A role for microfluidic systems in precision medicine
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Precision oncology continues to challenge the “one-size-fits-all” dogma. Under the precision oncology banner, cancer patients are screened for molecular tumor alterations that predict treatment response, ideally leading to optimal treatments. Functional assays that directly evaluate treatment efficacy on the patient’s cells offer an alternative and complementary tool to improve the accuracy of precision oncology. Unfortunately, traditional Petri dish-based assays overlook much tumor complexity, limiting their potential as predictive functional biomarkers. Here, we review past applications of microfluidic systems for precision medicine and discuss the present and potential future role of functional microfluidic assays as treatment predictors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microenvironmental regulation of tumor progression and metastasis
Quail, D. F., & Joyce, J. A. (2013) · Nature Medicine · doi:10.1038/nm.3394 · Cited by 7,994
Understanding the tumor immune microenvironment (TIME) for effective therapy
Binnewies, M., Roberts, E. W., Kersten, K., Chan, V., Fearon, D. F., Merad, M., Coussens, L. M., Gabrilovich, D. I., Ostrand-Rosenberg, S., Hedrick, C. C., et al. (2018) · Nature Medicine · doi:10.1038/s41591-018-0014-x · Cited by 6,145
Detection of Circulating Tumor DNA in Early- and Late-Stage Human Malignancies
Bettegowda, C., Sausen, M., Leary, R. J., Kinde, I., Wang, Y., Agrawal, N., Bartlett, B. R., Wang, H., Luber, B., Alani, R. M., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3007094 · Cited by 5,067
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250
Bhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Self-citationLiquid biopsies come of age: Towards implementation of circulating tumour DNA
Wan, J. C. M., Massie, C., Garcia-Corbacho, J., Mouliere, F., Brenton, J. D., Caldas, C., Pacey, S., Baird, R., & Rosenfeld, N. (2017) · Nature Reviews Cancer · doi:10.1038/nrc.2017.7 · Cited by 2,809
Influence of tumour micro-environment heterogeneity on therapeutic response
Junttila, M. R., & de Sauvage, F. J. (2013) · Nature · doi:10.1038/nature12626 · Cited by 2,694
Vogel, C. L., Cobleigh, M. A., Tripathy, D., Gutheil, J. C., Harris, L. N., Fehrenbacher, L., Slamon, D. J., Murphy, M., Novotny, W. F., Burchmore, M., et al. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.20.3.719 · Cited by 1,860
Organs-on-chips at the frontiers of drug discovery
Esch, E. W., Bahinski, A., & Huh, D. (2015) · Nature Reviews Drug Discovery · doi:10.1038/nrd4539 · Cited by 1,185
Ashley, E. A. (2016) · Nature Reviews Genetics · doi:10.1038/nrg.2016.86 · Cited by 1,116 · cited 1×
“Microfluidic models in the clinic Microfluidic devices designed for the clinic broadly fall into two different applications: (1) analyte detection for molecular diagnostics, and (2) disease modeling for functional diagnostics.”
MethodModelling cancer in microfluidic human organs-on-chips
Sontheimer-Phelps, A., Hassell, B. A., & Ingber, D. E. (2019) · Nature Reviews Cancer · doi:10.1038/s41568-018-0104-6 · Cited by 906
Metabolic Interactions in the Tumor Microenvironment
Lyssiotis, C. A., & Kimmelman, A. C. (2017) · Trends in Cell Biology · doi:10.1016/j.tcb.2017.06.003 · Cited by 853
Yi, H.-G., Jeong, Y. H., Kim, Y., Choi, Y.-J., Moon, H. E., Park, S. H., Kang, K. S., Bae, M., Jang, J., Youn, H., et al. (2019) · Nature Biomedical Engineering · doi:10.1038/s41551-019-0363-x · Cited by 634
Eiber, M., Herrmann, K., Calais, J., Hadaschik, B., Giesel, F. L., Hartenbach, M., Hope, T., Reiter, R., Maurer, T., Weber, W. A., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.198119 · Cited by 626
Precision medicine for cancer with next-generation functional diagnostics
Friedman, A. A., Letai, A., Fisher, D. E., & Flaherty, K. T. (2015) · Nature Reviews Cancer · doi:10.1038/nrc4015 · Cited by 570
Large-Scale Delineation of Secreted Protein Biomarkers Overexpressed in Cancer Tissue and Serum
Welsh, J. B., Sapinoso, L. M., Kern, S. G., Brown, D. A., Liu, T., Bauskin, A. R., Ward, R. L., Hawkins, N. J., Quinn, D. I., Russell, P. J., et al. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0530278100 · Cited by 503
A history of exploring cancer in context
Maman, S., & Witz, I. P. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0006-7 · Cited by 502
Hassell, B. A., Goyal, G., Lee, E., Sontheimer-Phelps, A., Levy, O., Chen, C. S., & Ingber, D. E. (2017) · Cell Reports · doi:10.1016/j.celrep.2017.09.043 · Cited by 467
