High Resolution CZE-MS Quantitative Characterization of Intact Biopharmaceutical Proteins: Proteoforms of Interferon-β1
The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
New and improved methods are required for the enhanced characterization of complex biopharmaceuticals, especially those with charge and glycan heterogeneity. High resolution separation and mass spectrometry (MS) analysis of intact proteoforms can contribute significantly to the characterization of such proteins, many of which are glycoproteins. Here, we report on capillary zone electrophoresis (CZE) coupled via a commercial CESI sheathless interface to an Orbitrap ELITE MS for the intact analysis of recombinant human interferon-β1 (Avonex, rhIFN-β1), a biopharmaceutical with complex glycosylation at a single N-linked site. Using a cross-linked polyethylenimine coating, column efficiencies between 350,000 and 450,000 plates were produced, allowing separation based on charge and subtle hydrodynamic volume differences. A total of 138 proteoforms were found, and 55 were quantitated. Charge species due to deamidation and sialylation were separated by CZE. Given the high column efficiency, isobaric positional isomers of a single sialic acid on biantennary glycan antennae were resolved. Further, triantennary isomers (antenna on α(1-3) or α(1-6) arms) were separated and confirmed by exoglycosidase digestion. Proteoforms of the N-terminal cleavage of methionine were detected by precursor molecular weight and top-down ETD and HCD analysis of the reduced protein. Quantitative analysis suggested potential correlations between the methionine loss with the relative amount of the deamidatio…
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Recent advances in CE-MS platforms have attracted considerable interest from the proteomics community as an alternative to LC-MS9–11.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [11]
In the citing paper
“Notable examples of CZE-MS include the intact mass analysis of biopharmaceutical proteins11 and monoclonal antibodies22,68 where complete baseline separation is often achieved.”
From Recent trends of capillary electrophoresis‐mass spectrometry in proteomics research (2019) · cites this paper as [11]
Citations
Cites
Proteoform: a single term describing protein complexity
The Consortium for Top Down Proteomics, Smith, L. M., & Kelleher, N. L. (2013) · Nature Methods · doi:10.1038/nmeth.2369 · Cited by 1,528
Shinkawa, T., Nakamura, K., Yamane, N., Shoji-Hosaka, E., Kanda, Y., Sakurada, M., Uchida, K., Anazawa, H., Satoh, M., Yamasaki, M., et al. (2003) · Journal of Biological Chemistry · doi:10.1074/jbc.m210665200 · Cited by 1,413
The genomic sequence of the Chinese hamster ovary (CHO)-K1 cell line
Xu, X., Nagarajan, H., Lewis, N. E., Pan, S., Cai, Z., Liu, X., Chen, W., Xie, M., Wang, W., Hammond, S., et al. (2011) · Nature Biotechnology · doi:10.1038/nbt.1932 · Cited by 785
Glycosylation of Recombinant Antibody Therapeutics
Jefferis, R. (2008) · Biotechnology Progress · doi:10.1021/bp040016j · Cited by 526
Polymer wall coatings for capillary electrophoresis
Horvath, J., & Dolník, V. (2001) · ELECTROPHORESIS · doi:10.1002/1522-2683(200102)22:4<644::aid-elps644>3.0.co;2-3 · Cited by 492
Aggregates in monoclonal antibody manufacturing processes
Vázquez‐Rey, M., & Lang, D. A. (2011) · Biotechnology and Bioengineering · doi:10.1002/bit.23155 · Cited by 479
Moini, M. (2007) · Analytical Chemistry · doi:10.1021/ac0704560 · Cited by 322
Certain and Progressive Methylation of Histone H4 at Lysine 20 during the Cell Cycle
Pesavento, J. J., Yang, H., Kelleher, N. L., & Mizzen, C. A. (2008) · Molecular and Cellular Biology · doi:10.1128/mcb.01517-07 · Cited by 289
Iodoacetamide-induced artifact mimics ubiquitination in mass spectrometry
Nielsen, M. L., Vermeulen, M., Bonaldi, T., Cox, J., Moroder, L., & Mann, M. (2008) · Nature Methods · doi:10.1038/nmeth0608-459 · Cited by 286
Takeuchi, M., Inoue, N., Strickland, T. W., Kubota, M., Wada, M., Shimizu, R., Hoshi, S., Kozutsumi, H., Takasaki, S., & Kobata, A. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.20.7819 · Cited by 275
Research works printed but not linked: 1
- 10.1002/1522-2683(200102)22:4<644::AID-ELPS644>3.0.CO;2-3 · DOI · Paper page
Cited by
How many human proteoforms are there?
