk, U. H. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20247 · Cited by 905
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Advances in structure elucidation of small molecules using mass spectrometry
Kind, T., & Fiehn, O. (2010) · Bioanalytical Reviews · doi:10.1007/s12566-010-0015-9 · Cited by 480
Panuwet, P., Hunter, R. E., D'Souza, P. E., Chen, X., Radford, S. A., Cohen, J. R., Marder, M. E., Kartavenka, K., Ryan, P. B., & Barr, D. B. (2016) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.980775 · Cited by 394
Single-cell Proteomics: Progress and Prospects
Kelly, R. T. (2020) · Molecular & Cellular Proteomics · doi:10.1074/mcp.r120.002234 · Cited by 356
Advances in proteomics data analysis and display using an accurate mass and time tag approach
Zimmer, J. S. D., Monroe, M. E., Qian, W., & Smith, R. D. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20071 · Cited by 304
Analytical strategies for identifying drug metabolites
Prakash, C., Shaffer, C. L., & Nedderman, A. (2007) · Mass Spectrometry Reviews · doi:10.1002/mas.20128 · Cited by 302
The ion funnel: Theory, implementations, and applications
Kelly, R. T., Tolmachev, A. V., Page, J. S., Tang, K., & Smith, R. D. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20232 · Cited by 280
Ionization and transmission efficiency in an electrospray ionization—mass spectrometry interface
Page, J. S., Kelly, R. T., Tang, K., & Smith, R. D. (2007) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2007.05.018 · Cited by 265
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Kachala, V. V., Khemchyan, L. L., Kashin, A. S., Orlov, N. V., Grachev, A. A., Zalesskiy, S. S., & Ananikov, V. P. (2013) · Russian Chemical Reviews · doi:10.1070/rc2013v082n07abeh004413 · Cited by 262
Tang, K., Page, J. S., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.034 · Cited by 262
Confined Nanopipette Sensing: From Single Molecules, Single Nanoparticles, to Single Cells
Yu, R., Ying, Y., Gao, R., & Long, Y. (2019) · Angewandte Chemie International Edition · doi:10.1002/anie.201803229 · Cited by 255
Swan, A. L., Mobasheri, A., Allaway, D., Liddell, S., & Bacardit, J. (2013) · OMICS: A Journal of Integrative Biology · doi:10.1089/omi.2013.0017 · Cited by 249
“ESI has been further developed to form nano-ESI, a technique that offers a number of benefits including smaller analyte requirements, greater tolerance of contaminants, and higher sensitivity to hydrophilic compounds (Schmidt et al., 2003; Wilm and Mann, 1994).”
BackgroundKelly, R. T., Page, J. S., Luo, Q., Moore, R. J., Orton, D. J., Tang, K., & Smith, R. D. (2006) · Analytical Chemistry · doi:10.1021/ac061133r · Cited by 240
Christofi, E., & Barran, P. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.2c00600 · Cited by 233
Bioanalytical LC–MS/MS of protein-based biopharmaceuticals
van den Broek, I., Niessen, W. M. A., & van Dongen, W. D. (2013) · Journal of Chromatography B · doi:10.1016/j.jchromb.2013.04.030 · Cited by 232
Characterization of the human blood plasma proteome
Shen, Y., Kim, J., Strittmatter, E. F., Jacobs, J. M., Camp, D. G., Fang, R., Tolié, N., Moore, R. J., & Smith, R. D. (2005) · PROTEOMICS · doi:10.1002/pmic.200401246 · Cited by 225
Liquid Chromatography-Mass Spectrometry-based Quantitative Proteomics
Xie, F., Liu, T., Qian, W.-J., Petyuk, V. A., & Smith, R. D. (2011) · Journal of Biological Chemistry · doi:10.1074/jbc.r110.199703 · Cited by 215
Maxwell, E. J., & Chen, D. D. Y. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.06.034 · Cited by 197
Comparative LC‐MS: A landscape of peaks and valleys
America, A. H. P., & Cordewener, J. H. G. (2008) · PROTEOMICS · doi:10.1002/pmic.200700694 · Cited by 191
“Comparative LC-MS approaches rely on the observation that the peak intensity (or better: peak volume as detected in LCMS mode) in most cases is proportional to the concentration of the peptide in the sample [13, 15, 54, 55].”
