The DOI matches its Crossref record; 106 of the 106 references it cites were found in a registry or an index.
Tutorial: design and fabrication of nanoparticle-based lateral-flow immunoassays
Open accessAbstract
Lateral-flow assays (LFAs) are quick, simple and cheap assays to analyze various samples at the point of care or in the field, making them one of the most widespread biosensors currently available. They have been successfully employed for the detection of a myriad of different targets (ranging from atoms up to whole cells) in all type of samples (including water, blood, foodstuff and environmental samples). Their operation relies on the capillary flow of the sample throughout a series of sequential pads, each with different functionalities aiming to generate a signal to indicate the absence/presence (and, in some cases, the concentration) of the analyte of interest. To have a user-friendly operation, their development requires the optimization of multiple, interconnected parameters that may overwhelm new developers. In this tutorial, we provide the readers with: (i) the basic knowledge to understand the principles governing an LFA and to take informed decisions during lateral flow strip design and fabrication, (ii) a roadmap for optimal LFA development independent of the specific application, (iii) a step-by-step example procedure for the assembly and operation of an LF strip for the detection of human IgG and (iv) an extensive troubleshooting section addressing the most frequent issues in designing, assembling and using LFAs. By changing only the receptors, the provided example procedure can easily be adapted for cost-efficient detection of a broad variety of targets. This tutorial describes how to design nanoparticle-based LFAs for detecting biomolecules. The authors provide guidance on how to select the appropriate lateral-flow strip components and bioreceptors as well as detection strategies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantum dot bioconjugates for imaging, labelling and sensing
Medintz, I. L., Uyeda, H. T., Goldman, E. R., & Mattoussi, H. (2005) · Nature Materials · doi:10.1038/nmat1390 · Cited by 6,229
Park, H., Harris, S. M., Boldenow, E., Aronoff, D. M., Rea, M., Xi, C., & Loch‐Caruso, R. (2024) · American Journal of Reproductive Immunology · doi:10.1111/aji.13807 · Cited by 2,087
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Posthuma-Trumpie, G. A., Korf, J., & van Amerongen, A. (2009) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-2287-2 · Cited by 1,540
Advanced methods of plant disease detection. A review
Martinelli, F., Scalenghe, R., Davino, S., Panno, S., Scuderi, G., Ruisi, P., Villa, P., Stroppiana, D., Boschetti, M., Goulart, L. R., et al. (2015) · Agronomy for Sustainable Development · doi:10.1007/s13593-014-0246-1 · Cited by 964
Advances in paper-based point-of-care diagnostics
Hu, J., Wang, S., Wang, L., Li, F., Pingguan-Murphy, B., Lu, T. J., & Xu, F. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2013.10.075 · Cited by 956
Advances in Rapid Detection Methods for Foodborne Pathogens
Zhao, X., Lin, C.-W., Wang, J., & Oh, D. H. (2014) · Journal of Microbiology and Biotechnology · doi:10.4014/jmb.1310.10013 · Cited by 714
Lateral flow assays: Principles, designs and labels
Bahadır, E. B., & Sezgintürk, M. K. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.06.006 · Cited by 682
Nanoparticle-based lateral flow biosensors
Quesada-González, D., & Merkoçi, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.05.050 · Cited by 597
Self-citation(2009) · Humana Press eBooks · doi:10.1007/978-1-59745-240-3 · Cited by 582
Replacing antibodies with aptamers in lateral flow immunoassay
Chen, A., & Yang, S. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.04.041 · Cited by 551
Paper-based nanobiosensors for diagnostics
