The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Fundamentals of microfluidic cell culture in controlled microenvironments
Open accessAbstract
Microfluidics has the potential to revolutionize the way we approach cell biology research. The dimensions of microfluidic channels are well suited to the physical scale of biological cells, and the many advantages of microfluidics make it an attractive platform for new techniques in biology. One of the key benefits of microfluidics for basic biology is the ability to control parameters of the cell microenvironment at relevant length and time scales. Considerable progress has been made in the design and use of novel microfluidic devices for culturing cells and for subsequent treatment and analysis. With the recent pace of scientific discovery, it is becoming increasingly important to evaluate existing tools and techniques, and to synthesize fundamental concepts that would further improve the efficiency of biological research at the microscale. This tutorial review integrates fundamental principles from cell biology and local microenvironments with cell culture techniques and concepts in microfluidics. Culturing cells in microscale environments requires knowledge of multiple disciplines including physics, biochemistry, and engineering. We discuss basic concepts related to the physical and biochemical microenvironments of the cell, physicochemical properties of that microenvironment, cell culture techniques, and practical knowledge of microfluidic device design and operation. We also discuss the most recent advances in microfluidic cell culture and their implications on the future of the field. The goal is to guide new and interested researchers to the important areas and challenges facing the scientific community as we strive toward full integration of microfluidics with biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,016
Freshney, R. I. (2005) · Wiley eBooks · doi:10.1002/9780470649367 · Cited by 3,904
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Growth Factors, Matrices, and Forces Combine and Control Stem Cells
Discher, D. E., Mooney, D. J., & Zandstra, P. W. (2009) · Science · doi:10.1126/science.1171643 · Cited by 2,666
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,603
El-Ali, J., Sorger, P. K., & Jensen, K. F. (2006) · Nature · doi:10.1038/nature05063 · Cited by 2,105
Physics and Applications of Microfluidics in Biology
Beebe, D. J., Mensing, G. A., & Walker, G. M. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.112601.125916 · Cited by 1,803
Self-citationPamme, N. (2005) · Lab on a Chip · doi:10.1039/b513005k · Cited by 1,141
Review on micro molding of thermoplastic polymers
Heckele, M., & Schomburg, W. K. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/14/3/r01 · Cited by 924
Biological implications of polydimethylsiloxane-based microfluidic cell culture
Regehr, K. J., Domenech, M., Koepsel, J. T., Carver, K. C., Ellison-Zelski, S. J., Murphy, W. L., Schuler, L. A., Alarid, E. T., & Beebe, D. J. (2009) · Lab on a Chip · doi:10.1039/b903043c · Cited by 719
Self-citation
Research works printed but not linked: 1
- Cressey, 2008, Nat. Med., 14, 1292
Cited by
Sorted by citations
A practical guide to hydrogels for cell culture
Caliari, S. R., & Burdick, J. A. (2016) · Nature Methods · doi:10.1038/nmeth.3839 · Cited by 2,075
A guide to the organ-on-a-chip