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Chen, M. B., Whisler, J. A., Fröse, J., Yu, C., Shin, Y., & Kamm, R. D. (2017) · Nature Protocols · doi:10.1038/nprot.2017.018 · Cited by 385
Xu, Z., Gao, Y., Hao, Y., Li, E., Wang, Y., Zhang, J., Wang, W., Gao, Z., & Wang, Q. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.02.045 · Cited by 295
Personalised organs-on-chips: functional testing for precision medicine
van den Berg, A., Mummery, C. L., Passier, R., & van der Meer, A. D. (2019) · Lab on a Chip · doi:10.1039/c8lc00827b · Cited by 270
3D microfluidic ex vivo culture of organotypic tumor spheroids to model immune checkpoint blockade
Aref, A. R., Campisi, M., Ivanova, E., Portell, A., Larios, D., Piel, B. P., Mathur, N., Zhou, C., Coakley, R. V., Bartels, A., et al. (2018) · Lab on a Chip · doi:10.1039/c8lc00322j · Cited by 265
Current Progresses of Exosomes as Cancer Diagnostic and Prognostic Biomarkers
Huang, T., & Deng, C.-X. (2019) · International Journal of Biological Sciences · doi:10.7150/ijbs.27796 · Cited by 228
Kim, S., Chung, M., Ahn, J., Lee, S., & Jeon, N. L. (2016) · Lab on a Chip · doi:10.1039/c6lc00910g · Cited by 227
Microfluidics: A New Tool for Modeling Cancer–Immune Interactions
Boussommier-Calleja, A., Li, R., Chen, M. B., Wong, S. C., & Kamm, R. D. (2016) · Trends in Cancer · doi:10.1016/j.trecan.2015.12.003 · Cited by 224
Organ-on-chip models of cancer metastasis for future personalized medicine: From chip to the patient
Caballero, D., Kaushik, S., Correlo, V. M., Oliveira, J. M., Reis, R. L., & Kundu, S. C. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.10.005 · Cited by 221
Trujillo-de Santiago, G., Flores-Garza, B. G., Tavares-Negrete, J. A., Lara-Mayorga, I. M., González-Gamboa, I., Zhang, Y. S., Rojas-Martínez, A., Ortiz-López, R., & Álvarez, M. M. (2019) · Materials · doi:10.3390/ma12182945 · Cited by 184
Truong, D. D., Kratz, A., Park, J. G., Barrientos, E. S., Saini, H., Nguyen, T., Pockaj, B., Mouneimne, G., LaBaer, J., & Nikkhah, M. (2019) · Cancer Research · doi:10.1158/0008-5472.can-18-2293 · Cited by 149
Complex Tissue and Disease Modeling using hiPSCs
Passier, R., Orlova, V., & Mummery, C. (2016) · Cell Stem Cell · doi:10.1016/j.stem.2016.02.011 · Cited by 142
Evaluating natural killer cell cytotoxicity against solid tumors using a microfluidic model
Ayuso, J. M., Truttschel, R., Gong, M. M., Humayun, M., Virumbrales-Munoz, M., Vitek, R., Felder, M., Gillies, S. D., Sondel, P., Wisinski, K. B., et al. (2019) · OncoImmunology · doi:10.1080/2162402x.2018.1553477 · Cited by 142
Self-citationA 3D human renal cell carcinoma-on-a-chip for the study of tumor angiogenesis
Miller, C. P., Tsuchida, C., Zheng, Y., Himmelfarb, J., & Akilesh, S. (2018) · Neoplasia · doi:10.1016/j.neo.2018.02.011 · Cited by 105
Lugo-Cintrón, K. M., Gong, M. M., Ayuso, J. M., Tomko, L. A., Beebe, D. J., Virumbrales-Muñoz, M., & Ponik, S. M. (2020) · Cancers · doi:10.3390/cancers12051173 · Cited by 103
Self-citationGong, M. M., Lugo-Cintron, K. M., White, B. R., Kerr, S. C., Harari, P. M., & Beebe, D. J. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119225 · Cited by 87
Self-citationA microfluidic platform for functional testing of cancer drugs on intact tumor slices
Rodriguez, A. D., Horowitz, L. F., Castro, K., Kenerson, H., Bhattacharjee, N., Gandhe, G., Raman, A., Monnat, R. J., Yeung, R., Rostomily, R. C., et al. (2020) · Lab on a Chip · doi:10.1039/c9lc00811j · Cited by 77
Disease-on-a-chip: mimicry of tumor growth in mammary ducts
Vidi, P.-A., Maleki, T., Ochoa, M., Wang, L., Clark, S. M., Leary, J. F., & Lelièvre, S. A. (2014) · Lab Chip · doi:10.1039/c3lc50819f · Cited by 71
Jiménez-Torres, J. A., Virumbrales-Muñoz, M., Sung, K. E., Lee, M. H., Abel, E. J., & Beebe, D. J. (2019) · EBioMedicine · doi:10.1016/j.ebiom.2019.03.026 · Cited by 46
Self-citationToward improved in vitro models of human cancer
Ayuso, J. M., Park, K.-Y., Virumbrales-Muñoz, M., & Beebe, D. J. (2021) · APL Bioengineering · doi:10.1063/5.0026857 · Cited by 40
Self-citationVirumbrales-Muñoz, M., Chen, J., Ayuso, J., Lee, M., Abel, E. J., & Beebe, D. J. (2020) · Lab on a Chip · doi:10.1039/d0lc00252f · Cited by 39
Self-citationWang, Z., Liu, Z., Li, L., & Liang, Q. (2015) · Microfluidics and Nanofluidics · doi:10.1007/s10404-015-1637-6 · Cited by 28
Metadata
- Authors
- Ayuso, J. M., Virumbrales-Muñoz, M., Lang, J. M., & Beebe, D. J.
- Venue
- Nature Communications
- Published
- 2022-06-02
- Volume
- 13
- Issue
- 1
- Pages
- 3086-3086
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4281742577
- Cited by
- 216
- References
- 41
- FWCI
- 11.54
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.