The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Planar chip device for PCR and hybridization with surface acoustic wave pump
Abstract
We have developed a microfluidic device operating at a planar surface instead of a closed channel network. The fluid is transported in single droplets using surface acoustic waves (SAW) on a piezoelectric LiNbO(3) substrate. The surface of the piezo is chemically structured to induce high contact angles of the droplets or enclose areas where the liquid can wet the substrate. Combining the SAW technique with thin film resistance heaters, a biological analysis chip with integrated DNA amplification by PCR and hybridization was designed. To prevent evaporation of the PCR reagents at high temperatures the sample is enclosed in droplets of mineral oil. On this chip the SAW resolves dried primers, shifts the oil capped liquid between the two heaters and mixes during hybridization. The chip is able to perform a highly sensitive, fast and specific PCR with a volume as low as 200 nl. During the temperature cycles an online monitoring of the DNA concentration is feasible with an optical unit, providing a sensitivity of 0.1 ng. After PCR the product is moved to the second heater for the hybridization on a spotted DNA array. With our chip we were able to detect a single nucleotide polymorphism (SNP) responsible for the Leiden Factor V syndrome from human blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Formation and Structure of Self-Assembled Monolayers
Ulman, A. (1996) · Chemical Reviews · doi:10.1021/cr9502357 · Cited by 7,906
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Structure and growth of self-assembling monolayers
Schreiber, F. (2000) · Progress in Surface Science · doi:10.1016/s0079-6816(00)00024-1 · Cited by 2,484
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Cho, S. K., Moon, H., & Kim, C.-J. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2002.807467 · Cited by 1,598
Electrowetting-based actuation of liquid droplets for microfluidic applications
Pollack, M. G., Fair, R. B., & Shenderov, A. D. (2000) · Applied Physics Letters · doi:10.1063/1.1308534 · Cited by 1,481
Light-Driven Motion of Liquids on a Photoresponsive Surface
Ichimura, K., Oh, S.-K., & Nakagawa, M. (2000) · Science · doi:10.1126/science.288.5471.1624 · Cited by 1,463
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (2013) · BioTechniques · doi:10.2144/000114043 · Cited by 1,274
Chemical Amplification: Continuous-Flow PCR on a Chip
Kopp, M. U., Mello, A. J. D., & Manz, A. (1998) · Science · doi:10.1126/science.280.5366.1046 · Cited by 1,212
Continuous Fluorescence Monitoring of Rapid Cycle DNA Amplification
Wittwer, C. T., Herrmann, M. G., Moss, A. A., & Rasmussen, R. P. (1997) · BioTechniques · doi:10.2144/97221bi01 · Cited by 1,143
The LightCycler TM : A Microvolume Multisample Fluorimeter with Rapid Temperature Control
Wittwer, C. T., Ririe, K. M., Andrew, R. V., David, D. A., Gundry, R. A., & Balis, U. J. (1997) · BioTechniques · doi:10.2144/97221pf02 · Cited by 893
Silanization of Solid Substrates: A Step Toward Reproducibility
Brzoska, J. B., Azouz, I. B., & Rondelez, F. (1994) · Langmuir · doi:10.1021/la00023a072 · Cited by 593
Biotechnology at low Reynolds numbers
Brody, J. P., Yager, P., Goldstein, R. E., & Austin, R. H. (1996) · Biophysical Journal · doi:10.1016/s0006-3495(96)79538-3 · Cited by 523
Single-Molecule DNA Amplification and Analysis in an Integrated Microfluidic Device
Lagally, E. T., Medintz, I. L., & Mathies, R. A. (2001) · Analytical Chemistry · doi:10.1021/ac001026b · Cited by 430
Microchip Device for Cell Lysis, Multiplex PCR Amplification, and Electrophoretic Sizing
Waters, L. C., Jacobson, S. C., Kroutchinina, N., Khandurina, J., Foote, R. S., & Ramsey, J. M. (1998) · Analytical Chemistry · doi:10.1021/ac970642d · Cited by 405
