CoChat

Combination of Polypropylene Mesh and in Situ Injectable Mussel-Inspired Hydrogel in Laparoscopic Hernia Repair for Preventing Post-Surgical Adhesions in the Piglet Model

Hu, Wanjun, Zhang, Zhigang, Zhu, Long, Wen, Yazhou, Zhang, Tianzhu, Ren, Pengfei, Wang, Faming, Ji, Zhenling · 2020 · ACS Biomaterials Science & Engineering
Cited by 44

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

Polypropylene (PP) mesh has been used successfully for a long time in clinical practice as an impressive prosthesis for ventral hernia repair. To utilize a physical barrier for separating mesh from viscera is a general approach for preventing adhesions in clinical practice. However, a serious abdominal adhesion between the mesh and viscera can possibly occur post-hernia, especially with the small intestine; this can lead to a series of complications, such as chronic pain, intestinal obstruction, and fistula. Thus, determining how to prevent abdominal adhesions between the mesh and viscera is still an urgent clinical problem. In this study, a dopamine-functionalized polysaccharide derivative (oxidized-carboxymethylcellulose- g -dopamine, OCMC-DA) was synthesized; this was blended with carboxymethylchitosan (CMCS) to form a hydrogel (OCMC-DA/CMCS) in situ at the appropriate time. The physical and chemical properties of the hydrogel were characterized successfully, and its excellent biocompatibility was presented by the in vitro cell test. The combination of this hydrogel and PP mesh was used in laparoscopic surgery for repairing the abdominal wall defect, where the hydrogel could become fixed in situ on the PP mesh to form an anti-adhesion gel-mesh. The results showed that the gel-mesh could prevent abdominal adhesions effectively in the piglet model. Moreover, the histology and immunohistochemical staining proved that the gel-mesh could effectively alleviate the inflammation reaction and deposition of collagen around the mesh, and it did not disturb the integration between mesh and abdominal wall. Thus, the gel-mesh has superior tissue compatibility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsbiomaterials.9b01333

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 44

Metadata

Authors
Hu, W., Zhang, Z., Zhu, L., Wen, Y., Zhang, T., Ren, P., Wang, F., & Ji, Z.
Venue
ACS Biomaterials Science & Engineering
Published
2020-02-04
Volume
6
Issue
3
Pages
1735-1743
ISSN
2373-9878 (ISSN-L)
OpenAlex
W3005524172
Cited by
44
References
10
FWCI
5.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Combination of Polypropylene Mesh and in Situ Injectable Mussel-Inspired Hydrogel in Laparoscopic Hernia Repair for Preventing Post-Surgical Adhesions in the Piglet Model. https://app.cochat.ai/papers/10.1021/acsbiomaterials.9b01333
The paper
Hu, W., Zhang, Z., Zhu, L., Wen, Y., Zhang, T., Ren, P., Wang, F., & Ji, Z. (2020). Combination of Polypropylene Mesh and in Situ Injectable Mussel-Inspired Hydrogel in Laparoscopic Hernia Repair for Preventing Post-Surgical Adhesions in the Piglet Model. ACS Biomaterials Science & Engineering. https://doi.org/10.1021/acsbiomaterials.9b01333

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.