The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Wearable Flexible and Stretchable Glove Biosensor for On-Site Detection of Organophosphorus Chemical Threats
Open accessAbstract
A flexible glove-based electrochemical biosensor with highly stretchable printed electrode system has been developed as a wearable point-of-use screening tool for defense and food security applications. This disposable-mechanically robust "lab-on-a-glove" integrates a stretchable printable enzyme-based biosensing system and active surface for swipe sampling on different fingers, and is coupled with a compact electronic interface for electrochemical detection and real-time wireless data transmission to a smartphone device. Stress-enduring inks are used to print the electrode system and the long serpentine connections to the wireless electronic interface. Dynamic mechanical deformation, bending, and stretching studies illustrate the resilience and compliance of the printed traces against extreme mechanical deformations expected for such on-glove sampling/sensing operation. An organophosphorus hydrolase (OPH)-based biosensor system on the index finger enables rapid on-site detection of organophosphate (OP) nerve-agent compounds on suspicious surfaces and agricultural products following their swipe collection on the thumb finger. The new wireless glove-based biosensor system offers considerable promise for field screening of OP nerve-agents and pesticides in defense and food-safety applications, with significant speed and cost advantages. Such "lab-on-a-glove" demonstration opens the area of flexible wearable sensors to future on-the-hand multiplexed chemical detection in diverse fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Self-citationElectrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Self-citationWearable Chemical Sensors: Present Challenges and Future Prospects
Bandodkar, A. J., Jeerapan, I., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00250 · Cited by 778
Self-citationOrganophosphates⧸Nerve Agent Poisoning: Mechanism of Action, Diagnosis, Prophylaxis, And Treatment
(2004) · Advances in Clinical Chemistry · doi:10.1016/s0065-2423(04)38006-6 · Cited by 701
Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study
Bandodkar, A. J., Jia, W., Yardımcı, C., Wang, X., Ramirez, J., & Wang, J. (2015) · Analytical Chemistry · doi:10.1021/ac504300n · Cited by 700
Self-citationWearable salivary uric acid mouthguard biosensor with integrated wireless electronics
Kim, J., Imani, S., de Araujo, W. R., Warchall, J., Valdés-Ramírez, G., Paixão, T. R. L. C., Mercier, P. P., & Wang, J. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.07.039 · Cited by 678
Self-citationLehotay, S. J., Kok, A. D., Hiemstra, M., & Bodegraven, P. V. (2005) · Journal of AOAC INTERNATIONAL · doi:10.1093/jaoac/88.2.595 · Cited by 662
Noninvasive Alcohol Monitoring Using a Wearable Tattoo-Based Iontophoretic-Biosensing System
Kim, J., Jeerapan, I., Imani, S., Cho, T. N., Bandodkar, A., Cinti, S., Mercier, P. P., & Wang, J. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00356 · Cited by 599
Self-citationNon-invasive mouthguard biosensor for continuous salivary monitoring of metabolites
Kim, J., Valdés-Ramírez, G., Bandodkar, A. J., Jia, W., Martinez, A. G., Ramírez, J., Mercier, P., & Wang, J. (2014) · The Analyst · doi:10.1039/c3an02359a · Cited by 367
Self-citationBandodkar, A. J., Jeerapan, I., You, J.-M., Nuñez-Flores, R., & Wang, J. (2016) · Nano Letters · doi:10.1021/acs.nanolett.5b04549 · Cited by 341
Self-citationStretchable biofuel cells as wearable textile-based self-powered sensors
Jeerapan, I., Sempionatto, J. R., Pavinatto, A., You, J.-M., & Wang, J. (2016) · Journal of Materials Chemistry A · doi:10.1039/c6ta08358g · Cited by 317
Self-citationTattoo‐Based Wearable Electrochemical Devices: A Review
Bandodkar, A. J., Jia, W., & Wang, J. (2015) · Electroanalysis · doi:10.1002/elan.201400537 · Cited by 312
Self-citationZhang, W., Asiri, A. M., Liu, D., Du, D., & Lin, Y. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.10.007 · Cited by 270
Kumar, R., Shin, J., Yin, L., You, J., Meng, Y. S., & Wang, J. (2017) · Advanced Energy Materials · doi:10.1002/aenm.201602096 · Cited by 261
