Interindividual- and blood-correlated sweat phenylalanine multimodal analytical biochips for tracking exercise metabolism
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
In situ monitoring of endogenous amino acid loss through sweat can provide physiological insights into health and metabolism. However, existing amino acid biosensors are unable to quantitatively assess metabolic status during exercise and are rarely used to establish blood-sweat correlations because they only detect a single concentration indicator and disregard sweat rate. Here, we present a wearable multimodal biochip integrated with advanced electrochemical electrodes and multipurpose microfluidic channels that enables simultaneous quantification of multiple sweat indicators, including phenylalanine and chloride, as well as sweat rate. This combined measurement approach reveals a negative correlation between sweat phenylalanine levels and sweat rates among individuals, which further enables identification of individuals at high metabolic risk. By tracking phenylalanine fluctuations induced by protein intake during exercise and normalizing the concentration indicator by sweat rates to reduce interindividual variability, we demonstrate a reliable method to correlate and analyze sweat-blood phenylalanine levels for personal health monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amino acids: Metabolism, functions, and nutrition
Wu, G. (2009) · Amino Acids · doi:10.1007/s00726-009-0269-0 · Cited by 3,004
Amino acids and immune function
Li, P., Yin, Y.-L., Li, D., Woo Kim, S., & Wu, G. (2007) · British Journal of Nutrition · doi:10.1017/s000711450769936x · Cited by 1,584 · cited 2×
“The authors af fi rm that human research participants provided informed consent forthepublication of the images in Fig.4a, b, as well as the movies in Supplementary Videos 3, 4.”
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Technology Roadmap for Flexible Sensors
Luo, Y., Abidian, M. R., Ahn, J.-H., Akinwande, D., Andrews, A. M., Antonietti, M., Bao, Z., Berggren, M., Berkey, C. A., Bettinger, C. J., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c12606 · Cited by 1,383
A laser-engraved wearable sensor for sensitive detection of uric acid and tyrosine in sweat
Yang, Y., Song, Y., Bo, X., Min, J., Pak, O. S., Zhu, L., Wang, M., Tu, J., Kogan, A., Zhang, H., et al. (2020) · Nature Biotechnology · doi:10.1038/s41587-019-0321-x · Cited by 1,270 · cited 3×
“Moreover, the use of other commonly measured sweat biomarkers and their analysis in combination with sweat rate measurements for health monitoring have also been lacking 24,36,48 – 54 .”
Self-citationBrain Serotonin Content: Physiological Regulation by Plasma Neutral Amino Acids
Fernstrom, J. D., & Wurtman, R. J. (1972) · Science · doi:10.1126/science.178.4059.414 · Cited by 1,160 · cited 1×
“…fl uidicstoensure the reliability of the Phe measurement in the next period without the need of a new sensor; 5) After the second cycling exercise, the subjects are asked to sit and rest for 40min allowing the body to regulate the elevationof AAslevelscaused…”
A wearable electrochemical biosensor for the monitoring of metabolites and nutrients
Wang, M., Yang, Y., Min, J., Song, Y., Tu, J., Mukasa, D., Ye, C., Xu, C., Heflin, N., McCune, J. S., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00916-z · Cited by 896 · cited 21×
“Their foreheads were cleaned with alcohol swabs removing skin contaminants (not limited toAAs)beforethesensorswere attachedtothebody.”
InfluentialSelf-citationVolpi, E., Kobayashi, H., Sheffield-Moore, M., Mittendorfer, B., & Wolfe, R. R. (2003) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/78.2.250 · Cited by 846 · cited 1×
“Fluctuations in Phe concentrations are also linked to muscle protein metabolism during exercise 33 , liver dysfunction in obesity 34 , and viral infection severity 11 .”
Felig, P. (1975) · Annual Review of Biochemistry · doi:10.1146/annurev.bi.44.070175.004441 · Cited by 789 · cited 1×
“4 – 8).”
Branched Chain Amino Acids: Beyond Nutrition Metabolism
Nie, C., He, T., Zhang, W., Zhang, G., & Ma, X. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19040954 · Cited by 786 · cited 2×
“4 – 8).”
Physiology of sweat gland function: The roles of sweating and sweat composition in human health
Baker, L. B. (2019) · Temperature · doi:10.1080/23328940.2019.1632145 · Cited by 732 · cited 2×
“14, 15).”
Sonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Molecularly Imprinted Polymers in Electrochemical and Optical Sensors
Ahmad, O. S., Bedwell, T. S., Esen, C., Garcia-Cruz, A., & Piletsky, S. A. (2019) · Trends in Biotechnology · doi:10.1016/j.tibtech.2018.08.009 · Cited by 602 · cited 1×
“By contrast, electrochemical sensors that do not depend on bio-af fi nity interactions are widely considered more suitable to ful fi ll the design requirements of wearable devices, especially considering their low cost and ease of fabrication 42 .”