Aebersold, R., Agar, J. N., Amster, I. J., Baker, M. S., Bertozzi, C. R., Boja, E. S., Costello, C. E., Cravatt, B. F., Fenselau, C., Garcia, B. A., et al. (2018) · Nature Chemical Biology · doi:10.1038/nchembio.2576 · Cited by 907
Self-citationCapillary Electrophoresis: Trends and Recent Advances
Voeten, R. L. C., Ventouri, I. K., Haselberg, R., & Somsen, G. W. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00015 · Cited by 315
The diverse and expanding role of mass spectrometry in structural and molecular biology
Lössl, P., van de Waterbeemd, M., & Heck, A. J. (2016) · The EMBO Journal · doi:10.15252/embj.201694818 · Cited by 222
“…used to profile complex glycosylation patterns even in the presence of other PTMs, as exemplified by the comprehensive analyses of chicken ovalbumin and interferon-b 1, which were shown to consist of 59 and 138 different protein isoforms, respectively (Yang et al , 2013; Bush et al , 2016).”
Top-Down Proteomics: Ready for Prime Time?
Chen, B., Brown, K. A., Lin, Z., & Ge, Y. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b04747 · Cited by 210
Capillary Electrophoresis Separations of Glycans
Lu, G., Crihfield, C. L., Gattu, S., Veltri, L. M., & Holland, L. A. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00669 · Cited by 174
Applications of Raman Spectroscopy in Biopharmaceutical Manufacturing: A Short Review
Buckley, K., & Ryder, A. G. (2017) · Applied Spectroscopy · doi:10.1177/0003702817703270 · Cited by 160
Roberts, D. S., Loo, J. A., Tsybin, Y. O., Liu, X., Wu, S., Chamot-Rooke, J., Agar, J. N., Paša-Tolić, L., Smith, L. M., & Ge, Y. (2024) · Nature Reviews Methods Primers · doi:10.1038/s43586-024-00318-2 · Cited by 161
Recent advances in protein analysis by capillary and microchip electrophoresis
Dawod, M., Arvin, N. E., & Kennedy, R. T. (2017) · The Analyst · doi:10.1039/c7an00198c · Cited by 145
Advances in capillary electrophoresis for the life sciences
Toraño, J. S., Ramautar, R., & de Jong, G. J. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.04.020 · Cited by 132
Glycoproteomics: A Balance between High-Throughput and In-Depth Analysis
Yang, Y., Franc, V., & Heck, A. J. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.04.010 · Cited by 122
Opportunities and challenges of real-time release testing in biopharmaceutical manufacturing
Jiang, M., Severson, K. A., Love, J. C., Madden, H., Swann, P., Zang, L., & Braatz, R. D. (2017) · Biotechnology and Bioengineering · doi:10.1002/bit.26383 · Cited by 118
Self-citationMcCool, E. N., Lubeckyj, R. A., Shen, X., Chen, D., Kou, Q., Liu, X., & Sun, L. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.8b00693 · Cited by 117
Recent applications of capillary electromigration methods to separation and analysis of proteins
Štěpánová, S., & Kašička, V. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2016.06.006 · Cited by 117
“CZE coupled with the commercial CESI sheathless interface to an LTQ Orbitrap MS was used for the analysis of intact recombinant human interferon-b1 (Avonex), a biopharmaceutical used to treat multiple sclerosis [139].”
