Matrix effect in bio-analysis of illicit drugs with LC-MS/MS: Influence of ionization type, sample preparation, and biofluid
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The purpose of the present work was to evaluate the synergistic effect of ionization type, sample preparation technique, and bio-fluid on the presence of matrix effect in quantitative liquid chromatography (LC)-MS/MS analysis of illicit drugs by post-column infusion experiments with morphine (10-microg/mL solution). Three bio-fluids (urine, oral fluid, and plasma) were pretreated with four sample preparation procedures [direct injection, dilution, protein precipitation, solid-phase extraction (SPE)] and analyzed by both LC-electrospray ionization (ESI)-MS/MS and LC-atmospheric pressure chemical ionization (APCI)-MS/MS. Our results indicated that both ionization types showed matrix effect, but ESI was more susceptible than APCI. Sample preparation could reduce (clean up) or magnify (pre-concentrate) matrix effect. Residual matrix components were specific to each bio-fluid and interfered at different time points in the chromatogram. We evaluated matrix effect in an early stage of method development and combined optimal ionization type and sample preparation technique for each bio-fluid. Simple dilution of urine was sufficient to allow for the analysis of the analytes of interest by LC-APCI-MS/MS. Acetonitrile protein precipitation provided both sample clean up and concentration for oral fluid analysis, while SPE was necessary for extensive clean up of plasma prior to LC-APCI-MS/MS.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Mechanistic investigation of ionization suppression in electrospray ionization
King, R., Bonfiglio, R., Fernandez-Metzler, C., Miller-Stein, C., & Olah, T. (2000) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(00)00163-x · Cited by 1,086
Bonfiglio, R., King, R. C., Olah, T. V., & Merkle, K. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990630)13:12<1175::aid-rcm639>3.0.co;2-0 · Cited by 939
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Mechanistic aspects of electrospray ionization
Bruins, A. P. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01110-2 · Cited by 368
Buhrman, D. L., Price, P. I., & Rudewiczcor, P. J. (1996) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(96)00072-4 · Cited by 364
Mei, H., Hsieh, Y., Nardo, C., Xu, X., Wang, S., Ng, K., & Korfmacher, W. A. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.876 · Cited by 350
Cone, E. J., Hillsgrove, M., & Darwin, W. D. (1994) · Clinical Chemistry · doi:10.1093/clinchem/40.7.1299 · Cited by 151
Progress of Liquid Chromatography–Mass Spectrometry in Clinical and Forensic Toxicology
Marquet, P. P. (2002) · Therapeutic Drug Monitoring · doi:10.1097/00007691-200204000-00008 · Cited by 138
Dams, R., Murphy, C. M., Choo, R. E., Lambert, W. E., De Leenheer, A. P., & Huestis, M. A. (2003) · Analytical Chemistry · doi:10.1021/ac026111t · Cited by 87
Self-citation
Cited by
Peters, F. T., Drummer, O. H., & Musshoff, F. (2007) · Forensic Science International · doi:10.1016/j.forsciint.2006.05.021 · Cited by 1,343
Taylor, P. J. (2005) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2004.11.007 · Cited by 1,248
An overview of matrix effects in liquid chromatography–mass spectrometry
Trufelli, H., Palma, P., Famiglini, G., & Cappiello, A. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20298 · Cited by 811
Validation of bioanalytical LC–MS/MS assays: Evaluation of matrix effects
Van Eeckhaut, A., Lanckmans, K., Sarre, S., Smolders, I., & Michotte, Y. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.01.003 · Cited by 763
Signal suppression/enhancement in high-performance liquid chromatography tandem mass spectrometry
Gosetti, F., Mazzucco, E., Zampieri, D., & Gennaro, M. C. (2010) · Journal of Chromatography A · doi:10.1016/j.chroma.2009.11.060 · Cited by 680
Matrix effects in quantitative pesticide analysis using liquid chromatography–mass spectrometry
Niessen, W. M. A., Manini, P., & Andreoli, R. (2006) · Mass Spectrometry Reviews · doi:10.1002/mas.20097 · Cited by 435
Does a stable isotopically labeled internal standard always correct analyte response?