Leung, C. M., de Haan, P., Ronaldson-Bouchard, K., Kim, G.-A., Ko, J., Rho, H. S., Chen, Z., Habibovic, P., Jeon, N. L., Takayama, S., et al. (2022) · Nature Reviews Methods Primers · doi:10.1038/s43586-022-00118-6 · Cited by 1,116
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
Prebiotic Systems Chemistry: New Perspectives for the Origins of Life
Ruiz-Mirazo, K., Briones, C., & de la Escosura, A. (2014) · Chemical Reviews · doi:10.1021/cr2004844 · Cited by 930
Advances in Microfluidic Materials, Functions, Integration, and Applications
Nge, P. N., Rogers, C. I., & Woolley, A. T. (2013) · Chemical Reviews · doi:10.1021/cr300337x · Cited by 989
PDMS with designer functionalities—Properties, modifications strategies, and applications
Wolf, M., Salieb–Beugelaar, G. B., & Hunziker, P. (2018) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.06.001 · Cited by 878
Engineers are from PDMS-land, Biologists are from Polystyrenia
Berthier, E., Young, E. W. K., & Beebe, D. J. (2012) · Lab on a Chip · doi:10.1039/c2lc20982a · Cited by 820
Self-citationThree-dimensional organotypic culture: experimental models of mammalian biology and disease
Shamir, E. R., & Ewald, A. J. (2014) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3873 · Cited by 719
Organ-on-a-chip: recent breakthroughs and future prospects
Wu, Q., Liu, J., Wang, X., Feng, L., Wu, J., Zhu, X., Wen, W., & Gong, X. (2020) · BioMedical Engineering OnLine · doi:10.1186/s12938-020-0752-0 · Cited by 730
Wang, Y. I., Abaci, H. E., & Shuler, M. L. (2016) · Biotechnology and Bioengineering · doi:10.1002/bit.26045 · Cited by 572
Micromilling: a method for ultra-rapid prototyping of plastic microfluidic devices
Guckenberger, D. J., de Groot, T. E., Wan, A. M. D., Beebe, D. J., & Young, E. W. K. (2015) · Lab on a Chip · doi:10.1039/c5lc00234f · Cited by 515
Self-citationApplication of microfluidic chip technology in pharmaceutical analysis: A review
Cui, P., & Wang, S. (2018) · Journal of Pharmaceutical Analysis · doi:10.1016/j.jpha.2018.12.001 · Cited by 401
Droplet microfluidics: recent developments and future applications
Solvas, X. C. I., & deMello, A. J. (2010) · Chemical Communications · doi:10.1039/c0cc02474k · Cited by 361
Park, J., Lee, B. K., Jeong, G. S., Hyun, J. K., Lee, C. J., & Lee, S. (2014) · Lab on a Chip · doi:10.1039/c4lc00962b · Cited by 363
Cell-Based Biosensors and Their Application in Biomedicine
Liu, Q., Wu, C., Cai, H., Hu, N., Zhou, J., & Wang, P. (2014) · Chemical Reviews · doi:10.1021/cr2003129 · Cited by 351
Xu, F., Celli, J., Rizvi, I., Moon, S., Hasan, T., & Demirci, U. (2011) · Biotechnology Journal · doi:10.1002/biot.201000340 · Cited by 337
Scaffold-based 3D cell culture models in cancer research
Abuwatfa, W. H., Pitt, W. G., & Husseini, G. A. (2024) · Journal of Biomedical Science · doi:10.1186/s12929-024-00994-y · Cited by 363
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 326
Microfluidic approaches for cancer cell detection, characterization, and separation
Chen, J., Li, J., & Sun, Y. (2012) · Lab on a Chip · doi:10.1039/c2lc21273k · Cited by 306
Tsai, M., Kita, A., Leach, J., Rounsevell, R., Huang, J. N., Moake, J., Ware, R. E., Fletcher, D. A., & Lam, W. A. (2012) · Journal of Clinical Investigation · doi:10.1172/jci58753 · Cited by 297
Axon diodes for the reconstruction of oriented neuronal networks in microfluidic chambers
Peyrin, J., Deleglise, B., Saïas, L., Vignes, M., Gougis, P., Magnifico, S., Bétuing, S., Pietri, M., Caboche, J., Vanhoutte, P., et al. (2011) · Lab on a Chip · doi:10.1039/c1lc20014c · Cited by 292