Parolo, C., & Merkoçi, A. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35255a · Cited by 550
Self-citationSmartphone-based biosensors: A critical review and perspectives
Roda, A., Michelini, E., Zangheri, M., Di Fusco, M., Calabria, D., & Simoni, P. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.019 · Cited by 520
Nanomaterial-based devices for point-of-care diagnostic applications
Quesada-González, D., & Merkoçi, A. (2018) · Chemical Society Reviews · doi:10.1039/c7cs00837f · Cited by 393
Self-citationEffect of freezing and thawing rates on denaturation of proteins in aqueous solutions
Cao, E., Chen, Y., Cui, Z., & Foster, P. R. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10612 · Cited by 387
Ngom, B., Guo, Y., Wang, X., & Bi, D. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3661-4 · Cited by 386
Appropriate calibration curve fitting in ligand binding assays
Findlay, J. W. A., & Dillard, R. F. (2007) · The AAPS Journal · doi:10.1208/aapsj0902029 · Cited by 379
Zangheri, M., Cevenini, L., Anfossi, L., Baggiani, C., Simoni, P., Di Nardo, F., & Roda, A. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.08.048 · Cited by 373
Detection of genetically modified organisms in foods
Ahmed, F. E. (2002) · Trends in Biotechnology · doi:10.1016/s0167-7799(01)01920-5 · Cited by 373
Recent advances in high-sensitivity detection methods for paper-based lateral-flow assay
Nguyen, V.-T., Song, S., Park, S., & Joo, C. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112015 · Cited by 373
Sample preparation techniques for the determination of trace residues and contaminants in foods
Ridgway, K., Lalljie, S. P. D., & Smith, R. M. (2007) · Journal of Chromatography A · doi:10.1016/j.chroma.2007.01.134 · Cited by 354
Liu, J., Mazumdar, D., & Lu, Y. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200603106 · Cited by 346
Disposable Nucleic Acid Biosensors Based on Gold Nanoparticle Probes and Lateral Flow Strip
Mao, X., Ma, Y., Zhang, A., Zhang, L., Zeng, L., & Liu, G. (2009) · Analytical Chemistry · doi:10.1021/ac8024653 · Cited by 344
Gao, Z., Ye, H., Tang, D., Tao, J., Habibi, S., Minerick, A., Tang, D., & Xia, X. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02385 · Cited by 333
Boulware, D. R., Rolfes, M. A., Rajasingham, R., von Hohenberg, M., Qin, Z., Taseera, K., Schutz, C., Kwizera, R., Butler, E. K., Meintjes, G., et al. (2014) · Emerging Infectious Diseases · doi:10.3201/eid2001.130906 · Cited by 321
Choi, D. H., Lee, S. K., Oh, Y. K., Bae, B. W., Lee, S. D., Kim, S., Shin, Y.-B., & Kim, M.-G. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.01.019 · Cited by 278
Lateral-flow technology: From visual to instrumental
Mak, W. C., Beni, V., & Turner, A. P. F. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2015.10.017 · Cited by 264
Aptamer-based lateral flow assay for point of care cortisol detection in sweat
Dalirirad, S., & Steckl, A. J. (2019) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.11.161 · Cited by 259
Diagnosis of Schistosomiasis by Reagent Strip Test for Detection of Circulating Cathodic Antigen
van Dam, G. J., Wichers, J. H., Ferreira, T. M. F., Ghati, D., van Amerongen, A., & Deelder, A. M. (2004) · Journal of Clinical Microbiology · doi:10.1128/jcm.42.12.5458-5461.2004 · Cited by 248
Colloidal gold-based immunochromatographic assay for detection of ricin
Shyu, R.-H., Shyu, H.-F., Liu, H.-W., & Tang, S.-S. (2002) · Toxicon · doi:10.1016/s0041-0101(01)00193-3 · Cited by 246
Soh, J. H., Chan, H.-M., & Ying, J. Y. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100831 · Cited by 230
The Role of Nanoparticle Design in Determining Analytical Performance of Lateral Flow Immunoassays
Zhan, L., Guo, S.-Z., Song, F., Gong, Y., Xu, F., Boulware, D. R., McAlpine, M. C., Chan, W. C. W., & Bischof, J. C. (2017) · Nano Letters · doi:10.1021/acs.nanolett.7b02302 · Cited by 229
