CoChat

A flexible ECG patch compatible with NFC RF communication

Zulqarnain, Mohammad, Stanzione, Stefano, Rathinavel, Ganesh, Smout, Steve, Willegems, Myriam, Myny, Kris, Cantatore, Eugenio · 2020 · npj Flexible Electronics
Cited by 137

The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.

Abstract

With the advent of the internet of things, flexible wearable devices are gaining significant research interest, as they are unobtrusive, comfortable to wear and can support continuous observation of physiological signals, helping to monitor wellness or diagnose diseases. Amorphous Indium Gallium Zinc Oxide (a-IGZO) Thin Film Transistors (TFTs) fabricated on flexible substrates are an attractive option to build such bio-signal monitoring systems due to their flexibility, conformability to the human body, and low cost. This paper presents a flexible electrocardiogram (ECG) patch implemented on foil with self-aligned IGZO TFTs, which is capable to acquire the ECG signals, amplify them and convert them to a sequence of bits. The analogue frontend has a measured input-referred noise of 8 μV rms in the 1–100 Hz band. The system achieves experimentally 67.4 dB CMRR, 58.9 dB PSRR, and 16.5 MΩ input impedance at 50 Hz while using 1 kHz chopping. The signal from the electrodes is transformed to a 105.9-kb/s Manchester-encoded serial bit stream which could be sent wirelessly to a smart phone via Near Field Communication (NFC) for further elaboration. Power consumption is 15.4 mW for the digital and 280 μW for the analogue part. This contribution shows the fundamental steps to demonstrate intelligent plasters for biomedical applications based on flexible electronics providing an NFC-compatible digital output bit stream.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1038/s41528-020-0077-x

