X-ray-Induced Shortwave Infrared Biomedical Imaging Using Rare-Earth Nanoprobes
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Shortwave infrared (SWIR or NIR-II) light provides significant advantages for imaging biological structures due to reduced autofluorescence and photon scattering. Here, we report on the development of rare-earth nanoprobes that exhibit SWIR luminescence following X-ray irradiation. We demonstrate the ability of X-ray-induced SWIR luminescence (X-IR) to monitor biodistribution and map lymphatic drainage. Our results indicate X-IR imaging is a promising new modality for preclinical applications and has potential for dual-modality molecular disease imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688
A route to brightly fluorescent carbon nanotubes for near-infrared imaging in mice
Welsher, K., Liu, Z., Sherlock, S. P., Robinson, J. T., Chen, Z., Daranciang, D., & Dai, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.294 · Cited by 1,287
Multifunctional in vivo vascular imaging using near-infrared II fluorescence
Hong, G., Lee, J. C., Robinson, J. T., Raaz, U., Xie, L., Huang, N. F., Cooke, J. P., & Dai, H. (2012) · Nature Medicine · doi:10.1038/nm.2995 · Cited by 995
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Cited by
Reactive oxygen species generating systems meeting challenges of photodynamic cancer therapy
Zhou, Z., Song, J., Nie, L., & Chen, X. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00271d · Cited by 2,098
Carbon Nanomaterials for Biological Imaging and Nanomedicinal Therapy
Hong, G., Diao, S., Antaris, A. L., & Dai, H. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00008 · Cited by 1,394
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
Near‐Infrared‐II Molecular Dyes for Cancer Imaging and Surgery
Zhu, S., Tian, R., Antaris, A. L., Chen, X., & Dai, H. (2019) · Advanced Materials · doi:10.1002/adma.201900321 · Cited by 972
Recent Advances of Optical Imaging in the Second Near‐Infrared Window
Kenry, Duan, Y., & Liu, B. (2018) · Advanced Materials · doi:10.1002/adma.201802394 · Cited by 810
Near-infrared luminescence high-contrast in vivo biomedical imaging
Chen, Y., Wang, S., & Zhang, F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00002-8 · Cited by 566
In vivo NIR-II fluorescence imaging for biology and medicine
Wang, F., Zhong, Y., Bruns, O., Liang, Y., & Dai, H. (2024) · Nature Photonics · doi:10.1038/s41566-024-01391-5 · Cited by 564
“NIR-II wide-field fluorescence imaging employs an excitation source such as an expanded laser beam 11 , a light-emitting diode (LED) 23 , an X-ray beam 61 or Cerenkov radiation 62 (Fig.”
X-ray-activated nanosystems for theranostic applications
Chen, X., Song, J., Chen, X., & Yang, H. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00921j · Cited by 401
Traumatic Brain Injury Imaging in the Second Near‐Infrared Window with a Molecular Fluorophore
Zhang, X., Wang, H., Antaris, A. L., Li, L., Diao, S., Ma, R., Nguyen, A., Hong, G., Ma, Z., Wang, J., et al. (2016) · Advanced Materials · doi:10.1002/adma.201600706 · Cited by 386
Scintillating Nanoparticles as Energy Mediators for Enhanced Photodynamic Therapy
Kamkaew, A., Chen, F., Zhan, Y., Majewski, R. L., & Cai, W. (2016) · ACS Nano · doi:10.1021/acsnano.6b01401 · Cited by 355
Imaging and therapeutic applications of persistent luminescence nanomaterials
Liu, J., Lécuyer, T., Seguin, J., Mignet, N., Scherman, D., Viana, B., & Richard, C. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.10.015 · Cited by 313
Xu, J., Gulzar, A., Yang, P., Bi, H., Yang, D., Gai, S., He, F., Lin, J., Xing, B., & Jin, D. (2019) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2018.11.014 · Cited by 310
Near-Infrared-II (NIR-II) Bioimaging via Off-Peak NIR-I Fluorescence Emission
Zhu, S., Yung, B. C., Chandra, S., Niu, G., Antaris, A. L., & Chen, X. (2018) · Theranostics · doi:10.7150/thno.27995 · Cited by 303
Zhu, S., Yang, Q., Antaris, A. L., Yue, J., Ma, Z., Wang, H., Huang, W., Wan, H., Wang, J., Diao, S., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1617990114 · Cited by 279
Chen, C., Tian, R., Zeng, Y., Chu, C., & Liu, G. (2020) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.9b00734 · Cited by 215
Photophysical Tuning of Shortwave Infrared Flavylium Heptamethine Dyes via Substituent Placement
Pengshung, M., Li, J., Mukadum, F., Lopez, S. A., & Sletten, E. M. (2020) · Organic Letters · doi:10.1021/acs.orglett.0c02213 · Cited by 42
Metadata
- Authors
- Naczynski, D. J., Sun, C., Türkcan, S., Jenkins, C., Koh, A. L., Ikeda, D., Pratx, G., & Xing, L.
- Venue
- Nano Letters
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-12-15
- Volume
- 15
- Issue
- 1
- Pages
- 96-102
- ISSN
- 1530-6984 (ISSN-L)
- 1530-6992
- OpenAlex
- W2325139724
- Cited by
- 140
- References
- 5
- FWCI
- 3.57
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.