The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
A packaged optical slot-waveguide ring resonator sensor array for multiplex label-free assays in labs-on-chips
Open accessAbstract
We present the design, fabrication, and characterisation of an array of optical slot-waveguide ring resonator sensors, integrated with microfluidic sample handling in a compact cartridge, for multiplexed real-time label-free biosensing. Multiplexing not only enables high throughput, but also provides reference channels for drift compensation and control experiments. Our use of alignment tolerant surface gratings to couple light into the optical chip enables quick replacement of cartridges in the read-out instrument. Furthermore, our novel use of a dual surface-energy adhesive film to bond a hard plastic shell directly to the PDMS microfluidic network allows for fast and leak-tight assembly of compact cartridges with tightly spaced fluidic interconnects. The high sensitivity of the slot-waveguide resonators, combined with on-chip referencing and physical modelling, yields a volume refractive index detection limit of 5 x 10(-6) refractive index units (RIUs) and a surface mass density detection limit of 0.9 pg mm(-2), to our knowledge the best reported values for integrated planar ring resonators.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Xia, Y., & Whitesides, G. M. (1998) · Angewandte Chemie International Edition · doi:10.1002/(sici)1521-3773(19980316)37:5<550::aid-anie550>3.0.co;2-g · Cited by 4,285
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Guiding and confining light in void nanostructure
Almeida, V. R., Xu, Q., Barrios, C. A., & Lipson, M. (2004) · Optics Letters · doi:10.1364/ol.29.001209 · Cited by 1,732
Self-citationSilicon Processing for the VLSI Era
Wolf, S. M., & Tauber, R. N. (1986) · Medical Entomology and Zoology · Cited by 1,541
De Feijter, J. A., Benjamins, J., & Veer, F. A. (1978) · Biopolymers · doi:10.1002/bip.1978.360170711 · Cited by 1,289
Universal relations for coupling of optical powerbetweenmicroresonators and dielectric waveguides
Yariv, A. (2000) · Electronics Letters · doi:10.1049/el:20000340 · Cited by 1,149
On the performance quantification of resonant refractive index sensors
White, I. M., & Fan, X. (2008) · Optics Express · doi:10.1364/oe.16.001020 · Cited by 1,105
Silicon-on-Insulator microring resonator for sensitive and label-free biosensing
De Vos, K., Bartolozzi, I., Schacht, E., Bienstman, P., & Baets, R. (2007) · Optics Express · doi:10.1364/oe.15.007610 · Cited by 839
The mechanical properties of the rubber elastic polymer polydimethylsiloxane for sensor applications
Lötters, J. C., Olthuis, W., Veltink, P. H., & Bergveld, P. (1997) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/7/3/017 · Cited by 827
Scaling and the design of miniaturized chemical-analysis systems
Janasek, D., Franzke, J., & Manz, A. (2006) · Nature · doi:10.1038/nature05059 · Cited by 716
Low-Loss SOI Photonic Wires and Ring Resonators Fabricated With Deep UV Lithography
Dumon, P., Bogaerts, W., Wiaux, V., Wouters, J., Beckx, S., Van Campenhout, J., Taillaert, D., Luyssaert, B., Bienstman, P., Van Thourhout, D., et al. (2004) · IEEE Photonics Technology Letters · doi:10.1109/lpt.2004.826025 · Cited by 433
Optical sensing of biomolecules using microring resonators
Yalcin, A., Popat, K. C., Aldridge, J. C., Desai, T. A., Hryniewicz, J., Chbouki, N., Little, B. E., King, O., Van, V., Chu, S., et al. (2006) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2005.863003 · Cited by 377
Slot-waveguide biochemical sensor
Barrios, C. A., Gylfason, K. B., Sánchez, B., Griol, A., Sohlström, H., Holgado, M., & Casquel, R. (2007) · Optics Letters · doi:10.1364/ol.32.003080 · Cited by 374
