CoChat

Reducing uncertainties in carbonate clumped isotope analysis through consistent carbonate-based standardization

Open access

The DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.

Abstract

About a decade after its introduction, the field of carbonate clumped isotope thermometry is rapidly expanding because of the large number of possible applications and its potential to solve long‐standing questions in Earth Sciences. Major factors limiting the application of this method are the very high analytical precision required for meaningful interpretations, the relatively complex sample preparation procedures, and the mass spectrometric corrections needed. In this paper we first briefly review the evolution of the analytical and standardization procedures and discuss the major remaining sources of uncertainty. We propose that the use of carbonate standards to project the results to the carbon dioxide equilibrium scale can improve interlaboratory data comparability and help to solve long‐standing discrepancies between laboratories and temperature calibrations. The use of carbonates reduces uncertainties related to gas preparation and cleaning procedures and ensures equal treatment of samples and standards. We present a set of carbonate standards of diverse composition, discuss how they can be used to correct for mass spectrometric biases, and demonstrate that their use significantly improves the comparability among four laboratories. We propose that the use of these standards or of a similar set of carbonate standards will improve the comparability of data across laboratories.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1029/2017gc007385

Cites

62 of 62 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1 Reference frames obtained by Schauer et al. (2016) using two gases with different δ 13C (FF and FC), showing the effect of the calculations using the parameters as in Huntington et al. (2009) (a) and the Assonov and Brenninkmeijer (2003) 17R values and the λ value of Meijer and Li (1998) (b). Note that the differences disappear in Figure 1b. (Reproduced with permission from John Wiley & Sons, Inc.)
Figure 1 Reference frames obtained by Schauer et al. (2016) using two gases with different δ 13C (FF and FC), showing the effect of the calculations using the parameters as in Huntington et al. (2009) (a) and the Assonov and Brenninkmeijer (2003) 17R values and the λ value of Meijer and Li (1998) (b). Note that the differences disappear in Figure 1b. (Reproduced with permission from John Wiley & Sons, Inc.)CC BY-NC-ND · PubMed Central
Figure 2 Difference in Δ47 calculated as the difference between the value obtained using the Brand parameters and the one using the Huntington parameters, expressed as Δ (Δ47) when fixing δ 13C and changing δ 18O (a) and fixing δ 18O but changing δ 13C (b). The diagrams are calculated for the composition of the ETH working gas using equation (10) in Daëron et al. (2016). Note the opposite effect in carbon versus oxygen isotope ratios. VPDB = Vienna Peedee belemnite.
Figure 2 Difference in Δ47 calculated as the difference between the value obtained using the Brand parameters and the one using the Huntington parameters, expressed as Δ (Δ47) when fixing δ 13C and changing δ 18O (a) and fixing δ 18O but changing δ 13C (b). The diagrams are calculated for the composition of the ETH working gas using equation (10) in Daëron et al. (2016). Note the opposite effect in carbon versus oxygen isotope ratios. VPDB = Vienna Peedee belemnite.CC BY-NC-ND · PubMed Central
Figure 3 Schematic representation of the isotopic composition of the four ETH standards against a WG with δ 13C of −7.2‰ and δ 18O of 0.65‰ VPDB. The arrows show the change in composition that would be observed from erroneous (a) overcorrection or (b) undercorrection of the negative backgrounds. This is a very robust method to verify the quality of the correction. Contamination by isobaric interferences would increase the Δ47 of all four standards. VPDB = Vienna Peedee belemnite; WG = working gas.
Figure 3 Schematic representation of the isotopic composition of the four ETH standards against a WG with δ 13C of −7.2‰ and δ 18O of 0.65‰ VPDB. The arrows show the change in composition that would be observed from erroneous (a) overcorrection or (b) undercorrection of the negative backgrounds. This is a very robust method to verify the quality of the correction. Contamination by isobaric interferences would increase the Δ47 of all four standards. VPDB = Vienna Peedee belemnite; WG = working gas.CC BY-NC-ND · PubMed Central
Figure 4 Evolution of the slope and intercept of the Thermo 253Plus at ETH between 24 February and 29 March 2016. Note the fluctuations in both slope and intercept that can be traced with a 2‐day resolution with the repeated measurements of the standards. ETF = empirical transfer function.
Figure 4 Evolution of the slope and intercept of the Thermo 253Plus at ETH between 24 February and 29 March 2016. Note the fluctuations in both slope and intercept that can be traced with a 2‐day resolution with the repeated measurements of the standards. ETF = empirical transfer function.CC BY-NC-ND · PubMed Central
Figure 5 Comparison of the original Kele et al. (2015) calibration (gray dashed line) with the Kelson et al. (2017) calibration (black line) and the recalculated Kele et al. (2015) using the Brand parameters and projection of the data to the reference frame using the University of Washington values (Schauer et al., 2016) for the ETH standards (green line). CDES = carbon dioxide equilibrium scale.
Figure 5 Comparison of the original Kele et al. (2015) calibration (gray dashed line) with the Kelson et al. (2017) calibration (black line) and the recalculated Kele et al. (2015) using the Brand parameters and projection of the data to the reference frame using the University of Washington values (Schauer et al., 2016) for the ETH standards (green line). CDES = carbon dioxide equilibrium scale.CC BY-NC-ND · PubMed Central
Figure 6 Comparison of the Cambridge calibration calculated with normalization to heated and equilibrated gases (orange diamonds) and the normalization against the ETH carbonate standards (Blue dots). Between 12 and 21 carbonate standards were measured with every batch of 46 samples that can be accommodated in the Kiel device. The black line is the Kele et al. (2015) calibration recalculated with the Brand parameters. CDES = carbon dioxide equilibrium scale.
Figure 6 Comparison of the Cambridge calibration calculated with normalization to heated and equilibrated gases (orange diamonds) and the normalization against the ETH carbonate standards (Blue dots). Between 12 and 21 carbonate standards were measured with every batch of 46 samples that can be accommodated in the Kiel device. The black line is the Kele et al. (2015) calibration recalculated with the Brand parameters. CDES = carbon dioxide equilibrium scale.CC BY-NC-ND · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

