Precision Medicine and Artificial Intelligence: A Pilot Study on Deep Learning for Hypoglycemic Events Detection based on ECG
Open accessThe DOI matches its Crossref record; 92 of the 92 references it cites were found in a registry or an index.
Abstract
Tracking the fluctuations in blood glucose levels is important for healthy subjects and crucial diabetic patients. Tight glucose monitoring reduces the risk of hypoglycemia, which can result in a series of complications, especially in diabetic patients, such as confusion, irritability, seizure and can even be fatal in specific conditions. Hypoglycemia affects the electrophysiology of the heart. However, due to strong inter-subject heterogeneity, previous studies based on a cohort of subjects failed to deploy electrocardiogram (ECG)-based hypoglycemic detection systems reliably. The current study used personalised medicine approach and Artificial Intelligence (AI) to automatically detect nocturnal hypoglycemia using a few heartbeats of raw ECG signal recorded with non-invasive, wearable devices, in healthy individuals, monitored 24 hours for 14 consecutive days. Additionally, we present a visualisation method enabling clinicians to visualise which part of the ECG signal (e.g., T-wave, ST-interval) is significantly associated with the hypoglycemic event in each subject, overcoming the intelligibility problem of deep-learning methods. These results advance the feasibility of a real-time, non-invasive hypoglycemia alarming system using short excerpts of ECG signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
(2008) · Journal of Machine Learning Research · Cited by 33,051
Grad-CAM: Visual Explanations from Deep Networks via Gradient-Based Localization
Selvaraju, R. R., Cogswell, M., Das, A., Vedantam, R., Parikh, D., & Batra, D. (2017) · 2017 IEEE International Conference on Computer Vision (ICCV) · doi:10.1109/iccv.2017.74 · Cited by 24,513
(2010) · Cited by 14,134
(2010) · International Conference on Machine Learning · Cited by 13,995
Representation Learning: A Review and New Perspectives
Bengio, Y., Courville, A., & Vincent, P. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2013.50 · Cited by 13,001
TensorFlow: Large-Scale Machine Learning on Heterogeneous Distributed Systems
Abadi, M., Agarwal, A., Barham, P., Brevdo, E., Chen, Z., Citro, C., Corrado, G. S., Davis, A., Dean, J., Devin, M., et al. (2016) · arXiv · doi:10.48550/arxiv.1603.04467 · Cited by 9,408
Glucose clamp technique: a method for quantifying insulin secretion and resistance.
DeFronzo, R. A., Tobin, J. D., & Andres, R. (1979) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1979.237.3.e214 · Cited by 7,425
Hannun, A. Y., Rajpurkar, P., Haghpanahi, M., Tison, G. H., Bourn, C., Turakhia, M. P., & Ng, A. Y. (2019) · Nature Medicine · doi:10.1038/s41591-018-0268-3 · Cited by 3,148
Classification and Diagnosis of Diabetes
Fajans, S. S. (1990) · Medical Entomology and Zoology · Cited by 2,359
Time series classification from scratch with deep neural networks: A strong baseline
Wang, Z., Yan, W., & Oates, T. (2017) · 2017 International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2017.7966039 · Cited by 2,299
Real-Time Patient-Specific ECG Classification by 1-D Convolutional Neural Networks
Kiranyaz, S., Ince, T., & Gabbouj, M. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2468589 · Cited by 1,912
Understanding and misunderstanding randomized controlled trials
Deaton, A., & Cartwright, N. (2018) · Social Science & Medicine · doi:10.1016/j.socscimed.2017.12.005 · Cited by 1,841
2. Classification and Diagnosis of Diabetes
American Diabetes Association (2017) · Diabetes Care · doi:10.2337/dc17-s005 · Cited by 1,603
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Bagnall, A., Lines, J., Bostrom, A., Large, J., & Keogh, E. (2017) · Data Mining and Knowledge Discovery · doi:10.1007/s10618-016-0483-9 · Cited by 1,377