Investigation of Cortisol Dynamics in Human Sweat Using a Graphene-Based Wireless mHealth System
Torrente-Rodríguez, R. M., Tu, J., Yang, Y., Min, J., Wang, M., Song, Y., Yu, Y., Xu, C., Ye, C., IsHak, W. W., et al. (2020) · Matter · doi:10.1016/j.matt.2020.01.021 · Cited by 479
A Wearable Microfluidic Sensing Patch for Dynamic Sweat Secretion Analysis
Nyein, H. Y. Y., Tai, L.-C., Ngo, Q. P., Chao, M., Zhang, G. B., Gao, W., Bariya, M., Bullock, J., Kim, H., Fahad, H. M., et al. (2018) · ACS Sensors · doi:10.1021/acssensors.7b00961 · Cited by 446
Stretchable graphene–hydrogel interfaces for wearable and implantable bioelectronics
Lu, Y., Yang, G., Wang, S., Zhang, Y., Jian, Y., He, L., Yu, T., Luo, H., Kong, D., Xianyu, Y., et al. (2023) · Nature Electronics · doi:10.1038/s41928-023-01091-y · Cited by 442 · cited 1×
“In brief, the differential re fl ectivity/transmittance to visible light at μ -dots leads to an apparent visual color change of the serpentine out fl ow channel (one meander corresponding to 1 μ L, volume resolution of 0.5 μ L) in empty and water-fi lled states 55,56 (Fig.”
InfluentialKey European guidelines for the diagnosis and management of patients with phenylketonuria
van Spronsen, F. J., van Wegberg, A. M., Ahring, K., Bélanger-Quintana, A., Blau, N., Bosch, A. M., Burlina, A., Campistol, J., Feillet, F., Giżewska, M., et al. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30320-5 · Cited by 425
Understanding nutrition, depression and mental illnesses
Sathyanarayana Rao, T., Asha, M., Ramesh, B., & Jagannatha Rao, K. (2008) · Indian Journal of Psychiatry · doi:10.4103/0019-5545.42391 · Cited by 408
A wireless patch for the monitoring of C-reactive protein in sweat
Tu, J., Min, J., Song, Y., Xu, C., Li, J., Moore, J., Hanson, J., Hu, E., Parimon, T., Wang, T.-Y., et al. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-023-01059-5 · Cited by 395
Nyein, H. Y. Y., Bariya, M., Kivimäki, L., Uusitalo, S., Liaw, T. S., Jansson, E., Ahn, C. H., Hangasky, J. A., Zhao, J., Lin, Y., et al. (2019) · Science Advances · doi:10.1126/sciadv.aaw9906 · Cited by 388
Physiological mechanisms determining eccrine sweat composition
Baker, L. B., & Wolfe, A. S. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04323-7 · Cited by 367 · cited 2×
“Phenylalanine (Phe), an essential AA, is present insweatbuthasonlyalowpresenceontheskinsurface(non-NMF)and ishypothesizedtopartitionintosweatviadiffusionduetoitssmallsize and nonpolar side chain properties 14,29 .”
Cynober, L. A. (2002) · Nutrition · doi:10.1016/s0899-9007(02)00780-3 · Cited by 303
Non‐invasive Analyte Access and Sensing through Eccrine Sweat: Challenges and Outlook circa 2016
Heikenfeld, J. (2016) · Electroanalysis · doi:10.1002/elan.201600018 · Cited by 294 · cited 2×
“Phenylalanine (Phe), an essential AA, is present insweatbuthasonlyalowpresenceontheskinsurface(non-NMF)and ishypothesizedtopartitionintosweatviadiffusionduetoitssmallsize and nonpolar side chain properties 14,29 .”
Muscle amino acid metabolism at rest and during exercise: role in human physiology and metabolism.
Wagenmakers, A. J. M. (1998) · PubMed · Cited by 225
Sempionatto, J. R., Moon, J.-M., & Wang, J. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00139 · Cited by 208
Sweat as a diagnostic biofluid
Yang, D. S., Ghaffari, R., & Rogers, J. A. (2023) · Science · doi:10.1126/science.abq5916 · Cited by 200
11 Muscle Amino Acid Metabolism at Rest and During Exercise: Role in Human Physiology and Metabolism
WAGENMAKERS, A. J. M. (1998) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-199800260-00013 · Cited by 168
Zhong, B., Jiang, K., Wang, L., & Shen, G. (2022) · Advanced Science · doi:10.1002/advs.202103257 · Cited by 164 · cited 1×
“1f), indicating that the mechanism of Phe partitioningintosweatreliesondiffusionanditsconcentrationmaybe affected by sweat dilution 47 .”