Sensitivity enhancement in lateral flow assays: a systems perspective
Bishop, J. D., Hsieh, H. V., Gasperino, D. J., & Weigl, B. H. (2019) · Lab on a Chip · doi:10.1039/c9lc00104b · Cited by 227
Significantly Improved Analytical Sensitivity of Lateral Flow Immunoassays by Using Thermal Contrast
Qin, Z., Chan, W. C. W., Boulware, D. R., Akkin, T., Butler, E. K., & Bischof, J. C. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200997 · Cited by 221
Advanced printing and deposition methodologies for the fabrication of biosensors and biodevices
Gonzalez-Macia, L., Morrin, A., Smyth, M. R., & Killard, A. J. (2010) · The Analyst · doi:10.1039/b916888e · Cited by 211
Nanomaterial-enhanced paper-based biosensors
Ge, X., Asiri, A. M., Du, D., Wen, W., Wang, S., & Lin, Y. (2014) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2014.03.008 · Cited by 208
Brangel, P., Sobarzo, A., Parolo, C., Miller, B. S., Howes, P. D., Gelkop, S., Lutwama, J. J., Dye, J. M., McKendry, R. A., Lobel, L., et al. (2018) · ACS Nano · doi:10.1021/acsnano.7b07021 · Cited by 203
Self-citationTowards Lateral Flow Quantitative Assays: Detection Approaches
Urusov, A. E., Zherdev, A. V., & Dzantiev, B. B. (2019) · Biosensors · doi:10.3390/bios9030089 · Cited by 202
Lateral and Vertical Flow Assays for Point‐of‐Care Diagnostics
Jiang, N., Ahmed, R., Damayantharan, M., Ünal, B., Butt, H., & Yetisen, A. K. (2019) · Advanced Healthcare Materials · doi:10.1002/adhm.201900244 · Cited by 201
Xu, S., Zhang, G., Fang, B., Xiong, Q., Duan, H., & Lai, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b08789 · Cited by 194
Morales-Narváez, E., Naghdi, T., Zor, E., & Merkoçi, A. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02383 · Cited by 186
Self-citationYang, J., Wang, K., Xu, H., Yan, W., Jin, Q., & Cui, D. (2019) · Talanta · doi:10.1016/j.talanta.2019.04.054 · Cited by 186
Preparation of paper-based devices for reagentless electrochemical (bio)sensor strips
Cinti, S., Moscone, D., & Arduini, F. (2019) · Nature Protocols · doi:10.1038/s41596-019-0186-y · Cited by 182
Self-citationAmorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays
Posthuma-Trumpie, G. A., Wichers, J. H., Koets, M., Berendsen, L. B. J. M., & van Amerongen, A. (2012) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-011-5340-5 · Cited by 176
Distance-based microfluidic quantitative detection methods for point-of-care testing
Tian, T., Li, J., Song, Y., Zhou, L., Zhu, Z., & Yang, C. J. (2016) · Lab on a Chip · doi:10.1039/c5lc01562f · Cited by 171
Gong, Y., Zheng, Y., Jin, B., You, M., Wang, J., Li, X., Lin, M., Xu, F., & Li, F. (2019) · Talanta · doi:10.1016/j.talanta.2019.03.105 · Cited by 166
A rapid, instrument-free, sample-to-result nucleic acid amplification test
Lafleur, L. K., Bishop, J. D., Heiniger, E. K., Gallagher, R. P., Wheeler, M. D., Kauffman, P., Zhang, X., Kline, E. C., Buser, J. R., Kumar, S., et al. (2016) · Lab on a Chip · doi:10.1039/c6lc00677a · Cited by 165
Electrochemical lateral flow immunosensor for detection and quantification of dengue NS1 protein
Sinawang, P. D., Rai, V., Ionescu, R. E., & Marks, R. S. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.09.048 · Cited by 158
Statistical Method for Determining and Comparing Limits of Detection of Bioassays
Holstein, C. A., Griffin, M., Hong, J., & Sampson, P. D. (2015) · Analytical Chemistry · doi:10.1021/acs.analchem.5b02082 · Cited by 152
Challenges of the Nano–Bio Interface in Lateral Flow and Dipstick Immunoassays
de Puig, H., Bosch, I., Gehrke, L., & Hamad‐Schifferli, K. (2017) · Trends in biotechnology · doi:10.1016/j.tibtech.2017.09.001 · Cited by 136
Nash, M. A., Waitumbi, J. N., Hoffman, A. S., Yager, P., & Stayton, P. S. (2012) · ACS Nano · doi:10.1021/nn3015008 · Cited by 134
Immunochromatographic Assay on Thread
