Diagnostic point-of-care tests in resource-limited settings
Open accessThe DOI matches its Crossref record; 117 of the 117 references it cites were found in a registry or an index.
Abstract
Diagnostic point-of-care (POC) testing is intended to minimize the time to obtain a test result, thereby allowing clinicians and patients to make an expeditious clinical decision. As POC tests expand into resource-limited settings (RLS), the benefits must outweigh the costs. To optimize POC testing in RLS, diagnostic POC tests need rigorous evaluations focused on relevant clinical outcomes and operational costs, which differ from evaluations of conventional diagnostic tests. Here, we reviewed published studies on POC testing in RLS, and found no clearly defined metric for the clinical utility of POC testing. Therefore, we propose a framework for evaluating POC tests, and suggest and define the term “test efficacy” to describe a diagnostic test’s capacity to support a clinical decision within its operational context. We also proposed revised criteria for an ideal diagnostic POC test in resource-limited settings. Through systematic evaluations, comparisons between centralized diagnostic testing and novel POC technologies can be more formalized, and health officials can better determine which POC technologies represent valuable additions to their clinical programs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Methods for the Economic Evaluation of Health Care Programmes
Drummond, M. E., Sculpher, M. J., Torrance, G. W., O’Brien, B. J., & Stoddart, G. L. (2005) · doi:10.1093/oso/9780198529446.001.0001 · Cited by 13,648
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Rapid Molecular Detection of Tuberculosis and Rifampin Resistance
Boehme, C. C., Nabeta, P., Hillemann, D., Nicol, M. P., Shenai, S., Krapp, F., Allen, J., Tahirli, R., Blakemore, R., Rustomjee, R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0907847 · Cited by 2,309
Cost-Benefit Analysis: Concepts and Practice
Boardman, A. E., Greenberg, D. H., Vining, A. R., & Weimer, D. L. (1996) · Cited by 1,920
Grading quality of evidence and strength of recommendations for diagnostic tests and strategies
Schünemann, H. J., Oxman, A. D., Brozek, J., Glasziou, P., Jaeschke, R., Vist, G. E., Williams, J. W., Kunz, R., Craig, J., Montori, V. M., et al. (2008) · BMJ · doi:10.1136/bmj.39500.677199.ae · Cited by 1,782
Problems of Spectrum and Bias in Evaluating the Efficacy of Diagnostic Tests
Ransohoff, D. F., & Feinstein, A. R. (1978) · New England Journal of Medicine · doi:10.1056/nejm197810262991705 · Cited by 1,734
Applying the right statistics: analyses of measurement studies
Bland, J. M., & Altman, D. G. (2003) · Ultrasound in Obstetrics & Gynecology · doi:10.1002/uog.122 · Cited by 1,311
Xpert® MTB/RIF assay for pulmonary tuberculosis and rifampicin resistance in adults
Steingart, K. R., Schiller, I., Horne, D. J., Pai, M., Boehme, C. C., & Dendukuri, N. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009593.pub3 · Cited by 1,102
Point-of-Care Diagnostics for Global Health
Yager, P., Domingo, G. J., & Gerdes, J. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160524 · Cited by 1,076
Cited by
Becherer, L., Borst, N., Bakheit, M., Frischmann, S., Zengerle, R., & von Stetten, F. (2020) · Analytical Methods · doi:10.1039/c9ay02246e · Cited by 429
Hang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Point-of-Care Diagnostics in Low Resource Settings: Present Status and Future Role of Microfluidics
Sharma, S., Zapatero-Rodríguez, J., Estrela, P., & O'Kennedy, R. (2015) · Biosensors · doi:10.3390/bios5030577 · Cited by 349
Beyond the lateral flow assay: A review of paper-based microfluidics
Carrell, C., Kava, A., Nguyen, M., Menger, R., Munshi, Z., Call, Z., Nussbaum, M., & Henry, C. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2018.12.002 · Cited by 336
Point-of-care testing based on smartphone: The current state-of-the-art (2017–2018)
Liu, J., Geng, Z., Fan, Z., Liu, J., & Chen, H. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.01.068 · Cited by 335
Portable biosensing devices for point-of-care diagnostics: Recent developments and applications
Zarei, M. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.04.001 · Cited by 326
Taking connected mobile-health diagnostics of infectious diseases to the field
Wood, C. S., Thomas, M. R., Budd, J., Mashamba-Thompson, T. P., Herbst, K., Pillay, D., Peeling, R. W., Johnson, A. M., McKendry, R. A., & Stevens, M. M. (2019) · Nature · doi:10.1038/s41586-019-0956-2 · Cited by 323