Self-citationSemisynthetic sensor proteins enable metabolic assays at the point of care
Yu, Q., Xue, L., Hiblot, J., Griss, R., Fabritz, S., Roux, C., Binz, P.-A., Haas, D., Okun, J. G., & Johnsson, K. (2018) · Science · doi:10.1126/science.aat7992 · Cited by 161 · cited 1×
“Recent efforts in the portable detection of blood or urine Phe concentrations mainly rely on molecular recognition elements (e.g., antibodiesandaptamers),whicharefacedwithchallengessuchashigh cost, low stability, extensive washing requirements, and potential bioreactivity 38 – 41 .”
Bi, Y., Sun, M., Wang, J., Zhu, Z., Bai, J., Emran, M. Y., Kotb, A., Bo, X., & Zhou, M. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.3c00361 · Cited by 154
Amino Acid Sensing in Metabolic Homeostasis and Health
Hu, X., & Guo, F. (2020) · Endocrine Reviews · doi:10.1210/endrev/bnaa026 · Cited by 150 · cited 1×
“This differencebetweenMIPandNIPwasalsocharacterizedin[Fe(CN) 6 ] 3 − /4 − solution by cyclic voltammograms (CV) and electrochemical impedance spectroscopy (EIS) (Fig.”
Liu, Y., Li, X., Yang, H., Zhang, P., Wang, P., Sun, Y. H., Yang, F., Liu, W., Li, Y., Tian, Y., et al. (2023) · ACS Nano · doi:10.1021/acsnano.2c11267 · Cited by 149 · cited 1×
“This trend stems from thermoregulation, adaption, and equilibration of the body ’ s response to the exercise load as expected 57,58 .”
Zhao, J., Nyein, H. Y. Y., Hou, L., Lin, Y., Bariya, M., Ahn, C. H., Ji, W., Fan, Z., & Javey, A. (2021) · Advanced Materials · doi:10.1002/adma.202006444 · Cited by 144
Reeder, J. T., Xue, Y., Franklin, D., Deng, Y., Choi, J., Prado, O., Kim, R., Liu, C. Y., Hanson, J., Ciraldo, J. P., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-13431-8 · Cited by 129
Sun, M., Gu, Y., Pei, X., Wang, J., Liu, J., Ma, C., Bai, J., & Zhou, M. (2021) · Nano Energy · doi:10.1016/j.nanoen.2021.106061 · Cited by 113
Phenylalanine Monitoring via Aptamer-Field-Effect Transistor Sensors
Cheung, K. M., Yang, K.-A., Nakatsuka, N., Zhao, C., Ye, M., Jung, M. E., Yang, H., Weiss, P. S., Stojanović, M. N., & Andrews, A. M. (2019) · ACS Sensors · doi:10.1021/acssensors.9b01963 · Cited by 97
Wearable wristband-based electrochemical sensor for the detection of phenylalanine in biofluids
Parrilla, M., Vanhooydonck, A., Watts, R., & Wael, K. D. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113764 · Cited by 89
The serum amino acid profile in COVID-19
Atila, A., Alay, H., Yaman, M. E., Akman, T. Ç., Çadırcı, E., Bayrak, B., Çelìk, S., Atila, N. E., YAĞANOĞLU, A. M., Kadıoğlu, Y., et al. (2021) · Amino Acids · doi:10.1007/s00726-021-03081-w · Cited by 89
Pei, X., Sun, M., Wang, J., Bai, J., Bo, X., & Zhou, M. (2022) · Small · doi:10.1002/smll.202205061 · Cited by 84
Mukasa, D., Wang, M., Min, J., Yang, Y., Solomon, S. A., Han, H., Ye, C., & Gao, W. F. (2023) · Advanced Materials · doi:10.1002/adma.202212161 · Cited by 76
Gitlitz, P. H., Sunderman, & Hohnadel, D. C. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.10.1305 · Cited by 62 · cited 3×
“These physicochemical characteristics suggest that Phe would be useful as a sweat biomarker, especially since its sweat concentration could likely be correlated with blood Phe levels 30,31 .”
Zhang, X., Xia, Y., Liu, Y., Mugo, S. M., & Zhang, Q. M. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03884 · Cited by 51
Dunstan, R. H., Sparkes, D. L., Macdonald, M. M., de Jonge, X. J., Dascombe, B. J., Gottfries, J., Gottfries, C. G., & Roberts, T. K. (2017) · Nutrition Journal · doi:10.1186/s12937-017-0240-y · Cited by 50 · cited 1×
“In this regard, tracking exercise metabolism and assessing risk by monitoring sweat AA losses can avoid a net negative nitrogen balance due to depletion of free AAs resources, which leads to fatigue and pain during exercise 20,35 .”