MethodRecent trends of capillary electrophoresis‐mass spectrometry in proteomics research
Gomes, F. P., & Yates, J. R. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21599 · Cited by 112
Recent advances in CE‐MS coupling: Instrumentation, methodology, and applications
Týčová, A., Ledvina, V., & Klepárník, K. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600366 · Cited by 99
Belov, A. M., Viner, R., Santos, M. R., Horn, D. M., Bern, M., Karger, B. L., & Ivanov, A. R. (2017) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-017-1781-1 · Cited by 97
“In our study, a sheathless cross-linked polyethyleneiminecoated capillary coupled to the Orbitrap Elite MS was used to separate proteoforms of recombinant human interferon-β1 (Avonex), resulting in the detection of 138 proteoforms and the separation of deamidated, sialylated, truncated species, and positional glycofor…”
Self-citationLubeckyj, R. A., McCool, E. N., Shen, X., Kou, Q., Liu, X., & Sun, L. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b02532 · Cited by 96
A five-level classification system for proteoform identifications
Smith, L. M., Thomas, P. M., Shortreed, M. R., Schaffer, L. V., Fellers, R. T., LeDuc, R. D., Tucholski, T., Ge, Y., Agar, J. N., Anderson, L. C., et al. (2019) · Nature Methods · doi:10.1038/s41592-019-0573-x · Cited by 90
Capillary zone electrophoresis-mass spectrometry for top-down proteomics
Shen, X., Yang, Z., McCool, E. N., Lubeckyj, R. A., Chen, D., & Sun, L. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.115644 · Cited by 92
Belov, A. M., Zang, L., Sebastiano, R., Santos, M. R., Bush, D. R., Karger, B. L., & Ivanov, A. R. (2018) · ELECTROPHORESIS · doi:10.1002/elps.201800067 · Cited by 88
Self-citationAnalysis of Mammalian O-Glycopeptides—We Have Made a Good Start, but There is a Long Way to Go
Darula, Z., & Medzihradszky, K. F. (2017) · Molecular & Cellular Proteomics · doi:10.1074/mcp.mr117.000126 · Cited by 87
MS‐based glycomics and glycoproteomics methods enabling isomeric characterization
Peng, W., Reyes, C. D. G., Gautam, S., Yu, A., Cho, B. G., Goli, M., Donohoo, K. B., Mondello, S., Kobeissy, F. H., & Mechref, Y. S. (2021) · Mass Spectrometry Reviews · doi:10.1002/mas.21713 · Cited by 87
Physicochemical characterization of biopharmaceuticals
Parr, M. K., Montacir, O., & Montacir, H. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.05.028 · Cited by 91
“Only recently, Bush et al reported the intact molecule separation by CE-MS [182].”
BackgroundKaur, H., Beckman, J., Zhang, Y., Li, Z. J., Szigeti, M., & Guttman, A. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116407 · Cited by 85
Lubeckyj, R. A., Basharat, A. R., Shen, X., Liu, X., & Sun, L. (2019) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-019-02167-w · Cited by 72
Macedo-da-Silva, J., Santiago, V. F., Rosa-Fernandes, L., Marinho, C. R. F., & Palmisano, G. (2021) · Molecular Immunology · doi:10.1016/j.molimm.2021.04.017 · Cited by 78
Domínguez‐Vega, E., Tengattini, S., Peintner, C., van Angeren, J., Temporini, C., Haselberg, R., Massolini, G., & Somsen, G. W. (2018) · Talanta · doi:10.1016/j.talanta.2018.03.015 · Cited by 67
Haselberg, R., De Vijlder, T., Heukers, R., Smit, M. J., Romijn, E. P., Somsen, G. W., & Domínguez-Vega, E. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.08.024 · Cited by 64
Tassi, M., Vos, J. D., Chatterjee, S., Sobott, F., Bones, J., & Eeltink, S. (2017) · Journal of Separation Science · doi:10.1002/jssc.201700988 · Cited by 67
Choi, S. B., Zamarbide, M., Manzini, M. C., & Nemes, P. (2016) · Journal of the American Society for Mass Spectrometry · doi:10.1007/s13361-016-1532-8 · Cited by 61
Štěpánová, S., & Kašička, V. (2018) · Journal of Separation Science · doi:10.1002/jssc.201801090 · Cited by 59
Kahle, J., & Wätzig, H. (2018) · Electrophoresis · doi:10.1002/elps.201800079 · Cited by 53
Glycan analysis for protein therapeutics
Yang, X., & Bartlett, M. G. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.04.031 · Cited by 54
Franc, V., Yang, Y., & Heck, A. J. R. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04527 · Cited by 51
Life-Saving Threads: Advances in Textile-Based Analytical Devices