Rapid and Fully Microfluidic Ebola Virus Detection with CRISPR-Cas13a
Qin, P., Park, M., Alfson, K. J., Tamhankar, M., Carrion, R., Patterson, J. L., Griffiths, A., He, Q., Yildiz, A., Mathies, R., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00239 · Cited by 311
Recent advances in molecularly imprinted polymer-based electrochemical sensors
Li, Y., Luo, L., Kong, Y., Li, Y., Wang, Q., Wang, M., Li, Y., Davenport, A., & Li, B. (2024) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2024.116018 · Cited by 308
Synergy between nanomaterials and volatile organic compounds for non-invasive medical evaluation
Broza, Y. Y., Vishinkin, R., Barash, O., Nakhleh, M. K., & Haick, H. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00317c · Cited by 276
Alam, M. M., Malik, H., Khan, M. I., Pardy, T., Kuusik, A., & Le Moullec, Y. (2018) · IEEE Access · doi:10.1109/access.2018.2853148 · Cited by 272
Trends in miniaturized biosensors for point-of-care testing
Liu, D., Wang, J., Wu, L., Huang, Y., Zhang, Y., Zhu, M., Wang, Y., Zhu, Z., & Yang, C. (2020) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115701 · Cited by 255
Bekker, L.-G., Beyrer, C., Mgodi, N., Lewin, S. R., Delany-Moretlwe, S., Taiwo, B., Masters, M. C., & Lazarus, J. V. (2023) · Nature Reviews Disease Primers · doi:10.1038/s41572-023-00452-3 · Cited by 241
Pashchenko, O., Shelby, T., Banerjee, T., & Santra, S. (2018) · ACS Infectious Diseases · doi:10.1021/acsinfecdis.8b00023 · Cited by 232
Effect of delay in diagnosis on transmission of COVID-19
Rong, X., 1 Center for Mathematical Biosciences, S. O. M. A. S., Yang, L., Chu, H., Fan, M., & 2 National Center for Applied Mathematics (Jilin), N. N. U. (2020) · Mathematical Biosciences and Engineering · doi:10.3934/mbe.2020149 · Cited by 230
The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays
Zhan, L., Guo, S.-Z., Song, F., Gong, Y., Xu, F., Boulware, D. R., McAlpine, M. C., Chan, W. C. W., & Bischof, J. C. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02302 · Cited by 229
Paper-based point-of-care immunoassays: Recent advances and emerging trends
Li, F., You, M., Li, S., Hu, J., Liu, C., Gong, Y., Yang, H., & Xu, F. (2020) · Biotechnology Advances · doi:10.1016/j.biotechadv.2019.107442 · Cited by 222
Recent approaches for optical smartphone sensing in resource-limited settings: a brief review
McCracken, K. E., & Yoon, J.-Y. (2016) · Analytical Methods · doi:10.1039/c6ay01575a · Cited by 216
Juska, V. B., & Pemble, M. E. (2020) · Sensors · doi:10.3390/s20216013 · Cited by 214
Aptamer-based point-of-care diagnostic platforms
Dhiman, A., Kalra, P., Bansal, V., Bruno, J. G., & Sharma, T. K. (2017) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2017.02.060 · Cited by 206
Smartphone‐based clinical diagnostics: towards democratization of evidence‐based health care
Hernández‐Neuta, I., Neumann, F., Brightmeyer, J., Ba Tis, T., Madaboosi, N., Wei, Q., Ozcan, A., & Nilsson, M. (2019) · Journal of Internal Medicine · doi:10.1111/joim.12820 · Cited by 205
Mendelson, M., Røttingen, J.-A., Gopinathan, U., Hamer, D. H., Wertheim, H., Basnyat, B., Butler, C., Tomson, G., & Balasegaram, M. (2016) · The Lancet · doi:10.1016/s0140-6736(15)00547-4 · Cited by 204
James, A., & Macdonald, J. (2015) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.2015.1090877 · Cited by 185
“[36] defined criteria to guide the implementation of rapid molecular assays for use in point-of-care testing.”
BackgroundAdvances in point-of-care technologies for molecular diagnostics
Zarei, M. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.07.024 · Cited by 184
Rapid Diagnostic Testing for SARS-CoV-2
Drain, P. K. (2022) · New England Journal of Medicine · doi:10.1056/nejmcp2117115 · Cited by 176
Self-citationOlusanya, B. O., Ogunlesi, T. A., & Slusher, T. M. (2014) · Archives of Disease in Childhood · doi:10.1136/archdischild-2013-305506 · Cited by 171
Integration of isothermal amplification methods in microfluidic devices: Recent advances
Giuffrida, M. C., & Spoto, G. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.11.045 · Cited by 169
“…and Spoto, 2013; Craw and Balachandran, 2012; Chang et al., 2012) The isothermal process greatly simplifies the implementation of amplification methods in point-of-care diagnostic devices and helps in developing diagnostic assays to be performed in resource-limited settings (Drain et al., 2014).”