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 35

  1. Park, S. & Jayaraman, S. Enhancing the quality of life through wearable technology. IEEE Eng. Med. Biol. Mag. 22, 41–48 (2003). · DOI · Paper page
  2. Helleputte, N. V. et al. A multi-parameter signal-acquisition SoC for connected personal health applications. In Proc. 2014 IEEE International Solid-State Circuits Conference Digest of Technical Papers. 314–315 (2014).
  3. Khan, Y. et al. Flexible hybrid electronics: direct interfacing of soft and hard electronics for wearable health monitoring. Adv. Funct. Mater. 26, 8764–8775 (2016). · DOI · Paper page
  4. Costa, J. C. et al. Flexible sensors—from materials to applications. Technologies 7, 35 (2019). · DOI · Paper page
  5. Carey, P. G., Smith, P. M., Theiss, S. D. & Wickboldt, P. Polysilicon thin film transistors fabricated on low temperature plastic substrates. J. Vac. Sci. Technol. A 17, 1946–1949 (2000). · doi:10.1116/1.581708
  6. Yang, C.-S., Smith, L. L., Arthur, C. B. & Parsons, G. N. Stability of low-temperature amorphous silicon thin film transistors formed on glass and transparent plastic substrates. J. Vac. Sci. Technol. B 18, 683–689 (2000). · DOI · Paper page
  7. Dimitrakopoulos, C. D. & Mascaro, D. J. Organic thin-film transistors: a review of recent advances. IBM J. Res. Dev. 45, 11–27 (2001). · DOI · Paper page
  8. Dimitrakopoulos, C. D. & Malenfant, P. R. L. Organic thin film transistors for large area electronics. Adv. Mater. 14, 99–117 (2002). · DOI · Paper page
  9. Yu, X., Marks, T. J. & Facchetti, A. Metal oxides for optoelectronic applications. Nat. Mater. 15, 383–396 (2016). · DOI · Paper page
  10. Nomura, K. et al. Room-temperature fabrication of transparent flexible thin-film transistors using amorphous oxide semiconductors. Nature 432, 488–492 (2004). · DOI · Paper page
  11. Barquinha, P., Pereira, L., Goncalves, G., Martins, R. & Fortunato, E. Toward high-performance amorphous GIZO TFTs. J. Electrochem. Soc. 156, H161–H168 (2009). · doi:10.1149/1.3049819
  12. Kim, Y. H. et al. Flexible metal-oxide devices made by room-temperature photochemical activation of sol-gel films. Nature 489, 128–132 (2012). · DOI · Paper page
  13. Kim, Y. G. Facile fabrication of wire-type indium gallium zinc oxide thin-film transistors applicable to ultrasensitive flexible sensors. Sci. Rep. 8, 5546 (2018).
  14. Li, Y. et al. A stretchable-hybrid low-power monolithic ECG patch with microfluidic liquid-metal interconnects and stretchable carbon-black nanocomposite electrodes for wearable heart monitoring. Adv. Electron. Mater. 5, 1800463 (2018). · DOI · Paper page
  15. Lee, S. P. et al. Highly flexible, wearable, and disposable cardiac biosensors for remote and ambulatory monitoring. npj Dig. Med. 1, 2 (2018). · DOI · Paper page
  16. Xie, K. Portable wireless electrocorticography system with a flexible microelectrodes array for epilepsy treatment. Sci. Rep. 7, 7808 (2017).
  17. Son, D. et al. An integrated self-healable electronic skin system fabricated via dynamic reconstruction of a nanostructured conducting network. Nat. Nanotechnol. 13, 1057–1065 (2018). · DOI · Paper page
  18. Debener, S., Emkes, R., Vos, M.-D. & Bleichner, M. Unobtrusive ambulatory EEG using a smartphone and flexible printed electrodes around the ear. Sci. Rep. 5, 16743 (2015). · DOI · Paper page
  19. Lochner, C. M., Khan, Y., Pierre, A. & Arias, A. C. All-organic optoelectronic sensor for pulse oximetry. Nat. Commun. 5, 5745 (2014). · DOI · Paper page
  20. Sekitani, T. et al. Ultraflexible organic amplifier with biocompatible gel electrodes. Nat. Commun. 7, 11425 (2016). · DOI · Paper page
  21. Koo, J. H. et al. Wearable electrocardiogram monitor using carbon nanotube electronics and color-tunable organic light-emitting diodes. ACS Nano 11, 10032–10041 (2017). · DOI · Paper page
  22. Khodagholy, D. et al. In vivo recordings of brain activity using organic transistors. Nat. Commun. 4, 1575 (2013).
  23. Wang, X., Gu, Y., Xiong, Z., Cui, Z. & Zhang, T. Silk-molded flexible, ultrasensitive, and highly stable electronic skin for monitoring human physiological signals. Adv. Mater. 26, 1336–1342 (2013). · DOI · Paper page
  24. Wang, S. et al. Skin electronics from scalable fabrication of an intrinsically stretchable transistor array. Nature 555, 83–88 (2018). · DOI · Paper page
  25. Yeo, W. H. et al. Multifunctional epidermal electronics printed directly onto the skin. Adv. Mater. 25, 2773–2778 (2013). · DOI · Paper page
  26. Webster, J. Medical Instrumentation: Application and Design (John Wiley & Sons, Hoboken, NJ, USA, 2010).
  27. Myny, K. et al. A flexible ISO14443-a compliant 7.5 mW 128b metal-oxide NFC barcode tag with direct clock division circuit from 13.56 MHz carrier. In Proc. 2017 IEEE International Solid-State Circuits Conference. 258–259 (2017). · doi:10.1109/isscc.2017.7870359
  28. Neuman, M. R. The Biomedical Engineering Handbook: Medical Devices and Systems (CRC Press, Boca Raton, FL, USA, 2006).
  29. Moy, T. et al. An EEG acquisition and biomarker-extraction system using low-noise-amplifier and compressive-sensing circuits based on flexible, thin-film electronics. IEEE J. Solid-State Circuits 52, 309–321 (2017). · DOI
  30. Fuketa, H. et al. 1 μm-thickness ultra-flexible and high electrode-density surface electromyogram measurement sheet with 2 V organic transistors for prosthetic hand control. IEEE Trans. Biomed. Circuits Syst. 8, 824–833 (2014). · DOI
  31. Garripoli, C. et al. A fully integrated 11.2 mm² a-IGZO EMG front-end circuit on flexible substrate achieving up to 41dB SNR and 29MΩ input impedance. IEEE Solid-State Circuits Lett. 1, 142–145 (2018). · DOI
  32. Zulqarnain, M. et al. A 52 μW heart-rate measurement interface fabricated on a flexible foil with a-IGZO TFTs. In Proc. IEEE 44th European Solid State Circuits Conference. 222–225 (2018). · doi:10.1109/esscirc.2018.8494298
  33. Garripoli, C. et al. An a-IGZO asynchronous delta sigma modulator on foil achieving up to 43dB SNR and 40dB SNDR in 300Hz bandwidth. In Proc. 2017 IEEE International Solid-State Circuits Conference. 260–261 (2017). · doi:10.1109/isscc.2017.7870360
  34. Myny, K. The development of flexible integrated circuits based on thin-film transistors. Nat. Electron. 1, 30–39 (2018). · DOI · Paper page
  35. Tripathi, A. K., Myny, K., Hou, B., Wezenberg, K. & Gelinck, G. H. Electrical characterization of flexible InGaZnO transistors and 8-b transponder chip down to a bending radius of 2 mm. IEEE Trans. Elect. Dev. 62, 4063–4068 (2015). · doi:10.1109/ted.2015.2494694

Cited by

See all 137

Metadata

Authors
Zulqarnain, M., Stanzione, S., Rathinavel, G., Smout, S., Willegems, M., Myny, K., & Cantatore, E.
Venue
npj Flexible Electronics
Published
2020-07-15
Volume
4
Issue
1
ISSN
2397-4621
Cited by
137
References
18
Language
en
Licence

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.