A histomorghometric study of screw‐shaped and removal torque titanium implants with three different surface topographies
The DOI matches its Crossref record.
Abstract
Screw‐shaped implants with 3 different surface topographies, evidenced visually as well as numerically with an optical profilometer. were inserted in rabbit bone. After a healing period of 12 weeks, a statistically significant higher removal torque was needed to unscrew screws blasted with25 μm TiO 2 particles and screws blasted with 75 μm particles of A1203 compared with screws with a turned surface. The histomorphometric evaluation demonstrated a higher percentage of bone‐to‐metal contact for implants blasted with 25 μm particles of TiO 2 compared with the as‐machined implants. A greater surface area of bone in threads was found for the turned screws compared with screws blasted with 25 μm TiO 2 particles. In the short‐term follow‐up, there was a better fixation of implants with an average surface roughness of 0.9–1.3 μm and with a homogeneous surface structure than of implants with an average surface roughness of 0.4 μm and with a clear direction of the surface pattern.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Surface treatments of titanium dental implants for rapid osseointegration
Le Guéhennec, L., Soueidan, A., Layrolle, P., & Amouriq, Y. (2007) · Dental Materials · doi:10.1016/j.dental.2006.06.025 · Cited by 2,406
Effects of titanium surface topography on bone integration: a systematic review
Wennerberg, A., & Albrektsson, T. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01775.x · Cited by 1,462
Self-citationEnhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Buser, D., Broggini, N., Wieland, M., Schenk, R. K., Denzer, A. J., Cochran, D. L., Hoffmann, B., Lussi, A., & Steinemann, S. G. (2004) · Journal of Dental Research · doi:10.1177/154405910408300704 · Cited by 1,202
Buser, D., Sennerby, L., & De Bruyn, H. (2017) · Periodontology 2000 · doi:10.1111/prd.12185 · Cited by 792
Engineering biocompatible implant surfaces
Bauer, S., Schmuki, P., von der Mark, K., & Park, J. (2013) · Progress in Materials Science · doi:10.1016/j.pmatsci.2012.09.001 · Cited by 780
Cochran, D. L., Schenk, R. K., Lussi, A., Higginbottom, F. L., & Buser, D. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199804)40:1<1::aid-jbm1>3.0.co;2-q · Cited by 690
De novo alveolar bone formation adjacent to endosseous implants: A model study in the dog
Berglundh, T., Abrahamsson, I., Lang, N. P., & Lindhe, J. (2003) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2003.00972.x · Cited by 689
Buser, D., Janner, S. F. M., Wittneben, J., Brägger, U., Ramseier, C. A., & Salvi, G. E. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2012.00456.x · Cited by 642
Bosshardt, D. D., Chappuis, V., & Buser, D. (2017) · Periodontology 2000 · doi:10.1111/prd.12179 · Cited by 574
Effects of implant surface coatings and composition on bone integration: a systematic review
Junker, R., Dimakis, A., Thoneick, M., & Jansen, J. A. (2009) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2009.01777.x · Cited by 535
Cochran, D. L., Hermann, J. S., Schenk, R. K., Higginbottom, F. L., & Buser, D. (1997) · Journal of Periodontology · doi:10.1902/jop.1997.68.2.186 · Cited by 504
Abrahamsson, I., Berglundh, T., Linder, E., Lang, N. P., & Lindhe, J. (2004) · Clinical Oral Implants Research · doi:10.1111/j.1600-0501.2004.01082.x · Cited by 450
Cooper, L. F., Zhou, Y., Takebe, J., Guo, J., Abron, A., Holmén, A., & Ellingsen, J. E. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.009 · Cited by 390
Surface topographical factors influencing bacterial attachment
Crawford, R. J., Webb, H. K., Truong, V. K., Hasan, J., & Ivanova, E. P. (2012) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2012.06.015 · Cited by 384
Organic–Inorganic Surface Modifications for Titanium Implant Surfaces
de Jonge, L. T., Leeuwenburgh, S. C. G., Wolke, J. G. C., & Jansen, J. A. (2008) · Pharmaceutical Research · doi:10.1007/s11095-008-9617-0 · Cited by 361
Wennerberg, A. (1996) · Biomaterials · doi:10.1016/0142-9612(96)80750-2 · Cited by 355
Self-citationA role for surface topography in creating and maintaining bone at titanium endosseous implants
Cooper, L. F. (2000) · The Journal of Prosthetic Dentistry · doi:10.1067/mpr.2000.111966 · Cited by 336
A Comparison of Endosseous Dental Implant Surfaces
Cochran, D. L. (1999) · Journal of Periodontology · doi:10.1902/jop.1999.70.12.1523 · Cited by 329
Schenk, R. K., & Buser, D. (1998) · Periodontology 2000 · doi:10.1111/j.1600-0757.1998.tb00120.x · Cited by 300
Surface treatments and roughness properties of Ti-based biomaterials
Bagno, A., & Di Bello, C. (2004) · Journal of Materials Science: Materials in Medicine · doi:10.1023/b:jmsm.0000042679.28493.7f · Cited by 282
Wennerberg, A., Albrektsson, T., & Lausmaa, J. (1996) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199602)30:2<251::aid-jbm16>3.0.co;2-p · Cited by 263
Self-citationMustafa, K., Wroblewski, J., Lopez, B. S., Wennerberg, A., Hultenby, K., & Arvidson, K. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.120513.x · Cited by 245
Self-citationMechanical aspects of dental implants and osseointegration: A narrative review
Li, J., Jansen, J. A., Walboomers, X. F., & van den Beucken, J. J. (2020) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2019.103574 · Cited by 232
Leung, S. (2008) · International Journal of Nanomedicine · doi:10.2147/ijn.s3234 · Cited by 231
“Consequently, metallic oxides such as TiO 2 , that is used in dental and other implants (Wennerberg et al 1995; Rasmusson et al 2005) because the material appears to be biologically compatible, may not be as benign as one previously presupposed.”
BackgroundFerguson, S. J., Broggini, N., Wieland, M., de Wild, M., Rupp, F., Geis‐Gerstorfer, J., Cochran, D. L., & Buser, D. (2006) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30678 · Cited by 202
Ivanoff, C., Widmark, G., Hallgren, C., Sennerby, L., & Wennerberg, A. (2001) · Clinical Oral Implants Research · doi:10.1034/j.1600-0501.2001.012002128.x · Cited by 195
Self-citation
Metadata
- Authors
- Wennerberg, A., Albrektsson, T., Andersson, B., & Krol, J. J.
- Venue
- Clinical Oral Implants Research
- Publisher
- Wiley
- Published
- 1995-03
- Volume
- 6
- Issue
- 1
- Pages
- 24-30
- ISSN
- 0905-7161 (ISSN-L)
- 1600-0501
- OpenAlex
- W2003539293
- Cited by
- 537
- References
- 0
- FWCI
- 21.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.