12 more claims about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 1

  1. 10.1002/1097‐0231(20000630)14:12<1044::AID‐RCM987>3.0.CO;2‐3 · doi:10.1002/1097-0231(20000630)14:12<1044::aid-rcm987>3.0.co;2-3

Cited by

See all 301

Metadata

Authors
Bernasconi, S. M., Müller, I. A., Bergmann, K. D., Breitenbach, S. F. M., Fernandez, A., Hodell, D. A., Jaggi, M., Meckler, A. N., Millan, I., & Ziegler, M.
Affiliations
  • ETH Zurich (CH)
  • Massachusetts Institute of Technology (US)
  • University of Cambridge (GB)
  • Geological Institute ETH Zürich Zürich Switzerland
  • Bjerknes Centre for Climate Research (NO)
  • Utrecht University (NL)
Corresponding author
Bernasconi, Stefano M.
Venue
Geochemistry, Geophysics, Geosystems
Published
2018-09
Volume
19
Issue
9
Pages
2895-2914
ISSN
1525-2027 (ISSN-L)
OpenAlex
W2885555794
Cited by
301
References
62
Citations by year
2026: 21 · 2025: 36 · 2024: 40 · 2023: 33 · 2022: 43 · 2021: 58 · 2020: 35 · 2019: 28 · 2018: 6
FWCI
15.50
Type
journal article
Language
en
Open access
Locations
  • Geochemistry Geophysics Geosystems (publishedVersion, cc-by-nc-nd)
  • Europe PMC (PubMed Central) (publishedVersion, other-oa)
  • PubMed Central (publishedVersion, cc-by-nc-nd)
  • PubMed (publishedVersion)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion)
  • Utrecht University Repository (Utrecht University) (submittedVersion, other-oa)
Funders
  • H2020 European Research Council (No 638467, 638467)
  • Eidgenössische Technische Hochschule Zürich (ETH‐33‐14, ETH‐33 14‐1)
  • Natural Environment Research Council (NE/M003752/1)
  • Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung (200020_160046, 200021_143485, 200021_169849)
Topics
  • Physical Sciences › Earth and Planetary Sciences › Atmospheric Science › Geology and Paleoclimatology Research
  • Physical Sciences › Earth and Planetary Sciences › Paleontology › Paleontology and Stratigraphy of Fossils
  • Physical Sciences › Earth and Planetary Sciences › Geochemistry and Petrology › Geological and Geochemical Analysis
Keywords
carbonate clumped isotopes, clumped isotope thermometry, standardization, interlaboratory comparability, temperature calibration, uncertainty reduction, gas preparation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.