Zhou, G., Mao, X., & Juncker, D. (2012) · Analytical Chemistry · doi:10.1021/ac301082d · Cited by 131
Kim, J., Kwon, J.-H., Jang, J., Lee, H., Kim, S. K., Hahn, Y. K., Kim, S. K., Lee, K. H., Lee, S., Pyo, H., et al. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.04.047 · Cited by 128
Kim, H., Chung, D. R., & Kang, M. (2019) · The Analyst · doi:10.1039/c8an02295j · Cited by 126
Lateral flow assay using aptamer-based sensing for on-site detection of dopamine in urine
Dalirirad, S., & Steckl, A. J. (2020) · Analytical Biochemistry · doi:10.1016/j.ab.2020.113637 · Cited by 119
Analytical Tools to Improve Optimization Procedures for Lateral Flow Assays
Hsieh, H. V., Dantzler, J., & Weigl, B. H. (2017) · Diagnostics · doi:10.3390/diagnostics7020029 · Cited by 117
Parolo, C., de la Escosura‐Muñiz, A., Polo, E., Grazú, V., de la Fuente, J. M., & Merkoçi, A. (2013) · ACS Applied Materials & Interfaces · doi:10.1021/am4029153 · Cited by 113
Self-citationDevelopment of a Rainbow Lateral Flow Immunoassay for the Simultaneous Detection of Four Mycotoxins
Foubert, A., Beloglazova, N. V., Gordienko, A., Tessier, M. D., Drijvers, E., Hens, Z., & Saeger, S. D. (2016) · Journal of Agricultural and Food Chemistry · doi:10.1021/acs.jafc.6b04157 · Cited by 111
Mitigating the Hook Effect in Lateral Flow Sandwich Immunoassays Using Real-Time Reaction Kinetics
Rey, E. G., O’Dell, D., Mehta, S., & Erickson, D. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.7b00638 · Cited by 110
Nardo, F. D., Cavalera, S., Baggiani, C., Giovannoli, C., & Anfossi, L. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b11559 · Cited by 109
Oliveira-Rodríguez, M., Serrano‐Pertierra, E., Garcı́a, A. C., López‐Martín, S., Yáñez‐Mó, M., Cernuda‐Morollón, E., & Blanco‐López, M. C. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2016.08.001 · Cited by 107
Development a stacking pad design for enhancing the sensitivity of lateral flow immunoassay
Tsai, T., Huang, T.-H., Chen, C., Chou, Y., Chou, Y., & Chen, C. (2018) · Scientific Reports · doi:10.1038/s41598-018-35694-9 · Cited by 107
Wang, Y., Qin, Z., Boulware, D. R., Pritt, B. S., Sloan, L. M., González, I. J., Bell, D., Rees-Channer, R. R., Chiodini, P. L., Chan, W. C. W., et al. (2016) · Analytical Chemistry · doi:10.1021/acs.analchem.6b03406 · Cited by 106
Improving Lateral Flow Assay Performance Using Computational Modeling
Gasperino, D. J., Baughman, T. A., Hsieh, H. V., Bell, D., & Weigl, B. H. (2018) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061417-125737 · Cited by 106
Oh, Y. K., Joung, H., Han, H. S., Suk, H., & Kim, M. (2014) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.04.032 · Cited by 103
Greenwald, R., Esfandiari, J., Lesellier, S., Houghton, R. L., Pollock, J. M., Aagaard, C., Andersen, P. L., Hewinson, R. G., Chambers, M. A., & Lyashchenko, K. P. (2003) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/s0732-8893(03)00046-4 · Cited by 102
Choi, J. R., Hu, J., Feng, S., Abas, W. A. B. W., Pingguan‐Murphy, B., & Xu, F. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.12.005 · Cited by 102
An integrated lateral flow assay for effective DNA amplification and detection at the point of care
Choi, J. R., Hu, J., Gong, Y. M., Feng, S., Abas, W. A. B. W., Pingguan‐Murphy, B., & Xu, F. (2016) · The Analyst · doi:10.1039/c5an02532j · Cited by 99
Salt-Induced Aggregation of Negatively Charged Gold Nanoparticles Confined in a Polymer Brush Matrix
Christau, S., Moeller, T., Genzer, J., Koehler, R., & von Klitzing, R. (2017) · Macromolecules · doi:10.1021/acs.macromol.7b00866 · Cited by 96
Upconversion fluorescent strip sensor for rapid determination of Vibrio anguillarum
Zhao, P., Wu, Y., Zhu, Y., Yang, X., Jiang, X. Y., Xiao, J., Zhang, Y., & Li, C. (2014) · Nanoscale · doi:10.1039/c3nr06549a · Cited by 92
GMR sensors and magnetic nanoparticles for immuno-chromatographic assays
