The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
MRI Estimation of Global Brain Oxygen Consumption Rate
Open accessAbstract
Measuring the global cerebral metabolic rate of oxygen ( CMRO 2 ) is a valuable tool for assessing brain vitality and function. Measurement of blood oxygen saturation ( HbO 2 ) and flow in the major cerebral outflow and inflow vessels can provide a global estimate of CMRO 2 . We demonstrate a rapid noninvasive method for quantifying CMRO 2 by simultaneously measuring venous oxygen saturation in the superior sagittal sinus with magnetic resonance susceptometry-based oximetry, a technique that exploits the intrinsic susceptibility of deoxygenated hemoglobin, and the average blood inflow rate with phase-contrast magnetic resonance imaging. The average venous HbO 2 , cerebral blood flow, and global CMRO 2 values in eight healthy, normal study subjects were 64%±4%, 45.2±3.2 mL per 100 g per minute, and 127±7 μmol per 100 g per minute, respectively. These values are in good agreement with those reported in literature. The technique described is noninvasive, robust, and reproducible for in vivo applications, making it ideal for use in clinical settings for assessing the pathologies associated with dysregulation of cerebral metabolism. In addition, the short acquisition time (∼30 seconds) makes the technique suitable for studying the temporal variations in CMRO 2 in response to physiologic challenges.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yushkevich, P. A., Piven, J., Hazlett, H. C., Smith, R. G., Ho, S., Gee, J. C., & Gerig, G. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.01.015 · Cited by 8,868
Effect of Ischemia on Known Substrates and Cofactors of the Glycolytic Pathway in Brain
Lowry, O. H., Passonneau, J. V., Hasselberger, F. X., & Schulz, D. W. (1964) · Journal of Biological Chemistry · doi:10.1016/s0021-9258(18)51740-3 · Cited by 2,221
Kety, S. S., & Schmidt, C. F. (1948) · Journal of Clinical Investigation · doi:10.1172/jci101995 · Cited by 1,827 · cited 1×
“The cerebral metabolic rate of oxygen can be estimated by combining venous and arterial oxygen saturation and CBF measurements using Fick’s principle (Kety and Schmidt, 1948), CMRO2 ¼ CaCBF SaO2 SvO2ð Þ ð1Þ where CMRO2 is the cerebral metabolic rate of oxygen consumption in mmol/minute per 100 g,…”
MethodSchenck, J. F. (1996) · Medical Physics · doi:10.1118/1.597854 · Cited by 1,522
Three‐dimensional magnetization‐prepared rapid gradient‐echo imaging (3D MP RAGE)
Mugler, J. P., & Brookeman, J. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910150117 · Cited by 1,265
Frackowiak, R. S. J., Lenzi, G.-L., Jones, T., & Heather, J. D. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198012000-00001 · Cited by 1,242
Thulborn, K. R., Waterton, J. C., Matthews, P. M., & Radda, G. K. (1982) · Biochimica et Biophysica Acta (BBA) - General Subjects · doi:10.1016/0304-4165(82)90333-6 · Cited by 1,134
Brain oxygen utilization measured with O-15 radiotracers and positron emission tomography.
Mintun, M. A., Raichle, M. E., Martin, W. R. W., & Herscovitch, P. (1984) · PubMed · Cited by 608
Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference Technique
Bryant, D. J., Payne, J. A., Firmin, D. N., & Longmore, D. B. (1984) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198408000-00002 · Cited by 545
Magnetic resonance angiography.
Dumoulin, C. L., & Hart, H. R. (1986) · Radiology · doi:10.1148/radiology.161.3.3786721 · Cited by 506
Spees, W. M., Yablonskiy, D. A., Oswood, M. C., & Ackerman, J. J. H. (2001) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1072 · Cited by 461
Powers, W. J., Grubb, R. L., Darriet, D., & Raichle, M. E. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.89 · Cited by 425
He, X., & Yablonskiy, D. A. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21108 · Cited by 396
Weisskoff, R. M., & Kiihne, S. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910240219 · Cited by 381
Quantitative evaluation of oxygenation in venous vessels using T2‐Relaxation‐Under‐Spin‐Tagging MRI
Lu, H., & Ge, Y. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21627 · Cited by 360
Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T
Wright, G. A., Hu, B. S., & Macovski, A. (1991) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880010303 · Cited by 327
Coles, J. P., Minhas, P. S., Fryer, T. D., Smielewski, P., Aigbirihio, F., Donovan, T., Downey, S. P. M. J., Williams, G., Chatfield, D., Matthews, J. C., et al. (2002) · Critical Care Medicine · doi:10.1097/00003246-200209000-00002 · Cited by 296
Quantitative magnetic resonance flow imaging.
Pelc, N. J., Sommer, F. G., Li, K. C., et al. (1994) · PubMed · Cited by 242
Haacke, E. M., Lai, S., Reichenbach, J. R., Kuppusamy, K., Hoogenraad, F. G. C., Takeichi, H., & Lin, W. (1997) · Human Brain Mapping · doi:10.1002/(sici)1097-0193(1997)5:5<341::aid-hbm2>3.0.co;2-3 · Cited by 224
Noninvasive quantification of whole‐brain cerebral metabolic rate of oxygen (CMRO2) by MRI
Xu, F., Ge, Y., & Lu, H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21994 · Cited by 208
Greene, A. E., Todorova, M. T., & Seyfried, T. N. (2003) · Journal of Neurochemistry · doi:10.1046/j.1471-4159.2003.01862.x · Cited by 168
Decreased medial temporal oxygen metabolism in Alzheimer's disease shown by PET.