Personalized medicine: Time for one-person trials
Schork, N. J. (2015) · Nature · doi:10.1038/520609a · Cited by 1,223
Beck, R. W., Riddlesworth, T., Ruedy, K., Ahmann, A., Bergenstal, R., Haller, S., Kollman, C., Kruger, D., McGill, J. B., Polonsky, W., et al. (2017) · JAMA · doi:10.1001/jama.2016.19975 · Cited by 1,185
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893
Epidemiology of severe hypoglycemia in the diabetes control and complications trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)80085-z · Cited by 807
Epidemiology of severe hypoglycemia in the Diabetes Control and Complications Trial
(1991) · The American Journal of Medicine · doi:10.1016/0002-9343(91)90605-w · Cited by 807
The Performance and Usability of a Factory-Calibrated Flash Glucose Monitoring System
Bailey, T., Bode, B. W., Christiansen, M. P., Klaff, L. J., & Alva, S. (2015) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2014.0378 · Cited by 685
Yetisen, A. K., Martinez‐Hurtado, J. L., Ünal, B., Khademhosseini, A., & Butt, H. (2018) · Advanced Materials · doi:10.1002/adma.201706910 · Cited by 569
Drug development in the era of precision medicine
Dugger, S. A., Platt, A., & Goldstein, D. B. (2018) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2017.226 · Cited by 493
From Big Data to Precision Medicine
Hulsen, T., Jamuar, S. S., Moody, A. R., Karnes, J. H., Varga, O., Hedensted, S., Spreafico, R., Hafler, D. A., & McKinney, E. F. (2019) · Frontiers in Medicine · doi:10.3389/fmed.2019.00034 · Cited by 459
From hype to reality: data science enabling personalized medicine
Fröhlich, H., Balling, R., Beerenwinkel, N., Kohlbacher, O., Kumar, S., Lengauer, T., Maathuis, M. H., Moreau, Y., Murphy, S. A., Przytycka, T. M., et al. (2018) · BMC Medicine · doi:10.1186/s12916-018-1122-7 · Cited by 414
Pourbabaee, B., Roshtkhari, M. J., & Khorasani, K. (2018) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2017.2705582 · Cited by 411
Chow, E., Bernjak, A., Williams, S., Fawdry, R. A., Hibbert, S., Freeman, J., Sheridan, P. J., & Heller, S. R. (2014) · Diabetes · doi:10.2337/db13-0468 · Cited by 403
Hyperglycemia and the Pathobiology of Diabetic Complications
Aronson, D. (2008) · Advances In Cardiology · doi:10.1159/000115118 · Cited by 362
The role of artificial intelligence in precision medicine
Mesko, B. (2017) · Expert Review of Precision Medicine and Drug Development · doi:10.1080/23808993.2017.1380516 · Cited by 343
Are innovation and new technologies in precision medicine paving a new era in patients centric care?
Seyhan, A. A., & Carini, C. (2019) · Journal of Translational Medicine · doi:10.1186/s12967-019-1864-9 · Cited by 299
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293
Current and Emerging Technology for Continuous Glucose Monitoring
Chen, C., Zhao, X.-L., Li, Z.-H., Zhu, Z.-G., Qian, S.-H., & Flewitt, A. (2017) · Sensors · doi:10.3390/s17010182 · Cited by 291
Noninvasive Monitoring of Blood Glucose with Raman Spectroscopy
Pandey, R., Paidi, S. K., Valdez, T. A., Zhang, C., Spegazzini, N., Dasari, R. R., & Barman, I. (2017) · Accounts of Chemical Research · doi:10.1021/acs.accounts.6b00472 · Cited by 290
Tura, A., Maran, A., & Pacini, G. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2006.10.027 · Cited by 283
Zheng, Y., Liu, Q., Chen, E., Ge, Y., & Zhao, J. L. (2016) · Frontiers of Computer Science · doi:10.1007/s11704-015-4478-2 · Cited by 273
Mechanisms of abnormal cardiac repolarization during insulin-induced hypoglycemia
Robinson, R. T. C. E., Harris, N. D., Ireland, R. H., Lee, S., Newman, C., & Heller, S. R. (2003) · Diabetes · doi:10.2337/diabetes.52.6.1469 · Cited by 264
Convolutional Recurrent Neural Networks for Electrocardiogram Classification