Extraction and quantification of amino acids in human stratum corneum in vivo
Sylvestre, J., Bouissou, C., Guy, R. H., & Delgado-Charro, M. B. (2010) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2010.09805.x · Cited by 48
Świerczyński, J., Śledziński, T., Slominska, E. M., Smolenski, R. T., & Śledziński, Z. (2008) · Obesity Surgery · doi:10.1007/s11695-008-9521-z · Cited by 46 · cited 1×
“Fluctuations in Phe concentrations are also linked to muscle protein metabolism during exercise 33 , liver dysfunction in obesity 34 , and viral infection severity 11 .”
Sweat Facilitated Amino Acid Losses in Male Athletes during Exercise at 32-34°C
Dunstan, R. H., Sparkes, D. L., Dascombe, B. J., Macdonald, M. M., Evans, C. A., Stevens, C. J., Crompton, M. J., Gottfries, J., Franks, J., Murphy, G., et al. (2016) · PLOS ONE · doi:10.1371/journal.pone.0167844 · Cited by 43
The impact of obesity on physiological responses during prolonged exercise
Eijsvogels, T. M. H., Veltmeijer, M. T. W., Schreuder, T. H. A., Poelkens, F., Thijssen, D. H. J., & Hopman, M. T. E. (2011) · International Journal of Obesity · doi:10.1038/ijo.2010.277 · Cited by 42 · cited 1×
“This difference supports that overweight people tend to have lower levels of sweat Phe than lean people due to the concentration dilution effect caused by excessive sweat volume/rate 59 .”
Souza, S. L., Graça, G., & Oliva, A. (2018) · Skin Research and Technology · doi:10.1111/srt.12412 · Cited by 34 · cited 1×
“There are still many AAs in sweat that remain to be explored and studied by wearable biosensors and hence applied to health practical scenarios according to their uncovered, potential blood correlations 27,28 .”
Amino Acids in Human Blood Plasma after Single Meals of Meat, Oil, Sucrose and Whiskey
Nasset, E. S., Heald, F. P., Calloway, D. H., Margen, S., & Schneeman, P. (1979) · Journal of Nutrition · doi:10.1093/jn/109.4.621 · Cited by 32
Murphy, G. R., Dunstan, R. H., Macdonald, M. M., Borges, N. R., Radford, Z., Sparkes, D. L., Dascombe, B. J., & Roberts, T. K. (2019) · PLoS ONE · doi:10.1371/journal.pone.0223381 · Cited by 29
Jankovskaja, S., Morin, M., Gustafsson, A., Anderson, C. D., Lehoczki, B., Engblom, J., Björklund, S., Rezeli, M., Marko‐Varga, G., & Ruzgas, T. A. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c05470 · Cited by 25 · cited 1×
“21, 22), which enables visualized fl ow readouts for estimating sweat rate/ volume on the skin.”
Metabolomic stability of exercise-induced sweat
Harshman, S. W., Pitsch, R. L., Schaeublin, N. M., Smith, Z. K., Strayer, K. E., Phelps, M. S., Qualley, A. V., Cowan, D. W., Rose, S. D., O'Connor, M. L., et al. (2019) · Journal of Chromatography B · doi:10.1016/j.jchromb.2019.121763 · Cited by 19 · cited 1×
“There are still many AAs in sweat that remain to be explored and studied by wearable biosensors and hence applied to health practical scenarios according to their uncovered, potential blood correlations 27,28 .”
Longo, N., Li, S. K., Yan, G., et al. (2007) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-007-0675-y · Cited by 13 · cited 2×
“These physicochemical characteristics suggest that Phe would be useful as a sweat biomarker, especially since its sweat concentration could likely be correlated with blood Phe levels 30,31 .”
The Impact of Nutritional Supplementation on Sweat Metabolomic Content: A Proof-of-Concept Study
Harshman, S. W., Browder, A. B., Davidson, C. N., Pitsch, R. L., Strayer, K. E., Schaeublin, N. M., Phelps, M. S., O’Connor, M. L., Mackowski, N. S., Barrett, K. N., et al. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.659583 · Cited by 7
Cited by
Diving into Sweat: Advances, Challenges, and Future Directions in Wearable Sweat Sensing
Childs, A., Mayol, B., Lasalde-Ramírez, J. A., Song, Y., Sempionatto, J. R., & Gao, W. (2024) · ACS Nano · doi:10.1021/acsnano.4c10344 · Cited by 217
Metadata
- Authors
- Zhong, B., Qin, X., Xu, H., Liu, L., Li, L., Li, Z., Cao, L., Lou, Z., Jackman, J. A., Cho, N.-J., & Wang, L.
- Venue
- Nature Communications
- Published
- 2024-01-20
- Volume
- 15
- Issue
- 1
- Pages
- 624-624
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4391051391
- Cited by
- 176
- References
- 54
- FWCI
- 18.15
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.