Moshksayan, K., Kashaninejad, N., Warkiani, M. E., Lock, J. G., Moghadas, H., Firoozabadi, B., Saidi, M. S., & Nguyen, N.-T. (2018) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2018.01.223 · Cited by 267
Tubeless microfluidic angiogenesis assay with three-dimensional endothelial-lined microvessels
Bischel, L. L., Young, E. W. K., Mader, B. R., & Beebe, D. J. (2012) · Biomaterials · doi:10.1016/j.biomaterials.2012.11.005 · Cited by 266
Self-citationNanotoxicology and Nanosafety: Safety-by-Design and Testing at a Glance
Zielińska, A., Costa, B. P., Ferreira, M. V., Miguéis, D., Louros, J. M. S., Durazzo, A., Lucarini, M., Eder, P., Chaud, M. V., Morsink, M. A. J., et al. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17134657 · Cited by 260
Narayanamurthy, V., Jeroish, Z. E., Bhuvaneshwari, K. S., Bayat, P., Premkumar, R., Samsuri, F., & Yusoff, M. M. (2020) · RSC Advances · doi:10.1039/d0ra00263a · Cited by 246
Microfluidics for Manipulating Cells
Mu, X., Zheng, W., Sun, J., Zhang, W., & Jiang, X. (2012) · Small · doi:10.1002/smll.201200996 · Cited by 215
Humayun, M., Chow, C., & Young, E. W. K. (2018) · Lab on a Chip · doi:10.1039/c7lc01357d · Cited by 215
Self-citationMicrofluidic devices for cell cultivation and proliferation
Tehranirokh, M., Kouzani, A. Z., Francis, P. S., & Kanwar, J. R. (2013) · Biomicrofluidics · doi:10.1063/1.4826935 · Cited by 206
Microfluidic platforms for cell cultures and investigations
Coluccio, M. L., Perozziello, G., Malara, N., Parrotta, E. I., Zhang, P., Gentile, F., Limongi, T., Raj, P. M., Cuda, G., Candeloro, P., et al. (2019) · Microelectronic Engineering · doi:10.1016/j.mee.2019.01.004 · Cited by 220
A modular approach to create a neurovascular unit-on-a-chip
Achyuta, A. K. H., Conway, A. J., Crouse, R. B., Bannister, E. C., Lee, R. N., Katnik, C. P., Behensky, A. A., Cuevas, J., & Sundaram, S. (2012) · Lab on a Chip · doi:10.1039/c2lc41033h · Cited by 194
Rapid formation of size-controllable multicellular spheroids via 3D acoustic tweezers
Chen, K., Wu, M., Guo, F., Li, P., Chan, C. Y., Mao, Z., Li, S., Ren, L., Zhang, R., & Huang, T. J. (2016) · Lab on a Chip · doi:10.1039/c6lc00444j · Cited by 187
Rapid Prototyping of Arrayed Microfluidic Systems in Polystyrene for Cell-Based Assays
Young, E. W. K., Berthier, E., Guckenberger, D. J., Sackmann, E. K., Lamers, C., Meyvantsson, I., Huttenlocher, A., & Beebe, D. J. (2011) · Analytical Chemistry · doi:10.1021/ac102897h · Cited by 177
Self-citationAralekallu, S., Boddula, R., & Singh, V. (2022) · Materials & Design · doi:10.1016/j.matdes.2022.111517 · Cited by 182
Misun, P. M., Rothe, J., Schmid, Y. R. F., Hierlemann, A. R., & Frey, O. (2016) · Microsystems & Nanoengineering · doi:10.1038/micronano.2016.22 · Cited by 175
Cardoso, B. D., Castanheira, E. M. S., Lanceros-Méndez, S., & Cardoso, V. F. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202936 · Cited by 171
PDMS-Based Microfluidic Devices for Cell Culture
Torino, S., Corrado, B., Iodice, M., & Coppola, G. (2018) · Inventions · doi:10.3390/inventions3030065 · Cited by 171
3D bioprinting: improving in vitro models of metastasis with heterogeneous tumor microenvironments
Albritton, J. L., & Miller, J. S. (2017) · Disease Models & Mechanisms · doi:10.1242/dmm.025049 · Cited by 154
In Vitro Microfluidic Models for Neurodegenerative Disorders
Osaki, T., Shin, Y., Sivathanu, V., Campisi, M., & Kamm, R. D. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700489 · Cited by 155