Farajikhah, S., Cabot, J. M., Innis, P. C., Paull, B., & Wallace, G. G. (2019) · ACS Combinatorial Science · doi:10.1021/acscombsci.8b00126 · Cited by 48
Camperi, J., Pichon, V., & Delaunay, N. (2019) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2019.112921 · Cited by 51
On the glycosylation aspects of biosimilarity
Hajba, L., Szekrényes, Á., Borza, B., & Guttman, A. (2018) · Drug Discovery Today · doi:10.1016/j.drudis.2018.01.009 · Cited by 47
Mass spectrometry for protein sialoglycosylation
Zhang, Q., Li, Z., Wang, Y., Zheng, Q., & Li, J. (2017) · Mass Spectrometry Reviews · doi:10.1002/mas.21555 · Cited by 41
Jin, Y., Yi, Y., & Yeung, B. (2020) · Methods · doi:10.1016/j.ymeth.2020.08.002 · Cited by 50
Muneeruddin, K., Bobst, C. E., Frenkel, R., Houde, D., Turyan, I., Sosic, Z., & Kaltashov, I. A. (2017) · The Analyst · doi:10.1039/c6an02041k · Cited by 38
Yamamoto, S., Kinoshita, M., & Suzuki, S. (2016) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2016.07.015 · Cited by 40
Füssl, F., Criscuolo, A., Cook, K., Scheffler, K., & Bones, J. (2019) · Journal of Proteome Research · doi:10.1021/acs.jproteome.9b00375 · Cited by 39
Recent progress in the analysis of protein deamidation using mass spectrometry
Ying, Y., & Li, H. (2020) · Methods · doi:10.1016/j.ymeth.2020.06.009 · Cited by 42
Stutz, H. (2022) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2022.115089 · Cited by 38
“Moreover, for some PTMs relations in their occurrence were revealed, e.g., between methionine loss and deamida-tion as well as a negative correlation between the glycan size and the extent of deamidation [337].”
BackgroundRevealing the potential of capillary electrophoresis/mass spectrometry: the tipping point
Gahoual, R., Leize‐Wagner, E., Houzé, P., & François, Y. (2018) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.8238 · Cited by 39
“As a consequence, different CE/MS methods demonstrating the separation and characterization using MS data directly on the intact protein have been reported for various types of biopharmaceutical products.(26,52) In a similar strategy, CE/MS was recently implemented for the characterization of mAbs and ADCs showing in…”
MethodDifferent Stationary Phase Selectivities and Morphologies for Intact Protein Separations
Astefanei, A., Đapić, I., & Camenzuli, M. (2016) · Chromatographia · doi:10.1007/s10337-016-3168-z · Cited by 40
Sánchez‐Hernández, L., Montealegre, C., Kiessig, S., Moritz, B., & Neusüß, C. (2017) · ELECTROPHORESIS · doi:10.1002/elps.201600464 · Cited by 29
Kaltashov, I. A., Ivanov, D. G., & Yang, Y. (2022) · Mass Spectrometry Reviews · doi:10.1002/mas.21829 · Cited by 30
Hamidli, N., Andrási, M., Nagy, C., & Gáspár, A. (2021) · Journal of Chromatography A · doi:10.1016/j.chroma.2021.462448 · Cited by 33
Shen, X., Xu, T., Hakkila, B., Hare, M. G., Wang, Q., Wang, Q., Beckman, J. S., & Sun, L. (2021) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.0c00484 · Cited by 22
Capillary Electrophoresis–Mass Spectrometry for Top-Down Proteomics
Wang, Q., Wang, Q., Zhu, G., & Sun, L. (2025) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071124-092242 · Cited by 24
Szarka, M., Szigeti, M., & Guttman, A. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b01028 · Cited by 21
Römer, J., Stolz, A., Kiessig, S., Moritz, B., & Neusüß, C. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2021.114089 · Cited by 21
Analysis of proteins and chiral drugs based on vancomycin covalent capillary electrophoretic coating
Xing, J., Wang, F., Cong, H., Wang, S., Shen, Y., & Yu, B. (2020) · The Analyst · doi:10.1039/d0an02018d · Cited by 20
Dominguez-Vega, E., De Vijlder, T., Romijn, E. P., & Somsen, G. W. (2017) · Analytica Chimica Acta · doi:10.1016/j.aca.2017.06.021 · Cited by 19
Scapin, G., Çağdaş, E., Grav, L. M., Lewis, N. E., Goletz, S., & Hafkenscheid, L. (2024) · Biotechnology Advances · doi:10.1016/j.biotechadv.2024.108467 · Cited by 19
Tengattini, S., Domínguez‐Vega, E., Temporini, C., Terreni, M., & Somsen, G. W. (2016) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-016-9723-5 · Cited by 17
“CE has shown particularly useful in revealing charge heterogeneity among protein degradation products and impurities, but also has shown the ability to separate positional isomers and conformers [25, 27, 28].”