Marquina, C., Teresa, J. M. D., Serrate, D., Marzo, J., Cardoso, F. A., Saurel, D., Cardoso, S., Freitas, P. P., & Ibarra, M. R. (2012) · Journal of Magnetism and Magnetic Materials · doi:10.1016/j.jmmm.2012.02.074 · Cited by 88
Leung, W., Chan, C. P.-Y., Rainer, T. H., Ip, M., Cautherley, G. W. H., & Renneberg, R. (2008) · Journal of Immunological Methods · doi:10.1016/j.jim.2008.03.009 · Cited by 87
Tan, G., Zhao, Y., Wang, M., Chen, X., Wang, B., & Li, Q. X. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2019.126055 · Cited by 86
Luo, K., Kim, H., Oh, M., & Kim, Y. (2018) · Critical Reviews in Food Science and Nutrition · doi:10.1080/10408398.2018.1516623 · Cited by 83
Kong, D., Wu, X., Li, Y., Liu, L., Song, S., Zheng, Q., Kuang, H., & Xu, C. (2018) · Food Chemistry · doi:10.1016/j.foodchem.2018.07.075 · Cited by 79
Signal enhancement on gold nanoparticle-based lateral flow tests using cellulose nanofibers
Quesada-González, D., Stefani, C., González, I., de la Escosura‐Muñiz, A., Domingo, N., Mutjé, P., & Merkoçi, A. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.111407 · Cited by 79
Self-citationEdwards, K. A., & Baeumner, A. J. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0705-x · Cited by 77
Hassan, A. H. A., Bergua, J. F., Morales‐Narváez, E., & Mekoçi, A. (2019) · Food Chemistry · doi:10.1016/j.foodchem.2019.124965 · Cited by 76
Self-citationDam, T. K., Torres, M., Brewer, C. F., & Casadevall, A. (2008) · Journal of Biological Chemistry · doi:10.1074/jbc.m806473200 · Cited by 72
Wu, Z., Shen, H., Hu, J., Fu, Q., Yao, C., Yu, S., Xiao, W., & Tang, Y. (2017) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-017-0491-7 · Cited by 70
Development of Multiplexed Infectious Disease Lateral Flow Assays: Challenges and Opportunities
Hanafiah, K. M., Arifin, N., Bustami, Y., Noordin, R., Garcia, M. L., & Anderson, D. (2017) · Diagnostics · doi:10.3390/diagnostics7030051 · Cited by 67
Chen, J., Huang, Z., Meng, H., Zhang, L., Ji, D., Liu, J., Yu, F., Qu, L., & Li, Z. (2018) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2018.01.101 · Cited by 66
Lateral Flow Technology for Field-Based Applications—Basics and Advanced Developments
O’Farrell, B. (2015) · Topics in companion animal medicine · doi:10.1053/j.tcam.2015.12.003 · Cited by 63
Ryu, Y., Jin, Z., Kang, M. S., & Kim, H. (2011) · BioChip Journal · doi:10.1007/s13206-011-5301-2 · Cited by 62
Plasmonic enhancement in lateral flow sensors for improved sensing of E. coli O157:H7
Ren, W., Ballou, D. R., FitzGerald, R., & Irudayaraj, J. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.10.066 · Cited by 61
Algorithms for immunochromatographic assay: review and impact on future application
Qin, Q., Wang, K., Yang, J., Xu, H., Cao, B., Wo, Y., Jin, Q., & Cui, D. (2019) · The Analyst · doi:10.1039/c9an00964g · Cited by 61
Magnetic immunochromatographic test for histamine detection in wine
Moyano, A., Salvador, M., Martínez-García, J. C., Socoliuc, V., Vékás, L., Peddis, D., Álvarez, M. A., Fernández, M., Rivas, M., & Blanco‐López, M. C. (2019) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-019-02031-6 · Cited by 59
Wiederhold, N. P., Najvar, L. K., Bocanegra, R. A., Kirkpatrick, W. R., Patterson, T. F., & Thornton, C. R. (2012) · Journal of Clinical Microbiology · doi:10.1128/jcm.02142-12 · Cited by 58
Electrochemical Lateral Flow Devices: Towards Rapid Immunomagnetic Assays
Ruiz‐Vega, G., Κιτσαρά, Μ., Pellitero, M. A., Baldrich, E., & del Campo, F. J. (2017) · ChemElectroChem · doi:10.1002/celc.201600902 · Cited by 58
Ang, S. H., Rambeli, M., Thevarajah, T. M., Alias, Y. B., & Khor, S. M. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.045 · Cited by 57
Nanoparticles in Biology and Medicine
(2012) · Methods in molecular biology · doi:10.1007/978-1-61779-953-2 · Cited by 56