Microfluidics applications for high-throughput single cell sequencing
Zhou, W.-M., Yan, Y., Guo, Q.-R., Ji, H., Wang, H., Xu, T.-T., Makabel, B., Pilarsky, C. P., He, G., Yu, X.-Y., et al. (2021) · Journal of Nanobiotechnology · doi:10.1186/s12951-021-01045-6 · Cited by 150
Young, E. W. K. (2013) · Integrative Biology · doi:10.1039/c3ib40076j · Cited by 145
Self-citationOnline oxygen monitoring using integrated inkjet-printed sensors in a liver-on-a-chip system
Moya, A., Ortega‐Ribera, M., Villalba, X. G., Sowade, E., Zea, M., Illa, X., Ramón, E., Villa, R., Gracia‐Sancho, J., & Gabriel, G. (2018) · Lab on a Chip · doi:10.1039/c8lc00456k · Cited by 150
Characterization and evaluation of 3D printed microfluidic chip for cell processing
Lee, J. M., Zhang, M., & Yeong, W. Y. (2016) · Microfluidics and Nanofluidics · doi:10.1007/s10404-015-1688-8 · Cited by 142
Understanding the Impact of 2D and 3D Fibroblast Cultures on In Vitro Breast Cancer Models
Sung, K. E., Su, X., Berthier, E., Pehlke, C. A., Friedl, A., & Beebe, D. J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0076373 · Cited by 145
Self-citationZervantonakis, I. K., Kothapalli, C. R., Chung, S. H., Sudo, R., & Kamm, R. D. (2011) · Biomicrofluidics · doi:10.1063/1.3553237 · Cited by 141
Multi-Organs-on-Chips: Towards Long-Term Biomedical Investigations
Zhao, Y., Kankala, R. K., Wang, S., & Chen, A. (2019) · Molecules · doi:10.3390/molecules24040675 · Cited by 140
Materials and methods for droplet microfluidic device fabrication
Elvira, K. S., Gielen, F., Tsai, S. S. H., & Nightingale, A. M. (2022) · Lab on a Chip · doi:10.1039/d1lc00836f · Cited by 137
Hydrogel-coated microfluidic channels for cardiomyocyte culture
Annabi, N., Selimović, Š., Acevedo Cox, J. P., Ribas, J., Afshar Bakooshli, M., Heintze, D., Weiss, A. S., Cropek, D., & Khademhosseini, A. (2013) · Lab on a Chip · doi:10.1039/c3lc50252j · Cited by 129
Neto, E., Leitão, L., Sousa, D. M., Alves, C. J., Alencastre, I. S., Aguiar, P., & Lamghari, M. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.1748-16.2016 · Cited by 129
Mannino, R. G., Myers, D. R., Ahn, B., Wang, Y., Rollins, M., Gole, H., Lin, A. S., Guldberg, R. E., Giddens, D. P., Timmins, L. H., et al. (2015) · Scientific Reports · doi:10.1038/srep12401 · Cited by 127
Review of 3D cell culture with analysis in microfluidic systems
Castiaux, A. D., Spence, D. M., & Martin, R. S. (2019) · Analytical Methods · doi:10.1039/c9ay01328h · Cited by 134
Single-cell level co-culture platform for intercellular communication
Hong, S., Pan, Q., & Lee, L. P. (2012) · Integrative Biology · doi:10.1039/c2ib00166g · Cited by 122
Huber, D., Oskooei, A., Solvas, X. C. I., deMello, A. J., & Kaigala, G. V. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00317 · Cited by 131
Hydrogels: The Next Generation Body Materials for Microfluidic Chips?
Nie, J., Fu, J., & He, Y. (2020) · Small · doi:10.1002/smll.202003797 · Cited by 126
Platform for High-Throughput Testing of the Effect of Soluble Compounds on 3D Cell Cultures
Deiss, F. T., Mazzeo, A. D., Hong, E., Ingber, D. E., Derda, R., & Whitesides, G. M. (2013) · Analytical Chemistry · doi:10.1021/ac400161j · Cited by 119
Microfluidic systems for stem cell-based neural tissue engineering
Karimi, M., Bahrami, S., Mirshekari, H., Basri, S. M. M., Nik, A. B., Aref, A. R., Akbari, M., & Hamblin, M. R. (2016) · Lab on a Chip · doi:10.1039/c6lc00489j · Cited by 119
Nanoparticle-induced immune response: Health risk versus treatment opportunity?