Wang, F., Cong, H., Xing, J., Wang, S., Shen, Y., & Yu, B. (2020) · Talanta · doi:10.1016/j.talanta.2020.121493 · Cited by 17
Yang, R., Bush, D. R., DeGraan-Weber, N., Barbacci, D. C., Zhang, L., Letarte, S., & Richardson, D. D. (2021) · Journal of Pharmaceutical Sciences · doi:10.1016/j.xphs.2021.08.036 · Cited by 17
Self-citationCE-MS for Proteomics and Intact Protein Analysis
Kuzyk, V., Somsen, G. W., & Haselberg, R. (2021) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-77252-9_4 · Cited by 15
Top-Down Analysis of Branched Proteins Using Mass Spectrometry
Chen, D., Gomes, F., Abeykoon, D., Lemma, B., Wang, Y., Fushman, D., & Fenselau, C. (2018) · Analytical Chemistry · doi:10.1021/acs.analchem.7b05234 · Cited by 14
Are neutral loss and internal product ions useful for top-down protein identification?
Xiao, K., Yu, F., Fang, H., Xue, B., Liu, Y., Li, Y., & Tian, Z. (2017) · Journal of Proteomics · doi:10.1016/j.jprot.2017.03.011 · Cited by 14
Probing protein higher-order structures by native capillary electrophoresis-mass spectrometry
Zhang, W., Xiang, Y., & Xu, W. L. (2022) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2022.116739 · Cited by 14
Wang, Q., Gao, G., Fang, F., Wang, Q., Lundquist, P. K., & Sun, L. (2024) · Analytica Chimica Acta · doi:10.1016/j.aca.2024.343162 · Cited by 13
Blevins, M. S., Juetten, K. J., James, V. K., Butalewicz, J. P., Escobar, E. E., Lanzillotti, M. B., Sanders, J. D., Fort, K. L., & Brodbelt, J. S. (2022) · Journal of Proteome Research · doi:10.1021/acs.jproteome.2c00450 · Cited by 15
Intact Proteoform Analysis by Capillary Electrophoresis–Mass Spectrometry. Are We There Yet?
Gould, N., Wang, Q., Agar, J. N., Brodbelt, J. S., Chen, D., Cupp‐Sutton, K. A., Domínguez‐Vega, E., Fang, F., Fillet, M., Fischer, M. S., et al. (2025) · Angewandte Chemie International Edition · doi:10.1002/anie.202518366 · Cited by 16
Self-citationGreguš, M., Gao, Y., Johnson, K. R., Ray, S., Marie, A., & Ivanov, A. R. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.4c06727 · Cited by 10
Self-citationHöchsmann, A., Frick, H., Dhellemmes, L., Leclercq, L., Kaulich, P. T., Tholey, A., Cottet, H., Schaschke, N., & Neusüß, C. (2025) · PROTEOMICS · doi:10.1002/pmic.70012 · Cited by 8
Biopharmaceutical Applications of Capillary Electromigration Methods
Gahoual, R., Giorgetti, J., Beck, A., Leize‐Wagner, E., & François, Y. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-809375-7.00021-6 · Cited by 10
LC-MS/MS in glycomics and glycoproteomics analyses
Goli, M., Yu, A., Cho, B. G., Gautam, S., Wang, J., Reyes, C. D. G., Jiang, P., Peng, W., & Mechref, Y. S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821447-3.00005-6 · Cited by 11
Tomašovský, R., Opetová, M., Havlikova, J., Mikuš, P., & Maráková, K. (2023) · Electrophoresis · doi:10.1002/elps.202300089 · Cited by 8
Khan, J. U., Sayyar, S., Jin, D., Paull, B., & Innis, P. C. (2022) · Microfluidics and Nanofluidics · doi:10.1007/s10404-022-02603-6 · Cited by 8
Madren, S. M., & Yi, L. (2022) · Electrophoresis · doi:10.1002/elps.202200129 · Cited by 6
Khan, J. U., Pathan, M. A., Sayyar, S., Paull, B., & Innis, P. C. (2023) · Analytical Methods · doi:10.1039/d2ay01714h · Cited by 5
Coated Capillaries for CE-MS of Therapeutic Protein
Xia, J. Q. (2016) · Springer eBooks · doi:10.1007/978-3-319-46240-0_2 · Cited by 4
“Instead of using regular polyethylenimine coated capillary, a cross-linked polyethylenimine coating has been recently reported to be used on the quantitative CE-MS analysis of intact Interferon-β1 proteoforms [12].”