Zihlmann, M., Perekrestenko, D., & Tschannen, M. (2017) · Computing in Cardiology Conference (CinC) · doi:10.22489/cinc.2017.070-060 · Cited by 246
(1991) · PubMed · Cited by 245
Recent advances in noninvasive glucose monitoring
Chung, J., So, H., Choi, & Wong, T. K. S. (2012) · Medical Devices: Evidence and Research · doi:10.2147/mder.s28134 · Cited by 218
Fokkert, M. J., van Dijk, P. R., Edens, M. A., Abbes, S., de Jong, D., Slingerland, R. J., & Bilo, H. J. G. (2017) · BMJ Open Diabetes Research & Care · doi:10.1136/bmjdrc-2016-000320 · Cited by 209
Understanding and Misunderstanding Randomized Controlled Trials
Deaton, A., & Cartwright, N. D. (2016) · National Bureau of Economic Research · doi:10.3386/w22595 · Cited by 183
Neural Network-Based Real-Time Prediction of Glucose in Patients with Insulin-Dependent Diabetes
Pappada, S. M., Cameron, B. D., Rosman, P. M., Bourey, R. E., Papadimos, T. J., Olorunto, W., & Borst, M. J. (2011) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2010.0104 · Cited by 182
Montesinos, L., Castaldo, R., & Pecchia, L. (2018) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2771383 · Cited by 171
Self-citationArtificial intelligence for the electrocardiogram
Mincholé, A., & Rodríguez, B. (2019) · Nature Medicine · doi:10.1038/s41591-018-0306-1 · Cited by 170
Hypoglycemia Prediction Using Machine Learning Models for Patients With Type 2 Diabetes
Sudharsan, B., Peeples, M., & Shomali, M. (2015) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814554260 · Cited by 162
A convolutional neural network approach to detect congestive heart failure
Porumb, M., Iadanza, E., Massaro, S., & Pecchia, L. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101597 · Cited by 158
Self-citationPrecision Medicine Is Not Just Genomics: The Right Dose for Every Patient
Peck, R. (2017) · The Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010617-052446 · Cited by 142
Freestyle Libre Glucose Monitoring System
Blum, A. K. (2018) · Clinical Diabetes · doi:10.2337/cd17-0130 · Cited by 139
Damiano, E. R., McKeon, K., El-Khatib, F. H., Zheng, H., Nathan, D. M., & Russell, S. J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814532203 · Cited by 139
Robinson, R. T. C. E., Harris, N. D., Ireland, R. H., Macdonald, I. A., & Heller, S. R. (2004) · Diabetologia · doi:10.1007/s00125-003-1292-4 · Cited by 137
Kropff, J., Bruttomesso, D., Doll, W., Farret, A., Galasso, S., Luijf, Y. M., Mader, J. K., Place, J., Boscari, F., Pieber, T. R., et al. (2015) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12378 · Cited by 132
Aberer, F., Hajnsek, M., Rumpler, M., Zenz, S., Baumann, P. M., Elsayed, H., Puffing, A., Treiber, G., Pieber, T. R., Sourij, H., et al. (2017) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.12907 · Cited by 132
Comparative accuracy of 17 point-of-care glucose meters
Ekhlaspour, L., Mondesir, D., Lautsch, N., Balliro, C., Hillard, M., Magyar, K., Radocchia, L. G., Esmaeili, A., Sinha, M., & Russell, S. J. (2017) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816672237 · Cited by 127
Development of a Neural Network for Prediction of Glucose Concentration in Type 1 Diabetes Patients
Pappada, S. M., Cameron, B. D., & Rosman, P. M. (2008) · Journal of Diabetes Science and Technology · doi:10.1177/193229680800200507 · Cited by 124
Ajjan, R. A., Cummings, M. H., Jennings, P., Leelarathna, L., Rayman, G., & Wilmot, E. G. (2018) · Diabetes and Vascular Disease Research · doi:10.1177/1479164118756240 · Cited by 111
Electrocardiographic Alterations during Hyperinsulinemic Hypoglycemia in Healthy Subjects
Laitinen, T., Lyyra‐Laitinen, T., Huopio, H., Vauhkonen, I., Halonen, T., Hartikainen, J., Niskanen, L., & Laakso, M. (2008) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2008.00208.x · Cited by 107
Invasiveness as a Barrier to Self-Monitoring of Blood Glucose in Diabetes