PCR Detection of Bacteria in Seven Minutes
Belgrader, P., Benett, W., Hadley, D., Richards, J., Stratton, P., Mariella, R., & Milanovich, F. (1999) · Science · doi:10.1126/science.284.5413.449 · Cited by 357
(1994) · Birkhäuser Boston eBooks · doi:10.1007/978-1-4612-0257-8 · Cited by 310
Dos Santos, F. D., & Ondarçuhu, T. (1995) · Physical Review Letters · doi:10.1103/physrevlett.75.2972 · Cited by 299
DNA Microarrays: A Practical Approach
Schena, M. (1999) · doi:10.1093/oso/9780199637775.001.0001 · Cited by 283
Electroosmotic pumping and electrophoretic separations for miniaturized chemical analysis systems
Manz, A., Effenhauser, C. S., Burggraf, N., Harrison, D. J., Seiler, K., & Fluri, K. (1994) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/4/4/010 · Cited by 277
Integrated Cell Isolation and Polymerase Chain Reaction Analysis Using Silicon Microfilter Chambers
Wilding, P., Kricka, L. J., Cheng, J., Hvichia, G., Shoffner, M. A., & Fortina, P. (1998) · Analytical Biochemistry · doi:10.1006/abio.1997.2530 · Cited by 276
A Miniature Analytical Instrument for Nucleic Acids Based on Micromachined Silicon Reaction Chambers
Northrup, M. A., Benett, B., Hadley, D. R., Landre, P., Lehew, S., Richards, J. M., & Stratton, P. (1998) · Analytical Chemistry · doi:10.1021/ac970486a · Cited by 266
A miniature integrated device for automated multistep genetic assays
Anderson, R. C. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.12.e60 · Cited by 227
DNA microarrays : a practical approach
Schena, M. (1999) · Oxford University Press eBooks · Cited by 222
Microfluidic Assays of Acetylcholinesterase Inhibitors
Hadd, A. G., Jacobson, S. C., & Ramsey, J. M. (1999) · Analytical Chemistry · doi:10.1021/ac990591f · Cited by 193
Molecular Gradients of .omega.-Substituted Alkanethiols on Gold: Preparation and Characterization
Liedberg, B., & Tengvall, P. (1995) · Langmuir · doi:10.1021/la00010a037 · Cited by 173
Development of A Microchamber Array for Picoliter PCR
Nagai, H., Murakami, Y., Morita, Y., et al. (2000) · Analytical Chemistry · doi:10.1021/ac000648u · Cited by 157
Liquid streaming and droplet formation caused by leaky Rayleigh waves
Shiokawa, S., Matsui, Y., & Ueda, T. (2003) · Proceedings/Proceedings - IEEE Ultrasonics Symposium · doi:10.1109/ultsym.1989.67063 · Cited by 127
A Battery-Powered Notebook Thermal Cycler for Rapid Multiplex Real-Time PCR Analysis
Belgrader, P., Young, S., Yuan, B., Primeau, M. J., Christel, L. A., Pourahmadi, F., & Northrup, M. A. (2000) · Analytical Chemistry · doi:10.1021/ac000905v · Cited by 118
Gene expression microarrays and the integration of biological knowledge
Noordewier, M. O., & Warren, P. V. (2001) · Trends in biotechnology · doi:10.1016/s0167-7799(01)01735-8 · Cited by 73
Development of Plastic Microfluidic Devices for Sample Preparation
Grodzinski, P. A., Liu, R. H., Chen, B., et al. (2001) · Biomedical Microdevices · doi:10.1023/a:1012400629650 · Cited by 47
Cited by
Reactions in Droplets in Microfluidic Channels
Song, H., Chen, D. L., & Ismagilov, R. F. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200601554 · Cited by 1,847
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964
Surface acoustic wave microfluidics
Ding, X., Li, P., Lin, S.-C. S., Stratton, Z. S., Nama, N., Guo, F., Slotcavage, D., Mao, X., Shi, J., Costanzo, F., et al. (2013) · Lab on a Chip · doi:10.1039/c3lc50361e · Cited by 926
Metadata
- Authors
- Guttenberg, Z., Müller, H., Habermüller, H., Geisbauer, A., Pipper, J., Felbel, J., Kielpinski, M., Scriba, J., & Wixforth, A.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2005
- Volume
- 5
- Issue
- 3
- Pages
- 308-317
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2041086464
- Cited by
- 349
- References
- 32
- FWCI
- 7.82
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.