MethodCapillary electrophoresis-mass spectrometry of carbohydrates and glycoconjugates
do Lago, C. L., Daniel, D., Lopes, F. S., & Cieslarová, Z. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821447-3.00016-0 · Cited by 4
Gao, G., Fang, F., Yue, Y., Zhang, A. T., Wang, Q., Wang, Q., Zhu, G., & Sun, L. (2025) · Journal of Mass Spectrometry · doi:10.1002/jms.70005 · Cited by 3
Zhu, G., Rodriguez, D. A. A., Gould, N., Ivanov, A. R., Jooß, K., & Sun, L. (2026) · Mass Spectrometry Reviews · doi:10.1002/mas.70028 · Cited by 4
Self-citationGould, N., Johnson, K. R., Marie, A., Auclair, J. R., & Ivanov, A. R. (2025) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2025.117309 · Cited by 2
Self-citationIntact Proteoform Analysis by Capillary Electrophoresis–Mass Spectrometry. Are We There Yet?
Gould, N., Wang, Q., Agar, J. N., Brodbelt, J. S., Chen, D., Cupp‐Sutton, K. A., Domínguez‐Vega, E., Fang, F., Fillet, M., Fischer, M. S., et al. (2025) · Angewandte Chemie · doi:10.1002/ange.202518366 · Cited by 2
Self-citationWang, Q., Wang, Q., Melani, R. D., Liu, Q., Nurmi, P., & Sun, L. (2026) · Journal of the American Society for Mass Spectrometry · doi:10.1021/jasms.5c00384 · Cited by 1
Shaji, K. K., Horvatovich, P. L., & Lageveen‐Kammeijer, G. S. M. (2026) · The Analyst · doi:10.1039/d6an00304d · Cited by 2
Chromatography (other than size-exclusion chromatography) and electrophoresis
Berkowitz, S. A. (2019) · Elsevier eBooks · doi:10.1016/b978-0-444-64173-1.00014-7 · Cited by 1
Capillary electrophoresis of glycoproteins
Puerta, A., Gomez-Ruiz, L., Díez‐Masa, J. C., & de Frutos, M. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-821447-3.00009-3 · Cited by 1
Characterization of Intact Therapeutics and Protein Subunits Using CE-MS Platform
Wang, W. (2016) · Springer eBooks · doi:10.1007/978-3-319-46240-0_7
Mass Spectrometric Characterization of Recombinant Proteins
Bakalarski, C. E., Sandoval, W. N., & Lill, J. R. (2017) · Wiley eBooks · doi:10.1002/9781119384434.ch2
Trendbericht: Analytische Chemie 2016/2017
Huber, C. G., Pagel, K., Hoffmann, W., Heiles, S., Schäfer, K. C., Kompauer, M., Gerbig, S., & Soltwisch, J. (2018) · Nachrichten aus der Chemie · doi:10.1002/nadc.20184070741
Holland, L., & Bennett, C. E. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-819475-1.00029-8
Dadouch, M. (2020) · theses.fr (ABES) · doi:10.70675/f003c2c2z07e0z4998zbd14zada08cd1ae13
Metadata
- Authors
- Bush, D. R., Zang, L., Belov, A. M., Ivanov, A. R., & Karger, B. L.
- Affiliations
- Northeastern University (US)
- Biogen (United States) (US)
- Corresponding author
- Karger, Barry L.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 2015-12-24
- Volume
- 88
- Issue
- 2
- Pages
- 1138-1146
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2233468065
- Cited by
- 92
- References
- 55
- Citations by year
- 2026: 3 · 2025: 7 · 2024: 3 · 2023: 2 · 2022: 7 · 2021: 11 · 2020: 6 · 2019: 12 · 2018: 15 · 2017: 14 · 2016: 12
- FWCI
- 6.08
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Analytical Chemistry (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Biogen
- Thermo Fisher Scientific Inc.
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Glycosylation and Glycoproteins Research
- Keywords
- Avonex, proteoforms, capillary zone electrophoresis, glycoproteins, N-glycosylation, deamidation, sialylation, column efficiency, methionine cleavage, top-down mass spectrometry, biopharmaceutical characterization, glycan heterogeneity
- MeSH terms
- Humans, Mass Spectrometry, Interferon-beta, Electrophoresis, Capillary, Biosimilar Pharmaceuticals
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.