Wagner, J., Malchoff, C., & Abbott, G. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.612 · Cited by 106
Al Hayek, A. A., Robert, A. A., & Al Dawish, M. A. (2017) · Clinical Medicine Insights: Endocrinology and Diabetes · doi:10.1177/1179551417746957 · Cited by 103
Bonora, B. M., Maran, A., Ciciliot, S., Avogaro, A., & Fadini, G. P. (2016) · Journal of Endocrinological Investigation · doi:10.1007/s40618-016-0495-8 · Cited by 101
Nakagawa, M., Iwao, T., Ishida, S., Yonemochi, H., Fujino, T., Saikawa, T., & Ito, M. (1998) · Heart · doi:10.1136/hrt.79.5.493 · Cited by 93
Effects of controlled hypoglycaemia on cardiac repolarisation in patients with type 1 diabetes
Koivikko, M. L., Karsikas, M., Salmela, P. I., Tapanainen, J. S., Ruokonen, A., Seppänen, T., Huikuri, H. V., & Perkiömäki, J. S. (2008) · Diabetologia · doi:10.1007/s00125-007-0902-y · Cited by 89
Cichosz, S. L., Frystyk, J., Hejlesen, O. K., Tarnow, L., & Fleischer, J. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814528838 · Cited by 88
Gamsey, S., Suri, J. T., Wessling, R. A., & Singaram, B. (2006) · Langmuir · doi:10.1021/la0617053 · Cited by 70
Christensen, T. F., Tarnow, L., Randløv, J., Kristensen, L. E., Struijk, J. J., Eldrup, E., & Hejlesen, O. K. (2010) · Diabetologia · doi:10.1007/s00125-010-1802-0 · Cited by 66
Freckmann, G., Link, M., Pleus, S., Westhoff, A., Kamecke, U., & Haug, C. (2018) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0105 · Cited by 64
A Novel Short-Term Event Extraction Algorithm for Biomedical Signals
Yazdani, S., Fallet, S., & Vésin, J.-M. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2718179 · Cited by 63
Non-invasive hypoglycemia monitoring system using extreme learning machine for Type 1 diabetes
Ling, S. H., San, P. P., & Nguyen, H. T. (2016) · ISA Transactions · doi:10.1016/j.isatra.2016.05.008 · Cited by 62
Polisena, J., Castaldo, R., Ciani, O., Federici, C., Borsci, S., Ritrovato, M., Clark, D. J., & Pecchia, L. (2018) · International Journal of Technology Assessment in Health Care · doi:10.1017/s0266462318000314 · Cited by 55
Self-citationFree-living inferential modeling of blood glucose level using only noninvasive inputs
Rollins, D. K., Bhandari, N., Kleinedler, J., Kotz, K., Strohbehn, A., Boland, L., Murphy, M., André, D., Vyas, N., Welk, G. J., et al. (2009) · Journal of Process Control · doi:10.1016/j.jprocont.2009.09.008 · Cited by 52
Identification of Hypoglycemia and Hyperglycemia in Type 1 Diabetic patients using ECG parameters
Nguyen, L. L., Su, S. W., & Nguyen, H. T. (2012) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2012.6346525 · Cited by 51
Randomized clinical trials and personalized medicine: A commentary on deaton and cartwright
Schork, N. J. (2018) · Social Science & Medicine · doi:10.1016/j.socscimed.2018.04.033 · Cited by 49
Zanderigo, F., Sparacino, G., Kovatchev, B. P., & Cobelli, C. (2007) · Journal of Diabetes Science and Technology · doi:10.1177/193229680700100508 · Cited by 46
Deep learning framework for detection of hypoglycemic episodes in children with type 1 diabetes
San, P. P., Ling, S. H., & Nguyen, H. T. (2016) · 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2016.7591483 · Cited by 42
Ling, S. H., & Nguyen, H. T. (2011) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2010.2103953 · Cited by 41
Measurement of high resolution ECG QT interval during controlled euglycaemia and hypoglycaemia
Ireland, R. H., Robinson, R. T. C. E., Heller, S. R., Marques, J. L. B., & Harris, N. D. (2000) · Physiological Measurement · doi:10.1088/0967-3334/21/2/309 · Cited by 38
Ling, S. H., & Nguyen, H. T. (2012) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2012.04.003 · Cited by 37
Robinson, R. T. C. E., Harris, N. D., Ireland, R. H., Lindholm, A., & Heller, S. R. (2003) · British Journal of Clinical Pharmacology · doi:10.1046/j.1365-2125.2003.01726.x · Cited by 35