Rapid Detection of Mycobacterium tuberculosis by Recombinase Polymerase Amplification
Boyle, D. S., McNerney, R., Teng Low, H., Leader, B. T., Pérez-Osorio, A. C., Meyer, J. C., O'Sullivan, D. M., Brooks, D. G., Piepenburg, O., & Forrest, M. S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103091 · Cited by 164
“The positive predictive value (PPV) and negative predictive value (NPV) are not presented as the contrived composition of the MTBC screening panels used in this study were selected to demonstrate proof of concept and do not reflect the normal distribution of specimens received for routine screening of pulmonary MTBC i…”
MethodBhavnani, S. P., Parakh, K., Atreja, A., Druz, R., Graham, G. N., Hayek, S. S., Krumholz, H. M., Maddox, T. M., Majmudar, M. D., Rumsfeld, J. S., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.018 · Cited by 159
“In 2014 to 2015, over 20 million individuals in the United States sought a virtual healthcare encounter outside of a traditional clinic visitation—through smartphone applications, Internet video– based programs, or retail channels and pharmacy-based clinics (117).”
MethodInfluentialBhavnani, S. P., Sola, S., Adams, D., Venkateshvaran, A., Dash, P. K., Sengupta, P. P., Bhavnani, S., Sola, S., Venkateshvaran, A., Adams, D., et al. (2018) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2017.06.019 · Cited by 81
“Third, a shorter notification rate— the rapid availability of diagnostic information from the point of care and input into electronic medical records—may have improved care coordination, facilitated medical decisions such as early initiation of diuretics for heart failure or rate control and anticoagulation for atrial…”
BackgroundJones, C. H. D., Glogowska, M., Locock, L., & Lasserson, D. S. (2016) · BMC Health Services Research · doi:10.1186/s12913-016-1834-3 · Cited by 49
“ing is being designed increasingly with low-resource settings in mind, the experience of implementing it in these settings is likely to be different from its implementation in developed countries [30].”
BackgroundWorld Heart Federation Cholesterol Roadmap
Murphy, A., Faria-Neto, J. R., Al-Rasadi, K., Blom, D., Catapano, A., Cuevas, A., Lopez-Jimenez, F., Perel, P., Santos, R., Sniderman, A., et al. (2017) · Global Heart · doi:10.1016/j.gheart.2017.03.002 · Cited by 43
Sarantopoulos, A., Mastori Kourmpani, C., Yokarasa, A. L., Makamanzi, C., Antoniou, P., Spernovasilis, N., & Tsioutis, C. (2024) · Tropical Medicine and Infectious Disease · doi:10.3390/tropicalmed9100228 · Cited by 40
“…AI-based diagnostic tools are portable and cost-effective due to their ability to analyze In contrast, AI-based diagnostic tools are portable and cost-effective due to their ability to analyze laboratory samples efficiently and accurately [28]. laboratory samples efficiently and accurately [28].”
BackgroundSaavedra, B., Mambuque, E., Nguenha, D., Gomes, N., Munguambe, S., García, J. I., Izco, S., Acacio, S., Murias-Closas, A., Cossa, M., et al. (2021) · European Respiratory Journal · doi:10.1183/13993003.00257-2021 · Cited by 25
A systematic evaluation of immunoassay point-of-care testing to define impact on patients’ outcomes
Pecoraro, V., Banfi, G., Germagnoli, L., & Trenti, T. (2017) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563217694377 · Cited by 17
“Furthermore, some authors showed as the usefulness of POCT in faster decision-making, influencing treatment and further care,(128) supporting clinical decisions and stratifying patients,(5) but only in specific environments when access to care is limited or in case of environmental disasters.(129,130) The literature e…”
Background
Metadata
- Authors
- Drain, P. K., Hyle, E. P., Noubary, F., Freedberg, K. A., Wilson, D., Bishai, W. R., Rodriguez, W., & Bassett, I. V.
- Venue
- The Lancet Infectious Diseases
- Publisher
- Elsevier BV
- Published
- 2014-03
- Volume
- 14
- Issue
- 3
- Pages
- 239-249
- ISSN
- 1473-3099 (ISSN-L)
- OpenAlex
- W2119525065
- Cited by
- 744
- References
- 117
- FWCI
- 16.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.