Self-citationSharma, D., Nagpal, A., Pakade, Y. B., & Katnoria, J. K. (2010) · Talanta · doi:10.1016/j.talanta.2010.06.043 · Cited by 256
Yao, H., Liao, Y., Lingley, A. R., Afanasiev, A., Lähdesmäki, I., Otis, B. P., & Parviz, B. A. (2012) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/22/7/075007 · Cited by 182
Evolution of an organophosphate-degrading enzyme: a comparison of natural and directed evolution
Yang, H., Carr, P. D., McLoughlin, S. Y., Liu, J. W., Horne, I., Qiu, X., Jeffries, C. M. J., Russell, R. J., Oakeshott, J. G., & Ollis, D. L. (2003) · Protein Engineering, Design and Selection · doi:10.1093/proeng/gzg013 · Cited by 162
All-printed magnetically self-healing electrochemical devices
Bandodkar, A. J., Silva‐López, C., Mohan, A. M. V., Yin, L., Kumar, R., & Wang, J. (2016) · Science Advances · doi:10.1126/sciadv.1601465 · Cited by 137
Self-citationPankratov, D., González‐Arribas, E., Blum, Z., & Shleev, S. (2016) · Electroanalysis · doi:10.1002/elan.201501116 · Cited by 135
Zuliani, C., & Diamond, D. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.04.147 · Cited by 131
Wearable electrochemical sensors for in situ analysis in marine environments
Malzahn, K., Windmiller, J. R., Valdés‐Ramírez, G., Schöning, M. J., & Wang, J. (2011) · The Analyst · doi:10.1039/c1an15193b · Cited by 129
Self-citationde Jong, M., Sleegers, N., Kim, J., Durme, F. V., Samyn, N., Wang, J., & Wael, K. D. (2016) · Chemical Science · doi:10.1039/c5sc04309c · Cited by 127
Self-citationTechnological leap for sweat sensing
Heikenfeld, J. C. (2016) · Nature · doi:10.1038/529475a · Cited by 121
The environmental fate of organophosphorus nerve agents: A review
Kingery, A. F., & Allen, H. E. (1995) · Toxicological & Environmental Chemistry Reviews · doi:10.1080/02772249509358137 · Cited by 117
Wireless Hazard Badges to Detect Nerve‐Agent Simulants
Zhu, R., Azzarelli, J. M., & Swager, T. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201604431 · Cited by 86
Wang, J., Krause, R., Block, K., Musameh, M. M., Mulchandani, A., & Schöning, M. J. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00178-1 · Cited by 83
Self-citationBandodkar, A. J., O’Mahony, A., Ramírez, J., Samek, I. A., Anderson, S. M., Windmiller, J. R., & Wang, J. (2013) · The Analyst · doi:10.1039/c3an01179h · Cited by 80
Self-citationRecent Advances in Electrochemical Sensors for Detecting Weapons of Mass Destruction. A Review
Singh, V. V. (2016) · Electroanalysis · doi:10.1002/elan.201501088 · Cited by 51
Wearable Woven Electrochemical Biosensor Patch for Non‐invasive Diagnostics
Modali, A., Vanjari, S. R. K., & Dendukuri, D. (2016) · Electroanalysis · doi:10.1002/elan.201600041 · Cited by 51
Cánovas, R., Parrilla, M., Mercier, P. P., Andrade, F. J., & Wang, J. (2016) · Advanced Materials Technologies · doi:10.1002/admt.201600061 · Cited by 32
Self-citationWireless Hazard Badges to Detect Nerve‐Agent Simulants
Zhu, R., Azzarelli, J. M., & Swager, T. M. (2016) · Angewandte Chemie · doi:10.1002/ange.201604431 · Cited by 10
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
Disposable Sensors in Diagnostics, Food, and Environmental Monitoring
Dincer, C., Bruch, R., Costa‐Rama, E., Fernández‐Abedul, M. T., Merkoçi, A., Manz, A., Urban, G. A., & Güder, F. (2019) · Advanced Materials · doi:10.1002/adma.201806739 · Cited by 955
Shi, Q., Dong, B., He, T., Sun, Z., Zhu, J., Zhang, Z., & Lee, C. (2020) · InfoMat · doi:10.1002/inf2.12122 · Cited by 661
Evolution of Wearable Devices with Real-Time Disease Monitoring for Personalized Healthcare
Guk, K., Han, G., Lim, J., Jeong, K., Kang, T., Lim, E.-K., & Jung, J. (2019) · Nanomaterials · doi:10.3390/nano9060813 · Cited by 624
Umapathi, R., Ghoreishian, S. M., Sonwal, S., Rani, G. M., & Huh, Y. S. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214305 · Cited by 547
Metadata
- Authors
- Mishra, R. K., Hubble, L. J., Martín, A., Kumar, R., Barfidokht, A., Kim, J., Musameh, M. M., Kyratzis, I. L., & Wang, J.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-03-17
- Volume
- 2
- Issue
- 4
- Pages
- 553-561
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2592375018
- Cited by
- 345
- References
- 33
- FWCI
- 14.99
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.