Lipponen, J. A., Kemppainen, J., Karjalainen, P. A., Laitinen, T. P., Mikola, H., Kärki, T., & Tarvainen, M. P. (2011) · Physiological Measurement · doi:10.1088/0967-3334/32/6/003 · Cited by 31
Sobel, S. I., Chomentowski, P. J., Vyas, N., André, D., & Toledo, F. G. S. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296813516182 · Cited by 29
Electrocardiographic Changes During Insulin-Induced Hypoglycemia in Healthy Subjects
Meinhold, J., Heise, T., Rave, K., & Heinemann, L. (1998) · Hormone and Metabolic Research · doi:10.1055/s-2007-978960 · Cited by 25
The Normal ECG and its (Normal) Variants
Gertsch, M. (2004) · Springer eBooks · doi:10.1007/978-3-662-10315-9_4 · Cited by 20
Clough, A. J., Hilmer, S. N., Naismith, S. L., Kardell, L. D., & Gnjidic, D. (2017) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2017.09.015 · Cited by 20
Evolved fuzzy reasoning model for hypoglycaemic detection
Ling, S. H., Nuryani, N., & Nguyen, H. T. (2010) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2010.5626450 · Cited by 19
Hypoglycemia detection based on cardiac repolarization features
Lipponen, J. A., Kemppainen, J., Karjalainen, P. A., Laitinen, T. P., Mikola, H., Karki, T., & Tarvainen, M. P. (2011) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2011.6091163 · Cited by 17
Lipponen, J. A., Tarvainen, M. P., Laitinen, T. P., Lyyra‐Laitinen, T., & Karjalainen, P. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2037492 · Cited by 17
Coated glucose sensors dodge recalibration
Zhang, E., & Cao, Z. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0329-4 · Cited by 14
Hypoglycemia detection: multiple regression-based combinational neural logic approach
Ling, S. H., San, P. P., Lam, H., & Nguyen, H. T. (2015) · Soft Computing · doi:10.1007/s00500-015-1809-z · Cited by 12
Ling, S. H., San, P. P., Lam, H., & Nguyen, H. T. (2014) · IEEE Congress on Evolutionary Computation (CEC) · doi:10.1109/cec.2014.6900229 · Cited by 7
Circadian Pattern of T Wave Morphology
Batchvarov, V. N. (2004) · Wiley eBooks · doi:10.1002/9780470987483.ch36 · Cited by 2
Marques (1997) · doi:10.1002/(sici)1096-9136(199708)14:8<648::aid-dia418>3.0.co;2-1
Cited by
Rajpurkar, P., Chen, E., Banerjee, O., & Topol, E. J. (2022) · Nature Medicine · doi:10.1038/s41591-021-01614-0 · Cited by 3,212
“Additionally, ML methods have been used to predict outcomes from medical signal data, such as EEG 58 , electrocardiogram 59,60 and audio data 61 .”
BackgroundMethodYang, G., Ye, Q., & Xia, J. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.07.016 · Cited by 717
“Porumb et al. [89] combined CNN and RNN for electrocardiogram (ECG) analysis and applied Grad-CAM for the identification of the most relevant heartbeat segments for the hypoglycaemia detection.”
MethodA Review of Explainable Artificial Intelligence in Healthcare
Sadeghi, Z., Alizadehsani, R., CIFCI, M. A., Kausar, S., Rehman, R., Mahanta, P., Bora, P. K., Almasri, A., Alkhawaldeh, R. S., Hussain, S., et al. (2024) · Computers and Electrical Engineering · doi:10.1016/j.compeleceng.2024.109370 · Cited by 598
Hong, S., Zhou, Y., Shang, J., Xiao, C., & Sun, J. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103801 · Cited by 464
An intelligent healthcare monitoring framework using wearable sensors and social networking data
Ali, F., El-Sappagh, S., Islam, S. M. R., Ali, A., Attique, M., Imran, M., & Kwak, K.-S. (2021) · Future Generation Computer Systems · doi:10.1016/j.future.2020.07.047 · Cited by 355
Metadata
- Authors
- Porumb, M., Stranges, S., Pescapè, A., & Pecchia, L.
- Venue
- Scientific Reports
- Published
- 2020-01-13
- Volume
- 10
- Issue
- 1
- Pages
- 170-170
- ISSN
- 2045-2322 (ISSN-L)
- OpenAlex
- W3000630830
- Cited by
- 196
- References
- 92
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.