Pondman, K. M., Gac, S. L., & Kishore, U. (2022) · Immunobiology · doi:10.1016/j.imbio.2022.152317 · Cited by 121
Allgayer, H., Mahapatra, S., Mishra, B., Swain, B., Saha, S., Khanra, S., Kumari, K., Panda, V. K., Malhotra, D., Patil, N. S., et al. (2025) · Molecular Cancer · doi:10.1186/s12943-025-02338-2 · Cited by 127
Ensemble Analysis of Angiogenic Growth in Three-Dimensional Microfluidic Cell Cultures
Farahat, W. A., Wood, L. B., Zervantonakis, I. K., Schor, A. R., Ong, L. S., Neal, D. M., Kamm, R. D., & Asada, H. H. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037333 · Cited by 117
Recent Developments in Microfluidics for Cell Studies
Xiong, B., Ren, K., Shu, Y., Chen, Y., Shen, B., & Wu, H. (2014) · Advanced Materials · doi:10.1002/adma.201305348 · Cited by 115
Patra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C. (2013) · Biomicrofluidics · doi:10.1063/1.4824480 · Cited by 109
Emerging trends in multiscale modeling of vascular pathophysiology: Organ-on-a-chip and 3D printing
Gold, K. A., Gaharwar, A. K., & Jain, A. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.029 · Cited by 114
Sharma, D., Ross, D., Wang, G., Jia, W., Kirkpatrick, S. J., & Zhao, F. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.03.016 · Cited by 110
Modular microfluidics for life sciences
Wu, J., Fang, H. M., Zhang, J., & Yan, S. (2023) · Journal of Nanobiotechnology · doi:10.1186/s12951-023-01846-x · Cited by 114
A microfluidic model of human brain (μHuB) for assessment of blood brain barrier
Brown, T. D., Nowak, M., Bayles, A. V., Prabhakarpandian, B., Karande, P., Lahann, J., Helgeson, M. E., & Mitragotri, S. (2018) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10126 · Cited by 106
Stretchable Electrochemical Sensors for Cell and Tissue Detection
Liu, Y., & Huang, W. (2021) · Angewandte Chemie International Edition · doi:10.1002/anie.202007754 · Cited by 105
A Synthetic Multifunctional Mammalian pH Sensor and CO2 Transgene-Control Device
Ausländer, D., Ausländer, S., Hamri, G. C., Sedlmayer, F., Müller, M., Frey, O., Hierlemann, A. R., Stelling, J., & Fussenegger, M. (2014) · Molecular Cell · doi:10.1016/j.molcel.2014.06.007 · Cited by 109
A microfluidic platform for chemoresistive testing of multicellular pleural cancer spheroids
Ruppen, J., Cortes-Dericks, L., Marconi, E., Karoubi, G., Schmid, R. A., Peng, R., Marti, T. M., & Guenat, O. T. (2014) · Lab Chip · doi:10.1039/c3lc51093j · Cited by 105
Fundamentals of rapid injection molding for microfluidic cell-based assays
Lee, U. N., Su, X., Guckenberger, D. J., Dostie, A. M., Zhang, T., Berthier, E., & Theberge, A. B. (2018) · Lab on a Chip · doi:10.1039/c7lc01052d · Cited by 105
Advances in microfluidic in vitro systems for neurological disease modeling
Holloway, P. M., Willaime‐Morawek, S., Siow, R. C. M., Barber, M., Owens, R. M., Sharma, A. D., Rowan, W. C., Hill, E. J., & Zagnoni, M. (2021) · Journal of Neuroscience Research · doi:10.1002/jnr.24794 · Cited by 101
Bruner‐Tran, K. L., Gnecco, J. S., Ding, T., Glore, D. R., Pensabene, V., & Osteen, K. G. (2016) · Reproductive Toxicology · doi:10.1016/j.reprotox.2016.07.007 · Cited by 108
Scaffold-free three-dimensional cell culturing using magnetic levitation
Türker, E., Demirçak, N., & Yıldız, A. A. (2018) · Biomaterials Science · doi:10.1039/c8bm00122g · Cited by 102
Microbial metabolomics in open microscale platforms