Hu, Q., Wei, Q., Zhang, P., Li, S., Xue, L., Yang, R., Wang, C., & Zhou, L. (2018) · The Analyst · doi:10.1039/c8an00651b · Cited by 53
Oh, H.-K., Kim, J., Kim, J., & Kim, M. (2018) · The Analyst · doi:10.1039/c8an00719e · Cited by 47
Zamora‐Gálvez, A., Morales‐Narváez, E., Romero, J., & Merkoçi, A. (2017) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2017.09.013 · Cited by 46
Self-citationYan, X., Wang, K., Lu, W., et al. (2016) · Nanoscale Research Letters · doi:10.1186/s11671-016-1355-3 · Cited by 43
Dieplinger, B., Egger, M., Gegenhuber, A., Haltmayer, M., & Mueller, T. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.10.015 · Cited by 39
Apilux, A., Rengpipat, S., Suwanjang, W., & Chailapakul, O. (2018) · EXCLI journal · doi:10.17179/excli2018-1824 · Cited by 33
Zhao, L., Chen, H., Feng, S., Liu, K., & Wang, P. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvz023 · Cited by 33
Determination of High-affinity Antibody-antigen Binding Kinetics Using Four Biosensor Platforms
Yang, D., Singh, A., Wu, H. H., et al. (2017) · Journal of Visualized Experiments · doi:10.3791/55659 · Cited by 31
Sakurai, A., Takayama, K., Nomura, N., Yamamoto, N., Sakoda, Y., Kobayashi, Y., Kida, H., & Shibasaki, F. (2014) · Journal of Virological Methods · doi:10.1016/j.jviromet.2014.08.025 · Cited by 29
Quantifying Biomolecular Binding Constants using Video Paper Analytical Devices
Miller, B. S., Parolo, C., Turbé, V., Keane, C. E., Gray, E. R., & McKendry, R. A. (2018) · Chemistry - A European Journal · doi:10.1002/chem.201802394 · Cited by 24
Self-citationOu, L., Lv, Q., Wu, C., Hao, H., Zheng, Y., & Jiang, Y. (2016) · Journal of Microbiological Methods · doi:10.1016/j.mimet.2016.03.006 · Cited by 23
Mosley, G. L., Nguyen, P. T., Wu, B. M., & Kamei, D. T. (2016) · Lab on a Chip · doi:10.1039/c6lc00518g · Cited by 22
Asiaei, S., Bidgoli, M. R., Zadehkafi, A., Saderi, N., & Siavashi, M. (2018) · Clinica Chimica Acta · doi:10.1016/j.cca.2018.10.001 · Cited by 21
Simple lateral flow assays for microbial detection in stool
Henderson, W. A., Xiang, L., Fourie, N. H., Abey, S. K., Ferguson, E. G., Diallo, A. F., Kenea, N. D., & Kim, C. H. (2018) · Analytical Methods · doi:10.1039/c8ay01475b · Cited by 19
Nawattanapaiboon, K., Prombun, P., Santanirand, P., Vongsakulyanon, A., Srikhirin, T., Sutapun, B., & Kiatpathomchai, W. (2016) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21935 · Cited by 15
Cited by
Ultrasensitive and Highly Specific Lateral Flow Assays for Point-of-Care Diagnosis
Liu, Y., Zhan, L., Qin, Z., Sackrison, J., & Bischof, J. C. (2021) · ACS Nano · doi:10.1021/acsnano.0c10035 · Cited by 626
Di Nardo, F., Chiarello, M., Cavalera, S., Baggiani, C., & Anfossi, L. (2021) · Sensors · doi:10.3390/s21155185 · Cited by 430
Toward Next Generation Lateral Flow Assays: Integration of Nanomaterials
Sena-Torralba, A., Álvarez-Diduk, R., Parolo, C., Piper, A., & Merkoçi, A. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c01012 · Cited by 388
Self-citationHang, Y., Boryczka, J., & Wu, N. (2022) · Chemical Society Reviews · doi:10.1039/c9cs00621d · Cited by 377
Lateral flow test engineering and lessons learned from COVID-19
Budd, J., Miller, B. S., Weckman, N. E., Cherkaoui, D., Huang, D., Decruz, A. T., Fongwen, N., Han, G.-R., Broto, M., Estcourt, C. S., et al. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-022-00007-3 · Cited by 308
Metadata
- Authors
- Parolo, C., Sena-Torralba, A., Bergua, J. F., Calucho, E., Fuentes-Chust, C., Hu, L., Rivas, L., Álvarez-Diduk, R., Nguyen, E. P., Cinti, S., Quesada-González, D., & Merkoçi, A.
- Venue
- Nature Protocols
- Published
- 2020-10-23
- Volume
- 15
- Issue
- 12
- Pages
- 3788-3816
- ISSN
- 1750-2799 (ISSN-L)
- 1754-2189
- OpenAlex
- W3094213759
- Cited by
- 576
- References
- 106
- FWCI
- 16.37
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.