Ishii, K., Kitagaki, H., Kono, M., & Mori, E. (1996) · PubMed · Cited by 159
MAGISTRETTI, P. J., & PELLERIN, L. (1996) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1996.tb34449.x · Cited by 159
MR susceptometry for measuring global brain oxygen extraction
Fernández‐Seara, M. A., Techawiboonwong, A., Detre, J. A., & Wehrli, F. W. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20892 · Cited by 147
Self-citationLeenders, K. L., Frackowiak, R. S. J., Quinn, N. P., & MARSDEN, C. D. (1986) · Movement Disorders · doi:10.1002/mds.870010110 · Cited by 144
Nagdyman, N., Fleck, T., Schubert, S., Ewert, P., Peters, B., Lange, P., & Abdul‐Khaliq, H. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2618-0 · Cited by 144
An, H., & Lin, W. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10576 · Cited by 138
Abduljalil, A., Schmalbrock, P., Novak, V., & Chakeres, D. W. (2003) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.10362 · Cited by 128
Ibaraki, M., Miura, S., Shimosegawa, E., Sugawara, S., Mizuta, T., Ishikawa, A., & Amano, M. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044008 · Cited by 115
Blood oxygen saturation assessment in vivo using T2 * estimation
Li, D., Wang, Y., & Waight, D. J. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910390503 · Cited by 98
Coplin, W. M., O’Keefe, G. E., Grady, M. S., Grant, G. A., March, K. S., Winn, H. R., & Lam, A. M. (1997) · Neurosurgery · doi:10.1097/00006123-199707000-00022 · Cited by 82
Ito, H., Ibaraki, M., Kanno, I., Fukuda, H., & Miura, S. (2005) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/sj.jcbfm.9600030 · Cited by 75
Kretschmann, H., Kammradt, G., Krauthausen, I., Sauer, B., & Wingert, F. (1986) · PubMed · Cited by 66
Langham, M. C., Magland, J. F., Floyd, T. F., & Wehrli, F. W. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21499 · Cited by 66
Self-citationLangham, M. C., Magland, J. F., Epstein, C. L., Floyd, T. F., & Wehrli, F. W. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21981 · Cited by 54
Self-citationCellular Mechanisms of Brain Energy Metabolism
GJEDDE, A. H., & Magistretti, P. J. (2011) · Elsevier eBooks · doi:10.1016/b978-1-4160-5316-3.00008-3 · Cited by 37
Chien, D., Levin, D. L., & Anderson, C. M. (1994) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910320419 · Cited by 35
Partial volume effects on vascular T2 measurements
Stainsby, J. A., & Wright, G. A. (1998) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910400322 · Cited by 35
Jugular Bulb Oximetry for the Monitoring of Cerebral Blood Flow and Metabolism
Mayberg, T. S., & Lam, A. M. (1996) · Neurosurgery Clinics of North America · doi:10.1016/s1042-3680(18)30361-9 · Cited by 25
Santens, P., Reuck, J. D., Crevits, L., et al. (2008) · European Neurology · doi:10.1159/000117398 · Cited by 17
Cited by
Twarda-Clapa, A., Olczak, A., Białkowska, A. M., & Koziołkiewicz, M. (2022) · Cells · doi:10.3390/cells11081312 · Cited by 746
Quantitative susceptibility mapping: current status and future directions
Haacke, E. M., Liu, S., Buch, S., Zheng, W., Wu, D., & Ye, Y. (2015) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2014.09.004 · Cited by 511
The physics of functional magnetic resonance imaging (fMRI)
Buxton, R. B. (2013) · Reports on Progress in Physics · doi:10.1088/0034-4885/76/9/096601 · Cited by 341
Label-free oxygen-metabolic photoacoustic microscopy in vivo
Yao, J., Maslov, K. I., Zhang, Y., Xia, Y., & Wang, L. V. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3594786 · Cited by 333
Brain Network Modularity Predicts Exercise-Related Executive Function Gains in Older Adults
Baniqued, P. L., Gallen, C. L., Voss, M. W., Burzynska, A. Z., Wong, C. N., Cooke, G. E., Duffy, K., Fanning, J., Ehlers, D. K., Salerno, E. A., et al. (2018) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2017.00426 · Cited by 112
Metadata
- Authors
- Jain, V., Langham, M. C., & Wehrli, F. W.
- Venue
- Journal of Cerebral Blood Flow & Metabolism
- Publisher
- SAGE Publications
- Published
- 2010-04-21
- Volume
- 30
- Issue
- 9
- Pages
- 1598-1607
- ISSN
- 0271-678X (ISSN-L)
- 1559-7016
- OpenAlex
- W2104035752
- Cited by
- 275
- References
- 40
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.