Barkal, L. J., Theberge, A. B., Guo, C., Spraker, J. E., Rappert, L., Berthier, J., Brakke, K. A., Wang, C. C. C., Beebe, D. J., Keller, N. P., et al. (2016) · Nature Communications · doi:10.1038/ncomms10610 · Cited by 105
Self-citationCurto, V. F., Marchiori, B., Hama, A., Pappa, A., Ferro, M. P., Braendlein, M., Rivnay, J., Fiocchi, M., Malliaras, G. G., Ramuz, M. P., et al. (2017) · Microsystems & Nanoengineering · doi:10.1038/micronano.2017.28 · Cited by 104
Cultivating Multidisciplinarity: Manufacturing and Sensing Challenges in Cultured Meat Production
Djisalov, M., Knežić, T., Podunavac, I., Živojević, K., Radonić, V., Knežević, N. Ž., Bobrinetskiy, I. I., & Gadjanski, I. (2021) · Biology · doi:10.3390/biology10030204 · Cited by 102
Microscale Strategies for Generating Cell-Encapsulating Hydrogels
Selimović, Š., Oh, J., Bae, H., Dokmeci, M. R., & Khademhosseini, A. (2012) · Polymers · doi:10.3390/polym4031554 · Cited by 99
Liu, S., Kumari, S., He, H., Mishra, P., Singh, B. N., Singh, D., Liu, S., Srivastava, P., & Li, C. (2023) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2023.115285 · Cited by 103
Bioreactor Technologies for Enhanced Organoid Culture
Licata, J. P., Schwab, K. H., Har-el, Y.-E., Gerstenhaber, J. A., & Lelkes, P. I. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms241411427 · Cited by 103
Organs-on-chip monitoring: sensors and other strategies
Kilic, T., Navaee, F., Stradolini, F., Renaud, P., & Carrara, S. (2018) · Microphysiological Systems · doi:10.21037/mps.2018.01.01 · Cited by 96
Advances of Microfluidics in Biomedical Engineering
Zhong, Q., Ding, H., Gao, B., He, Z., & Gu, Z. (2019) · Advanced Materials Technologies · doi:10.1002/admt.201800663 · Cited by 99
Recent advances in microfluidic 3D cellular scaffolds for drug assays
Wu, J., Chen, Q., Liu, W., He, Z., & Lin, J. (2016) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2016.11.009 · Cited by 95
Liu, M.-C., Shih, H.-C., Wu, J., Weng, T.-W., Wu, C., Lu, J.-C., & Tung, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc41414k · Cited by 96
Heart-on-a-chip based on stem cell biology
Jastrzębska, E., Tomecka, E., & Jesion, I. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.08.012 · Cited by 91
Microfluidic Perfusion for Regulating Diffusible Signaling in Stem Cells
Blagović, K., Kim, L. Y., & Joel Voldman, B. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022892 · Cited by 86
Controlling Differentiation of Stem Cells for Developing Personalized Organ‐on‐Chip Platforms
Geraili, A., Jafari, P., Hassani, M. S., Araghi, B. H., Mohammadi, M. H., Ghafari, A. M., Tamrin, S. H., Modarres, H. P., Kolahchi, A. R., Ahadian, S., et al. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700426 · Cited by 90
Fu, C.-Y., Tseng, S., Yang, S., Hsu, L., Liu, C., & Chang, H. (2014) · Biofabrication · doi:10.1088/1758-5082/6/1/015009 · Cited by 92
Borgmann, S., Schulte, A., Neugebauer, S., & Schuhmann, W. W. (2011) · Advances in electrochemical science and engineering · doi:10.1002/9783527644117.ch1 · Cited by 93
Recent advances in microchip-mass spectrometry for biological analysis
He, X., Chen, Q., Zhang, Y., & Lin, J. (2013) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2013.09.013 · Cited by 83
Toward the broad adoption of 3D tumor models in the cancer drug pipeline
Cox, M. C., Reese, L. M., Bickford, L. R., & Verbridge, S. S. (2015) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.5b00172 · Cited by 80
Effects of magnesium alloy corrosion on biological response – Perspectives of metal-cell interaction