BackgroundTrends in sample preparation for classical and second generation proteomics
Cañas, B., Piñeiro, C., Calvo, E., López-Ferrer, D., & Gallardo, J. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.045 · Cited by 181
Di Palma, S., Hennrich, M. L., Heck, A. J. R., & Mohammed, S. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.033 · Cited by 170
“[59] Schmidt A, Karas M, Dulcks T.”
MethodRampler, E., Abiead, Y. E., Schoeny, H., Rusz, M., Hildebrand, F., Fitz, V., & Koellensperger, G. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.0c04698 · Cited by 168
Susa, A. C., Xia, Z., & Williams, E. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04897 · Cited by 167
John, H., Walden, M., Sch�fer, S., Genz, S., & Forssmann, W.-G. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2298-y · Cited by 167
Busnel, J.-M., Schoenmaker, B., Ramautar, R., Carrasco-Pancorbo, A., Ratnayake, C., Feitelson, J. S., Chapman, J. D., Deelder, A. M., & Mayboroda, O. A. (2010) · Analytical Chemistry · doi:10.1021/ac102159d · Cited by 165
Welthagen, W., Shellie, R. A., Spranger, J., Ristow, M., Zimmermann, R., & Fiehn, O. (2005) · Metabolomics · doi:10.1007/s11306-005-1108-2 · Cited by 165
“…infusion-MS may be easily applied for sample classification (Vaidyanathan et al., 2001; Allen et al., 2003; Scholz et al., 2004), relative quantitation of individual metabolites is problematic, due to severe physical limitations such as ion suppression (Schmidt et al., 2003) and adduct formation.”
BackgroundSoutham, A. D., Weber, R. J. M., Engel, J., Jones, M. R., & Viant, M. R. (2017) · Nature Protocols · doi:10.1038/nprot.2016.156 · Cited by 162
Nanoelectrospray emitters: Trends and perspective
Gibson, G. T. T., Mugo, S. M., & Oleschuk, R. D. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20248 · Cited by 158
“Schmidt, Karas, and Dulcks (2003) studied ion suppression effects as an indicator of nanoelectrospray behavior, finding that highly surface-active ions strongly suppress more hydrophilic ions at higher flow rates, owing to the enrichment of surface ions in uneven droplet fission.”
BackgroundHaselberg, R., de Jong, G. J., & Somsen, G. W. (2013) · Analytical Chemistry · doi:10.1021/ac303158f · Cited by 149
CE–MS for proteomics: Advances in interface development and application
Ramautar, R., Heemskerk, A. A. M., Hensbergen, P. J., Deelder, A. M., Busnel, J.-M., & Mayboroda, O. A. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.04.050 · Cited by 86
Sarg, B., Faserl, K., Kremser, L., Halfinger, B., Sebastiano, R., & Lindner, H. H. (2013) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m112.024109 · Cited by 76
Kammeijer, G. S. M., Kohler, I., Jansen, B. C., Hensbergen, P. J., Mayboroda, O. A., Falck, D., & Wuhrer, M. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b00479 · Cited by 74
CE–ESI‐MS for bottom‐up proteomics: Advances in separation, interfacing and applications
Heemskerk, A. A. M., Deelder, A. M., & Mayboroda, O. A. (2016) · Mass Spectrometry Reviews · doi:10.1002/mas.21432 · Cited by 61
Quantitative Proteomics Using Ultralow Flow Capillary Electrophoresis–Mass Spectrometry
Faserl, K., Kremser, L., Müller, M., Teis, D., & Lindner, H. H. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b00312 · Cited by 57
Höcker, O., Montealegre, C., & Neusüß, C. (2018) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-018-1179-3 · Cited by 55
Zhu, Y., Piehowski, P. D., Kelly, R. T., & Qian, W.-J. (2018) · Expert Review of Proteomics · doi:10.1080/14789450.2018.1537787 · Cited by 50
Evaluation of a sheathless nanospray interface based on a porous tip sprayer for CE‐ESI‐MS coupling
Bonvin, G., Veuthey, J., Rudaz, S., & Schappler, J. (2012) · ELECTROPHORESIS · doi:10.1002/elps.201100461 · Cited by 48
Yin, Y., Li, G., Guan, Y., & Huang, G. (2016) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.7621 · Cited by 11
Metadata
- Authors
- Schmidt, A., Karas, M., & Dülcks, T.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-05-01
- Volume
- 14
- Issue
- 5
- Pages
- 492-500
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2067519806
- Cited by
- 534
- References
- 25
- FWCI
- 6.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.