Self-citationMass transport and surface reactions in microfluidic systems
Gervais, T., & Jensen, K. F. (2006) · Chemical Engineering Science · doi:10.1016/j.ces.2005.06.024 · Cited by 301
Fast, Ultrasensitive Virus Detection Using a Young Interferometer Sensor
Ymeti, A., Greve, J., Lambeck, P. V., Wink, T., van Hövell, Beumer, Wijn, R. R., Heideman, R. G., Subramaniam, V., & Kanger, J. S. (2007) · Nano Letters · doi:10.1021/nl062595n · Cited by 287
Integrated optics ring-resonator sensors for protein detection
Ksendzov, A., & Lin, Y. (2005) · Optics Letters · doi:10.1364/ol.30.003344 · Cited by 253
Label-free optical biosensing with slot-waveguides
Barrios, C. A., Bañuls, M. J., González-Pedro, V., Gylfason, K. B., Sánchez, B., Griol, A., Maquieira, A., Sohlström, H., Holgado, M., & Casquel, R. (2008) · Optics Letters · doi:10.1364/ol.33.000708 · Cited by 242
Self-citationA universal biosensing platform based on optical micro-ring resonators
Ramachandran, A., Wang, S., Clarke, J., Ja, S. J., Goad, D., Wald, L., Flood, E. M., Knobbe, E., Hryniewicz, J. V., Chu, S. T., et al. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2007.09.007 · Cited by 225
A new quantitative optical biosensor for protein characterisation
Cross, G. H., Reeves, A. A., Brand, S., Popplewell, J. F., Peel, L. L., Swann, M. J., & Freeman, N. J. (2003) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(03)00203-3 · Cited by 219
Self-citationDuffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/3/301 · Cited by 205
Microfluidic channel fabrication by PDMS-interface bonding
Chow, W. W. Y., Lei, K. F., Shi, G., et al. (2005) · Smart Materials and Structures · doi:10.1088/0964-1726/15/1/018 · Cited by 123
Vos, K. D., Gironès, J., Popelka, Š., Schacht, E. H., Baets, R., & Bienstman, P. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.01.009 · Cited by 116
Shani, Y., HENRY, C. H., KISTLER, R. C., Orlowsky, K. J., & Ackerman, D. A. (1989) · Applied Physics Letters · doi:10.1063/1.102290 · Cited by 105
High efficiency silicon nitride surface grating couplers
Maire, G., Vivien, L., Sattler, G., Kaźmierczak, A., Sánchez, B., Gylfason, K. B., Griol, A., Marris‐Morini, D., Cassan, É., Giannone, D., et al. (2008) · Optics Express · doi:10.1364/oe.16.000328 · Cited by 89
Self-citationThe 25th European Conference on Integrated Optics
Witzens, J., Poon, J., Zimmermann, L., & Freude, W. (2024) · Springer proceedings in physics · doi:10.1007/978-3-031-63378-2 · Cited by 19
Cited by
Integrated optical devices for lab‐on‐a‐chip biosensing applications
Estevez, M. C., Alvarez, M., & Lechuga, L. M. (2012) · Laser & Photonics Reviews · doi:10.1002/lpor.201100025 · Cited by 617
Vollmer, F., & Yang, L. (2012) · nanoph · doi:10.1515/nanoph-2012-0021 · Cited by 546
Xu, Y., Bai, P., Zhou, X., Akimov, Y., Png, C. E., Ang, L., Knoll, W., & Wu, L. (2019) · Advanced Optical Materials · doi:10.1002/adom.201801433 · Cited by 519
Silicon Photonic Biosensors Using Label-Free Detection
Luan, E., Shoman, H., Ratner, D. M., Cheung, K. C., & Chrostowski, L. (2018) · Sensors · doi:10.3390/s18103519 · Cited by 379
Label-free biological and chemical sensors
Hunt, H. K., & Armani, A. M. (2010) · Nanoscale · doi:10.1039/c0nr00201a · Cited by 371
Metadata
- Authors
- Carlborg, C. F., Gylfason, K. B., Kaźmierczak, A., Dortu, F., Bañuls Polo, M. J., Maquieira Catala, A., Kresbach, G. M., Sohlström, H., Moh, T., Vivien, L., Popplewell, J., Ronan, G., Barrios, C. A., Stemme, G., & van der Wijngaart, W.
- Venue
- Lab Chip
- Publisher
- Royal Society of Chemistry (RSC)
- Published
- 2010
- Volume
- 10
- Issue
- 3
- Pages
- 281-290
- ISSN
- 1473-0189 (ISSN-L)
- 1473-0197
- OpenAlex
- W2091442580
- Cited by
- 275
- References
- 25
- FWCI
- 17.42
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.