Kim, J., & Pan, H. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2022.101039 · Cited by 84
Microfluidic systems for hydrodynamic trapping of cells and clusters
Luan, Q., Macaraniag, C., Zhou, J., & Papautsky, I. (2020) · Biomicrofluidics · doi:10.1063/5.0002866 · Cited by 78
Microfluidic probes for use in life sciences and medicine
Qasaimeh, M. A., Ricoult, S. G., & Juncker, D. (2012) · Lab on a Chip · doi:10.1039/c2lc40898h · Cited by 76
Morgan, M. M., Johnson, B. P., Livingston, M. K., Schuler, L. A., Alarid, E. T., Sung, K. E., & Beebe, D. J. (2016) · Pharmacology & Therapeutics · doi:10.1016/j.pharmthera.2016.05.007 · Cited by 75
Self-citationProbing cell–cell communication with microfluidic devices
Guo, F., French, J. B., Li, P., Zhao, H., Chan, C. Y., Fick, J. R., Benkovic, S. J., & Huang, T. J. (2013) · Lab on a Chip · doi:10.1039/c3lc90067c · Cited by 74
Hydrophilic Sponges for Leaf‐Inspired Continuous Pumping of Liquids
Zhou, T., Yang, J., Zhu, D., Zheng, J., Handschuh‐Wang, S., Zhou, X., Zhang, J., Liu, Y., Liu, Z., He, C., et al. (2017) · Advanced Science · doi:10.1002/advs.201700028 · Cited by 74
Su, X., Young, E. W. K., Underkofler, H. A. S., Kamp, T. J., January, C. T., & Beebe, D. J. (2010) · SLAS DISCOVERY · doi:10.1177/1087057110386218 · Cited by 76
Self-citationSimple replica micromolding of biocompatible styrenic elastomers
Borysiak, M. D., Bielawski, K. S., Sniadecki, N. J., Jenkel, C. F., Vogt, B. D., & Posner, J. D. (2013) · Lab on a Chip · doi:10.1039/c3lc50426c · Cited by 72
Integrating Immunology and Microfluidics for Single Immune Cell Analysis
Sinha, N., Subedi, N., & Tel, J. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.02373 · Cited by 72
Design and engineering of organ-on-a-chip
Cho, S., Lee, S., & Ahn, S. I. (2023) · Biomedical Engineering Letters · doi:10.1007/s13534-022-00258-4 · Cited by 74
Advances in ex vivo models and lab-on-a-chip devices for neural tissue engineering
Mobini, S., Song, Y. H., McCrary, M. W., & Schmidt, C. E. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.05.012 · Cited by 72
Metadata
- Authors
- Young, E. W. K., & Beebe, D. J.
- Affiliations
- University of Wisconsin–Madison (US)
- Corresponding author
- Beebe, David J.
- Venue
- Chemical Society Reviews
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 39
- Issue
- 3
- Pages
- 1036
- ISSN
- 0306-0012 (ISSN-L)
- 1460-4744
- PMC
- PMC2967183
- OpenAlex
- W2092941484
- Cited by
- 615
- References
- 54
- Citations by year
- 2026: 30 · 2025: 35 · 2024: 29 · 2023: 32 · 2022: 39 · 2021: 35 · 2020: 42 · 2019: 38 · 2018: 60 · 2017: 38 · 2016: 41 · 2015: 29 · 2014: 45 · 2013: 44 · 2012: 35
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Chemical Society Reviews (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- Natural Sciences and Engineering Research Council of Canada
- National Cancer Institute (R33CA137673)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Capillary Electrophoresis Applications
- Physical Sciences › Engineering › Biomedical Engineering › 3D Printing in Biomedical Research
- Physical Sciences › Engineering › Biomedical Engineering › Microfluidic and Bio-sensing Technologies
- Keywords
- microfluidic cell culture, cell microenvironment, microfluidic device design, cell culture, microfluidics
- MeSH terms
- Endothelium, Humans, Muscle, Smooth, Cell Culture Techniques, Microfluidics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review