Li, Jin, Dong, Yan, Wei, Ruwei, Jiang, Guanyu, Yao, Cheng, Lv, Meng, Wu, Yuyang, Gardner, Sarah H., Zhang, Feng, Lucero, Melissa Y., Huang, Jian, Chen, Hao, Ge, Guangbo, Chan, Jefferson, Chen, Jinquan, Sun, Haitao, Luo, Xiao, Qian, Xuhong, Yang, Youjun · 2022 · Journal of the American Chemical Society
Cited by 156

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

Near-infrared (NIR) fluorophores absorbing maximally in the region beyond 800 nm, i.e., deep-NIR spectral region, are actively sought for biomedical applications. Ideal dyes are bright, nontoxic, photostable, biocompatible, and easily derivatized to introduce functionalities (e.g., for bioconjugation or aqueous solubility). The rational design of such fluorophores remains a major challenge. Silicon-substituted rhodamines have been successful for bioimaging applications in the red spectral region. The longer-wavelength silicon-substituted congeners for the deep-NIR spectral region are unknown to date. We successfully prepared four silicon-substituted bis-benzannulated rhodamine dyes ( ESi5a–ESi5d ), with an efficient five-step cascade on a gram-scale. Because of the extensive overlapping of their HOMO–LUMO orbitals, ESi5a–ESi5d are highly absorbing (λ abs ≈ 865 nm and ε > 10 5 cm –1 M –1 ). By restraining both the rotational freedom via annulation and the vibrational freedom via silicon-imparted strain, the fluorochromic scaffold of ESi5 is highly rigid, resulting in an unusually long fluorescence lifetime (τ > 700 ps in CH 2 Cl 2 ) and a high fluorescence quantum yield (ϕ = 0.14 in CH 2 Cl 2 ). Their half-lives toward photobleaching are 2 orders of magnitude longer than the current standard (ICG in serum). They are stable in the presence of biorelevant concentration of nucleophiles or reactive oxygen species. They are minimally toxic and readily metabolized. Upon tail vein injection of ESi5a (as an example), the vasculature of a nude mouse was imaged with a high signal-to-background ratio. ESi5 dyes have broad potentials for bioimaging in the deep-NIR spectral region.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/jacs.2c05826

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 22 references

Cited by

See all 156

Metadata

Authors
Li, J., Dong, Y., Wei, R., Jiang, G., Yao, C., Lv, M., Wu, Y., Gardner, S. H., Zhang, F., Lucero, M. Y., Huang, J., Chen, H., Ge, G., Chan, J., Chen, J., Sun, H., Luo, X., Qian, X., & Yang, Y.
Venue
Journal of the American Chemical Society
Published
2022-07-29
Volume
144
Issue
31
Pages
14351-14362
ISSN
  • 0002-7863 (ISSN-L)
  • 1520-5126
OpenAlex
W4288714484
Cited by
156
References
22
FWCI
9.04
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Stable, Bright, and Long-Fluorescence-Lifetime Dyes for Deep-Near-Infrared Bioimaging. https://app.cochat.ai/papers/10.1021/jacs.2c05826
The paper
Li, J., Dong, Y., Wei, R., Jiang, G., Yao, C., Lv, M., Wu, Y., Gardner, S. H., Zhang, F., Lucero, M. Y., Huang, J., Chen, H., Ge, G., Chan, J., Chen, J., Sun, H., Luo, X., Qian, X., & Yang, Y. (2022). Stable, Bright, and Long-Fluorescence-Lifetime Dyes for Deep-Near-Infrared Bioimaging. Journal of the American Chemical Society. https://doi.org/10.1021/jacs.2c05826

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.