Wang, S., Cyronak, M., & Yang, E. (2007) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2006.08.010 · Cited by 401
Panuwet, P., Hunter, R. E., D'Souza, P. E., Chen, X., Radford, S. A., Cohen, J. R., Marder, M. E., Kartavenka, K., Ryan, P. B., & Barr, D. B. (2016) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408347.2014.980775 · Cited by 394
Oral fluid testing for drugs of abuse
Bosker, W. M., & Huestis, M. A. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.108670 · Cited by 378
Self-citationTutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Tutorial review on validation of liquid chromatography–mass spectrometry methods: Part I
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.017 · Cited by 300
Hummel, D., Löffler, D., Fink, G., & Ternes, T. A. (2006) · Environmental Science & Technology · doi:10.1021/es061740w · Cited by 299
Cortese, M., Gigliobianco, M. R., Magnoni, F., Censi, R., & Di Martino, P. (2020) · Molecules · doi:10.3390/molecules25133047 · Cited by 280
Current role of liquid chromatography–mass spectrometry in clinical and forensic toxicology
Maurer, H. H. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1248-5 · Cited by 257
LITTLE, J., WEMPE, M., & BUCHANAN, C. (2006) · Journal of Chromatography B · doi:10.1016/j.jchromb.2006.02.011 · Cited by 256
González, O., Blanco, M. E., Iriarte, G., Bartolomé, L., Maguregui, M. I., & Alonso, R. M. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.03.077 · Cited by 253
Overcoming Matrix Effects in Liquid Chromatography−Mass Spectrometry
Cappiello, A., Famiglini, G., Palma, P., Pierini, E., Termopoli, V., & Trufelli, H. (2008) · Analytical Chemistry · doi:10.1021/ac8018312 · Cited by 253
Tears as a source of biomarkers for ocular and systemic diseases
von Thun und Hohenstein-Blaul, N., Funke, S., & Grus, F. H. (2013) · Experimental Eye Research · doi:10.1016/j.exer.2013.07.015 · Cited by 233
Raposo, F., & Barceló, D. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116068 · Cited by 217
Gheorghe, A., van Nuijs, A., Pecceu, B., Bervoets, L., Jorens, P. G., Blust, R., Neels, H., & Covaci, A. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1754-5 · Cited by 204
The role of alternative specimens in toxicological analysis
Gallardo, E., & Queiroz, J. A. (2008) · Biomedical Chromatography · doi:10.1002/bmc.1009 · Cited by 200
“Several papers addressing this issue have been published (Dams et al., 2003; Annesley, 2003).”
BackgroundPerrone, D., Donangelo, C. M., & Farah, A. (2008) · Food Chemistry · doi:10.1016/j.foodchem.2008.03.012 · Cited by 190
Wang, Y., Armando, A. M., Quehenberger, O., Yan, C., & Dennis, E. A. (2014) · Journal of Chromatography A · doi:10.1016/j.chroma.2014.07.006 · Cited by 185
Maurer, H. H. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.250 · Cited by 178
“(92) evaluated the synergistic effect of ionization type, sample preparation technique, and bio-fluid (urine, oral fluid, and plasma) on the presence of matrix effects.”
Matrix Effects—A Challenge toward Automation of Molecular Analysis
Chiu, M. L., Lawi, W., Snyder, S. T., Wong, P. K., Liao, J. C., & Gau, V. (2010) · JALA: Journal of the Association for Laboratory Automation · doi:10.1016/j.jala.2010.02.001 · Cited by 175
Veterinary drug residues in meat: Concerns and rapid methods for detection
Reig, M., & Toldrá, F. (2008) · Meat Science · doi:10.1016/j.meatsci.2007.07.029 · Cited by 167
Hernando, M. D., Petrovic, M., Fernández-Alba, A. R., & Barceló, D. (2004) · Journal of Chromatography A · doi:10.1016/j.chroma.2004.06.102 · Cited by 163
Deng, Y., Liao, Q., Li, S., Bi, K., Pan, B., & Xie, Z. (2008) · Journal of Chromatography B · doi:10.1016/j.jchromb.2007.12.028 · Cited by 162
Kolmonen, M., Leinonen, A., Pelander, A., & Ojanperä, I. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2006.12.028 · Cited by 161
Peters, F. T., & Remane, D. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-012-6035-2 · Cited by 159
“However, some of the affected compounds eluted later in the chromatogram emphasizing earlier observations, that MEs may occur at any time during a chromatographic run [19, 24].”
BackgroundMethodResultInfluentialBerg, T., & Strand, D. H. (2011) · Journal of Chromatography A · doi:10.1016/j.chroma.2011.10.081 · Cited by 158
Sigmund, G., Koch, A., Orlovius, A., Guddat, S., Thomas, A., Schänzer, W., & Thevis, M. (2014) · Drug Testing and Analysis · doi:10.1002/dta.1680 · Cited by 22
Metadata
- Authors
- Dams, R., Huestis, M. A., Lambert, W. E., & Murphy, C. M.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2003-11-01
- Volume
- 14
- Issue
- 11
- Pages
- 1290-1294
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2007455664
- Cited by
- 600
- References
- 10
- FWCI
- 23.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.